CS Paper Radar

Institution-Specific LLM Prompting Recovers PHI That De-identification Systems and Their Gold Standards Both Miss

Daniel Palacios, Matthew Brady Neeley, Angel Adetomike Otto, Shalini Dhamodharan, John P. Woodhouse, Chi-fan Lin, Mark Zobeck, Zhandong Liu, Hyun-Hwan Jeong

cs.CL cs.AI ·submitted 2026-08-17 18:56 UTC · v1
hot direction

Abstract

Secondary use of electronic health records requires de-identification, yet existing systems miss \emph{institutionally situated} protected health information (PHI) such as hospital abbreviations, building names, and internal codes whose status is locally determined. We ask whether large language models (LLMs) with in-context learning (ICL) can close this gap and control the precision--recall trade-off. On 100 annotated pediatric oncology notes (5,322 PHI spans) from Texas Children's Hospital, we benchmarked eight LLMs against two purpose-built systems (Stanford TiDE, OpenMed PII) and two pattern-based baselines. Each LLM ran under three prompts of increasing specificity: (1) a HIPAA-aligned baseline, (2) baseline plus the institutional PHI categories it missed, and (3) prompt 2 plus instructions against over-redacting clinical content. We then compared 14~multi-agent and ensemble configurations against the best single prompt, with recall the primary safety metric. LLMs outperformed the purpose-built systems (best F1=0.918$\pm$0.001 vs.\ TiDE 0.779), with advantages concentrated in contextual categories. Naming the missed categories recovered 79\% (48/61) of them, and discouraging over-redaction restored precision. No agentic architecture beat calibrated single-pass prompting (F1 0.906--0.907), but LLM outputs surfaced 414~candidate annotation gaps; re-annotation confirmed 227~PHI spans, against which the final prompt reached recall=0.981 (F1=0.907$\pm$0.002). Well-calibrated ICL resolves both the institutional PHI gap and the precision--recall trade-off in one LLM call per note. LLMs cost more to run than traditional methods, but that cost buys a way to audit the reference standard. LLMs are a legitimate, adaptable alternative to purpose-built de-identification systems; institution-specific prompt development should be the primary adaptation strategy.

Closest papers

Nearest neighbours by meaning across the whole index.

From Small to Large: Assessing Medical Reasoning, Benchmark Contamination, and Model Size in Language Models

cs.AI cs.CL ·2026-10-30 ·Navapat Nananukul, Mayank Kejriwal
benchmark similarity 0.67
Abstract

Large language models (LLMs) now answer medical exam questions at or above expert level, but it is unclear whether such scores reflect clinical competence, or are instead affected by the format of the questions being asked (e.g., multiple-choice versus open-ended), prior exposure to the benchmarks, and the difficulty of the questions. These benchmarks are also public and widely used online, which may be resulting in LLM memorization. Models may perform better on questions that they have seen before. It is also not evident whether smaller models, which are more locally deployable in HIPAA-compliant hospital settings, have achieved human performance. In this study, we evaluate fourteen current models from six leading providers, one smaller and one larger model from each provider with two additional open-weight models, on 3,076 questions from four medical benchmarks (MedQA-USMLE, MedMCQA, PubMedQA, and MedBullets) under standard multiple choice, the same questions with the answer choices withheld, and reconstruction of a hidden question from its choices alone. In the standard multiple-choice setting, the strongest models exceed the human-expert baseline on MedQA-USMLE and PubMedQA, but the smaller models trail their larger models by 8.7 percentage points and only two of the six pass the human-expert bar on the licensing examination. Withholding the answer choices, however, makes every model struggle: mean accuracy falls from 82.3% to 50.9%, and the two largest drops belong to the medically specialised models. On memorization, the strongest models reconstruct one question in four from the answer choices alone, yet accuracy holds on the questions they cannot reconstruct. We further weigh accuracy against inference cost and test whether ensembling several models improves medical question answering.

