CS Paper Radar

Within-Family EfficientNet Scaling under Fixed-Resolution Transfer Learning for Spectral-Domain Optical Coherence Tomography Retinal Disease Classification

Shkelqim Sherifi

cs.CV cs.AIcs.LG ·submitted 2026-11-04 12:53 UTC · v1

Abstract

Background/Objectives: CNNs perform well in retinal disease classification from spectral-domain optical coherence tomography (SD-OCT), but whether EfficientNet's natural-image scaling hierarchy transfers to medical-image transfer learning at fixed resolution remains unclear. This study evaluates EfficientNet-B0-B7 for four-class SD-OCT classification and accuracy-efficiency trade-offs. Methods: Eight ImageNet-pretrained variants (4.05-64.10M instantiated backbone parameters) were evaluated at 224x224 on the Kermany dataset. Grayscale images were replicated to RGB and processed using model-embedded preprocessing and augmentation. Training comprised frozen-backbone head training followed by partial fine-tuning. Metrics covered classification, discrimination, efficiency, and visual analyses. Results: Test accuracy varied non-monotonically from 95.93% (B0) to 96.95% (B1); B7 achieved 96.73%. B1 had the highest accuracy and Drusen F1 (0.8780), while B7 had Drusen F1 of 0.8720 and the highest Drusen recall (0.9177). Drusen had the lowest F1 across all variants and contributed 82.2% of the summed squared deviation in class-specific F1; class ranking remained Normal > CNV > DME > Drusen. The OCT accuracy ranking differed from the reported ImageNet hierarchy, where B7 ranked first. The accuracy-to-parameter ratio fell from 19.82 to 1.48 percentage points per million total parameters. The final train-test gap had a weak, non-significant association with test accuracy (r = 0.26, p = 0.53). Conclusions: Larger EfficientNet variants did not consistently improve SD-OCT classification. B1 achieved the highest accuracy and Drusen F1, whereas B7 showed a secondary accuracy recovery at greater model size and CPU latency, indicating task and protocol dependent scaling effects. As cross-partition duplicates have not been independently audited, results are conditional on the supplied split.

Comment
46 pages, 20 figures, 18 tables

Closest papers

Nearest neighbours by meaning across the whole index.

CNN-Based Retinal OCT Classification: Research Gap Analysis and a From-Scratch Baseline, ED126-A

cs.CV cs.LG ·2026-11-01 ·Shkelqim Sherifi
benchmark similarity 0.73
Abstract · 18 pages, 26 figures

Automated classification of retinal pathologies from Optical Coherence Tomography (OCT) images remains challenging because diagnostically relevant morphological patterns may exhibit substantial inter-class similarity. Although high classification accuracies have been reported on benchmark OCT datasets, cross-study comparison is limited by heterogeneous evaluation protocols and by the limited characterization of compact convolutional neural network (CNN) baselines trained from random initialization. This study addresses this gap through two contributions. First, it provides a focused review of CNN-based retinal OCT classification and identifies methodological considerations relevant to controlled benchmarking. Second, it presents ED126-A, a purpose-built four-class CNN baseline trained from scratch under a documented experimental protocol on the Kermany labeled OCT dataset. The model contains 1,241,380 total parameters, including 1,239,460 trainable parameters, and is evaluated using training-dynamics analysis, class-wise performance metrics, confusion-matrix analysis, confidence analysis, t-SNE representation-space visualization, Grad-CAM, hierarchical feature-map analysis, and one-vs-rest ROC/Precision-Recall analysis. On the image-level held-out test set, ED126-A achieved 95.03% accuracy, with a macro-F1 of 0.9205 and a weighted-F1 of 0.9521. The principal class-conditional limitation occurred for Drusen, which attained a recall of 0.9605 but a precision of 0.7493 and an F1-score of 0.8419. The confusion matrix identified Normal to Drusen and CNV to Drusen as major error channels. These results support the use of ED126-A as a documented from-scratch reference baseline and provide an empirical basis for controlled evaluation of transfer learning, increased depth, attention, multi-scale feature fusion, and calibration in subsequent studies.

0.30

Domain-Specific Self-Supervised Representation Learning for Retinal Fundus Classification

cs.CV cs.LG ·2026-08-27 ·Bekzat Nurlanbekova, Fung Fung Ting
similarity 0.71
Abstract

Annotated medical images remain scarce and costly to obtain, which motivates self-supervised learning (SSL). We present a controlled empirical study of two SSL frameworks, SimSiam and SimCLR, for retinal fundus classification, asking whether retina-specific augmentations (Graham's local-mean subtraction and CLAHE) improve representations beyond standard augmentation and grayscale conversion. ResNet-18 backbones are pretrained on 48K unlabeled fundus images and evaluated by linear probing and fine-tuning on EDID (multi-disease) and RetinaMNIST (DR grading). On EDID, grayscale conversion accounts for most of SimSiam's linear-probe gain, and Graham or CLAHE add little on top of it. After fine-tuning, SimSiam with Graham+Gray exceeds an ImageNet-supervised baseline on RetinaMNIST (+3.0 accuracy points) but only matches it on EDID. Retina-specific augmentation therefore helps inconsistently and should be validated per SSL method and task.

