CS Paper Radar

Large language models are vulnerable to incidental information in clinical documentation and reasoning

Krithik Vishwanath, Brandon Ye, Anton Alyakin, John E. Markert, Aaron Hsieh, Michał Mańkowski, Eric K. Oermann

cs.CL ·submitted 2026-10-06 15:55 UTC · v2

Abstract

Large language models (LLMs) are increasingly relied upon to support ambient documentation and clinical reasoning. Here we examine the impact of a failure mode shared between these two applications by assessing their sensitivity to information incidental to the patient encounter. In 576 patient-clinician dialogues, we found that frontier models inserted small-talk exchanges into 35% of notes, while mean quality scores changed by at most 0.20 points on five-point scales. In 3.7% of frontier notes, models misattributed the asides or used them clinically. In 57 mock recorded consultations, background speech from a separate patient encounter at -10 dB leaked into 48.2% of transcripts, with contamination detected in 5.3% of downstream notes generated by four open-weight models. We propose a dual encoding hypothesis of clinical reasoning and distraction in LLMs, with preliminary evidence that LLM components associated with disruption by incidental information also support clinical reasoning. These findings support evaluating resistance to incidental information before clinical use, with safeguards that prevent contamination while preserving clinical reasoning.

Closest papers

Nearest neighbours by meaning across the whole index.

AI in the Clinical Documentation Loop: Effects of LLM-Induced Note Bloat and Diagnostic Overcall on Downstream LLMs

cs.CL cs.AI ·2026-11-07 ·Jinghui Liu, Anthony Nguyen, Taylan Gurgenci
similarity 0.71
Abstract · ML4H 2026 - Findings

Large language models (LLMs) are increasingly used to process medical records for healthcare tasks such as clinical documentation. Because these tools also generate documentation, the relationship is now bidirectional: models both read from and write to the record. Understanding how LLMs behave when reading records that already contain LLM-authored content is therefore critical for their safe deployment. In this study, we examine how LLM-authored content in the medical record affects downstream LLMs that read the same record. We consider two types of LLM-induced artifacts: bloat, in which LLM-generated summaries accumulate in the record and change the length and provenance of its content over time; and distortion, in which LLMs subtly alter clinical findings rather than fabricating facts outright. As a case of distortion, we study diagnostic overcall (documenting an unconfirmed differential diagnosis in the record) and test whether it propagates to the reader LLM's output. Across seven reader models from four families, we find evidence of both effects. First, LLM-generated summary notes modestly but consistently degraded downstream hospital-course generation compared with copy-forward and templated text of matched length. Second, injected overcalls reappeared in downstream outputs at rates that varied by reader model, without detectable changes in standard quality metrics. These findings show the need to monitor AI-generated content in medical records and to account for it when those records are later processed by AI.

0.13

When Patients Cut In: Extending Clinical Conversational AI Safety to Interruptions

cs.CL ·2026-08-29 ·Zachary Ellis, Spencer Hazel, Adam Brandt, Yajie Vera He, Ernest Lim +1 more
top venue similarity 0.69
Abstract · Accepted to Findings of EMNLP 2026

Clinical voice agents are now deployed in routine care, where real patients do not wait their turn: they interrupt. These systems typically use a cascaded architecture (speech-to-text -> LLM -> text-to-speech), so when a patient cuts the agent off mid-utterance, clinically required content can be lost even when the model handles cooperative transcripts well. Yet clinical conversational-AI benchmarks almost universally assume patients wait for the agent to finish, missing interruption-induced loss of required content. We present a transcript-based evaluation of interruption recovery, adapting conversation-analytic overlap categories into three operational types (recognitional, competitive, transitional sub-unit) and testing four deployment-oriented, non-reasoning LLM configurations across four cells spanning history-taking (information gathering) and FAQ (information provision), scored on whether the agent preserves the clinically required content. In the gathering cells, target-question failure varied across models; in the provision cells, where arms are directly comparable, failure rose for every model. Rankings differ across cells, and competitive FAQ interruption produced 30/30 provision-coverage failures for all four models (Wilson 95% CI: 88.6-100.0%; baseline 0/30 for three, 4/30 for Llama). A brief apology marker ("sorry to interrupt") shifts recovery by tens of percentage points, inconsistently across models, and for one it reduces recovery. Interruption robustness therefore cannot be a single score: evaluation must be content-grounded, reported per cell, and matched to the deployment's interruption profile.

