CS Paper Radar

Clinical Concept Centers in LLMs

Aishik Nagar, Abhishek Vaidyanathan, Arun-Kumar Kaliya-Perumal, Elijah Tzen Hsuen Boey, Stefan Winkler

cs.CL cs.LG ·submitted 2026-10-02 05:22 UTC · v2

Abstract

Large language models are increasingly used in clinical settings. However, research into the reliability and performance of these models has focused almost entirely on the language substrate, scoring what the model says. Mechanistic interpretability has found that the latent space carries a higher fidelity of representation than the text: internal representations not only encode substantially more than the output verbalizes, but the stated reasoning also systematically omits features that causally drive the answer. An evaluation of model behavior in terms of mechanistic interpretability has not been explored in clinical decision support. In this work, we extend behavioral evaluation into the latent space and ask whether clinical concepts exist as locatable, causally used representations inside open-weight LLMs. We find dedicated clinical concept centers in the latent space of all eleven open models we test. These concept centers are interpretable, firing only on their aligned clinical narratives, and meaningfully and causally drive model behavior in both constrained and open-ended settings. They are not just analytical representations, but circuits that can be utilized in clinical practice, and we explore their use from the perspective of both evaluation and performance. From the evaluation standpoint, models stay internally coherent and keep using the relevant concept centers even under adversarial role-based priming, while aligned priming improves downstream clinical performance. From a performance perspective, we simulate realistic deployment settings and find that steering models along these centers leads to meaningful downstream improvements. Finally, we conduct a blinded clinician validation and find the activation and usage of these concept centers predicts clinicians preferences.

Closest papers

Nearest neighbours by meaning across the whole index.

Large language models are vulnerable to incidental information in clinical documentation and reasoning

cs.CL ·2026-10-06 ·Krithik Vishwanath, Brandon Ye, Anton Alyakin, John E. Markert, Aaron Hsieh +2 more
similarity 0.67
Abstract

Large language models (LLMs) are increasingly relied upon to support ambient documentation and clinical reasoning. Here we examine the impact of a failure mode shared between these two applications by assessing their sensitivity to information incidental to the patient encounter. In 576 patient-clinician dialogues, we found that frontier models inserted small-talk exchanges into 35% of notes, while mean quality scores changed by at most 0.20 points on five-point scales. In 3.7% of frontier notes, models misattributed the asides or used them clinically. In 57 mock recorded consultations, background speech from a separate patient encounter at -10 dB leaked into 48.2% of transcripts, with contamination detected in 5.3% of downstream notes generated by four open-weight models. We propose a dual encoding hypothesis of clinical reasoning and distraction in LLMs, with preliminary evidence that LLM components associated with disruption by incidental information also support clinical reasoning. These findings support evaluating resistance to incidental information before clinical use, with safeguards that prevent contamination while preserving clinical reasoning.

0.23

RAG-Enhanced LLMs for Interactive Explainability in Clinical Decision Support Systems

cs.AI cs.HCcs.LG ·2026-11-06 ·Lorenzo Mannocci, Francesca Naretto, Lucia Passaro, Anna Monreale
published similarity 0.66
Abstract · Published in HC_AIxIA_HYDRA 2025, Communications in Computer and Information Science, vol. 2830, pp. 50-63, Springer, 2026. Please cite the …

Artificial Intelligence (AI) is increasingly embedded in high-risks decision-making systems across domains such as healthcare, finance, and the judicial system. As reliance on predictive models grows, so does the demand for Explainable AI (XAI) to ensure transparency, trust, and interpretability. However, existing XAI approaches often fail to present explanations in a format accessible to domain experts, limiting their practical utility. Large Language Models (LLMs) have recently emerged as a bridge between complex models and end-users, offering natural language explanations. Yet, their use introduces new risks, including hallucinated outputs and lack of source traceability. To address these challenges, we propose a Clinical Decision Support System (CDSS) that not only combines standard predictive models with XAI techniques but also incorporates a Retrieval-Augmented Generation module as an interactive enhancer. This module grounds explanations in verified medical knowledge, reformulates technical outputs into a human-like format, and enables users-such as clinicians-to actively query the system. By fostering an interactive, human-in-the-loop environment, our approach empowers domain experts to explore model decisions, contextualize explanations, and build trust in AI-assisted diagnostics. The study concludes with preliminary experiments validating the proposed methodology.

