CS Paper Radar

Multicentre Bi-atrial Segmentation from LGE-MRI for Atrial Fibrillation with a 2D and 3D Framework

Malitha Gunawardhana, Gregory B. Sands, Mark L. Trew, Jichao Zhao

eess.IV cs.CV ·submitted 2026-09-18 10:58 UTC · v1
publishedbenchmark

Abstract

Accurate delineation of bi-atrial structures from late gadolinium enhancement MRI (LGE-MRI) is an important prerequisite for structural analysis and future fibrosis-quantification workflows in atrial fibrillation (AF). However, automated segmentation is challenging due to thin-walled anatomy, domain shifts across imaging centres, and limited benchmarking of existing methods. This study presents a two-stage segmentation framework and benchmarking platform for evaluating how ROI localisation, encoder design, 2D/3D dimensionality, and ensemble fusion affect bi-atrial wall and cavity segmentation across multicentre LGE-MRI datasets. The framework integrates 3D localisation and fine segmentation using 2D and 3D U-Net variants with ResNeXt encoders and compares them with convolutional, transformer-based, and state-space architectures. { Evaluation across three independent cohorts assessed accuracy and cross-domain transfer without target-domain fine-tuning. Cavity segmentation transferred more consistently across centres than atrial wall segmentation, while wall performance remained sensitive to domain shift, particularly in the Kobe cohort.} By quantifying how 2D, 3D, and ensemble architectures behave across centres and between walls and cavities, this work provides a reproducible benchmark for future methodological development and clinical validation.

Comment
Accepted at Biomedical Signal Processing and Control Journal

Closest papers

Nearest neighbours by meaning across the whole index.

A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

cs.CV cs.AI ·2026-08-12 ·Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim +4 more
published similarity 0.66
Abstract · Acceteed by Medical Physics 2026

Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy. The LAD is extremely small, has poor soft-tissue contrast, and varies substantially across patients; even manual contours show limited inter-observer agreement, underscoring the ambiguity of the vessel boundaries. Purpose: To develop a transformer-based framework that improves LAD delineation in low-contrast, imbalanced CT through local-global context modeling and uncertainty-guided optimization. Methods: We propose NA-UNETR, a 3D transformer-based segmentation model whose Neighborhood Attention (NA) and Dilated NA (DiNA) blocks jointly capture fine structural detail and long-range context. Given the scarcity of annotated LAD data, the model is pretrained on 1,000 CTA volumes of general coronary anatomy and fine-tuned with LoRA-based parameter-efficient adaptation on 20 free-breathing institutional CT scans. A composite Dice-Focal and Hausdorff loss, dynamically balanced via homoscedastic uncertainty, improves overlap and boundary accuracy. Results: NA-UNETR reached 45.64% Dice, 38.16 mm HD95, and 10.01 mm ASD, improving Dice by 3.10 percentage points over nnU-Net and reducing HD95 by 2.96 mm relative to Swin UNETR, with the strongest boundary accuracy among all models and improved centerline stability. On ImageCAS it achieved 79.49% Dice, 8.89 mm HD95, and 1.02 mm ASD. Ablations confirmed that residual blocks, variable kernels, and uncertainty-weighted loss each contributed. Conclusions: NA-UNETR balances local precision and global context for thin, low-contrast LAD structures, offering a computationally efficient framework for substructure-level cardiac segmentation in radiotherapy planning.

0.52

CMDiff: Left Atrial Scar Segmentation from 3D LGE MRI Using Conditional Mask Diffusion Model: A Feasibility Study

cs.CV ·2026-11-05 ·Jing Zhang, Bastien Bergere, Jonas Leite, Emilie Bollache, Mikaël Laredo +2 more
code/data similarity 0.65
Abstract · 15 pages, 3 figures, 4 tables

Late gadolinium enhancement (LGE) cardiac MRI enables non-invasive assessment of left atrial (LA) scar, an imaging marker associated with atrial fibrillation ablation outcome. However, automatic scar segmentation is hindered by low contrast, the thin atrial wall, scarce labels, and extreme class imbalance. Conditional diffusion offers iterative mask generation, but its suitability for sparse 3D LA scar segmentation remains unclear. To address this gap, we propose Conditional Mask Diffusion (CMDiff), which predicts clean masks using a dynamic-encoder-conditioned 3D sinusoidal UNet. We compared CMDiff with a deterministic baseline on identical cases in five-fold cross-validation of 60 scar-labelled public LASCARQS subjects, with 48 training and 12 held-out cases per fold. CMDiff achieved a scar DSC of 0.47 $\pm$ 0.08, HD95 of 12.89 $\pm$ 6.39 mm, and ASD of 1.91 $\pm$ 0.96 mm, compared with deterministic baseline values of 0.51 $\pm$ 0.08, 10.86 $\pm$ 5.39 mm, and 1.58 $\pm$ 1.03 mm, respectively. Under the same implementation, clean-mask prediction performed substantially better than the noise-prediction configuration evaluated in this study. Thus, CMDiff was technically feasible but did not improve segmentation performance: DSC was lower, and both HD95 and ASD were higher. Direct mask diffusion therefore provides an analytical alternative, but not a competitive performance advance for this task. The source code is publicly available at https://github.com/jizhang02/CMDiff.