0.33

Knowledge Graph-Augmented Ambient AI for Clinical Note Generation

cs.CL cs.AI ·2026-09-04 ·Jakir Hossain, Yi-Fei Zhao, Hongjian Wang, Minmei Shih, Katie Leigh Mullen +7 more
similarity 0.68
Abstract

Ambient AI is increasingly adopted in healthcare to automatically generate clinical notes from patient-clinician conversations, with the potential to substantially reduce clinician documentation burden. However, generated notes may omit clinically relevant information discussed during the encounter, creating information gaps that can affect downstream care. Knowledge graphs (KGs) constructed from encounter transcripts can provide a structured representation of what was discussed and enable systematic identification of missing information from generated notes that are critical for patient care. In this study, we introduce Coverage-Directed Revision (CDR), a model-agnostic framework that constructs a KG from the encounter transcript, identifies medical concepts absent from an initially generated note, and directs large language models (LLMs) to restore the missing information without modifying the underlying note-generation system. We evaluate CDR on two datasets: 1) Pitt-Bench, a local dataset comprising rehabilitation sessions, and 2) ACI-Bench, a public dataset for benchmarking clinical note generation. We tested four underlying LLMs widely used in ambient AI systems. The results show that CDR consistently improves content recall across all evaluated conditions. Our study provides a practical approach for improving the completeness of ambient AI-generated clinical documentation.

0.16

ASCRIBE: Atomic and Significance-Based Reasoning for Thai Clinical SOAP Note Generation

cs.CL ·2026-10-01 ·Tarm Kalavantavanich, Teerawut Ponarchar, Pattaramanee Arsomngern, Jenta Wonglertsakul, Watcharakorn Chuthong +3 more
benchmarkcode/data similarity 0.67
Abstract

Automatic SOAP note generation can ease the documentation burden on physicians, but existing reasoning methods often omit clinically important information and generate unsupported content. Progress in Thai is further hindered by the lack of publicly available datasets. We propose ASCRIBE, a physician-inspired reasoning framework that ascribes a clinical-significance level to each extracted atomic fact in the conversation before summarization, making a general-purpose LLM a more reliable scribe. We also release ThaiClinicBench, the first de-identified Thai clinical summarization benchmark of real encounters, together with a synthetic training corpus derived from real clinical notes. As a prompt, ASCRIBE outperforms chain-of-thought prompting on GPT-5.4 and Gemini 3.1 Pro across the physician-aligned LLM-judge metrics and improves on standard prompting by up to 10.3 points on the completeness LLM-judge metric. As a GRPO reward, it enables a Gemma-4-E4B model trained solely on synthetic data to match Gemini 3.1 Pro in factual precision and surpass it in completeness. Code and data can be found at https://github.com/loolootech/ascribe.

0.34

ROUNDS: Source-Framed Diagnostic Revision after Multi-Turn Clinical Evidence

cs.CL cs.AI ·2026-11-14 ·Jinrui Fang, Runhan Chen, Yining Wu, Jiawei Xu, Xu Yang +4 more
top venuebenchmark similarity 0.67
Abstract · Accepted at Machine Learning for Health (ML4H) 2026, Proceedings Track; to appear in Proceedings of Machine Learning Research (PMLR). 17 pag…

Large language models (LLMs) achieve high scores on medical benchmarks, but does this performance translate into reliable diagnosis as a conversation unfolds? In diagnostic conversations, users can provide clinical findings across multiple turns, ask for a diagnosis without supplying answer options, and introduce opinions from others. Models must therefore form diagnoses from the available evidence and decide how to respond to subsequent advice. We introduce ROUNDS, a framework that evaluates these abilities after a fixed sequence of clinical evidence delivered over multiple turns. ROUNDS compares diagnosis with and without answer options, presents the same incorrect diagnosis under clinician and lay framing, and varies support for competing diagnoses in written five-clinician panels. Across seven models and 1,035 cases from five datasets, average accuracy was 76.9% with answer options and 57.0% without them. Clinician-framed misleading advice produced lower final accuracy than lay-framed advice in every model, with differences of 4.6 to 38.2 percentage points. Initially correct diagnoses more often became incorrect answers than abstentions, and many adopted the suggested disease. Conversely, accuracy increased as more panel members supported the correct diagnosis, including when the majority opinion remained unchanged. These findings reveal a gap between medical benchmark performance and reliable diagnosis in conversation: models respond to external opinions, but remain vulnerable to abandoning correct diagnoses without new clinical evidence.

