CS Paper Radar

Cross-Modal MRI Ovary Segmentation in Endometriosis Using Unpaired TVUS Prototype Priors

Xingjian Kang, Lina Felsner, Dominik Perrin, Daiqi Liu, Jasmin Arjomandi, Franziska Mathis-Ullrich, Alexandra Stoll, Katharina Breininger

cs.CV ·submitted 2026-08-19 04:09 UTC · v1
unusual

Abstract

Transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI) provide complementary information for endometriosis image analysis, yet existing studies mainly focus on single-modality analysis or disease classification, leaving cross-modal ovarian segmentation largely unexplored. In this work, to tackle the increased difficulty of ovary segmentation in MRI due to ovaries' small target size and ambiguous boundaries with surrounding pelvic structures, we propose a dual branch framework for ovary segmentation across TVUS and MRI. More specifically, by adapting MedSAM3 with TVUS-derived prototype bank, we aim to align anatomically consistent feature representations across both modalities. Extensive experiments are conducted on endometriosis-related TVUS and MRI datasets. We observe quantitative and qualitative improvements of over 5 percentage points for the proposed dual-branch approach compared with multiple state-of-the-art methods. Furthermore, our ablation study shows the contribution of individual components such as the prototype bank and the importance of warm-up pretraining in the source TVUS domain.

Closest papers

Nearest neighbours by meaning across the whole index.

Topology-Informed Prompt-Conditioned Universal Segmentation of Uterine Structures from Ultrasound and MRI

cs.CV cs.AI ·2026-10-05 ·Yongheng Sun, Yuexi Gu, Jingwen Sun, Maureen Kohi, Mingxia Liu
code/data similarity 0.60
Abstract · 4 pages, 2 figures, 3 tables. Code: https://github.com/YonghengSun1997/TPUS

Multi-structure segmentation of the uterus is important for computer-assisted screening, diagnosis, and treatment planning of uterine diseases, where ultrasound and MRI provide complementary clinical information. However, developing a unified model across these modalities is challenging due to their substantially different image appearances, anatomical contexts, spatial resolutions, and label spaces. Moreover, existing datasets often define different segmentation targets, making joint learning challenging and potentially leading to negative transfer across heterogeneous tasks. To this end, we propose a Topology-informed Prompt-conditioned Universal Segmentation (TPUS) framework for segmenting multiple uterine structures across ultrasound and MRI. TPUS introduces a graph-based multi-dataset backbone comprising modality-specific stems and a modality-shared graph-based encoder-decoder to support modality-sensitive input adaptation, structural feature reasoning, and joint representation learning across heterogeneous uterine segmentation tasks. In addition, TPUS uses task-aware class prompts to condition the segmentation process for different datasets and label spaces, a dynamic convolutional adaptation module to generate task-specific output responses, and a topology-informed loss to encourage anatomically consistent predictions. Experiments on a uterine ultrasound dataset and a T2-weighted uterine myoma MRI dataset demonstrate that TPUS achieves Dice scores of 0.898 and 0.693 on the two held-out test sets, respectively, outperforming several generic and universal segmentation baselines. Source code can be accessed at https://github.com/YonghengSun1997/TPUS.

0.30

PelviNeXt: A Modality-Agnostic Hybrid Network for Pelvic Imaging in Women's Health

cs.CV ·2026-08-20 ·Siam Tahsin Bhuiyan, Rashedur Rahman, Sefatul Wasi, Halima Khatun, Ashraful Islam +3 more
publishedbenchmark similarity 0.59
Abstract · Accepted at MICCAI CAPI-WOMEN 2026

