CS Paper Radar

An Ultra-Widefield Swept-Source OCTA Dataset and a Polar-Gated Mamba Network for Retinal Vessel Segmentation

Yang Liu, Yibing Shen, Keming Zhao, Cenk Jiang, Zhenghang Qian, Zhicheng Du, Chen Xiong, Qidong Shao, Zijun Lin, Yunqi Hu, Jingjing Zhou, Lian Zhang, Peter E. Lobie, Peiwu Qin, Chengming Yang

cs.CV ·submitted 2026-09-11 08:25 UTC · v1
code/data

Abstract

Ultra-widefield (UWF) swept-source optical coherence tomography angiography (SS-OCTA) enables large-area retinal vascular imaging, yet vessel segmentation at this scale lacks dedicated public benchmarks and comprehensive evaluation for quantitative vascular analysis. We introduce WOIVES, to our knowledge the first publicly available UWF SS-OCTA vessel-segmentation dataset, comprising 206 eyes from 152 participants with a 24x20mm^2 field of view. WOIVES spans emmetropia to high myopia and provides soft probability vessel annotations. We further propose PG-Mamba, a visual state space model that enhances conventional directional scans with two complementary polar-coordinate scan orders. An auxiliary Dynamic FOV Gating module performs spatial modulation at the bottleneck. PG-Mamba outperformed seven competitive approaches on broad segmentation metrics under cross-validation. It achieved the lowest median absolute errors for vessel density, fractal dimension, and vessel length density. WOIVES is publicly available on Zenodo (DOI: 10.5281/zenodo.21904672), and the PG-Mamba code is available at https://github.com/syb1234567/PG-Mamba.

Comment
Submitted to IEEE Journal of Biomedical and Health Informatics. Under review

Closest papers

Nearest neighbours by meaning across the whole index.

U-PEN Mamba: Progressive Expansion with Selective State-Space Modeling for Efficient Retinal Vessel Segmentation

cs.CV ·2026-09-21 ·Abel A. Reyes-Angulo, Sidike Paheding, Vijayan K. Asari, Mohammad Alam, Jeevan Devagiri
publishedcode/data similarity 0.71
Abstract

Accurate retinal vessel segmentation is important for computer-aided ophthalmic analysis, yet thin vessels, low contrast, and severe foreground-background imbalance remain challenging for encoder-decoder networks. This paper presents U-PEN Mamba, a U-shaped retinal vessel segmentation architecture that couples progressive nonlinear feature expansion with selective state-space modeling. The proposed network enriches local vessel responses with progressive expansion, models long-range spatial dependencies through a Mamba Global Context (MGC) block with linear sequence complexity, and uses attention-based decoder fusion to recover fine vascular boundaries. We evaluate U-PEN Mamba on CHASE DB1 and DRIVE using a consistent patch-based preprocessing pipeline and compare it with convolutional, attention-based, transformer-based, and Mamba-based segmentation baselines. U-PEN Mamba obtains the best mean intersection over union among the compared methods, achieving 0.8394 on CHASE DB1 and 0.8221 on DRIVE, with Dice scores of 0.8187 and 0.8078, respectively, using 21.6M trainable parameters. Ablation studies show that the MGC block contributes the largest gain over the U-Net baseline, while projection dimension and state size provide practical accuracy-efficiency control. These results indicate that selective state-space modeling is a promising global-context mechanism for parameter-efficient retinal vessel segmentation. Code is available at: https://github.com/areyesan/UPEN_Mamba.

0.45

RBA: A Read-out Basis Adapter for Parameter-Efficient Interactive OCTA Vessel Segmentation with SEEM

cs.CV cs.LG ·2026-11-09 ·Jaafar M. Al-Ghabban, Mohammad Reza Mohammadi
similarity 0.69
Abstract

Retinal disease monitoring with optical coherence tomography angiography (OCTA) relies on segmentation of vessels and the foveal avascular zone (FAZ). Promptable models such as SEEM (Segment Everything Everywhere All at Once) allow click-based refinement, but without adaptation SEEM segments thin vessels poorly and needs many clicks. Fully fine-tuning its 342 million parameters on a few hundred images is costly and risks overfitting, and parameter-efficient methods such as low-rank adaptation (LoRA) usually adapt only the encoder. Yet SEEM reads every candidate mask from one feature map at quarter resolution, too coarse for vessels one to three pixels wide. This study introduces the Read-out Basis Adapter (RBA), whose read-out branch generates 32 image-specific basis maps at half resolution. Each candidate accesses them through its own vector and a zero-initialised projection, so the model starts exactly as SEEM. The encoder branch, a standard rank-1 LoRA, supplies the information needed to tell arteries from veins. RBA adds 0.47 million trainable parameters. Under simulated error-driven clicks, with the ground truth used only to place them, RBA outperforms LoRA, Conv-LoRA andAdaptFormer on OCTA-500 3mmlarge vessels. Averaged over three seeds, it reaches an intersection over union (IoU) of 85.16% and a Dice score of 91.93%, 2.90 and 1.72 percentage points above Conv-LoRA. On the 6 mm subset, one run gives margins of 4.35 and 2.76 points. The gain extends to arteries, veins and ROSE-O but not to the FAZ. In SEEM, adaptation capacity pays more at the mask read-out than in the encoder.