0.14

LightHybridNet: A Lightweight Hybrid Deep Learning Framework for Efficient Multi-Label Ophthalmic Disease Classification in Imbalanced Fundus Images

eess.IV ·2026-10-14 ·Hem Raj Dadral Najam Ul Hasan, Naveed Ejaz, Muhammad Aslam Jarwar
similarity 0.68
Abstract

Eye diseases are a major global cause of blindness and vision impairment, highlighting the need for accurate and early diagnosis to prevent further deterioration. Despite advances in medical imaging, classifying retinal diseases from fundus images remains challenging due to the complexity and subtlety of visual features. This study aims to develop and validate LightHybridNet, a novel lightweight hybrid deep learning framework, to improve the classification of eye diseases from fundus images. The model incorporates architectural features, such as depthwise separable convolutions and compound scaling mechanisms, to enhance diagnostic accuracy and robustness. To validate the model, the ODIR-5K dataset, comprising 8 disease categories, was used. To enhance image quality, pre-processing approaches were applied, including histogram equalisation, colour space conversion, and contrast adjustment, resulting in high-resolution images. Furthermore, image augmentation was employed to increase the dataset size, thereby improving the model's ability to generalise during training. The hybrid architecture helps the model concentrate on relevant image regions while capturing and integrating details at different scales, significantly improving classification performance. To evaluate its effectiveness, the model was compared with transfer-learning models. The results show that LightHybridNet outperforms the baselines, achieving a weighted F1-score of 91.51%, a macro AUC of 98.26%, and a Cohen's Kappa of 90.14% on the validation set. Furthermore, model interpretability was enhanced using explainable AI methods, including Grad-CAM, to identify and emphasise features influencing the decision-making process. LightHybridNet represents a promising advancement in automated ocular disease detection, offering improved diagnostic reliability for clinical use.

0.20

International Multi-Centre Validation of Unsupervised Domain Adaptation for Precise Discrimination between Normal and Abnormal Retinal Development

cs.CV cs.LG ·2026-10-15 ·Zhanhan Tu, Nikhil Reddy, Helen J. Kuht, Ha-Jun Yoon, Gail D. E. Maconachie +25 more
similarity 0.68
Abstract · Submitted to Nature Medicine. 38 pages, 6 figures, 2 tables. Supplementary material includes 3 figures and 3 tables

Arrested retinal development can cause childhood visual impairment, but grading optical coherence tomography scans is difficult to standardise across devices and centres. We developed and evaluated an unsupervised domain adaptation model to classify normal and abnormal retinal development across different OCT systems. This retrospective multicentre study used OCT scans from five centres in four countries and the UK Biobank. Data covered four OCT devices, including table mounted and handheld systems. A ResNet50 based Domain Adversarial Neural Network was trained using labelled images from a source device and unlabelled images from a target device. We evaluated six source to target pairings and compared model performance with seven clinician graders. A separate Heidelberg Spectralis dataset was reserved for external evaluation. Across validation sets, accuracy ranged from 87.75% to 96.06%, sensitivity from 88.68% to 98.38%, and specificity from 78.00% to 98.02%. The best performing model, adapted from TM OCT1 to HH OCT1, achieved 96.06% accuracy and an area under the receiver operating characteristic curve of 0.994, with a 95% confidence interval from 0.981 to 0.999. Several models also maintained discrimination on the unseen Heidelberg device. Unsupervised domain adaptation enabled OCT classification across devices without labelled target device data. The approach may support more consistent assessment of retinal development and large scale analysis of existing imaging datasets.

0.34

CAMEL: Cross-Architecture Masked Embedding Learning for Ultra-Lightweight Retinal Foundation Models

cs.LG cs.AIcs.CV ·2026-10-29 ·Andre Guarnier De Mitri, Giovani Decico Lucafo, Miller Matheus Lima Anacleto Rocha, Diego Furtado Silva
similarity 0.64
Abstract · 8 pages, 6 figures, pre-print

Recent progress in deep learning has substantially advanced automated grading of ophthalmologic pathologies, supported by large annotated datasets and improved representation learning. However, a significant gap remains between state-of-the-art performance and clinical scalability. In particular, foundation models have reshaped image-based medical screening and diagnosis. These large-scale architectures trained on extensive datasets learn rich, generalizable feature representations that can be adapted to a wide range of downstream tasks. In ophthalmology, RETFound, one of the most relevant foundation models for retinal images, performs strongly across classification, segmentation, and risk prediction tasks. Despite their effectiveness, foundation models are often computationally prohibitive, hindering their deployment in real-world clinical environments where hardware constraints and latency are critical. To bridge this gap, we introduce CAMEL (Cross-Architecture Masked Embedding Learning), a novel cross-architecture distillation framework that uses an asymmetric masking strategy during embedding learning to effectively transfer knowledge from massive teacher foundation models to compact, lightweight student models. Our experimental evaluation across four datasets shows that CAMEL preserves accuracy while drastically reducing computational complexity, enabling lightweight yet highly accurate models suitable for resource-limited clinical settings.