0.42

CIRSeg: Coarse-to-Fine Intensity-Robust Liver Segmentation with Source-Free Continual Test-Time Adaptation

cs.CV ·2026-10-07 ·Ruoshi Xu, Mingqi Gao, Shengda Luo, Jingkun Chen
publishedcode/data similarity 0.65
Abstract · Accepted at the CARE 2026 Workshop at MICCAI 2026

Reliable liver segmentation in contrast-enhanced MRI is essential for quantitative hepatic assessment, treatment planning, and longitudinal disease monitoring. However, limited annotated data and scanner- or vendor-dependent intensity variations can cause overfitting and poor generalization to unseen acquisition domains. Moreover, simultaneously achieving robust global localization and precise boundary delineation remains challenging, while predictions may contain isolated false-positive regions outside the main liver component. To address these challenges, we propose CIRSeg, a coarse-to-fine, intensity-robust liver segmentation framework based on nnU-Netv2. CIRSeg combines 3D CutMix with stochastic intensity transfer using either Nyul augmentation or histogram matching to improve robustness to heterogeneous MRI intensities. Its cascaded architecture decouples low-resolution anatomical localization from full-resolution boundary refinement. At inference, source-free test-time adaptation based on confidence-filtered predictions and probability-prior regularization further improves robustness to out-of-distribution inputs. As a final deterministic post-processing step, largest connected component filtering removes isolated false-positive regions. On the CARE 2026 test set, CIRSeg achieves Dice scores of 97.13\% and 97.93\% on the in-domain and unseen-domain subsets, with corresponding HD95 values of 20.18 mm and 11.30 mm, respectively. These results demonstrate consistently accurate segmentation across both in-domain and unseen acquisition settings. The code is available at https://github.com/jingkunchen/MICCAI_CARE_2026

0.28

Multi-Resolution Feature Fusion U-Net for Magnetic Resonance Imaging Segmentation

cs.CV cs.LG ·2026-09-24 ·Eirini Cholopoulou, Dimitrios E. Diamantis, Dimitris K. Iakovidis
publishedbenchmark similarity 0.64
Abstract

The segmentation of anatomical structures in medical images and particularly in MRI scans, is essential for clinical diagnosis and monitoring disease progression. While Deep Learning (DL) architectures, such as U-Net and its extensions are very effective in medical image segmentation tasks, they often struggle with preserving fine-grained details and global contextual information. This is especially challenging for MRI data segmentation, where anatomical structures are characterized by irregular boundaries and variations in shape, contrast, and scale. To address this challenge, we propose a novel DL architecture for MRI segmentation across different anatomical structures. Specifically, the architecture introduces a module, named Multi-Resolution Feature Fusion (MRFF), that can be easily integrated into any U-Net-like architecture. The MRFF is integrated in all levels of an encode-decoder structure, along with attention mechanisms and skip connections to extract features at multiple resolutions, enabling the model to capture both fine-grained details and global contextual information. We evaluate the MRFFU-Net on two publicly available benchmark MRI datasets of different anatomical targets; one for Cerebrospinal Fluid (CSF) segmentation in spinal MR scans, and one for left atrium cardiac segmentation, from the Medical Segmentation Decathlon (MSD) challenge. Experimental results indicate that MRFFU-Net outperforms state-of-the-art models across multiple evaluation metrics, demonstrating its effectiveness in MRI segmentation.