0.20

Domain-Specific Jargon in Large Language Models: A Comparative Analysis between General-Purpose and Specialist Models

cs.CL cs.AIcs.LG ·2026-09-11 ·Darin Keng, Zhewei Sun
top venuebenchmark similarity 0.65
Abstract · Accepted to EMNLP 2026 main conference

Large Language Models (LLMs) have shown remarkable proficiency on general-purpose tasks, yet their performance often degrades in highly-specialized technical domains. Moreover, little is known about how parametric knowledge of domain-specific terms is encoded within these models. We address this gap by contributing two novel medical jargon evaluation benchmarks and evaluate a general-purpose Llama-3.1 model against a variant fine-tuned on medical-domain data. Surprisingly, the general-purpose model outperforms the medically fine-tuned model on both tasks. Using mechanistic interpretability tools, we find systematic patterns of miscalibration for the medically fine-tuned model. Instead of reorganizing parametric knowledge, the fine-tuned model places greater emphasis on a small subset of model components associated with jargon-favoring predictions. We find that applying component reweighting strategies against the benchmark tasks successfully suppresses these components and closes the gap with the general-purpose baseline. We also observe that some jargon-sensitive components transfer knowledge to the same tasks involving materials science jargon, suggesting they encode a partially domain-agnostic notion of specialized terminology. Our results provide a case study in which a medically fine-tuned checkpoint does not improve jargon comprehension over its general-purpose counterpart, highlighting that domain adaptation should not be assumed to yield better performance on specialized terminology.

0.40

Institution-Specific LLM Prompting Recovers PHI That De-identification Systems and Their Gold Standards Both Miss

cs.CL cs.AI ·2026-08-17 ·Daniel Palacios, Matthew Brady Neeley, Angel Adetomike Otto, Shalini Dhamodharan, John P. Woodhouse +4 more
hot direction similarity 0.65
Abstract

Secondary use of electronic health records requires de-identification, yet existing systems miss \emph{institutionally situated} protected health information (PHI) such as hospital abbreviations, building names, and internal codes whose status is locally determined. We ask whether large language models (LLMs) with in-context learning (ICL) can close this gap and control the precision--recall trade-off. On 100 annotated pediatric oncology notes (5,322 PHI spans) from Texas Children's Hospital, we benchmarked eight LLMs against two purpose-built systems (Stanford TiDE, OpenMed PII) and two pattern-based baselines. Each LLM ran under three prompts of increasing specificity: (1) a HIPAA-aligned baseline, (2) baseline plus the institutional PHI categories it missed, and (3) prompt 2 plus instructions against over-redacting clinical content. We then compared 14~multi-agent and ensemble configurations against the best single prompt, with recall the primary safety metric. LLMs outperformed the purpose-built systems (best F1=0.918$\pm$0.001 vs.\ TiDE 0.779), with advantages concentrated in contextual categories. Naming the missed categories recovered 79\% (48/61) of them, and discouraging over-redaction restored precision. No agentic architecture beat calibrated single-pass prompting (F1 0.906--0.907), but LLM outputs surfaced 414~candidate annotation gaps; re-annotation confirmed 227~PHI spans, against which the final prompt reached recall=0.981 (F1=0.907$\pm$0.002). Well-calibrated ICL resolves both the institutional PHI gap and the precision--recall trade-off in one LLM call per note. LLMs cost more to run than traditional methods, but that cost buys a way to audit the reference standard. LLMs are a legitimate, adaptable alternative to purpose-built de-identification systems; institution-specific prompt development should be the primary adaptation strategy.

0.53

A Concept-Based Interpretable Framework for Clinical Text-based Prediction via Token-Concept Attention without Concept Supervision

cs.CL cs.AI ·2026-11-10 ·Jifan Gao, Junjie Hu, John Caskey, Madeline Oguss, Simona Cristea +4 more
code/data similarity 0.65
Abstract

Objective: Concept-based interpretation has emerged as a promising approach for explaining blackbox models using human-understandable, high-level concepts. However, most existing methods require annotated concept labels to train the model to identify concepts in the input, and obtaining such annotations in clinical text is often expensive. This study aims to enable concept-based interpretation for language models without concept supervision on clinical prediction tasks. Methods: We propose a novel framework that enables concept-based interpretation without concept supervision through a tailored cross-attention bottleneck. Clinical text and the text descriptions of medical concepts are first tokenized and embedded by a pretrained language model. A cross-attention module then estimates the presence of each concept for each text token, producing concept relevance scores that capture how concepts are involved throughout the note. These scores are pooled and used in a linear prediction layer to model clinical outcomes in an interpretable manner. Results: The performance of the proposed framework was compared against blackbox models across two tasks: chest trauma severity stratification using a private dataset and an in-hospital mortality prediction task using the publicly available MIMIC-III dataset. The proposed framework achieved AUROC values within 0.02 of the corresponding blackbox models. The framework also enabled cohort- and patient-level interpretation, capturing the overall concept importance across the cohort and patient-specific concept contributions. Conclusion: Our proposed framework realizes concept-based interpretation without requiring ground-truth concept presence labels. It improves the transparency of clinical text predictions while maintaining strong performance in clinical prediction tasks.