0.34

Clinical Concept Centers in LLMs

cs.CL cs.LG ·2026-10-02 ·Aishik Nagar, Abhishek Vaidyanathan, Arun-Kumar Kaliya-Perumal, Elijah Tzen Hsuen Boey, Stefan Winkler
similarity 0.67
Abstract

Large language models are increasingly used in clinical settings. However, research into the reliability and performance of these models has focused almost entirely on the language substrate, scoring what the model says. Mechanistic interpretability has found that the latent space carries a higher fidelity of representation than the text: internal representations not only encode substantially more than the output verbalizes, but the stated reasoning also systematically omits features that causally drive the answer. An evaluation of model behavior in terms of mechanistic interpretability has not been explored in clinical decision support. In this work, we extend behavioral evaluation into the latent space and ask whether clinical concepts exist as locatable, causally used representations inside open-weight LLMs. We find dedicated clinical concept centers in the latent space of all eleven open models we test. These concept centers are interpretable, firing only on their aligned clinical narratives, and meaningfully and causally drive model behavior in both constrained and open-ended settings. They are not just analytical representations, but circuits that can be utilized in clinical practice, and we explore their use from the perspective of both evaluation and performance. From the evaluation standpoint, models stay internally coherent and keep using the relevant concept centers even under adversarial role-based priming, while aligned priming improves downstream clinical performance. From a performance perspective, we simulate realistic deployment settings and find that steering models along these centers leads to meaningful downstream improvements. Finally, we conduct a blinded clinician validation and find the activation and usage of these concept centers predicts clinicians preferences.

0.27

Can LLMs Reason Over Long Horizons? An Empirical Evaluation of Context Strategies for Longitudinal Clinical Reasoning

cs.CL cs.AIcs.LG ·2026-09-30 ·Taye Akinrele, Noorbakhsh Amiri Golilarz, Subash Neupane, Sudip Mittal, Shahram Rahimi
similarity 0.66
Abstract

Longitudinal clinical reasoning requires large language models (LLMs) to identify and integrate relevant evidence distributed across extended patient histories. Although long-context models can process increasingly large amounts of information, providing more history does not necessarily make relevant evidence more accessible or improve reasoning. We compare five context strategies (Full, Recent, Episodic, Semantic, and Hybrid) on MedLoCoMo across four open-weight LLMs, examining answer correctness, robustness to query-evidence distance, and abstention on questions with unsupported premises. Episodic and Hybrid generally achieve the strongest overall accuracy, while Recent Context degrades most as supporting evidence becomes more distant; Episodic and Hybrid maintain the highest accuracy at long distances. Analysis of adversarial questions further shows that strong performance on answerable questions does not necessarily translate to successful abstention when the available history does not support the requested conclusion. These findings show that reliable longitudinal reasoning depends not only on how much history an LLM can access, but critically on how relevant evidence is selected and presented for reasoning.

0.18

Verification Turns Capability Gaps into Routing Decisions: Small Language Models for Clinical Documentation

cs.AI ·2026-10-13 ·Nina Fatehi, Meysam Ghaffari, Animesh Agarwal, Anushka Swarup, Carlos Morato
similarity 0.66
Abstract

Clinical note generation from doctor--patient dialogue is high-volume and hallucination-intolerant: a fabricated laboratory value can create patient-safety risk, not a quality regression. We ask whether an agentic \emph{verification} architecture, rather than generator scale, can make a small language model viable here. Holding a four-evaluator verification stack and refinement policy fixed and swapping only the generator between a 4B-parameter model with a QLoRA adapter and a frontier baseline, the small model reaches $0.984$ claim-level factual entailment against $0.992$ and comes within $3.3$ points on completeness, generating entirely on-device. Its deficit is confined to \emph{inter-section structural fidelity}---arrangement rather than clinical comprehension, and the axis on which it also falls furthest below the corpus's reference notes. Because that deficit is an explicit verifier decision rather than a silent quality difference, it becomes a routing policy: run the small model by default, escalate what the verifier rejects. Measured end to end, that it achieved a similiar verified-rate acceptance to the frontier-only acceptance in this test set ($99.6\%$ vs.\ $98.4\%$ over $250$ encounters) while routing $62$, documenting three quarters without a frontier \emph{generation} call. Ablating the loop separates architecture from scale: unrefined, the small model is accepted on $26.8\%$ of encounters and the frontier model on $74.8\%$, so verification does the most work where the generator is weakest. We also contribute section-scoped refinement, which preserves unflagged sections by construction rather than instruction, and find the baseline is not uniformly stronger---its provider refused two trauma-related transcripts the on-device model handled and certified, one facet of a provider dependency a served adapter does not carry.

0.27