CS Paper Radar

NucShare: Lightweight Nuclei Instance Segmentation with Foundation-Model Accuracy

Wenyan Li, Xiangyang Jia, Wenlong Zhong, Xu Chen

cs.CV ·submitted 2026-09-28 13:59 UTC · v3
code/data

Abstract

Nuclei instance segmentation is fundamental to quantitative pathology. Yet high-accuracy methods mostly build on large vision transformers (ViTs) or heavy convolutional backbones, whose parameter count and compute cost hinder deployment in clinical and edge settings. We present NucShare, a lightweight model whose shared decoder handles nuclear pixel segmentation, horizontal-vertical distance, and classification through learnable transposed convolutions for upsampling and three lightweight heads, using 37% of independent decoders' parameters with no loss in accuracy. Output-level distillation then transfers knowledge from NucShare-T (UNI2-h) to NucShare-S (ConvNeXt V2-Tiny), reducing 690.5M parameters to 34.7M. On PanNuke they reach mPQ 0.524 and 0.519, above the prior best CFR-SAM-H at 0.511, and NucShare-S surpasses HoVer-Net and Mask R-CNN by 5.6 and 15.0 points; on zero-shot MoNuSeg it attains bPQ 0.668 against CFR-SAM-H's 0.662. Code: https://github.com/L-iMeng-L/Newidea

Comment
5 pages, 3 figures, 4 tables. Submitted to IEEE International Symposium on Biomedical Imaging (ISBI 2027)

Closest papers

Nearest neighbours by meaning across the whole index.

TernScope: Model-Hardware Co-Design for Efficient Ternary Endoscopic Segmentation

eess.IV cs.ARcs.CV ·2026-10-21 ·Zhuoyu Wu, Wenhui Ou, Qiawei Zheng, Xuhong Qiu, Wenqi Fang +1 more
code/data similarity 0.68
Abstract · 5 pages, 4 figures, 3 tables. Code and experimental results: https://github.com/ReaganWu/TernScope

Edge medical segmentation must reconcile small model size, high accuracy, and fast inference. TernScope addresses this tradeoff through model--hardware co-design, learning a compact segmentation network whose low-bit operators also simplify hardware execution. Split-channel large-kernel blocks preserve spatial context with limited computation, while branch fusion removes redundant inference paths. Ternary Progressive Quantization-aware Training (TPQ) then adapts the fused network from deep to shallow layers, through the decoder, and finally to the input and prediction layers. All 25 convolutions use ternary weights and 8-bit activations, enabling packed storage and multiplier-free computation. The resulting model uses 0.2483 M parameters and 0.0949 GMACs while retaining competitive segmentation accuracy on in-domain and external datasets. Under the same 45 nm technology, TernScope reduces compute-array area by 88.46% compared with the original Gemmini, a systolic-array accelerator with 8-bit $\times$ 8-bit multipliers. These results demonstrate a path from accurate lightweight medical segmentation to compact low-bit hardware.

0.39

LightMIS: Ultra-Lightweight Medical Image Segmentation Without a Stage-Wise Decoder

cs.CV ·2026-09-23 ·Andrei Arhire, Mihaela-Elena Breabăn, Radu Timofte
code/data similarity 0.68
Abstract