0.21

Comparative Evaluation of Deep Learning Models for Geographic Atrophy Segmentation in En Face OCT Images

cs.CV ·2026-11-09 ·Utkarsh Doshi, Adarsh Gadari, Sharat Chandra Vupparaboina, Joseph DeCicco, Giulia Gregori +7 more
similarity 0.63
Abstract · 30 pages, 11 figures

Background: Geographic atrophy (GA) is an advanced form of age-related macular degeneration (AMD). It causes irreversible vision loss due to progressive degeneration of the retinal pigment epithelium (RPE) and photoreceptors. Accurate segmentation of GA in en-face image is crucial for early diagnosis, monitoring disease progression, and developing personalized treatment strategies. However, existing deep learning approaches are typically evaluated using single architectures and single-device datasets, limiting insight into relative performance and cross-device robustness. Methods: We trained and systematically compared five deep learning architectures for GA segmentation: Nested U-Net, ResU-Net, nnUnet, Swin-Unet and MedSegDiff model, together with a thresholding based classical baseline. The models were trained on a dataset of en-face OCT images derived from 269 OCT volumes from two different devices, following a three-step preprocessing technique involving normalization and inpainting to enhance the quality of the en-face images. Results: On the fixed held-out validation set comprising OCT scans from both Cirrus (R) (Carl Zeiss Meditec, Inc., USA) and Spectralis (R) (Heidelberg Engineering, Germany) devices, nnUnet achieved the highest mean Dice similarity coefficient (DSC) of 0.8882 +/- 0.0033. The other models yielded the following Dice scores: Nested U-Net (0.7932 +/- 0.0423), ResU-Net (0.8453 +/- 0.0074), Swin-Unet (0.6886 +/- 0.0294), and Diffusion model (0.7959 +/- 0.0242). Conclusions: nnUnet framework, demonstrated most reliable performance for GA segmentation in en-face OCT under limited data conditions. It offers the best balance of accuracy, stability, and efficiency for GA quantification.

0.20

Learning Pathology-Sensitive Representations for Unsupervised Retinal OCT Anomaly Detection

cs.CV cs.LG ·2026-10-23 ·Tania Haghighi, Sina Gholami, Behafarin Emam, Jennifer I Lim, Theodore Leng +3 more
similarity 0.63
Abstract

Deep learning approaches for retinal optical coherence tomography (OCT) predominantly rely on predefined disease categories, limiting their ability to detect rare or previously unseen abnormalities. While visual foundation models provide transferable representations, their effectiveness in identifying pathological deviations from normal retinal anatomy remains insufficiently understood. In this work, we introduce an unsupervised framework for retinal OCT anomaly detection and localization that adapts pretrained visual representations to normal retinal anatomy through anatomy-aware reconstruction and contrastive triplet learning guided by synthetic structural perturbations, without requiring disease-specific annotations. We systematically investigate the influence of pretraining strategies, anatomy-aware representation adaptation, and anomaly scoring mechanisms on the detection and localization of unseen retinal abnormalities. Our findings demonstrate that adapting pretrained representations to normal retinal structure improves anomaly sensitivity, while pixel-space reconstruction errors and feature-space deviations provide complementary signals for identifying pathological changes. These findings underscore the importance of anatomy-aware representation learning and offer insights into developing generalizable retinal anomaly detection frameworks beyond predefined disease categories.

0.30

ORViT-DR: Ordinally-Robust Hybrid ViT for Low-Resolution Diabetic Retinopathy Grading

eess.IV cs.CV ·2026-08-16 ·Soumit Kumar Kundu, Nabil Ashab, Bidhan Biswas, Shahadat Hossain Sohag, Saif Mahmud Parvez +2 more
published similarity 0.62
Abstract · Accepted at ECCT 2026

Diabetic retinopathy (DR) is one of the main causes of impaired vision. A good and reliable automated grading system can make the screening process safer and more accurate. Because DR stages progress gradually, the task of grading disease severity naturally follows an ordinal structure in which neighboring classes share similar visual characteristics. In this study, ORViT-DR, a hybrid deep learning framework, is designed to improve DR grading from low-resolution retinal images. The proposed approach combines convolutional feature extraction with transformer-based global context modeling through a pre-trained ViT-Hybrid backbone, which integrates BiT-ResNetv2 with a Vision Transformer architecture. The approach is tested on the RetinaMNIST subset of the MedMNISTv2 dataset, which contains 28x28 retinal fundus images annotated with five levels of disease severity. To promote stable training and better feature learning, the training strategy applies progressive layer unfreezing, layer-wise learning rate decay, exponential moving average (EMA) parameter updates, and ensemble-based prediction during inference. Experimental results on the official RetinaMNIST test set show that the proposed method achieves 57.00% classification accuracy, along with a quadratic weighted kappa score of 0.5963 and a macro-F1 score of 0.4293. These results suggest that hybrid CNN-Transformer architectures can provide effective representations for ordinal retinal image analysis.

0.19