0.44

Reduce, Then Encode: Multiscale Volumetric Reduction for 2D Foundation Models in Brain MRI

cs.CV ·2026-09-28 ·Dexuan Ding, Yuankai Qi, Bogong Wang, Luping Zhou, Amin Beheshti
similarity 0.63
Abstract

Pretrained 2D foundation models offer a practical alternative to dedicated 3D pretraining for brain structural magnetic resonance imaging (sMRI), but their use on volumetric data requires bridging the mismatch between a 2D encoder and a 3D volume input. Existing methods typically encode slices independently and integrate their features afterwards. We introduce Multiscale Volumetric Reduction (MVR), a reduce-then-encode approach that compresses each anatomical view from (D) slices into (M << D) complementary 2D components before foundation-model encoding. MVR combines an uncentered-PCA base component derived from the original through-plane intensities with residual detail components constructed from multiscale spatial descriptors. The reduction is estimated from the training volumes without diagnostic labels or gradient-based optimization and remains fixed thereafter. The resulting components are independently processed by a shared frozen 2D foundation model and concatenated for linear probing. Under this frozen-encoder setting, MVR achieves strong overall performance across ADNI, OASIS, and ABIDE relative to the evaluated 2D-to-3D adaptation methods and simple input-reduction baselines, while also generalizing strongly from ADNI to AIBL.

0.13

CMRVision: A Foundation Model for Cardiac MR Image Analysis

cs.CV ·2026-09-01 ·Athira J. Jacob, Puneet Sharma, Daniel Rueckert
publishedbenchmark similarity 0.63
Abstract · Accepted at MedAGI 2026 (peer-reviewed workshop at MICCAI 2026)

Cardiac magnetic resonance (CMR) imaging provides complementary information on cardiac anatomy, function, and tissue characterization across multiple sequences and views. In this work, we investigate foundation model pretraining for 2D CMR and introduce CMRVision, a CMR-specific foundation model trained using DINOv3-style self-supervised learning on a multi-center, multi-sequence cohort of 36 million CMR images. We systematically evaluate architectural and training design choices for domain-specific pretraining. CMRVision is evaluated on two downstream tasks: multi-task segmentation across cine, late gadolinium enhancement (LGE), and mapping sequences, and cine view classification. Our experiments show that CMR-specific pretraining, smaller patch sizes, and patch-level objectives consistently improve downstream performance. Across a multi-task segmentation benchmark, CMRVision achieved the strongest overall performance, outperforming prior natural-image (NI), medical-image, supervised, and CMR foundation model baselines. Improvements were modest but consistent across structures and sequences, with Dice scores ranging from 0.940-0.967 for LV and 0.855-0.905 for myocardium, and reaching 0.929 for RV, 0.920 for LA, and 0.931 for RA. The largest gains were observed for myocardium segmentation in LGE and mapping images. In a zero-shot segmentation task on unseen LGE long-axis views, the model achieved an average Dice score of 0.692, demonstrating cross-view generalization. For cine view classification, CMRVision achieved the highest average accuracy (0.906), compared to prior methods reported in the literature. These results highlight the potential of CMRVision to support robust and generalizable cardiac MRI analysis across multiple sequences and views.

0.28

AsymFeX: A Symmetry-Driven Framework for Ischemic Stroke Segmentation Across Imaging Modalities and Stroke Stages

eess.IV cs.CV ·2026-08-20 ·Maunil Shah, Vaanathi Sundaresan
code/data similarity 0.63
Abstract

Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning. Non-contrast CT (NCCT), the first-line imaging modality for diagnosing ischemic infarcts, exhibits subtle infarct contrast, making manual delineation slow and labor-intensive. Motivated by this, and by the clinical practice of comparing brain hemispheres to localize infarcts, we propose a two-stage, nnU-Net-compatible 3D segmentation method. The first stage corrects head tilt to align each scan to its true anatomical mid-sagittal plane; the second applies a novel Asymmetric Feature Extraction (AsymFeX) module, comparing each voxel to its true contralateral counterpart within a local 3 x 3 x 3 neighborhood via cross-hemispheric attention, feature disparity estimation, and dual-scale gating to capture both large and small infarcts. On AISD, our method achieves 0.6796 Dice, 23.53 mm HD95, and 7.69 mL AVD, significantly outperforming existing state-of-the-art methods, with clinically relevant volumetric analysis at the 70 mL thrombolysis-eligibility threshold. Proof-of-concept evaluation on ATLAS v2.1 and ISLES'24 demonstrates that the same symmetry-driven design generalizes across imaging modalities and stroke time points without architectural changes, further supported by an uncertainty analysis assessing reliability under clinical deployment. Code is publicly available at https://github.com/biomedia-lab/AIS-detection.

0.42

Improving Cross-Site Whole-Heart Segmentation

eess.IV cs.CV ·2026-08-25 ·Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao +2 more
publishedcode/data similarity 0.63
Abstract · 12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

0.51