We present LightMIS, a scalable family of ultra-lightweight convolutional networks for 2D binary medical image segmentation without a learned stage-wise decoder. LightMIS aligns the outputs of a five-level encoder to a common resolution using Scale-Aligned Projection blocks, aggregates them once, and refines the fused representation with an Adaptive Fusion Cascade. The cascade combines Adaptive Kernel Fusion with the proposed Progressive Receptive Fusion module, which uses temporary channel expansion, complementary depthwise receptive fields, and progressive cross-branch information transfer. We evaluate LightMIS-T, LightMIS-S, and LightMIS using five-fold cross-validation under a common nnU-Net v2.3.1 protocol on DRIVE, Kvasir-SEG, DSB18, BUSI, ISIC-2017, and ISIC-2018. Full LightMIS contains 0.131 M parameters and requires 0.575 GFLOPs for a $3\times256\times256$ input, achieving modality-macro Dice and IoU scores of 86.71% and 78.99%, respectively. Mobile U-ViT obtains 86.75% Dice and 79.07% IoU, so the observed differences are 0.04 and 0.08 percentage points. Relative to Mobile U-ViT, nnWNet, and nnU-Net, LightMIS reduces parameter count by 90.58$-$99.61% and GFLOPs by 82.54$-$96.14%. On an Arm Mali-G52 MC2 GPU, all LightMIS variants achieve full GPU delegation, with median delegated latency ranging from 53.31 ms for LightMIS-T to 138.31 ms for LightMIS. These results demonstrate a favorable accuracy-complexity trade-off and on-device execution feasibility for the evaluated tasks. The code is publicly available at https://github.com/AndreiiArhire/LightMIS.

0.32

nnFoundation: 3D Foundation Models for Radiology

cs.CV eess.IV ·2026-09-22 ·Constantin Ulrich Harsy, Tassilo Wald, Karol Gotkowski, Yannick Kirchhoff, Marcel Knopp +78 more
highly cited similarity 0.66
Abstract

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

0.42

DINO-Nucleus: Multi-Level Self-Supervised Features for Nucleus Instance Segmentation

cs.CV ·2026-11-06 ·Mohammad Sarhangzadeh, Elyar Esmaeilzadeh, Doruk Oner
similarity 0.65
Abstract · 10 pages, 2 figures

Nucleus instance segmentation and counting are essential for quantitative microscopy, enabling reliable analysis of cell populations, tissue organization, and disease-related changes. However, accurately separating touching nuclei remains difficult, and many existing approaches rely on complex models or sensitive post-processing procedures. We present DINO-Nucleus, a parameter-efficient framework that leverages multi-level self-supervised DINOv2 representations for nucleus instance segmentation and counting. The model jointly predicts nucleus regions, pixel-wise instance flows, and explicit nucleus centers, while a consistency objective encourages the predicted flows to converge toward their corresponding centers. Multi-level transformer features provide complementary spatial and semantic information, and the pretrained backbone is adapted using lightweight LoRA modules to reduce fine-tuning cost. Experimental results show that DINO-Nucleus achieves strong segmentation and counting performance with parameter-efficient backbone adaptation. These findings demonstrate that parameter-efficient adaptation of multi-level self-supervised features can provide an effective solution for nucleus instance segmentation in microscopy images.

0.25

GDBA-Net: A Gated Dual-Branch Adaptation of SAM2 for Robust Cross-Domain Nuclei Segmentation

cs.CV ·2026-10-14 ·Biplab Poudel, Betserai Albert Magarire, Anish Kumar Shah, Jiacheng Xie, Dong Xu
code/data similarity 0.64
Abstract

Accurate nuclei segmentation underpins quantitative computational pathology, yet remains challenging due to morphological variability, weak boundaries, nuclear crowding, and pronounced domain shifts arising from differences in tissue preparation, staining, and acquisition. While deep learning and recent foundation models have improved segmentation performance under matched distributions with the original training data, their generalization across heterogeneous histopathology domains remains limited. We introduce GDBA-Net, a parameter-efficient nuclei segmentation framework built around the proposed Gated Dual-Branch Adapter (GDBA). GDBA-Net adapts a frozen SAM2 encoder by integrating pretrained semantic representations with explicit frequency-derived structural priors. The complementary representations are independently transformed through Grid MLP branches and dynamically integrated using sample-adaptive channel-wise gating, selectively emphasizing structural cues relevant to nuclear delineation. Despite using only 4.3 million trainable parameters, GDBA-Net achieves state-of-the-art in-dataset performance and consistently superior cross-dataset generalization across six diverse nuclei segmentation benchmarks under fully supervised, cross-dataset, and five-shot adaptation protocols, outperforming competing CNN-, transformer-, and foundation model based methods. Comprehensive ablations confirm that these gains arise from the coordinated design of semantic-frequency complementarity and adaptive gating rather than increased model capacity. By uniting transferable semantic representations with explicit structural priors, GDBA-Net provides a robust, annotation-efficient solution to domain variability in nuclei segmentation. https://github.com/biplabpoudel25/GDBA_Net

