CS Paper Radar

CNN-Based Retinal OCT Classification: Research Gap Analysis and a From-Scratch Baseline, ED126-A

Shkelqim Sherifi

cs.CV cs.LG ·submitted 2026-11-01 18:43 UTC · v1
benchmark

Abstract

Automated classification of retinal pathologies from Optical Coherence Tomography (OCT) images remains challenging because diagnostically relevant morphological patterns may exhibit substantial inter-class similarity. Although high classification accuracies have been reported on benchmark OCT datasets, cross-study comparison is limited by heterogeneous evaluation protocols and by the limited characterization of compact convolutional neural network (CNN) baselines trained from random initialization. This study addresses this gap through two contributions. First, it provides a focused review of CNN-based retinal OCT classification and identifies methodological considerations relevant to controlled benchmarking. Second, it presents ED126-A, a purpose-built four-class CNN baseline trained from scratch under a documented experimental protocol on the Kermany labeled OCT dataset. The model contains 1,241,380 total parameters, including 1,239,460 trainable parameters, and is evaluated using training-dynamics analysis, class-wise performance metrics, confusion-matrix analysis, confidence analysis, t-SNE representation-space visualization, Grad-CAM, hierarchical feature-map analysis, and one-vs-rest ROC/Precision-Recall analysis. On the image-level held-out test set, ED126-A achieved 95.03% accuracy, with a macro-F1 of 0.9205 and a weighted-F1 of 0.9521. The principal class-conditional limitation occurred for Drusen, which attained a recall of 0.9605 but a precision of 0.7493 and an F1-score of 0.8419. The confusion matrix identified Normal to Drusen and CNV to Drusen as major error channels. These results support the use of ED126-A as a documented from-scratch reference baseline and provide an empirical basis for controlled evaluation of transfer learning, increased depth, attention, multi-scale feature fusion, and calibration in subsequent studies.

Comment
18 pages, 26 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Within-Family EfficientNet Scaling under Fixed-Resolution Transfer Learning for Spectral-Domain Optical Coherence Tomography Retinal Disease Classification

cs.CV cs.AIcs.LG ·2026-11-04 ·Shkelqim Sherifi
similarity 0.73
Abstract · 46 pages, 20 figures, 18 tables

Background/Objectives: CNNs perform well in retinal disease classification from spectral-domain optical coherence tomography (SD-OCT), but whether EfficientNet's natural-image scaling hierarchy transfers to medical-image transfer learning at fixed resolution remains unclear. This study evaluates EfficientNet-B0-B7 for four-class SD-OCT classification and accuracy-efficiency trade-offs. Methods: Eight ImageNet-pretrained variants (4.05-64.10M instantiated backbone parameters) were evaluated at 224x224 on the Kermany dataset. Grayscale images were replicated to RGB and processed using model-embedded preprocessing and augmentation. Training comprised frozen-backbone head training followed by partial fine-tuning. Metrics covered classification, discrimination, efficiency, and visual analyses. Results: Test accuracy varied non-monotonically from 95.93% (B0) to 96.95% (B1); B7 achieved 96.73%. B1 had the highest accuracy and Drusen F1 (0.8780), while B7 had Drusen F1 of 0.8720 and the highest Drusen recall (0.9177). Drusen had the lowest F1 across all variants and contributed 82.2% of the summed squared deviation in class-specific F1; class ranking remained Normal > CNV > DME > Drusen. The OCT accuracy ranking differed from the reported ImageNet hierarchy, where B7 ranked first. The accuracy-to-parameter ratio fell from 19.82 to 1.48 percentage points per million total parameters. The final train-test gap had a weak, non-significant association with test accuracy (r = 0.26, p = 0.53). Conclusions: Larger EfficientNet variants did not consistently improve SD-OCT classification. B1 achieved the highest accuracy and Drusen F1, whereas B7 showed a secondary accuracy recovery at greater model size and CPU latency, indicating task and protocol dependent scaling effects. As cross-partition duplicates have not been independently audited, results are conditional on the supplied split.

0.13

Learning Pathology-Sensitive Representations for Unsupervised Retinal OCT Anomaly Detection

cs.CV cs.LG ·2026-10-23 ·Tania Haghighi, Sina Gholami, Behafarin Emam, Jennifer I Lim, Theodore Leng +3 more
similarity 0.69
Abstract

Deep learning approaches for retinal optical coherence tomography (OCT) predominantly rely on predefined disease categories, limiting their ability to detect rare or previously unseen abnormalities. While visual foundation models provide transferable representations, their effectiveness in identifying pathological deviations from normal retinal anatomy remains insufficiently understood. In this work, we introduce an unsupervised framework for retinal OCT anomaly detection and localization that adapts pretrained visual representations to normal retinal anatomy through anatomy-aware reconstruction and contrastive triplet learning guided by synthetic structural perturbations, without requiring disease-specific annotations. We systematically investigate the influence of pretraining strategies, anatomy-aware representation adaptation, and anomaly scoring mechanisms on the detection and localization of unseen retinal abnormalities. Our findings demonstrate that adapting pretrained representations to normal retinal structure improves anomaly sensitivity, while pixel-space reconstruction errors and feature-space deviations provide complementary signals for identifying pathological changes. These findings underscore the importance of anatomy-aware representation learning and offer insights into developing generalizable retinal anomaly detection frameworks beyond predefined disease categories.

