CS Paper Radar

Promise and Limits of Cross-Architecture Knowledge Distillation for Lightweight Medical Vision Transformers (LiteMed-ViT)

Shuaibu Shehu, Elijah M. Flomo, Mohammad Safiya, Anurodh Kumar, Subodh Kumar

cs.CV ·submitted 2026-10-24 07:58 UTC · v1
published

Abstract

Running deep models for medical image analysis at the point of care is challenging with standard architectures: convolutional neural networks (CNNs) are often too heavy for edge devices, while Vision Transformers (ViTs) require massive training datasets to compensate for missing inductive biases. This study investigates how far the dual-token distillation used to train data-efficient ViTs can be pushed when applied across architectures, from a CNN-based teacher into a lightweight ViT student. LiteMed-ViT is introduced as a dual-token ViT featuring a convolutional stem and a class-balanced distillation objective; at 0.234M parameters, LiteMed-ViT carries 47.8x fewer parameters than its ResNet18 teacher at a memory footprint of just 0.89 MB. Evaluated against three compact CNN baselines on three MedMNIST subsets of varying modality and class balance, LiteMed-ViT attains higher accuracy than all three baselines on BloodMNIST (95.05%) and two on PathMNIST (89.15%). Under MedMNIST-C corruptions, it is at least as robust as every compact CNN across all subsets, outperforming them on BloodMNIST and PathMNIST without declining in relative standing as severity increases. Particular attention is devoted to identifying the exact conditions where performance plateaus. On DermaMNIST, LiteMed-ViT's balanced accuracy remains up to 1.9 points below the strongest compact CNNs and does not benefit from higher input resolutions up to 224 pixels, where ResNet18 gains 12.6 points. Stronger teachers do not yield a more accurate student, and overconfident ones lower its DermaMNIST balanced accuracy unless calibrated.

Comment
6 pages, including references. Accepted at the International Conference on Intelligent Computing and Secure Communication Systems (ICICSCS 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Pretraining and Distillation Matter More Than Architecture Family for Label-Free Single-Cell Classification

cs.CV ·2026-09-09 ·Philip Graemer, Giuseppe Di Caprio
benchmark similarity 0.72
Abstract · 25 pages, 3 figures

Choosing a deep learning architecture for label-free single-cell classification remains an open question, with microscopy benchmarks reporting conflicting conclusions about CNNs versus transformers. We present a controlled benchmark on LIVECell phase-contrast microscopy data using source-image-disjoint train/validation/test splits to prevent parent-image leakage and matched optimisation, augmentation, and evaluation protocols across EfficientNet, Vision Transformer (ViT), and EVA-02 models. This allows the effects of architecture, pretraining, fine-tuning, tokenisation, and distillation to be disentangled. We find that the previously reported CNN advantage is largely explained by pretraining rather than architecture: the smallest pretrained model outperforms the strongest model trained from scratch despite far fewer parameters. Pretraining improves macro-F1 by 3-4 points, while the gap between the best pretrained CNN and transformer is below 0.5 points. Architectural choices nevertheless matter: ViT-S/8 outperforms ViT-S/16 and matches the four-times-larger ViT-B/16 at a quarter of the parameters, showing that finer tokenisation benefits small cell crops. Conversely, layer-wise learning-rate decay, central to the EVA-02 fine-tuning recipe, degrades performance, highlighting that transfer heuristics from natural-image recognition may not generalise to microscopy. Finally, knowledge distillation substantially improves the deployment frontier: compact EfficientNet-B0 students distilled from teacher councils outperform every individually trained backbone, including the EfficientNet-B5 and EVA-02 teachers. Overall, our results show that rigorous control of pretraining and evaluation is essential for interpreting biomedical architecture benchmarks, while distillation may be a more effective route to practical single-cell classification than architecture choice alone.

0.21

Cross-Architecture Knowledge Distillation from a Vision Foundation Model to a Lightweight Visual State Space Model for Tea Leaf Disease Classification

cs.CV ·2026-08-27 ·Zibo Zhou, Zongsen Qiu, Rui Chen, Yujie Yao, Yue Zhou +1 more
similarity 0.71
Abstract

