In retinal vessel segmentation, plain Vision Transformers (ViTs) are commonly expected to perform worse than convolutional neural networks (CNNs) on thin vessels, for reasons such as their coarse patch tokenization, their weak locality bias and their need for large training sets. Although this expectation is widely shared in the literature, how plain ViTs actually compare with CNNs on thin vessels has not been systematically quantified. We address this question by comparing a model with a plain ViT encoder (MedSAM), a hybrid Transformer (LiteMedSAM) and three CNNs of different sizes on three retinal datasets (DRIVE, HRF, FIVES) and, as a second-domain check, a microscopy dataset (VessMap). We measured the centerline recall and precision of thin vessels and compared the models while also considering their computational cost and how many epochs they needed to train. We found that the pre-trained MedSAM had a centerline recall of thin vessels that was not significantly different from that of the best CNN on all four datasets (-0.6 to +2.5 percentage points). A compact plain ViT obtained through architecture search but trained from scratch did not retain this performance. For pre-trained plain ViTs, our results do not support the expectation that they miss thin vessels, although similar thin-vessel performance can be obtained with much smaller models.

Closest papers

Nearest neighbours by meaning across the whole index.

Evidence-Guided Selection of Retinal Vessel Segmentation Pipelines: A Cross-Dataset Benchmark of Performance, Structure, Failure Modes, and Reproducibility

cs.CV ·2026-10-22 ·Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo +2 more
benchmark similarity 0.72
Abstract

Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structural fidelity, cross-dataset robustness, and application-specific error costs. We evaluated five executable binary vessel-segmentation pipelines (FSG-Net, SA-UNetv2, DCP-1024, GAVE, and FR-UNet) on 244 images from six public datasets using pixel-level agreement, cross-dataset stability, thin-vessel retention, structural metrics, error composition, and available computational evidence. Results were aggregated with equal weighting across datasets. No pipeline was optimal in every setting. FSG-Net achieved the highest equal-dataset mean Macro-F1 (0.77), IoU (0.63), clDice (0.83), and Skeleton F1 (0.78), whereas SA-UNetv2 achieved the highest mean sensitivity (0.85) and Thin-Vessel Sensitivity (0.63). Differences across datasets were often larger than those among the leading pipelines, and errors shared by all five methods were concentrated near annotated vessel boundaries and faint peripheral vessels. In an ancillary analysis on 45 HRF images, segmentation masks were converted into 11 ring-wise vascular features for leave-one-out classification. Controlled perturbations showed that local mask errors can be amplified in downstream features, while targeted stabilization reduced sensitivity for five features. The results support task-conditioned, benchmark-relative pipeline selection rather than a single universal ranking and highlight the need to validate the selected pipeline on the intended target domain.

0.09

OptiModNet: A UNet-Transformer Hybrid with Grouped-Query and Channel Attention for Optic Disc and Cup Segmentation

cs.CV cs.AI ·2026-08-19 ·Soumili Ghosh, Debapriya Roy, Aryan Das, Bikash Santra
code/data similarity 0.69
Abstract

Precise segmentation of the optic disc and cup is critical for the early detection and diagnosis of glaucoma. However, achieving consistently high performance across datasets while maintaining low computational requirements remains a significant challenge. In glaucoma detection, low-computation methods are crucial for enabling rapid, large-scale screening and facilitating deployment in resource-limited clinical environments. While deep learning models such as UNets, Vision Transformers (ViTs), and Diffusion models have demonstrated strong segmentation performance but these methods often come with substantial computational overhead. UNets are efficient at capturing local features but are limited in modeling global contextual information. Conversely, ViTs excel at long-range dependency modeling but are computationally intensive. Hybrid architectures, such as UNetR, which combine transformer-based encoders with UNet-style decoders, have shown improved performance but while incurring additional complexity. Considering these, in this work, we propose OptiModNet, a light weight novel hybrid architecture tailored for optic disc and cup segmentation. The model integrates diverse attention mechanisms at multiple stages of the network to enhance both local and global feature representation. We include an Aggregated Pyramid Loss that supervises predictions at multiple decoder depths, to promote better gradient flow and structural consistency. We evaluate OptiModNet on the REFUGE2 dataset for both optic disc and cup segmentation tasks. Our method achieves state-of-the-art performance, exceeding existing approaches by over 2.5\%, while maintaining high efficiency with only 3.73 GFLOPs and 1.93M parameters. The code is available at https://github.com/SG1947/OptiModNet.