0.30

Evaluating SAM-based and Convolutional Architectures in Thin Retinal Vessel Segmentation: Model Capacity, Computational Cost and Foundation Pre-training

cs.CV ·2026-10-30 ·Carlos Eduardo Fontaneli, Cesar Henrique Comin
similarity 0.68
Abstract

In retinal vessel segmentation, plain Vision Transformers (ViTs) are commonly expected to perform worse than convolutional neural networks (CNNs) on thin vessels, for reasons such as their coarse patch tokenization, their weak locality bias and their need for large training sets. Although this expectation is widely shared in the literature, how plain ViTs actually compare with CNNs on thin vessels has not been systematically quantified. We address this question by comparing a model with a plain ViT encoder (MedSAM), a hybrid Transformer (LiteMedSAM) and three CNNs of different sizes on three retinal datasets (DRIVE, HRF, FIVES) and, as a second-domain check, a microscopy dataset (VessMap). We measured the centerline recall and precision of thin vessels and compared the models while also considering their computational cost and how many epochs they needed to train. We found that the pre-trained MedSAM had a centerline recall of thin vessels that was not significantly different from that of the best CNN on all four datasets (-0.6 to +2.5 percentage points). A compact plain ViT obtained through architecture search but trained from scratch did not retain this performance. For pre-trained plain ViTs, our results do not support the expectation that they miss thin vessels, although similar thin-vessel performance can be obtained with much smaller models.

0.23

Domain-Specific Self-Supervised Representation Learning for Retinal Fundus Classification

cs.CV cs.LG ·2026-08-27 ·Bekzat Nurlanbekova, Fung Fung Ting
similarity 0.66
Abstract

Annotated medical images remain scarce and costly to obtain, which motivates self-supervised learning (SSL). We present a controlled empirical study of two SSL frameworks, SimSiam and SimCLR, for retinal fundus classification, asking whether retina-specific augmentations (Graham's local-mean subtraction and CLAHE) improve representations beyond standard augmentation and grayscale conversion. ResNet-18 backbones are pretrained on 48K unlabeled fundus images and evaluated by linear probing and fine-tuning on EDID (multi-disease) and RetinaMNIST (DR grading). On EDID, grayscale conversion accounts for most of SimSiam's linear-probe gain, and Graham or CLAHE add little on top of it. After fine-tuning, SimSiam with Graham+Gray exceeds an ImageNet-supervised baseline on RetinaMNIST (+3.0 accuracy points) but only matches it on EDID. Retina-specific augmentation therefore helps inconsistently and should be validated per SSL method and task.

0.14

Augmentation Strategy for DINO in Glaucoma Classification

cs.CV ·2026-10-23 ·Ashish Kumar Meena, Chandra Sekhar Seelamantula
publishedbenchmarkcode/data similarity 0.65
Abstract · 11 pages, 3 figures. Accepted at the 17th International Workshop on Machine Learning in Medical Imaging (MLMI 2026), held in conjunction wit…

Self-supervised learning (SSL) offers a promising approach to medical image representation learning, yet augmentation strategies of SSL frameworks validated on natural images do not reliably transfer to specialized medical imaging domains. We analyze DINO, a knowledge-distillation based SSL framework, and empirically demonstrate that its default augmentation strategy produces unreliable representations for retinal fundus images, degrading downstream glaucoma classification performance. Guided by the principle that effective cropped views should share minimal redundant information while retaining clinically relevant signal, we redesign DINO's augmentation strategy. Our approach biases the learned representations toward diagnostically critical features rather than low-level image statistics. We evaluate our method for glaucoma classification by training a linear classifier on the frozen representations, achieving strong generalization across seven benchmark datasets. URL for code and weights: https://github.com/ashish-256/task_dino

0.43

International Multi-Centre Validation of Unsupervised Domain Adaptation for Precise Discrimination between Normal and Abnormal Retinal Development

cs.CV cs.LG ·2026-10-15 ·Zhanhan Tu, Nikhil Reddy, Helen J. Kuht, Ha-Jun Yoon, Gail D. E. Maconachie +25 more
similarity 0.64
Abstract · Submitted to Nature Medicine. 38 pages, 6 figures, 2 tables. Supplementary material includes 3 figures and 3 tables

