CS Paper Radar

Bound-Aware Per-Organ Recall Risk Control for Multi-Organ CT Segmentation under Clinical Domain Shift

Souraj Adhikary, Negar Chabi, Andre Mastmeyer

cs.CV cs.AIcs.LG ·submitted 2026-08-18 15:01 UTC · v1
published

Abstract

Distribution-free risk control adds organ-specific recall guarantees to frozen segmentation. We calibrate per-organ thresholds for an AMOS-trained nnU-Net, audit transfer to RAOS, and estimate local re-certification cost using case-level voxel false-negative rate (FNR). The AMOS control passes, but $7/12$ organs exceed $α{=}0.10$ after transfer; smaller calibration sets can mask exceedances with conservative or vacuous thresholds. Risk-Controlling Prediction Sets (RCPS) give high-probability control of population-mean risk, whereas Conformal Risk Control (CRC) gives weaker expectation control. Both require exchangeability; fixed and global thresholds give no per-organ guarantee. The Waudby--Smith--Ramdas (WSR) betting bound re-certifies six Tier-1 organs with 25 local cases, versus 30--40 for Hoeffding--Bentkus (HB). CRC needs 10--15 but has a heavier individual-case tail. No Tier-2 organ meets our illustrative precision criterion with 25 cases.

Comment
12 pages, 4 figures, 2 tables
Journal ref
MICCAI-UNSURE 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Risk Control Certifies Rates, Not Magnitudes: An Audit of Selective Fetal Biometry

cs.AI cs.CV ·2026-11-04 ·Zhengshuai Yang, Linna Jiang, Changyun Li, Guihu Zhao
theory similarity 0.64
Abstract · 10 pages, 2 figures, 3 tables

Prenatal ultrasound biometry must return a head circumference (HC) and refuse when the image cannot support one. Selective prediction trades coverage against error, but its finite-sample guarantees bound the rate of gross errors, not their magnitude. We audit a tool-grounded biometry pipeline on two separately pre-registered four-way splits of the 999 labelled HC18 images, retraining the segmenter three times on each. Calibrating the contour-completeness threshold by exact Clopper-Pearson risk control returns a certificate indistinguishable from a hand-set floor, yet the pipeline still emits a 271.3 mm error: a small, geometrically complete ring fitted to an image whose true HC is 324.6 mm. The accepted candidate scores 0.94 completeness, so the score cannot see the failure, and one outlier among $\approx 150$ answers leaves the certified risk bound ($α= 0.10$) intact. A second, untouched split reproduces the mechanism on a different image (233.3 mm). Constraining the admissibility region---the anatomical range in which the measurand is defined---removes the family instead: raising the lower bound from 50 to 55 mm costs 0.4 coverage points and cuts the worst-case error on both splits to 11.4 and 11.1 mm, whereas suppressing it through the completeness threshold costs 19.0 and 12.1 points. At an anatomically defined 70 mm the frozen tests give 1.91 and 1.81 mm MAE.

0.30

Region-aware error triage for medical image segmentation with groupwise conformal risk control

cs.CV ·2026-11-06 ·Nishi Kanta Paul, Md Shihabul Islam Shovo, Hoileong Lee
similarity 0.63
Abstract · 22 pages, 7 figures, 12 tables. Submitted to Biomedical Signal Processing and Control (BSPC)

Segmentation masks are increasingly reviewed rather than redrawn, which requires knowing where a mask is likely wrong. Learned error maps rank pixels by risk, but the number of pixels to warn is chosen ad hoc, and calibrating one warning threshold over all error pixels may leave errors far from the predicted contour under-flagged. We propose RACE-Triage, a post-hoc error triage framework that leaves the segmentation mask unchanged. A risk network is trained on out-of-fold predictions from backbone-independent inputs. The predicted contour partitions each image into a boundary band and a non-boundary region, and conformal risk control is applied separately in each region to bound the expected fraction of missed errors among cases with errors there. On ISIC 2018 dermoscopy and BUSI breast ultrasound (where patient identifiers are unavailable, so independence across images is assumed), pooled control met its overall target but missed on average 31.8% and 36.4% of non-boundary errors. Regional control reduced these fractions to 19.3% and 20.9% and raised the recall of size-filtered false-negative components from 0.722 to 0.818 and from 0.611 to 0.763. The mean warned area grew by 1.6 and 4.9 percentage points, and its 95th percentile reached 23.5% and 38.5%. The effect held across three seeds and a second backbone, and area-matched heuristics did not reproduce it. On the external PH$^2$ set, frozen thresholds exceeded both targets, whereas recalibration with 100 local images brought the mean over repeated splits below them. Regional calibration improves non-boundary error coverage at a measured increase in warned area.