Women's health remains substantially under-resourced in medical imaging research, with pelvic pathologies such as polycystic ovary syndrome (PCOS) and pelvic fracture both suffering from a scarcity of public, well-annotated benchmark data despite their clinical importance. We introduce PelviNeXt, a modality-agnostic hybrid architecture combining a dense convolutional feature extractor, hierarchical channel-spatial attention (H-CBAM), a multi-scale fusion module (MSFM), and talking-heads multi-head self-attention (TH-MHSA), applied without modification to both pelvic ultrasound and X-ray inputs. While benchmarking PelviNeXt on PCOSGen, the only gynaecologist-annotated public PCOS ultrasound dataset, we identified extensive exact and near-duplicate contamination within and across the dataset. We audit this contamination via perceptual hashing, publicly release a deduplicated version of the dataset, and establish the first integrity-audited evaluation protocol and baseline for PCOSGen under 5-fold cross-validation. On the only publicly available pelvic fracture X-ray dataset (PXR150), PelviNeXt exceeds previously reported state-of-the-art results across accuracy, recall, specificity, and AUROC. Ablation studies confirm that each architectural component contributes to performance on both tasks. Our results demonstrate that a single architecture, applied without task-specific modification, can serve as a reliable foundation for pelvic imaging across modalities in data-scarce, under-researched areas of women's health.

0.51

Parameter-Efficient Multimodal Brain Tumor Segmentation With Stage-Wise Shared Adapters

cs.CV ·2026-10-13 ·Milad Rostamian, Mohammadreza Mohammadi, Ender Konukoglu, Mohsen Soryani
similarity 0.58
Abstract

Different MRI modalities reveal different parts of a brain tumor. Segmentation models combine information from these modalities to outline tumor regions. Many models use a separate encoder for each modality. However, exchanging features among these encoders at several stages can increase model complexity. We introduce the Block-Wise Shared Adapter (BWSA), which combines compressed features from the modality encoders in a shared path and returns adapted features to each stream. In its fixed-blending form, BWSA adds the adapted features to the original features. Its trainable-gated variant (TG-BWSA) instead learns separate weights for the original and adapted features at each modality and encoder stage. We evaluate both variants on BraTS 2020 and BraTS 2023 with four segmentation backbones. On the official BraTS 2023 online validation set, BWSA increases average region-wise Dice by 1.3--7.6 percentage points relative to the corresponding unmodified backbones. TG-BWSA increases it by 2.8--7.7 points. Both variants add approximately 0.85--3.73% parameters and reduce average HD95 relative to the unmodified backbones.

0.34

End-to-end prostate lesion segmentation and detection from undersampled diffusion-weighted MRI

cs.CV physics.med-ph ·2026-10-24 ·Lukas T. Rotkopf, Marco Schlimbach, Kevin Kröninger, Stefan O. Schoenberg, Heinz-Peter Schlemmer +2 more
similarity 0.57
Abstract

Automated prostate lesion detection from diffusion-weighted MR imaging (DWI) conventionally relies on reconstructed images and does not fully use all acquisition information. We present an end-to-end network that uses complex multicoil DWI data and coil sensitivity information for prostate lesion segmentation. We included 269 fastMRI prostate examinations with additional voxel-level lesion annotations. Of these, 64 examinations contained PIRADS 4 or 5 lesions. The proposed network, VarNet-Seg, consists of a k-space variational network (VarNet) with six variational cascades and an image-space 3D segmentation U-Net. Comparator models used the same segmentation architecture with fully coil-combined images (CC-Seg), fixed root-sum-of-squares reconstruction (RSS-Seg), or fixed SENSE reconstruction (SENSE-Seg). We performed ablations with end-to-end training and data consistency (DC) enabled or disabled. We evaluated lesion segmentation using Dice and patient-level detection using AUROC in five-fold cross-validation with full sampling, simulated undersampling, added noise, or both. VarNet-Seg achieved the highest Dice at every undersampling level. At eight-fold acceleration, Dice was 0.22 for VarNet-Seg, 0.14 for SENSE-Seg and 0.16 for VarNet-Seg (no DC). The paired difference from SENSE-Seg was 0.08 (95% CI, 0.04-0.11). With full sampling, VarNet-Seg and RSS-Seg performed similarly (0.40 vs 0.39). Patient-level AUROC decreased from 0.75 with full sampling to 0.63 at eight-fold acceleration; corresponding RSS-Seg AUROCs were 0.76 and 0.64. The proposed multicoil network improved prostate lesion segmentation under simulated undersampling compared to conventional models. Matched ablations supported contributions from both end-to-end training and data consistency. Prospective evaluation is needed to establish whether this approach can be used clinically in accelerated prostate DWI.