0.15

Counterfactual Auditing of Bias in Open-Source Large Language Models for Clinical Triage

cs.AI cs.CLcs.LG ·2026-10-01 ·Manar Aljohani, Brandon Ho, Kenneth McKinley, Dennis Ren, Xuan Wang
code/data similarity 0.66
Abstract

Emergency department (ED) triage is a high-stakes prioritization task in which demographic, socioeconomic, and system-context information may improperly influence acuity assignment. Although open-source large language models (LLMs) are increasingly considered for local and privacy-preserving clinical decision support, it remains unclear how counterfactual bias varies across model families, sizes, medical-domain models, and domain-adapted models. We present a comparative counterfactual audit of ten open-source LLMs for pediatric Emergency Severity Index (ESI) prediction. Starting from real and handbook-style clinical vignettes, we construct paired counterfactual variants that change only one injected demographic, socioeconomic, healthcare-access, behavioral, social, or system-context variable while holding the clinical presentation fixed. Models include Qwen2.5-7B, Qwen2.5-14B-Instruct, a QLoRA fine-tuned Qwen2.5-7B, MedGemma variants, MedLLaMA2-7B, GPT-OSS-20B, and GPT-OSS-120B. We measure any counterfactual shift, undertriage, overtriage, shifts greater than one ESI level, mean shift, and mean absolute shift. Counterfactual sensitivity varied substantially and did not consistently decrease with larger model size or medical-domain pretraining. The fine-tuned Qwen2.5-7B showed the lowest overall sensitivity, with a 5.27% any-shift rate and mean absolute shift of 0.0534, versus 16.02% and 0.1706 for the base model. Several larger or medical-domain models showed more significant shifts. Stratified and correlation analyses further revealed clinically important directionality and shared failure patterns hidden by aggregate rates. These findings support counterfactual auditing as a lightweight, clinically interpretable framework for comparing fairness risks in open-source LLMs before clinical deployment.

0.48

A local language model layered with rule-based and neural detectors for clinical text de-identification: an open-source toolkit and evaluation

cs.CL cs.CYcs.SE ·2026-11-09 ·Valentin Burkin
code/data similarity 0.65
Abstract · 17 pages, 2 figures, 4 tables; supplementary material as ancillary file. Code: https://github.com/valburkin/DeidSharp

Objectives: To measure whether a locally hosted large language model (LLM), stacked with deterministic and clinical named-entity recognition (NER) detectors, finds more protected health information (PHI) than open tools, and at what precision. Materials and Methods: DeidSharp, an open-source .NET toolkit, combines the findings of pluggable detectors (patterns, a clinical NER model, a local 26B mixture-of-experts LLM) and fails closed on any detector error. Configurations fixed on tuning halves were compared, under a prespecified protocol, with deid, Philter, the Stanford/Penn de-identifier, OpenAI Privacy Filter and GLiNER on reporting halves of PhysioNet's nursing notes (889 spans) and semi-synthetic MIMIC-IV-Note discharge summaries (29,023 spans), and on synthetic ASQ-PHI queries, with paired patient-level bootstrap intervals. Results: In the nursing notes, against Stanford/Penn, the recall-first stack found 98.9% of PHI (+2.8, 95% CI 1.4 to 4.4) at 9.3 points lower precision; the precision-first stack, without NER, found 96.5%, matching Stanford/Penn, at 19.6 points higher precision (83.2%). In the discharge summaries, both stacks led Stanford/Penn by more than 20 points (recall-first 95.3%, +21.5, 20.5 to 22.4), almost entirely on generated untyped names; on typed labels all three exceeded 99%. All four prespecified comparisons held. No configuration beat deid significantly on its home corpus; Philter found more discharge-summary spans than the recall-first stack at 23 points lower precision. Discussion: The LLM was the main detector and NER added place names; asked to verify its own findings, the LLM discarded a quarter of true PHI. Conclusion: A local LLM layered with deterministic detectors offers recall-first and precision-first operating points without sending text off-site.

