CS Paper Radar

International Multi-Centre Validation of Unsupervised Domain Adaptation for Precise Discrimination between Normal and Abnormal Retinal Development

Zhanhan Tu, Nikhil Reddy, Helen J. Kuht, Ha-Jun Yoon, Gail D. E. Maconachie, Ravi Purohit, Prateek Pani, Line Kessel, Jinu Han, Jing Jin, Shui-Hua Wang, Karthik Bharadwaj, Viral Sheth, Michael Hisaund, Rebecca J. McLean, George Garratt, Chetan Kantibhai Patel, Kanmin Xue, Callum Hunt, Zisen Zhou, Ian De Silva, Seema Teli, Sonal Shah, Vanessa Rodwell, Aarti Patel, Irene Gottlob, Yu-Dong Zhang, Zedong Zheng, Girish Varma, Mervyn G. Thomas

cs.CV cs.LG ·submitted 2026-10-15 11:39 UTC · v1

Abstract

Arrested retinal development can cause childhood visual impairment, but grading optical coherence tomography scans is difficult to standardise across devices and centres. We developed and evaluated an unsupervised domain adaptation model to classify normal and abnormal retinal development across different OCT systems. This retrospective multicentre study used OCT scans from five centres in four countries and the UK Biobank. Data covered four OCT devices, including table mounted and handheld systems. A ResNet50 based Domain Adversarial Neural Network was trained using labelled images from a source device and unlabelled images from a target device. We evaluated six source to target pairings and compared model performance with seven clinician graders. A separate Heidelberg Spectralis dataset was reserved for external evaluation. Across validation sets, accuracy ranged from 87.75% to 96.06%, sensitivity from 88.68% to 98.38%, and specificity from 78.00% to 98.02%. The best performing model, adapted from TM OCT1 to HH OCT1, achieved 96.06% accuracy and an area under the receiver operating characteristic curve of 0.994, with a 95% confidence interval from 0.981 to 0.999. Several models also maintained discrimination on the unseen Heidelberg device. Unsupervised domain adaptation enabled OCT classification across devices without labelled target device data. The approach may support more consistent assessment of retinal development and large scale analysis of existing imaging datasets.

Comment
Submitted to Nature Medicine. 38 pages, 6 figures, 2 tables. Supplementary material includes 3 figures and 3 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Domain-Specific Self-Supervised Representation Learning for Retinal Fundus Classification

cs.CV cs.LG ·2026-08-27 ·Bekzat Nurlanbekova, Fung Fung Ting
similarity 0.69
Abstract

Annotated medical images remain scarce and costly to obtain, which motivates self-supervised learning (SSL). We present a controlled empirical study of two SSL frameworks, SimSiam and SimCLR, for retinal fundus classification, asking whether retina-specific augmentations (Graham's local-mean subtraction and CLAHE) improve representations beyond standard augmentation and grayscale conversion. ResNet-18 backbones are pretrained on 48K unlabeled fundus images and evaluated by linear probing and fine-tuning on EDID (multi-disease) and RetinaMNIST (DR grading). On EDID, grayscale conversion accounts for most of SimSiam's linear-probe gain, and Graham or CLAHE add little on top of it. After fine-tuning, SimSiam with Graham+Gray exceeds an ImageNet-supervised baseline on RetinaMNIST (+3.0 accuracy points) but only matches it on EDID. Retina-specific augmentation therefore helps inconsistently and should be validated per SSL method and task.