0.31

Multicentre Bi-atrial Segmentation from LGE-MRI for Atrial Fibrillation with a 2D and 3D Framework

eess.IV cs.CV ·2026-09-18 ·Malitha Gunawardhana, Gregory B. Sands, Mark L. Trew, Jichao Zhao
publishedbenchmark similarity 0.55
Abstract · Accepted at Biomedical Signal Processing and Control Journal

Accurate delineation of bi-atrial structures from late gadolinium enhancement MRI (LGE-MRI) is an important prerequisite for structural analysis and future fibrosis-quantification workflows in atrial fibrillation (AF). However, automated segmentation is challenging due to thin-walled anatomy, domain shifts across imaging centres, and limited benchmarking of existing methods. This study presents a two-stage segmentation framework and benchmarking platform for evaluating how ROI localisation, encoder design, 2D/3D dimensionality, and ensemble fusion affect bi-atrial wall and cavity segmentation across multicentre LGE-MRI datasets. The framework integrates 3D localisation and fine segmentation using 2D and 3D U-Net variants with ResNeXt encoders and compares them with convolutional, transformer-based, and state-space architectures. { Evaluation across three independent cohorts assessed accuracy and cross-domain transfer without target-domain fine-tuning. Cavity segmentation transferred more consistently across centres than atrial wall segmentation, while wall performance remained sensitive to domain shift, particularly in the Kobe cohort.} By quantifying how 2D, 3D, and ensemble architectures behave across centres and between walls and cavities, this work provides a reproducible benchmark for future methodological development and clinical validation.

0.36

WASP: Weakly Aligned Spatiotemporal Pairs for Fetal Brain MRI-Ultrasound Learning

cs.CV cs.LG ·2026-10-03 ·Francesco Correnti, Gabriele Magrini, Marco Mistretta, Niccolò Biondi, Pietro Pala +4 more
top venuecode/data similarity 0.55
Abstract · Accepted at NeurIPS 2026. 21 pages, 3 figures, 11 tables. Code: https://github.com/miccunifi/WASP

Magnetic Resonance Imaging (MRI) is widely regarded as the optimal sensor for fetal brain analysis due to its superior soft-tissue contrast and anatomical detail. However, its high cost and operational burden make it invasive and difficult to obtain at scale. Ultrasound (US), in contrast, is cheap, safe, and routinely acquired, and as a result it has produced substantially larger datasets and a growing ecosystem of pretrained models. This asymmetry raises a natural question: Can we teach a US-only model to understand fetal MRI from only a limited set of examples? The standard recipe, training a foundation model on subject-to-subject paired MRI-US scans, is not viable since no such paired fetal dataset is publicly available. In this paper we address this gap with Weakly Aligned Spatiotemporal Pairs (WASP), a framework that formulates cross-modal correspondence as an entropic Optimal Transport problem driven by clinical metadata, in particular Gestational Age (GA) and diagnostic planes, enabling the fitting of a lightweight alignment module that lifts MRI representations into the US latent space, without fine-tuning the backbone. Empirically, WASP yields its largest gains when MRI is unseen by the model during pretraining (on USFM, GA estimation error drops from 21.9 to 17.4 days and standard plane classification accuracy climbs from 61.9% to 69.0%), while providing smaller, backbone-dependent refinements for backbones pretrained on both modalities (e.g., BioMedParse GA estimation error from 6.5 to 6.0 days and SAM-Med2d plane accuracy from 83.3% to 88.1%). Code is available at https://github.com/miccunifi/WASP.

