CS Paper Radar

CMDiff: Left Atrial Scar Segmentation from 3D LGE MRI Using Conditional Mask Diffusion Model: A Feasibility Study

Jing Zhang, Bastien Bergere, Jonas Leite, Emilie Bollache, Mikaël Laredo, Alban Redheuil, Nadjia Kachenoura

cs.CV ·submitted 2026-11-05 10:53 UTC · v1
code/data

Abstract

Late gadolinium enhancement (LGE) cardiac MRI enables non-invasive assessment of left atrial (LA) scar, an imaging marker associated with atrial fibrillation ablation outcome. However, automatic scar segmentation is hindered by low contrast, the thin atrial wall, scarce labels, and extreme class imbalance. Conditional diffusion offers iterative mask generation, but its suitability for sparse 3D LA scar segmentation remains unclear. To address this gap, we propose Conditional Mask Diffusion (CMDiff), which predicts clean masks using a dynamic-encoder-conditioned 3D sinusoidal UNet. We compared CMDiff with a deterministic baseline on identical cases in five-fold cross-validation of 60 scar-labelled public LASCARQS subjects, with 48 training and 12 held-out cases per fold. CMDiff achieved a scar DSC of 0.47 $\pm$ 0.08, HD95 of 12.89 $\pm$ 6.39 mm, and ASD of 1.91 $\pm$ 0.96 mm, compared with deterministic baseline values of 0.51 $\pm$ 0.08, 10.86 $\pm$ 5.39 mm, and 1.58 $\pm$ 1.03 mm, respectively. Under the same implementation, clean-mask prediction performed substantially better than the noise-prediction configuration evaluated in this study. Thus, CMDiff was technically feasible but did not improve segmentation performance: DSC was lower, and both HD95 and ASD were higher. Direct mask diffusion therefore provides an analytical alternative, but not a competitive performance advance for this task. The source code is publicly available at https://github.com/jizhang02/CMDiff.

Comment
15 pages, 3 figures, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Multicentre Bi-atrial Segmentation from LGE-MRI for Atrial Fibrillation with a 2D and 3D Framework

eess.IV cs.CV ·2026-09-18 ·Malitha Gunawardhana, Gregory B. Sands, Mark L. Trew, Jichao Zhao
publishedbenchmark similarity 0.65
Abstract · Accepted at Biomedical Signal Processing and Control Journal

Accurate delineation of bi-atrial structures from late gadolinium enhancement MRI (LGE-MRI) is an important prerequisite for structural analysis and future fibrosis-quantification workflows in atrial fibrillation (AF). However, automated segmentation is challenging due to thin-walled anatomy, domain shifts across imaging centres, and limited benchmarking of existing methods. This study presents a two-stage segmentation framework and benchmarking platform for evaluating how ROI localisation, encoder design, 2D/3D dimensionality, and ensemble fusion affect bi-atrial wall and cavity segmentation across multicentre LGE-MRI datasets. The framework integrates 3D localisation and fine segmentation using 2D and 3D U-Net variants with ResNeXt encoders and compares them with convolutional, transformer-based, and state-space architectures. { Evaluation across three independent cohorts assessed accuracy and cross-domain transfer without target-domain fine-tuning. Cavity segmentation transferred more consistently across centres than atrial wall segmentation, while wall performance remained sensitive to domain shift, particularly in the Kobe cohort.} By quantifying how 2D, 3D, and ensemble architectures behave across centres and between walls and cavities, this work provides a reproducible benchmark for future methodological development and clinical validation.

0.36

MRI-Guided Reslice-Refined Cross-Slice SDF Reconstruction of the Left Ventricle from Cardiac MRI with Sparse Axial Supervision

cs.CV ·2026-09-08 ·Quanxin Zheng, Shuai Zhao
code/data similarity 0.63
Abstract

Reconstructing a three-dimensional left-ventricular (LV) endocardial surface from cardiac magnetic resonance (CMR) data is challenging when supervision is available on only a small number of axial slices. Through-plane geometry is weakly constrained, and automatically generated two-dimensional masks can propagate segmentation errors into the recovered shape. We present MR-RS-SDFR, a per-case implicit signed distance field (SDF) framework that reconstructs a continuous LV surface from a CMR volume and sparse axial weak masks. The method first builds a cross-slice SDF initialization from axial and longitudinal geometric cues and then refines the field using two complementary signals: MRI edge-field normal alignment, which provides an image-derived boundary cue independent of the weak masks, and differentiable reslice Dice and contour consistency, which preserve agreement with the observed planes. We evaluate three weak-mask generators -- LOO TransUNet, LOO nnU-Net, and an off-the-shelf Medical SAM3 model used without MM-WHS-specific training or fine-tuning -- and five sparsity levels from 4 to 64 axial planes. In the sparse-16 setting, final MR-RS-SDFR reconstruction reaches 0.928 Dice and 3.80mm HD95 with Medical SAM3 masks. The upstream generators do not exhibit a single common ranking across 2D and dense 3D segmentation, and nnU-Net- and Medical-SAM3-driven sparse reconstruction achieve the same mean final Dice despite different upstream error profiles. Across all three sparse-16 mask sources, MR-RS-SDFR is numerically better than protocol-matched full GHD+DVS in both Dice and HD95. Final Dice improves markedly from sparse-4 to sparse-16 and then saturates at the reported precision through sparse-64. These results support MRI-guided per-case SDF refinement as a reconstruction strategy that remains effective across weak-mask generators and supervision densities.