0.24

U-PEN Mamba: Progressive Expansion with Selective State-Space Modeling for Efficient Retinal Vessel Segmentation

cs.CV ·2026-09-21 ·Abel A. Reyes-Angulo, Sidike Paheding, Vijayan K. Asari, Mohammad Alam, Jeevan Devagiri
publishedcode/data similarity 0.68
Abstract

Accurate retinal vessel segmentation is important for computer-aided ophthalmic analysis, yet thin vessels, low contrast, and severe foreground-background imbalance remain challenging for encoder-decoder networks. This paper presents U-PEN Mamba, a U-shaped retinal vessel segmentation architecture that couples progressive nonlinear feature expansion with selective state-space modeling. The proposed network enriches local vessel responses with progressive expansion, models long-range spatial dependencies through a Mamba Global Context (MGC) block with linear sequence complexity, and uses attention-based decoder fusion to recover fine vascular boundaries. We evaluate U-PEN Mamba on CHASE DB1 and DRIVE using a consistent patch-based preprocessing pipeline and compare it with convolutional, attention-based, transformer-based, and Mamba-based segmentation baselines. U-PEN Mamba obtains the best mean intersection over union among the compared methods, achieving 0.8394 on CHASE DB1 and 0.8221 on DRIVE, with Dice scores of 0.8187 and 0.8078, respectively, using 21.6M trainable parameters. Ablation studies show that the MGC block contributes the largest gain over the U-Net baseline, while projection dimension and state size provide practical accuracy-efficiency control. These results indicate that selective state-space modeling is a promising global-context mechanism for parameter-efficient retinal vessel segmentation. Code is available at: https://github.com/areyesan/UPEN_Mamba.

0.45

ORViT-DR: Ordinally-Robust Hybrid ViT for Low-Resolution Diabetic Retinopathy Grading

eess.IV cs.CV ·2026-08-16 ·Soumit Kumar Kundu, Nabil Ashab, Bidhan Biswas, Shahadat Hossain Sohag, Saif Mahmud Parvez +2 more
published similarity 0.68
Abstract · Accepted at ECCT 2026

Diabetic retinopathy (DR) is one of the main causes of impaired vision. A good and reliable automated grading system can make the screening process safer and more accurate. Because DR stages progress gradually, the task of grading disease severity naturally follows an ordinal structure in which neighboring classes share similar visual characteristics. In this study, ORViT-DR, a hybrid deep learning framework, is designed to improve DR grading from low-resolution retinal images. The proposed approach combines convolutional feature extraction with transformer-based global context modeling through a pre-trained ViT-Hybrid backbone, which integrates BiT-ResNetv2 with a Vision Transformer architecture. The approach is tested on the RetinaMNIST subset of the MedMNISTv2 dataset, which contains 28x28 retinal fundus images annotated with five levels of disease severity. To promote stable training and better feature learning, the training strategy applies progressive layer unfreezing, layer-wise learning rate decay, exponential moving average (EMA) parameter updates, and ensemble-based prediction during inference. Experimental results on the official RetinaMNIST test set show that the proposed method achieves 57.00% classification accuracy, along with a quadratic weighted kappa score of 0.5963 and a macro-F1 score of 0.4293. These results suggest that hybrid CNN-Transformer architectures can provide effective representations for ordinal retinal image analysis.

0.19

CNN-Based Retinal OCT Classification: Research Gap Analysis and a From-Scratch Baseline, ED126-A

cs.CV cs.LG ·2026-11-01 ·Shkelqim Sherifi
benchmark similarity 0.68
Abstract · 18 pages, 26 figures

Automated classification of retinal pathologies from Optical Coherence Tomography (OCT) images remains challenging because diagnostically relevant morphological patterns may exhibit substantial inter-class similarity. Although high classification accuracies have been reported on benchmark OCT datasets, cross-study comparison is limited by heterogeneous evaluation protocols and by the limited characterization of compact convolutional neural network (CNN) baselines trained from random initialization. This study addresses this gap through two contributions. First, it provides a focused review of CNN-based retinal OCT classification and identifies methodological considerations relevant to controlled benchmarking. Second, it presents ED126-A, a purpose-built four-class CNN baseline trained from scratch under a documented experimental protocol on the Kermany labeled OCT dataset. The model contains 1,241,380 total parameters, including 1,239,460 trainable parameters, and is evaluated using training-dynamics analysis, class-wise performance metrics, confusion-matrix analysis, confidence analysis, t-SNE representation-space visualization, Grad-CAM, hierarchical feature-map analysis, and one-vs-rest ROC/Precision-Recall analysis. On the image-level held-out test set, ED126-A achieved 95.03% accuracy, with a macro-F1 of 0.9205 and a weighted-F1 of 0.9521. The principal class-conditional limitation occurred for Drusen, which attained a recall of 0.9605 but a precision of 0.7493 and an F1-score of 0.8419. The confusion matrix identified Normal to Drusen and CNV to Drusen as major error channels. These results support the use of ED126-A as a documented from-scratch reference baseline and provide an empirical basis for controlled evaluation of transfer learning, increased depth, attention, multi-scale feature fusion, and calibration in subsequent studies.