0.28

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.64
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.13

NanoNet: Ultra-Lightweight Network for MRI Brain Tumor Classification toward Edge AI

cs.CV ·2026-11-08 ·Tran Nguyen-Le, Huu-Thuan Huynh, Minh-Triet Tran, Trung-Nghia Le
benchmark similarity 0.63
Abstract

Automated brain tumor classification from magnetic resonance imaging (MRI) can support accessible medical image analysis, but conventional deep learning models often exceed the resource budgets of highly constrained edge-AI platforms. We present NanoNet, an ultra-lightweight convolutional neural network designed for resourceconstrained MRI classification and motivated by future edge-AI applications. Inspired by MobileNetV2, NanoNet substantially reduces network depth, channel capacity, expansion ratios, and final feature dimensionality, resulting in only five inverted residual blocks and 8,132 parameters. We further investigate dependency-aware structured pruning, knowledge distillation, and INT8 quantization-aware training for additional compression. Experiments on the BRISC 2025 benchmark show that NanoNet achieves 92.80% accuracy and 92.97% macro F1 with 8,132 parameters and 10.498 MFLOPs. Across three compression seeds, it exceeds the mean accuracy of 70%-pruned MobileNetV2 by 5.20 percentage points while using 60.2% fewer parameters and 9.8% less computation. Converted INT8 NanoNet achieves 89.70% accuracy and 90.22% macro F1 across three QAT seeds. Earlier TensorFlow Lite measurements indicate 27.7 KB of baseline model storage, motivating future edge-AI deployment.

0.12

TRIUNE-Net: Harmonizing Scale, Shape, and Efficiency in Pancreatic Tumor Segmentation

cs.CV ·2026-09-08 ·Amir Hossein Saleknia, Alireza Kheyrkhah, Sanaz Karimijafarbigloo, Reza Azad, Sina Houshmand +3 more
code/data similarity 0.63
Abstract

Pancreatic tumor segmentation in 3D CT volumes is challenged by extreme scale variability across both the pancreas and tumor, and highly irregular tumor morphology. While recent advances have pushed segmentation performance, existing methods do not explicitly address these challenges and come at the cost of excessive computational complexity, limiting their practicality in resource-constrained clinical environments. We propose TRIUNE-Net, a lightweight unified architecture that harmonizes scale, shape, and efficiency through three synergistic innovations. A multi-scale context aggregation module with stage-adaptive dilated convolutions enables the model to reason across the broad range of anatomical scales present in both organs. A serial linear-deformable attention mechanism combines large effective receptive fields with shapeadaptive deformable convolutions to capture irregular, non-convex tumor morphologies. Finally, an information-preserving downsampling module replaces conventional max pooling entirely, retaining all spatial information while adding negligible parameters, preventing small tumors from being discarded before they can be recognized. On both the MSD Pancreas and NVD Pancreas datasets, TRIUNE-Net achieves state-of-theart results with only 5.86 M parameters and no external pre-training, outperforming all baselines across all key tumor metrics. Specifically, it surpasses the next-best model by 0.45% in tumor Dice, 6.0 points in F1 score, 6.6 points in sensitivity, and 3.4 points in precision, simultaneously reflecting its ability to suppress both missed tumors and false alarms in clinically realistic conditions. Our code is available at: https://github.com/abdora-ai/TRIUNE-Net

0.30