0.30

Making every stage of medical device document assessment with large language models deterministic

cs.CL cs.IR ·2026-10-15 ·Ryosuke Suzuki
similarity 0.65
Abstract · 30 pages, 3 figures, 3 tables; supplementary tables S1-S15 and two supplementary notes included

To show that a medical device complies with regulation, experts judge whether documents and records meet each requirement and record the judgment for others to verify. For each assessment item that experts define, large language models could prepare a preliminary assessment: a label such as Satisfied or Not satisfied, a reason and quoted evidence. We sent fourteen commercial deployments of such models (seven models from three providers, through six routes) the same request repeatedly, with the deterministic sampling settings each accepted; every deployment returned differing assessments for at least one request, and in twelve the label changed. Reducing reasoning where the interface allows it did not reduce the variation, and prompts of retrieved passages removed it only for the smallest models. The same open-weight model was reproducible or not depending only on how it was served. A pipeline we built to be deterministic at every stage -- text extraction and optical character recognition (OCR), chunking, embedding, indexing, retrieval and inference -- returned byte-identical output at each stage across reruns, interruptions, edits, machines of one graphics processing unit (GPU) model and days, for blood glucose meter and infusion pump documents. OCR, embedding and approximate retrieval varied when their own serving was not made invariant, and outputs changed with the GPU model and with the inference engine's scheduling settings, which therefore belong in the recorded configuration. End-to-end determinism is achievable and gives a testable basis for audit and change control.

0.24

Clinician use of language models diverges from how the models are evaluated

cs.CL ·2026-10-08 ·Krithik Vishwanath, Haitong Lin, Anton Alyakin, Jin Vivian Lee, D. Brock Hewitt +17 more
benchmark similarity 0.65
Abstract

Large language model (LLM) assistants are being deployed to clinicians across health systems, and judgments about their readiness rest largely on benchmark scores, most of them derived from examination questions or curated cases. A benchmark predicts performance in deployment only to the extent that its items resemble real use, yet whether benchmarks reflect the work these systems receive has rarely been measured. Here we analyze 127,833 queries sent by 6,342 physicians, advanced practice providers and nurses in 35 specialties to an institutional assistant during an eight-month roll-out. We characterize each query with RCQ-Map, a clinician-validated framework grounded in taxonomies of clinical questions and of LLM evaluation, which records its task, intent, answerability, missing information and potential harm. Documentation and administration (36.2%) and knowledge retrieval (28.9%) made up nearly two-thirds of use, and diagnosis 3.7%; more than a third of queries could not be answered well as posed. Applying RCQ-Map to 58 public benchmarks drawn from major evaluation suites and frontier model reports, which we assemble into the Clinical AI Benchmark Atlas, showed that the median benchmark contained no documentation requests and shared 31% of the task mix of real use, less than an even spread across task categories would. Benchmarks in suites designed to resemble clinical practice were individually no closer to real use than those used in frontier model reports. Benchmark scores therefore say little about how clinical AI performs on most of the work it is actually given, and evaluation should be matched to real clinical use.

0.08

Verification Turns Capability Gaps into Routing Decisions: Small Language Models for Clinical Documentation

cs.AI ·2026-10-13 ·Nina Fatehi, Meysam Ghaffari, Animesh Agarwal, Anushka Swarup, Carlos Morato
similarity 0.64
Abstract

Clinical note generation from doctor--patient dialogue is high-volume and hallucination-intolerant: a fabricated laboratory value can create patient-safety risk, not a quality regression. We ask whether an agentic \emph{verification} architecture, rather than generator scale, can make a small language model viable here. Holding a four-evaluator verification stack and refinement policy fixed and swapping only the generator between a 4B-parameter model with a QLoRA adapter and a frontier baseline, the small model reaches $0.984$ claim-level factual entailment against $0.992$ and comes within $3.3$ points on completeness, generating entirely on-device. Its deficit is confined to \emph{inter-section structural fidelity}---arrangement rather than clinical comprehension, and the axis on which it also falls furthest below the corpus's reference notes. Because that deficit is an explicit verifier decision rather than a silent quality difference, it becomes a routing policy: run the small model by default, escalate what the verifier rejects. Measured end to end, that it achieved a similiar verified-rate acceptance to the frontier-only acceptance in this test set ($99.6\%$ vs.\ $98.4\%$ over $250$ encounters) while routing $62$, documenting three quarters without a frontier \emph{generation} call. Ablating the loop separates architecture from scale: unrefined, the small model is accepted on $26.8\%$ of encounters and the frontier model on $74.8\%$, so verification does the most work where the generator is weakest. We also contribute section-scoped refinement, which preserves unflagged sections by construction rather than instruction, and find the baseline is not uniformly stronger---its provider refused two trauma-related transcripts the on-device model handled and certified, one facet of a provider dependency a served adapter does not carry.

0.27