0.36

Clinician use of language models diverges from how the models are evaluated

cs.CL ·2026-10-08 ·Krithik Vishwanath, Haitong Lin, Anton Alyakin, Jin Vivian Lee, D. Brock Hewitt +17 more
benchmark similarity 0.65
Abstract

Large language model (LLM) assistants are being deployed to clinicians across health systems, and judgments about their readiness rest largely on benchmark scores, most of them derived from examination questions or curated cases. A benchmark predicts performance in deployment only to the extent that its items resemble real use, yet whether benchmarks reflect the work these systems receive has rarely been measured. Here we analyze 127,833 queries sent by 6,342 physicians, advanced practice providers and nurses in 35 specialties to an institutional assistant during an eight-month roll-out. We characterize each query with RCQ-Map, a clinician-validated framework grounded in taxonomies of clinical questions and of LLM evaluation, which records its task, intent, answerability, missing information and potential harm. Documentation and administration (36.2%) and knowledge retrieval (28.9%) made up nearly two-thirds of use, and diagnosis 3.7%; more than a third of queries could not be answered well as posed. Applying RCQ-Map to 58 public benchmarks drawn from major evaluation suites and frontier model reports, which we assemble into the Clinical AI Benchmark Atlas, showed that the median benchmark contained no documentation requests and shared 31% of the task mix of real use, less than an even spread across task categories would. Benchmarks in suites designed to resemble clinical practice were individually no closer to real use than those used in frontier model reports. Benchmark scores therefore say little about how clinical AI performs on most of the work it is actually given, and evaluation should be matched to real clinical use.

0.08

Clinical Concept Centers in LLMs

cs.CL cs.LG ·2026-10-02 ·Aishik Nagar, Abhishek Vaidyanathan, Arun-Kumar Kaliya-Perumal, Elijah Tzen Hsuen Boey, Stefan Winkler
similarity 0.65
Abstract

Large language models are increasingly used in clinical settings. However, research into the reliability and performance of these models has focused almost entirely on the language substrate, scoring what the model says. Mechanistic interpretability has found that the latent space carries a higher fidelity of representation than the text: internal representations not only encode substantially more than the output verbalizes, but the stated reasoning also systematically omits features that causally drive the answer. An evaluation of model behavior in terms of mechanistic interpretability has not been explored in clinical decision support. In this work, we extend behavioral evaluation into the latent space and ask whether clinical concepts exist as locatable, causally used representations inside open-weight LLMs. We find dedicated clinical concept centers in the latent space of all eleven open models we test. These concept centers are interpretable, firing only on their aligned clinical narratives, and meaningfully and causally drive model behavior in both constrained and open-ended settings. They are not just analytical representations, but circuits that can be utilized in clinical practice, and we explore their use from the perspective of both evaluation and performance. From the evaluation standpoint, models stay internally coherent and keep using the relevant concept centers even under adversarial role-based priming, while aligned priming improves downstream clinical performance. From a performance perspective, we simulate realistic deployment settings and find that steering models along these centers leads to meaningful downstream improvements. Finally, we conduct a blinded clinician validation and find the activation and usage of these concept centers predicts clinicians preferences.

0.27

MedDeID enables locally governed clinical-text de-identification from real or synthetic training data

cs.CL cs.LG ·2026-09-09 ·Stig Hellemans, Tom Stroobants, Elyne Scheurwegs, Pieter Meysman, Philippe G. Jorens +1 more
benchmark similarity 0.65
Abstract · 64 pages total: 32-page main manuscript with 4 figures, followed by 32-page Supplementary Information