Arrested retinal development can cause childhood visual impairment, but grading optical coherence tomography scans is difficult to standardise across devices and centres. We developed and evaluated an unsupervised domain adaptation model to classify normal and abnormal retinal development across different OCT systems. This retrospective multicentre study used OCT scans from five centres in four countries and the UK Biobank. Data covered four OCT devices, including table mounted and handheld systems. A ResNet50 based Domain Adversarial Neural Network was trained using labelled images from a source device and unlabelled images from a target device. We evaluated six source to target pairings and compared model performance with seven clinician graders. A separate Heidelberg Spectralis dataset was reserved for external evaluation. Across validation sets, accuracy ranged from 87.75% to 96.06%, sensitivity from 88.68% to 98.38%, and specificity from 78.00% to 98.02%. The best performing model, adapted from TM OCT1 to HH OCT1, achieved 96.06% accuracy and an area under the receiver operating characteristic curve of 0.994, with a 95% confidence interval from 0.981 to 0.999. Several models also maintained discrimination on the unseen Heidelberg device. Unsupervised domain adaptation enabled OCT classification across devices without labelled target device data. The approach may support more consistent assessment of retinal development and large scale analysis of existing imaging datasets.

0.34

Comparative Evaluation of Deep Learning Models for Geographic Atrophy Segmentation in En Face OCT Images

cs.CV ·2026-11-09 ·Utkarsh Doshi, Adarsh Gadari, Sharat Chandra Vupparaboina, Joseph DeCicco, Giulia Gregori +7 more
similarity 0.63
Abstract · 30 pages, 11 figures

Background: Geographic atrophy (GA) is an advanced form of age-related macular degeneration (AMD). It causes irreversible vision loss due to progressive degeneration of the retinal pigment epithelium (RPE) and photoreceptors. Accurate segmentation of GA in en-face image is crucial for early diagnosis, monitoring disease progression, and developing personalized treatment strategies. However, existing deep learning approaches are typically evaluated using single architectures and single-device datasets, limiting insight into relative performance and cross-device robustness. Methods: We trained and systematically compared five deep learning architectures for GA segmentation: Nested U-Net, ResU-Net, nnUnet, Swin-Unet and MedSegDiff model, together with a thresholding based classical baseline. The models were trained on a dataset of en-face OCT images derived from 269 OCT volumes from two different devices, following a three-step preprocessing technique involving normalization and inpainting to enhance the quality of the en-face images. Results: On the fixed held-out validation set comprising OCT scans from both Cirrus (R) (Carl Zeiss Meditec, Inc., USA) and Spectralis (R) (Heidelberg Engineering, Germany) devices, nnUnet achieved the highest mean Dice similarity coefficient (DSC) of 0.8882 +/- 0.0033. The other models yielded the following Dice scores: Nested U-Net (0.7932 +/- 0.0423), ResU-Net (0.8453 +/- 0.0074), Swin-Unet (0.6886 +/- 0.0294), and Diffusion model (0.7959 +/- 0.0242). Conclusions: nnUnet framework, demonstrated most reliable performance for GA segmentation in en-face OCT under limited data conditions. It offers the best balance of accuracy, stability, and efficiency for GA quantification.

0.20

A Visual Grounding Benchmark for Retinal OCT with Multimodal Large Language Models

cs.CV ·2026-10-22 ·Ronald Fecso, José Morano, Botond Fazekas, Paul Widmann-Sedlnitzky, Dorota Himel +4 more
benchmarkcode/data similarity 0.63
Abstract · Under review at npj digital medicine

Multimodal large language models (MLLMs) can answer clinical questions about medical images, but trustworthy use requires visual grounding: models should localize the pathology they report rather than rely on spurious shortcuts. Whether MLLMs can visually ground clinical findings in retinal optical coherence tomography (OCT), the most widely used imaging modality in ophthalmology, remains largely unexplored. To address this gap, we introduce RetinaGroundBench, the first benchmark for biomarker visual grounding in retinal OCT. It comprises 815 B-scans exhaustively annotated by ophthalmologists with 4,537 bounding boxes covering 13 biomarkers across 8 diseases. Because MLLMs often fragment a single lesion into multiple partial predictions, we propose AggIoU, a metric that evaluates whether the union of overlapping predicted boxes covers the annotated region. Across 27 open-source MLLMs (0.8-38B parameters), we find that visual grounding remains largely unsolved: the best general-purpose model achieves a macro F1 of just 23.7%, with consistently low recall, despite reaching up to 73% balanced accuracy on biomarker presence questions. To narrow this gap, we developed RetGrounder, an MLLM fine-tuned using an OCT-specific strategy integrating grounding and textual information. Despite its relatively small size (8B), RetGrounder improves grounding F1 to 33.9%, a 43% relative improvement. Our benchmark provides a reference point for measuring progress in the field of OCT diagnosis with MLLMs.

0.30