0.30

ReCIRC: Rectified Conformal Risk Control

cs.LG stat.ML ·2026-09-29 ·Bruno Marcondes e Resende, Helton Graziadei, Thiago Rodrigo Ramos, Rafael Izbicki
similarity 0.61
Abstract · 69 pages, 11 figures

Many applications of black-box predictive models require controlling task-relevant error rates, such as missed lesion pixels in segmentation or missed labels in multilabel classification. Conformal risk control (CRC; Angelopoulos et al., arXiv:2208.02814) gives distribution-free guarantees for such losses, but it calibrates a single threshold shared by all inputs. Because conditional risk varies with the input, this marginal guarantee often overprotects easy cases and underprotects hard ones. We propose ReCIRC (Rectified Conformal Risk Control), which inverts each input's estimated local risk curve to reparameterize the calibrated threshold as a risk budget $a$ representing a common target conditional risk, and then applies CRC unchanged to the resulting family. ReCIRC retains CRC's finite-sample marginal guarantee regardless of the accuracy of the estimated curves, while accurate curves yield approximate conditional risk control and, under additional conditions, asymptotically exact conditional risk control; they also support a risk-calibration diagnostic. Across three synthetic and five real-data settings spanning segmentation, multilabel and multiclass classification, and regression, ReCIRC attained the lowest average worst-group risk and mean positive group excess in every setting, while maintaining marginal risk close to the target, whereas changes in prediction size were application-dependent.

0.54

Quantifying Volumetric Risk: Class-Aware Asymmetric Weighted Conformal Prediction for 3D Medical Image Segmentation

cs.CV ·2026-10-07 ·Shadi Alijani, Fereshteh Aghaee Meibodi, Homayoun Najjaran
benchmarktheory similarity 0.60
Abstract

Reliable volumetric segmentation is critical for clinical diagnostics, yet foundation models such as MedSAM remain deterministic and lack calibrated uncertainty under distribution shift. Existing conformal prediction methods offer statistical guarantees but are frequently applied in 2D and assume symmetric error distributions, so they do not capture the class-specific biases that arise in 3D multi-class segmentation. We propose Class-Aware Asymmetric Weighted Conformal Prediction (CA-WCP), which combines latent-space density-ratio weighting for covariate shift with directional quantiles for the lower and upper volume bounds, and scales each bound by a class-specific asymmetry factor derived from validation-set false-positive and false-negative rates. We prove that CA-WCP retains the weighted-exchangeability marginal coverage guarantee for every class, and we evaluate it on 3D brain tumor segmentation (BraTS 2020) and on a synthetic multi-organ CT benchmark constructed under covariate shift. On both benchmarks the 95\% Clopper--Pearson interval for the observed coverage of CA-WCP contains the nominal 90\% level for every semantic class, while interval width is reduced by 8--14\% relative to symmetric weighted conformal prediction. We further encode the calibrated intervals into structured prompts for a multimodal large language model to produce uncertainty-conditioned radiology reports, linking distribution-shift-aware uncertainty quantification to interpretable clinical communication.

0.15

Certify, Report, or Refuse: Harm-Constrained Conformal Prediction for Clinical Actions

cs.LG cs.AI ·2026-11-09 ·Zhiyuan Li, Lequan Yu
similarity 0.58
Abstract · Findings of the 6th Machine Learning for Health Symposium (ML4H 2026)

Routing a melanoma case to routine follow-up is a serious action error that diagnostic coverage alone does not rule out. We present Harm-Constrained Risk-Optimal Conformal Prediction (HC-ROCP), a training-free framework that uses frozen classifier probabilities and adds a harm penalty when choosing prediction sets and actions. We test the resulting policies on disjoint calibration splits with multiplicity adjustment. HC-ROCP certifies supported claims, reports descriptive fallback policies, and refuses unsupported subgroup claims. We evaluate these outputs retrospectively on COVID-19 radiographs, ISIC 2019 dermoscopy, and EyePACS-to-APTOS retinopathy transfer. Across ten calibration seeds, HC-ROCP reduces COVID-19 severe-action errors from the exact risk-optimal baseline's 4.68\% to 0.54\%. At a 5\% budget, global claims are certified for COVID-19 and ISIC, but the rare squamous-cell-carcinoma claim is refused. At 1\%, all settings receive descriptive reports. For each budget, we also report the minimum severe-case count needed to pass the global harm gate with zero errors, providing a starting point for further data collection.