0.14

Robust retinal biometrics for patient identity verification and retrieval across age and imaging devices

cs.CV ·2026-08-31 ·Jose D. Vargas-Quiros, Dennis Bontempi, Jeroen Vermeulen, Bart Liefers, Sven Bergmann +1 more
similarity 0.69
Abstract

Patient identity errors can compromise longitudinal medical records, research databases, and downstream clinical decisions. We present a retinal biometric system for verifying claimed identities and retrieving the correct identity from color fundus images. We trained a 512-dimensional metric-learning encoder combining a ConvNeXtV2 backbone with ArcFace and triplet losses on 227,004 images from 21,851 patient-eye identities in the Rotterdam Study, spanning multiple imaging devices and up to 32.6 years of follow-up. The system was evaluated on held-out Rotterdam Study data and externally on the UK Biobank and Age-Related Eye Disease Study (AREDS). Before evaluation, we used the model to screen for identity inconsistencies and manually adjudicated flagged images, identifying incorrect assignments in 0.588% of Rotterdam Study images, 0.259% of UK Biobank images, and 0.164% of AREDS images. In retrospective-only verification after removing near-duplicate images, the system achieved AUROCs of 0.9998, 0.9997, and 0.9998 in the Rotterdam Study, UK Biobank, and AREDS, respectively. For identity retrieval using only previously acquired images, Recall@1 was 99.7%, 97.2%, and 97.6%, respectively, from galleries averaging 4436-8510 identities; the correct identity appeared among the top five results in at least 98.6% of cases. Performance remained robust across imaging devices and long follow-up intervals, while lower image quality and inconsistent retinal fields accounted for most failures. These findings establish retinal anatomy as a durable biometric signal, useful for safeguarding the integrity of longitudinal imaging records.

0.14

Within-Family EfficientNet Scaling under Fixed-Resolution Transfer Learning for Spectral-Domain Optical Coherence Tomography Retinal Disease Classification

cs.CV cs.AIcs.LG ·2026-11-04 ·Shkelqim Sherifi
similarity 0.68
Abstract · 46 pages, 20 figures, 18 tables

Background/Objectives: CNNs perform well in retinal disease classification from spectral-domain optical coherence tomography (SD-OCT), but whether EfficientNet's natural-image scaling hierarchy transfers to medical-image transfer learning at fixed resolution remains unclear. This study evaluates EfficientNet-B0-B7 for four-class SD-OCT classification and accuracy-efficiency trade-offs. Methods: Eight ImageNet-pretrained variants (4.05-64.10M instantiated backbone parameters) were evaluated at 224x224 on the Kermany dataset. Grayscale images were replicated to RGB and processed using model-embedded preprocessing and augmentation. Training comprised frozen-backbone head training followed by partial fine-tuning. Metrics covered classification, discrimination, efficiency, and visual analyses. Results: Test accuracy varied non-monotonically from 95.93% (B0) to 96.95% (B1); B7 achieved 96.73%. B1 had the highest accuracy and Drusen F1 (0.8780), while B7 had Drusen F1 of 0.8720 and the highest Drusen recall (0.9177). Drusen had the lowest F1 across all variants and contributed 82.2% of the summed squared deviation in class-specific F1; class ranking remained Normal > CNV > DME > Drusen. The OCT accuracy ranking differed from the reported ImageNet hierarchy, where B7 ranked first. The accuracy-to-parameter ratio fell from 19.82 to 1.48 percentage points per million total parameters. The final train-test gap had a weak, non-significant association with test accuracy (r = 0.26, p = 0.53). Conclusions: Larger EfficientNet variants did not consistently improve SD-OCT classification. B1 achieved the highest accuracy and Drusen F1, whereas B7 showed a secondary accuracy recovery at greater model size and CPU latency, indicating task and protocol dependent scaling effects. As cross-partition duplicates have not been independently audited, results are conditional on the supplied split.