0.30

FPG-Seg: Annotation-free Retinal Vessel Topology Segmentation

cs.CV ·2026-10-15 ·James Willoughby, Irina Voiculescu
benchmark similarity 0.68
Abstract

State-of-the art approaches to retinal vessel segmentation typically require extensive annotations, a highly time-consuming process, reliant on clinical expertise. We present FPG-Seg, an annotation-free pipeline for retinal vessel segmentation combining classical vesselness filtering, Bayesian deep learning and topology-aware graph reconstruction to segment retinal vessel topology without manual labels. Tested across four widely used benchmark datasets for retinal vessel segmentation, FPG-Seg attains a clDice of $0.74{-}0.78$, representing $86{-}98\%$ of the performance of an equivalent fully-supervised baseline, despite using no manual annotations for training or hyperparameter tuning. As part of this work, we also provide, to our knowledge, the first performance benchmark of an annotation-free vessel segmentation method on FIVES.

0.18

Promise and Limits of Cross-Architecture Knowledge Distillation for Lightweight Medical Vision Transformers (LiteMed-ViT)

cs.CV ·2026-10-24 ·Shuaibu Shehu, Elijah M. Flomo, Mohammad Safiya, Anurodh Kumar, Subodh Kumar
published similarity 0.67
Abstract · 6 pages, including references. Accepted at the International Conference on Intelligent Computing and Secure Communication Systems (ICICSCS 2…

Running deep models for medical image analysis at the point of care is challenging with standard architectures: convolutional neural networks (CNNs) are often too heavy for edge devices, while Vision Transformers (ViTs) require massive training datasets to compensate for missing inductive biases. This study investigates how far the dual-token distillation used to train data-efficient ViTs can be pushed when applied across architectures, from a CNN-based teacher into a lightweight ViT student. LiteMed-ViT is introduced as a dual-token ViT featuring a convolutional stem and a class-balanced distillation objective; at 0.234M parameters, LiteMed-ViT carries 47.8x fewer parameters than its ResNet18 teacher at a memory footprint of just 0.89 MB. Evaluated against three compact CNN baselines on three MedMNIST subsets of varying modality and class balance, LiteMed-ViT attains higher accuracy than all three baselines on BloodMNIST (95.05%) and two on PathMNIST (89.15%). Under MedMNIST-C corruptions, it is at least as robust as every compact CNN across all subsets, outperforming them on BloodMNIST and PathMNIST without declining in relative standing as severity increases. Particular attention is devoted to identifying the exact conditions where performance plateaus. On DermaMNIST, LiteMed-ViT's balanced accuracy remains up to 1.9 points below the strongest compact CNNs and does not benefit from higher input resolutions up to 224 pixels, where ResNet18 gains 12.6 points. Stronger teachers do not yield a more accurate student, and overconfident ones lower its DermaMNIST balanced accuracy unless calibrated.

0.27

Comparative Evaluation of Deep Learning Models for Geographic Atrophy Segmentation in En Face OCT Images

cs.CV ·2026-11-09 ·Utkarsh Doshi, Adarsh Gadari, Sharat Chandra Vupparaboina, Joseph DeCicco, Giulia Gregori +7 more
similarity 0.67
Abstract · 30 pages, 11 figures

Background: Geographic atrophy (GA) is an advanced form of age-related macular degeneration (AMD). It causes irreversible vision loss due to progressive degeneration of the retinal pigment epithelium (RPE) and photoreceptors. Accurate segmentation of GA in en-face image is crucial for early diagnosis, monitoring disease progression, and developing personalized treatment strategies. However, existing deep learning approaches are typically evaluated using single architectures and single-device datasets, limiting insight into relative performance and cross-device robustness. Methods: We trained and systematically compared five deep learning architectures for GA segmentation: Nested U-Net, ResU-Net, nnUnet, Swin-Unet and MedSegDiff model, together with a thresholding based classical baseline. The models were trained on a dataset of en-face OCT images derived from 269 OCT volumes from two different devices, following a three-step preprocessing technique involving normalization and inpainting to enhance the quality of the en-face images. Results: On the fixed held-out validation set comprising OCT scans from both Cirrus (R) (Carl Zeiss Meditec, Inc., USA) and Spectralis (R) (Heidelberg Engineering, Germany) devices, nnUnet achieved the highest mean Dice similarity coefficient (DSC) of 0.8882 +/- 0.0033. The other models yielded the following Dice scores: Nested U-Net (0.7932 +/- 0.0423), ResU-Net (0.8453 +/- 0.0074), Swin-Unet (0.6886 +/- 0.0294), and Diffusion model (0.7959 +/- 0.0242). Conclusions: nnUnet framework, demonstrated most reliable performance for GA segmentation in en-face OCT under limited data conditions. It offers the best balance of accuracy, stability, and efficiency for GA quantification.

0.20