0.15

Conditional Validity for Adaptive Modality Acquisition: When the Policy Chooses Its Own Calibration Group

cs.LG ·2026-08-16 ·Melika Baghi
similarity 0.57
Abstract · 23 pages, 4 figures, 14 tables. Includes appendix with full proofs

A multimodal system may begin inference while holding only some of its inputs and may acquire the rest at a cost. With adaptive acquisition, the policy determines which inputs are ultimately observed, so we state risk control conditional on that terminal input pattern. Conditional calibration typically assumes that the grouping map is fixed independently of the calibration sample, a condition that policy-induced grouping does not satisfy. We characterize when pattern-conditional risk control remains valid and give two finite-sample constructions: threshold-free routing with calibration applied at the terminal pattern, and simultaneous validation of complete policy-pattern pairs, which lets calibration data select the deployed policy. A counterexample shows that validity proved for a calibration-independent grouping map need not transfer once the policy makes the terminal group calibration-dependent. We call the resulting method RouteCert. On a clinical electrocardiogram task with a staged, cost-ordered lead protocol, the deployed policy answers 71.2% of held-out patients, with an observed 7.4% disagreement with the cardiologist's diagnosis at 48.8% of the prespecified ordinal cost of acquiring each stage, and all three acquisition stages are validated separately. On masked multimodal benchmarks, validating pointwise at each terminal pattern holds observed worst-pattern selective risk, measured against the full-information reference decision rather than the true label, at 0.034, where a pooled design reaches 0.145 against a 0.10 cap, at a comparable answered fraction (0.350 vs 0.342); under the budget-matched simultaneous comparison, the answered fraction falls to 0.305.

0.10

ThreshGuide: Class-Aware Labeled-Guided Thresholding for Semi-Supervised 3D Abdominal Multi-Organ Segmentation

cs.CV ·2026-09-14 ·Hongyu Liu, Yinlong Wang, Lusha Li, Hui Meng
similarity 0.57
Abstract · 16 pages, 10 figures

Pseudo-labeling is a strong paradigm for semi-supervised medical image segmentation, yet its effectiveness is highly sensitive to confidence thresholding. In abdominal multi-organ segmentation, a fixed global threshold is particularly suboptimal because organ classes differ substantially in size, appearance, and learning difficulty. In this work, we propose ThreshGuide, a class-aware threshold adaptation framework that uses labeled data to guide pseudo-label selection on unlabeled data. Built upon a standard teacher-student architecture, the teacher model evaluates labeled samples during training to estimate class-aware threshold targets by maximizing an error-aware F\b{eta} criterion that balances precision and coverage. These targets are then smoothed with an exponential moving average (EMA) and used to filter unlabeled voxels in a class-dependent manner. Experiments on FLARE2022 and AMOS2022 show that ThreshGuide performs competitively overall, yielding clear improvements specifically on hard-to-learn organs.

0.19

Group-Conditional Conformal Risk Control: Exact Guarantees, Limits, and Overlapping Extensions

cs.LG stat.MLmath.ST ·2026-11-07 ·Tareq Aldirawi, Wenge Guo
similarity 0.56
Abstract · 68 pages, including 40 pages of appendices

We study group-conditional conformal risk control (CRC) for disjoint and overlapping groups under bounded monotone losses. For disjoint groups, we establish exact finite-sample conditional risk control, two-sided bounds on the group-restricted risk, and fundamental limitations arising from local support and calibration-rank granularity. For overlapping groups, we study two exactly valid approaches: group-restricted calibration followed by union deployment, and direct calibration of the deployed prediction-set family. We characterize the union's limiting reconciliation gap, identify conditions for its disappearance, and establish sharp lower bounds for structured losses in specified product-form models. We also demonstrate a strict size advantage for direct calibration in an ordinal model. Experiments show that direct calibration can reduce prediction-set size, but its efficiency depends on group structure, loss type, and shape fitting. Results on historical diabetic-retinopathy scores further illustrate these tradeoffs. Overall, local support, reconciliation slack, and threshold heterogeneity determine efficiency, with neither approach uniformly dominating.

0.28