Clinical notes contain personally identifiable information (PII), restricting reuse for research and medical AI, especially when data cannot leave an institution. We developed MedDeID, an on-premises framework combining in-house annotation and synthetic-note generation with model training, inference, pseudonymisation and evaluation. On an independently annotated, adjudicated 300-note Dutch hospital benchmark, a hospital-trained compact transformer detected 98.9% of identifying text while redacting 0.24% of text outside annotated identifiers; a synthetic-only counterpart detected 96.1%. On 100 primary-care notes, the synthetic-trained model achieved higher recall than the hospital-trained model (90.3% versus 87.0%) and greater robustness to identifier-format perturbations. An English instantiation trained without real text detected 99.7% and 98.9% of annotated identifier characters on two external synthetic benchmarks. These results demonstrate transfer of the workflow to another language, but not clinical English performance. MedDeID provides a route to locally governed de-identification using real or synthetic training data.

0.52

Locally Deployable Small Language Models for Emergency Department Decision Support: A Systematic Benchmark of Fine-Tuning Strategies

cs.CL cs.AI ·2026-08-10 ·Qingfeng Zhang, Yuanxiong Guo, Yanmin Gong
publishedbenchmarkcode/data similarity 0.64
Abstract · Accepted to AMIA 2026 Annual Symposium

Deploying large language models (LLMs) for decision support in emergency departments (EDs) faces two major challenges: privacy risks of transmitting patient data to closed-source commercial LLMs and the lack of systematic evaluation of fine-tuning strategies for locally deployable open-source small language models (SLMs). We benchmarked eight open-source SLMs using zero-shot prompting, prefix tuning, Low-Rank Adaptation (LoRA), and full fine-tuning on three ED tasks: triage level prediction, specialist referral recommendation, and diagnosis prediction. Using 2,083 MIMIC-IV-ED cases and Claude Haiku 4.5 and Claude Sonnet 4.5 as baselines, we found that LoRA fine-tuned open-source SLMs outperform commercial baselines on triage level prediction and specialist referral recommendation, while diagnosis prediction remains challenging for open-source SLMs. Confusion matrix analysis further shows that fine-tuned open-source SLMs can detect highest-severity patients missed by the commercial baselines. These results demonstrate that locally deployable SLMs can achieve clinically competitive performance for ED decision support.

0.35

ALLMTS: Automated LLM-based Medical Triage System

cs.AI ·2026-10-23 ·Michał Remigiusz Janiszewski, Artur Stopa, Łukasz Lenkiewicz, Wojciech Achtelik, Bartosz Gonczarek
publishedbenchmark similarity 0.64
Abstract · Accepted at the GenAI4Health Workshop at NeurIPS 2026

Telephone triage is a safety critical task: from a brief intake note, a nurse must decide whether a caller needs an ambulance, an emergency department, an appointment, or self care at home. Queried directly, large language models (LLMs) are unreliable: they over-escalate routine cases and cannot justify their recommendations against an auditable clinical standard. We present the Automated LLM-based Medical Triage System (ALLMTS), which grounds every disposition in the same commercially maintained telehealth guidelines nurses use. Rather than asking an LLM to triage, ALLMTS makes it execute the guideline: it selects the appropriate guideline and evaluates its triage assessment questions. The disposition follows deterministically from the first positive answer, using the same traversal rule a nurse follows. We evaluate ALLMTS on 566 synthetic, expert-validated scenarios spanning 14 dispositions and designed to test specific guideline questions. ALLMTS achieves 0.95 accuracy, compared with 0.47 for a raw-LLM baseline. On a curated 50-scenario subset released as an open benchmark, ALLMTS reaches 0.98 accuracy, on par with the 0.944 correct disposition rate that a five nurse expert panel recorded on those same scenarios. Critically, on that subset the baselines have over-triage rates of up to 0.50 (0.44 on the full dataset), whereas ALLMTS reduces the over-triage rate to at most 0.02 while maintaining low under-triage. These results support coupling LLM language understanding with executable clinical guidelines for triage from intake notes.

0.27