0.13

CNN-Based Retinal OCT Classification: Research Gap Analysis and a From-Scratch Baseline, ED126-A

cs.CV cs.LG ·2026-11-01 ·Shkelqim Sherifi
benchmark similarity 0.64
Abstract · 18 pages, 26 figures

Automated classification of retinal pathologies from Optical Coherence Tomography (OCT) images remains challenging because diagnostically relevant morphological patterns may exhibit substantial inter-class similarity. Although high classification accuracies have been reported on benchmark OCT datasets, cross-study comparison is limited by heterogeneous evaluation protocols and by the limited characterization of compact convolutional neural network (CNN) baselines trained from random initialization. This study addresses this gap through two contributions. First, it provides a focused review of CNN-based retinal OCT classification and identifies methodological considerations relevant to controlled benchmarking. Second, it presents ED126-A, a purpose-built four-class CNN baseline trained from scratch under a documented experimental protocol on the Kermany labeled OCT dataset. The model contains 1,241,380 total parameters, including 1,239,460 trainable parameters, and is evaluated using training-dynamics analysis, class-wise performance metrics, confusion-matrix analysis, confidence analysis, t-SNE representation-space visualization, Grad-CAM, hierarchical feature-map analysis, and one-vs-rest ROC/Precision-Recall analysis. On the image-level held-out test set, ED126-A achieved 95.03% accuracy, with a macro-F1 of 0.9205 and a weighted-F1 of 0.9521. The principal class-conditional limitation occurred for Drusen, which attained a recall of 0.9605 but a precision of 0.7493 and an F1-score of 0.8419. The confusion matrix identified Normal to Drusen and CNV to Drusen as major error channels. These results support the use of ED126-A as a documented from-scratch reference baseline and provide an empirical basis for controlled evaluation of transfer learning, increased depth, attention, multi-scale feature fusion, and calibration in subsequent studies.

0.30

FOCUS: Benchmarking Retinal Model Generalization from Foundation Vision Encoders to Multimodal LLMs

cs.CV cs.AI ·2026-09-27 ·David Restrepo, Chenwei Wu, Luis Filipe Nakayama, Miguel L. Martins, Stergios Christodoulidis +2 more
top venuebenchmarkdatasetcode/data similarity 0.64
Abstract · Accepted at NeurIPS 2026, Evaluations & Datasets Track. Interactive benchmark dashboard: https://huggingface.co/spaces/dsrestrepo/FOCUS-Reti…

Progress in AI-based retinal image analysis has accelerated with the adoption of foundation models, yet evaluating their real-world reliability remains challenging. Performance reported on a single dataset does not capture how models behave under dataset shift, across clinical definitions, or for different patient subgroups. This limitation is particularly critical in medical imaging, where robustness, calibration, and fairness are essential for safe deployment. We introduce FOCUS (Foundation Ophthalmic Cross-Dataset Understanding under Shift), a cross-dataset benchmark evaluating retinal fundus models across vision-only encoder models (VM), vision-language dual-encoder models (VLM), and multimodal large language models (MLLM). FOCUS harmonizes binary diabetic retinopathy, referable diabetic retinopathy, and glaucomatous optic neuropathy tasks across ten public datasets spanning diverse geographies, acquisition conditions, and label protocols. The benchmark evaluates models through a unified analysis layer that measures ranking performance, calibration, subgroup disparities, and image-quality robustness. We present a large-scale evaluation covering 532 base configurations and 228 MLLM configurations adapted via LoRA fine-tuning. Results show no model family consistently dominates across tasks and datasets: general VM encoders achieve the strongest average ranking performance, medical MLLMs are competitive but variable, and dual-encoder VLMs benefit substantially from lightweight adaptation. Fine-tuning improves in-domain performance but exhibits heterogeneous transfer to external datasets, particularly in calibration. FOCUS provides a practical framework and public benchmark to assess generalization, reliability, and robustness beyond single-dataset leaderboards.