Automated tea leaf disease classification supports precision agriculture, yet deploying accurate models on edge devices remains challenging under tight compute budgets. Self-supervised vision foundation models such as DINOv2 provide strong features but are too large for field deployment, while lightweight models trained from scratch on small agricultural datasets often underfit. We study cross-architecture knowledge distillation (KD) from a fine-tuned DINOv2 teacher (Vision Transformer) to a compact bidirectional Visual State Space Model (LVSSM) student, an underexplored direction because the architectures use fundamentally different token-mixing mechanisms. We identify and fix two training-stability problems that prevent the from-scratch SSM student from learning on limited data: a single large patch-embedding convolution and a fusion layer that severs the residual path. With a progressive convolutional stem and gated bidirectional selective-scan block, the 4.45M-parameter student trains stably. Across three seeds, temperature-scaled logit distillation raises test accuracy from 92.32+/-2.14% to 95.41+/-1.17% (best single run: 96.20%; macro-F1: 94.45%), a +3.09 percentage-point mean gain. The student uses 5.0 times fewer parameters than the 22M-parameter teacher while retaining 98.3% of its accuracy. Ablations show that intermediate feature-alignment losses reduce accuracy, making simple logit-level KD the strongest configuration. A fair from-scratch comparison shows the gain is specific to students that start below the teacher. We report per-class metrics, confusion matrices, bootstrap confidence intervals, and FLOPs/latency measurements, and discuss limitations including the single-dataset scope and simplified non-official SSM implementation.

0.16

CAMEL: Cross-Architecture Masked Embedding Learning for Ultra-Lightweight Retinal Foundation Models

cs.LG cs.AIcs.CV ·2026-10-29 ·Andre Guarnier De Mitri, Giovani Decico Lucafo, Miller Matheus Lima Anacleto Rocha, Diego Furtado Silva
similarity 0.70
Abstract · 8 pages, 6 figures, pre-print

Recent progress in deep learning has substantially advanced automated grading of ophthalmologic pathologies, supported by large annotated datasets and improved representation learning. However, a significant gap remains between state-of-the-art performance and clinical scalability. In particular, foundation models have reshaped image-based medical screening and diagnosis. These large-scale architectures trained on extensive datasets learn rich, generalizable feature representations that can be adapted to a wide range of downstream tasks. In ophthalmology, RETFound, one of the most relevant foundation models for retinal images, performs strongly across classification, segmentation, and risk prediction tasks. Despite their effectiveness, foundation models are often computationally prohibitive, hindering their deployment in real-world clinical environments where hardware constraints and latency are critical. To bridge this gap, we introduce CAMEL (Cross-Architecture Masked Embedding Learning), a novel cross-architecture distillation framework that uses an asymmetric masking strategy during embedding learning to effectively transfer knowledge from massive teacher foundation models to compact, lightweight student models. Our experimental evaluation across four datasets shows that CAMEL preserves accuracy while drastically reducing computational complexity, enabling lightweight yet highly accurate models suitable for resource-limited clinical settings.

0.21

How Robust Are CNNs and Vision Transformers for Alzheimer's MRI Classification Across Datasets?

cs.CV ·2026-10-24 ·Hafija Aktar, Molly Croes, Frank S. Menniti, Abdeltawab Hendawi
dataset similarity 0.69
Abstract · 12 pages, 9 tables, 3 figures. Submitted to Biomedical Signal Processing and Control

Accurate assessment of Alzheimer's disease stages from MRI is important for understanding disease progression and supporting the development of computer-aided analysis tools. Deep learning models have shown promising results for Alzheimer's disease classification from MRI. However, when evaluated on single datasets, it is difficult to determine whether the observed performance reflects consistent architectural behavior or dataset-specific effects. In this work, we present a multi-dataset benchmarking framework with standardized preprocessing and evaluation. We compare five architectures: ResNet-50, ReXNet-150, Swin Transformer, ViT-Base, and ViT-Large. The models are evaluated across three MRI datasets representing severe class imbalance, train-test distribution mismatch, and large-scale augmentation. The results show broadly consistent performance patterns across datasets, with ViT-Large achieving the best performance on all three datasets and reaching up to 99.84% accuracy and 99.86% macro F1. Performance differences between architectures are most pronounced under distribution mismatch and considerably smaller in the augmented-data setting. Across datasets, lower class-level performance is observed primarily among adjacent early-stage categories, particularly Very Mild and Mild impairment. These findings highlight the importance of evaluating deep learning architectures across multiple data conditions rather than relying on single-dataset performance.

0.20

Grid-Preserving Knowledge Distillation: Transferring Convolutional Inductive Bias to Vision Transformers under Data Scarcity

cs.CV ·2026-08-11 ·Junyong Choi, Cheolhyeon Park, Jaehoon Cho
similarity 0.69
Abstract

Vision Transformers demonstrate remarkable global modeling capacity but often underperform in data-scarce regimes. Distilling convolutional inductive biases from a CNN teacher provides an effective remedy while leaving the deployed model unchanged. However, general-purpose feature distillation transfers little in this setting. In CNN-to-CNN distillation, pooling, flattening, and logit-space projections remove the spatial grid that encodes locality and translation equivariance. Unlike a convolutional student, a ViT cannot readily reconstruct this structure on its own. In this paper, we propose iBKD, a distillation framework that preserves the spatial grid throughout the entire transfer process. Its core module, the Inductive Bias Attention Module, aggregates features from all student layers onto the teacher's grid using learned weights. It then enhances structural cues through channel and deformable spatial attention and injects them via convolutional cross-attention operating directly between spatial grids rather than token sets. The module is used only during training, leaving the deployed model as an unmodified ViT with no inference overhead. Across seven Transformer backbones and six data-scarce benchmarks, iBKD consistently outperforms both locality-guidance methods and general knowledge distillation baselines, with its advantage increasing as the amount of training data decreases.