0.25

Evidence-Guided Selection of Retinal Vessel Segmentation Pipelines: A Cross-Dataset Benchmark of Performance, Structure, Failure Modes, and Reproducibility

cs.CV ·2026-10-22 ·Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo +2 more
benchmark similarity 0.69
Abstract

Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structural fidelity, cross-dataset robustness, and application-specific error costs. We evaluated five executable binary vessel-segmentation pipelines (FSG-Net, SA-UNetv2, DCP-1024, GAVE, and FR-UNet) on 244 images from six public datasets using pixel-level agreement, cross-dataset stability, thin-vessel retention, structural metrics, error composition, and available computational evidence. Results were aggregated with equal weighting across datasets. No pipeline was optimal in every setting. FSG-Net achieved the highest equal-dataset mean Macro-F1 (0.77), IoU (0.63), clDice (0.83), and Skeleton F1 (0.78), whereas SA-UNetv2 achieved the highest mean sensitivity (0.85) and Thin-Vessel Sensitivity (0.63). Differences across datasets were often larger than those among the leading pipelines, and errors shared by all five methods were concentrated near annotated vessel boundaries and faint peripheral vessels. In an ancillary analysis on 45 HRF images, segmentation masks were converted into 11 ring-wise vascular features for leave-one-out classification. Controlled perturbations showed that local mask errors can be amplified in downstream features, while targeted stabilization reduced sensitivity for five features. The results support task-conditioned, benchmark-relative pipeline selection rather than a single universal ranking and highlight the need to validate the selected pipeline on the intended target domain.

0.09

Retinal OCTA Phenotyping with LLM Reporting for Alzheimer's Disease

cs.CV cs.CL ·2026-09-04 ·Progga Paromita Dutta, Jeba Maliha, Md Rafiul Kabir
similarity 0.67
Abstract · 4th IEE International Conference on Artificial Intelligence, Blockchain, and Internet of Things, (AIBThings)

Early identification of Alzheimer's disease (AD) remains challenging because established assessment methods can be costly, resource-intensive, or unsuitable for population-scale screening. Optical coherence tomography angiography (OCTA) provides non-invasive visualization of retinal microvasculature, but existing approaches often require diagnostic labels and provide limited measurement-level interpretation. We present an explainable OCTA pipeline that integrates annotation-aware vessel segmentation, layer-specific vascular biomarker extraction, label-free phenotyping, and measurement-grounded LLM reporting. Using 117 ROSE-1 images from 39 subjects, we apply annotation-matched segmentation models to superficial vascular complex (SVC), deep vascular complex (DVC), and combined SVC+DVC representations. The models achieve ROC-AUC values of 0.916-0.970 and Dice scores of 0.695-0.781. Six density and fractal-dimension biomarkers form subject-level profiles for exploratory clustering. Analysis of nine held-out subjects identifies an internally consistent lower-density, lower-fractal-dimension phenotype, although the absence of diagnostic labels prevents clinical interpretation. Reports generated using GPT, Gemini, and Llama are evaluated for measurement grounding, citation faithfulness, and diagnostic caution. Overall, the framework provides a transparent, non-diagnostic connection between retinal vascular measurements, exploratory phenotyping, and evidence-linked interpretation for Alzheimer's research.

0.12

FPG-Seg: Annotation-free Retinal Vessel Topology Segmentation

cs.CV ·2026-10-15 ·James Willoughby, Irina Voiculescu
benchmark similarity 0.66
Abstract

State-of-the art approaches to retinal vessel segmentation typically require extensive annotations, a highly time-consuming process, reliant on clinical expertise. We present FPG-Seg, an annotation-free pipeline for retinal vessel segmentation combining classical vesselness filtering, Bayesian deep learning and topology-aware graph reconstruction to segment retinal vessel topology without manual labels. Tested across four widely used benchmark datasets for retinal vessel segmentation, FPG-Seg attains a clDice of $0.74{-}0.78$, representing $86{-}98\%$ of the performance of an equivalent fully-supervised baseline, despite using no manual annotations for training or hyperparameter tuning. As part of this work, we also provide, to our knowledge, the first performance benchmark of an annotation-free vessel segmentation method on FIVES.