0.52

Explainable Diabetic Retinopathy Classification Using Vision Foundation Models

cs.CV cs.LG ·2026-08-28 ·Abhishek Verma, Anila Krishna, Abhishek Gajanan Bankar, Juan Miguel Lopez Alcaraz
code/data similarity 0.64
Abstract · 17 pages, 4 figures, source code under https://github.com/UOLMDA26/retinopathy_vision_foundational

Diabetic retinopathy (DR) is a leading cause of preventable blindness, and automated screening must be both accurate and trustworthy. We study an explainable DR classification framework built on vision foundation models and three transfer learning strategies. Three backbones, DINOv2, CLIP, and Vision Transformer (ViT), were adapted by full fine-tuning, linear probing, and Low-Rank Adaptation (LoRA). Models were trained and internally evaluated on the ODIR dataset and externally evaluated on APTOS to assess generalization. DINOv2-LoRA achieved the highest internal AUROC (0.758), whereas DINOv2 and ViT full fine-tuning achieved the highest external AUROC (0.920). Probability calibration was assessed with reliability analysis after isotonic regression. For explainability, Grad-CAM and HiResCAM maps were compared with expert-annotated lesion masks from the IDRiD dataset using Dice, Intersection over Union (IoU), and Pointing Game metrics. The results show that foundation models, particularly DINOv2, provide strong predictive performance, and that LoRA is a parameter-efficient alternative to full fine-tuning. Spatial overlap between explanation maps and annotated lesions was limited (mean Dice of about 0.13 for the combined lesion mask), which highlights the value of quantitatively testing whether model attention corresponds to clinically relevant retinal lesions.

0.23

Interpretable Fundus Image Classification via Ring-Based Retinal Vasculature Features

cs.CV stat.ML ·2026-08-25 ·Xiaoyan Li, Shixin Xu, Arvind Gupta, Huaxiong Huang
similarity 0.63
Abstract

Retinal fundus photography is widely used for screening and monitoring ocular diseases, but many modern classification pipelines rely on deep latent representations and provide limited interpretability. This study develops an interpretable fundus image classification framework based on a ring-structured representation of the retinal vasculature centered on the optic disc. The method quantifies vessel geometry, color appearance, oxygenation-related vascular appearance, and vessel--background entropy within concentric retinal regions. These physiologically motivated descriptors are derived from vessel masks, image intensities, and optical-density measurements and aggregated across rings to capture spatial variation in vascular properties. Using only quantitative vascular descriptors, the proposed method achieved strong classification performance across three public fundus datasets. On HRF, it achieved 91.1\% accuracy using automatically generated vessel masks, matching RETFound, a vision transformer pretrained on large-scale retinal fundus image data, under the same evaluation setting. Additional analyses suggest that pretrained image models are sensitive to acquisition-related spatial cues, including fundus scale and retinal position within the field of view, as well as broader non-vessel image characteristics. This framework may support interpretable disease classification, quantitative retinal phenotyping, and retinal biomarker discovery without requiring large task-specific training datasets.

0.44

From Canon to Nikon: Camera Domain Shift and Potential Equity Implications in Retinal AI

cs.CV cs.CY ·2026-10-21 ·Lisa Y. W. Tang
similarity 0.63
Abstract

Diabetic retinopathy is a leading cause of preventable blindness, yet access to regular screening remains limited worldwide. AI offers a scalable approach, but its performance can be sensitive to image quality and acquisition conditions. In a Brazilian cohort of 8,524 patients, retinal images acquired with the Nikon NF5050 were more than twice as likely to have inadequate image quality compared with those acquired with the Canon CR-2, despite refurbished Canon systems costing more than twice as much as Nikon systems. This potential cost-quality trade-off highlights an important consideration for the reliability of AI systems deployed across heterogeneous imaging systems. Using a frozen pretrained retinal foundation model, we systematically evaluate whether camera-associated performance differences persist across 12 retinal disease classification tasks, four input resolutions, and five downstream classifiers. We find that camera-associated performance differences vary substantially across tasks, and that neither higher input resolution nor classifier choice consistently mitigates cross-camera variation. These findings identify camera platform as a potentially overlooked source of performance variability, with implications for the safety and reliability of retinal AI when deployed across heterogeneous imaging systems. We release all source code, evaluation scripts, and per-task results on GitHub to support reproducible benchmarking.

0.24