0.46

CAPS: Clinically-Verifiable Anatomy-Prioritized Synthesis for Missing MRI Imputation in Brain Tumor Segmentation

eess.IV cs.CV ·2026-10-20 ·Cecilia Diana-Albelda, Arthur Longuefosse, Mario Rubén Paz Campos, Álvaro García-Martín, Jesus Bescos
similarity 0.55
Abstract · 20 pages, 6 figures, 8 tables. Cecilia Diana-Albelda and Arthur Longuefosse contributed equally

Multi-parametric MRI is the gold standard for neuro-oncology, yet acquiring complete 4-modality protocols may be unfeasible in real-world clinical practice. When handling missing modalities, existing automated systems force a critical compromise: robust segmenters operate as uninterpretable "black boxes" that bypass image generation, while standard synthesis models often produce blurry reconstructions lacking diagnostic reliability. To address this issue, we propose CAPS, a Clinically-Verifiable Anatomy-Prioritized Synthesis framework that reconciles computational precision with clinical transparency. Our multi-modal generative architecture is driven by a hybrid objective function (L_1 + L_AFP + L_DualDice) that explicitly enforces the preservation of deep anatomical features and strict topological boundaries, rather than relying solely on pixel-wise optimization. Evaluated comprehensively on the BraTS Adult Glioma dataset, the framework achieves superior synthesis fidelity across intensity-based metrics, and demonstrates robust downstream segmentation performance (82.38% mean Dice), successfully restoring verifiable visual context. Furthermore, the framework exhibits exceptional zero-shot cross-domain generalization, maintaining high structural fidelity across completely unseen Meningioma, Pediatric, and Sub-Saharan African cohorts without domain-specific adaptation. Finally, a blinded radiological assessment confirms that our anatomy-aware approach significantly enhances both perceived image quality and clinical utility, providing clinicians with the reliable visual evidence required to trust downstream automated workflows.

0.20

VGG16-MCA UNet: Whole-Tumor Segmentation in 2D FLAIR MRI with Decoder-Side Channel Attention

eess.IV cs.CV ·2026-09-20 ·Shubham Gajjar, Deep Joshi, Avi Poptani, Vishal Barot
benchmarktheorycode/data similarity 0.55
Abstract · 22 pages, 7 figures, 4 tables. Code and data splits: https://github.com/ShubhamGajjar/vgg16-mca-unet

Automated brain tumor segmentation supports diagnosis, treatment planning, and monitoring of disease progression, but building models that generalize across heterogeneous tumors and limited annotated data remains difficult. We present VGG16-MCA UNet, a hybrid architecture pairing an ImageNet-pretrained VGG16 encoder with a decoder in which a Multi-Channel Attention (MCA) module recalibrates features after each skip-connection fusion, trained with the Focal Tversky loss to counter severe foreground-background imbalance. We evaluate the model as a 2D, FLAIR-only, whole-tumor segmenter on tumor-positive slices from two public datasets: the BraTS 2020 benchmark and the LGG MRI Segmentation dataset. Using 5-fold cross-validation and a single network formed by averaging the weights of the five fold models, the method attains an aggregate pixel-level Dice (F1) of 95.10% on our held-out BraTS 2020 split and 88.32% on LGG. These scores are computed over all test pixels pooled into a single confusion matrix rather than averaged per case, and are therefore not directly comparable to the per-case mean Dice used in the BraTS challenge protocol. All partitions were drawn over individual slices rather than over patients, so every patient contributes slices to both training and test; the figures above therefore measure interpolation within known patients and should be read as an upper bound rather than as generalization to new ones. The model segments a 256x256 slice in 66.32 ms on a single 6 GB NVIDIA RTX 2060, approximately 8 ms more than an equivalent VGG16-UNet without MCA. We release the split records and report the protocol in full, with the aim of providing a precisely specified and reproducible 2D FLAIR baseline.

0.23