0.18

Evaluating SAM-based and Convolutional Architectures in Thin Retinal Vessel Segmentation: Model Capacity, Computational Cost and Foundation Pre-training

cs.CV ·2026-10-30 ·Carlos Eduardo Fontaneli, Cesar Henrique Comin
similarity 0.65
Abstract

In retinal vessel segmentation, plain Vision Transformers (ViTs) are commonly expected to perform worse than convolutional neural networks (CNNs) on thin vessels, for reasons such as their coarse patch tokenization, their weak locality bias and their need for large training sets. Although this expectation is widely shared in the literature, how plain ViTs actually compare with CNNs on thin vessels has not been systematically quantified. We address this question by comparing a model with a plain ViT encoder (MedSAM), a hybrid Transformer (LiteMedSAM) and three CNNs of different sizes on three retinal datasets (DRIVE, HRF, FIVES) and, as a second-domain check, a microscopy dataset (VessMap). We measured the centerline recall and precision of thin vessels and compared the models while also considering their computational cost and how many epochs they needed to train. We found that the pre-trained MedSAM had a centerline recall of thin vessels that was not significantly different from that of the best CNN on all four datasets (-0.6 to +2.5 percentage points). A compact plain ViT obtained through architecture search but trained from scratch did not retain this performance. For pre-trained plain ViTs, our results do not support the expectation that they miss thin vessels, although similar thin-vessel performance can be obtained with much smaller models.

0.23

CGDD-Net: Context-Guided Dynamic Detail Modeling for Retinal Vessel Segmentation

cs.CV ·2026-10-04 ·Xincheng Li, Xiaoqi Sheng, Xinyu Zhang
code/data similarity 0.64
Abstract

Accurate retinal vessel segmentation requires features that capture vascular geometry while preserving information for fine-scale reconstruction. We propose CGDD-Net, a context-guided dynamic detail modeling network that connects adaptive feature extraction to a shared decoder pathway. Context-Guided Scale-Adaptive Deformable Encoding (CSDE) combines fixed-grid convolution with deformable local attention to capture vascular patterns at multiple spatial extents. Spatially Adaptive Multi-Kernel Gating (SAMG) selects receptive-field responses at each location. Dynamic Cross-Scale Detail Fusion (DCDF) aligns the gated intermediate features and compresses them into an eight-channel representation, which is reused at three decoder resolutions together with selected encoder skips. This design consolidates intermediate information before decoding instead of transferring each middle-stage feature through a separate direct skip. On DRIVE, CHASE\_DB1, STARE, and HRF, CGDD-Net achieves AUC values of 0.9824, 0.9938, 0.9895, and 0.9874, with F1 scores of 0.8323, 0.8102, 0.8510, and 0.8157, respectively. The complete model contains 1.96 million trainable parameters. In cumulative ablations, the full model improves F1 over the internal baseline by 2.48, 0.61, and 3.49 percentage points on DRIVE, CHASE\_DB1, and STARE. Twelve directed cross-dataset experiments further characterize transfer without target-domain adaptation. The results support shared intermediate detail delivery as an effective, parameter-compact architecture for retinal vessel segmentation. Code is available at \url{https://github.com/lixincheng-xcl/CGDD-Net}.

0.18

RetiWave-Mamba: A Dual-Stream Network for Retinal Disease Detection based on Multi-scale Context and Feature-Adaptive Mamba Projection

cs.CV ·2026-08-18 ·Cheng Cheng, Jin Hong
published similarity 0.63
Abstract

Retinal diseases are a leading cause of irreversible vision impairment, making early and accurate diagnosis essential for effective treatment. Optical Coherence Tomography (OCT) serves as a critical imaging modality for this purpose, yet its automated analysis is hindered by inherent speckle noise, varying lesion scales, and subtle inter-class similarities. To address these challenges, we propose a novel framework, RetiWave-Mamba, which integrates spatial-frequency domain learning with state-of-the-art state space models. The framework utilizes Discrete Wavelet Transform (DWT) to decompose OCT images into low- and high-frequency streams, enabling decoupled processing of structural context and fine-grained details. For the low-frequency branch, we design a Multi-scale Contextual Localization Module (MCLM), which synergizes multi-scale dilation with spatial attention to expand the global receptive field and precisely localize lesion regions. For the high-frequency branch, we introduce an Attention-Guided High-Resolution Network (AG-HRNet) equipped with an intelligent gating mechanism to suppress noise propagation during multi-scale interactions. Furthermore, a Feature-Adaptive Mamba Projector (FAMP) is incorporated to form complementary channel-wise feature paths and adaptively reweight them using Mamba-generated gates. Extensive experiments on the OCT-C8 dataset demonstrate that our approach achieves a state-of-the-art (SOTA) classification accuracy of 98.38, surpassing existing methods. These results highlight the effectiveness of RetiWave-Mamba in identifying retinal pathologies and support its potential for computer-aided OCT image analysis.

0.30