0.04

ORViT-DR: Ordinally-Robust Hybrid ViT for Low-Resolution Diabetic Retinopathy Grading

eess.IV cs.CV ·2026-08-16 ·Soumit Kumar Kundu, Nabil Ashab, Bidhan Biswas, Shahadat Hossain Sohag, Saif Mahmud Parvez +2 more
published similarity 0.67
Abstract · Accepted at ECCT 2026

Diabetic retinopathy (DR) is one of the main causes of impaired vision. A good and reliable automated grading system can make the screening process safer and more accurate. Because DR stages progress gradually, the task of grading disease severity naturally follows an ordinal structure in which neighboring classes share similar visual characteristics. In this study, ORViT-DR, a hybrid deep learning framework, is designed to improve DR grading from low-resolution retinal images. The proposed approach combines convolutional feature extraction with transformer-based global context modeling through a pre-trained ViT-Hybrid backbone, which integrates BiT-ResNetv2 with a Vision Transformer architecture. The approach is tested on the RetinaMNIST subset of the MedMNISTv2 dataset, which contains 28x28 retinal fundus images annotated with five levels of disease severity. To promote stable training and better feature learning, the training strategy applies progressive layer unfreezing, layer-wise learning rate decay, exponential moving average (EMA) parameter updates, and ensemble-based prediction during inference. Experimental results on the official RetinaMNIST test set show that the proposed method achieves 57.00% classification accuracy, along with a quadratic weighted kappa score of 0.5963 and a macro-F1 score of 0.4293. These results suggest that hybrid CNN-Transformer architectures can provide effective representations for ordinal retinal image analysis.

0.19

Evaluating SAM-based and Convolutional Architectures in Thin Retinal Vessel Segmentation: Model Capacity, Computational Cost and Foundation Pre-training

cs.CV ·2026-10-30 ·Carlos Eduardo Fontaneli, Cesar Henrique Comin
similarity 0.67
Abstract

In retinal vessel segmentation, plain Vision Transformers (ViTs) are commonly expected to perform worse than convolutional neural networks (CNNs) on thin vessels, for reasons such as their coarse patch tokenization, their weak locality bias and their need for large training sets. Although this expectation is widely shared in the literature, how plain ViTs actually compare with CNNs on thin vessels has not been systematically quantified. We address this question by comparing a model with a plain ViT encoder (MedSAM), a hybrid Transformer (LiteMedSAM) and three CNNs of different sizes on three retinal datasets (DRIVE, HRF, FIVES) and, as a second-domain check, a microscopy dataset (VessMap). We measured the centerline recall and precision of thin vessels and compared the models while also considering their computational cost and how many epochs they needed to train. We found that the pre-trained MedSAM had a centerline recall of thin vessels that was not significantly different from that of the best CNN on all four datasets (-0.6 to +2.5 percentage points). A compact plain ViT obtained through architecture search but trained from scratch did not retain this performance. For pre-trained plain ViTs, our results do not support the expectation that they miss thin vessels, although similar thin-vessel performance can be obtained with much smaller models.

0.23

CODI: Improving Self-Supervised Vision Transformers with Cross Distillation

cs.CV ·2026-10-22 ·Siran Dai, Qianqian Xu, Peisong Wen, Yang Liu, Xiaochun Cao +1 more
code/data similarity 0.67
Abstract · 35 pages, 11 figures, 14 tables

Self-supervised Vision Transformers learn strong image-level representations, but their patch-level representations can be unreliable for dense prediction. We study this mismatch and find that the class token concentrates global semantics on a small number of representative patches, while dense prediction errors often occur on low-attention regions. We provide a local gradient analysis showing that, along the [CLS] attention readout, image-level self-distillation gradients are weighted by [CLS]-to-patch attention mass. To provide masked patches with global semantics without changing the architecture, we propose Cross Distillation (CODI), which mixes a small amount of the teacher class-token distribution into each teacher patch-token target. CODI gives every masked patch an attention-independent semantic correction while preserving the standard self-distillation architecture. Experiments on dense and image-level benchmarks show that CODI improves both dense and image-level performance under aligned pretraining settings. Code is available at https://github.com/EldercatSAM/CODI.

0.26