0.24

CMRVision: A Foundation Model for Cardiac MR Image Analysis

cs.CV ·2026-09-01 ·Athira J. Jacob, Puneet Sharma, Daniel Rueckert
publishedbenchmark similarity 0.60
Abstract · Accepted at MedAGI 2026 (peer-reviewed workshop at MICCAI 2026)

Cardiac magnetic resonance (CMR) imaging provides complementary information on cardiac anatomy, function, and tissue characterization across multiple sequences and views. In this work, we investigate foundation model pretraining for 2D CMR and introduce CMRVision, a CMR-specific foundation model trained using DINOv3-style self-supervised learning on a multi-center, multi-sequence cohort of 36 million CMR images. We systematically evaluate architectural and training design choices for domain-specific pretraining. CMRVision is evaluated on two downstream tasks: multi-task segmentation across cine, late gadolinium enhancement (LGE), and mapping sequences, and cine view classification. Our experiments show that CMR-specific pretraining, smaller patch sizes, and patch-level objectives consistently improve downstream performance. Across a multi-task segmentation benchmark, CMRVision achieved the strongest overall performance, outperforming prior natural-image (NI), medical-image, supervised, and CMR foundation model baselines. Improvements were modest but consistent across structures and sequences, with Dice scores ranging from 0.940-0.967 for LV and 0.855-0.905 for myocardium, and reaching 0.929 for RV, 0.920 for LA, and 0.931 for RA. The largest gains were observed for myocardium segmentation in LGE and mapping images. In a zero-shot segmentation task on unseen LGE long-axis views, the model achieved an average Dice score of 0.692, demonstrating cross-view generalization. For cine view classification, CMRVision achieved the highest average accuracy (0.906), compared to prior methods reported in the literature. These results highlight the potential of CMRVision to support robust and generalizable cardiac MRI analysis across multiple sequences and views.

0.28

Fiber-Resolved Microstructure Quantification from Multi-Shell Diffusion MRI using Detection Transformers

cs.CV cs.LGphysics.med-ph ·2026-09-30 ·Sebastian Endt, Marcus Wirth, Johannes Reinhold Schlund, Marion Irene Menzel
publishedbenchmarkcode/data similarity 0.59
Abstract · 12 pages, 4 figures, 1 table; Accepted at MICCAI 2026 Workshop CDMRI; Code: https://github.com/Marcus02W/Diffusion-DETR

Fiber orientation and compartmental microstructure are central to the characterization of white matter tissue in diffusion MRI, yet existing methods either resolve fiber orientations without quantifying microstructure, or quantify microstructure while assuming a fixed number of compartments and a single fiber direction. Nonparametric approaches that recover both require tensor-valued diffusion encoding and computationally expensive Monte-Carlo inversion of an ill-posed inverse Laplace transform. We propose to reframe this problem as an object detection-like task, adopting the Detection Transformer (DETR) architecture to jointly predict mean diffusivity (MD), fractional anisotropy (FA), main fiber direction, and signal fraction for a variable number of compartments per voxel from standard multi-shell diffusion MRI with linear encoding. Hungarian matching during training resolves permutation invariance across compartments. We introduce mean Average Precision as a reproducible benchmark metric. Evaluated on synthetic test data with up to five compartments per voxel, our model achieves $R^2=0.95$ for MD, $R^2=0.88$ for FA, and a median angular error of 4.2°, with performance scaling naturally with compartmental signal fraction.

0.65

Patch-Based Diffusion Reconstruction for Accelerated Cardiac Cine

eess.IV eess.SP ·2026-08-28 ·Xuan Lei, Philip Schniter, Juliet Varghese, Rizwan Ahmad
similarity 0.59
Abstract

Purpose: To develop and evaluate a diffusion-based reconstruction framework for highly accelerated 2D real-time (RT) cine cardiovascular magnetic resonance imaging (CMR). Methods: We trained an unconditional patch-based diffusion model and incorporated it into a reconstruction framework, termed CineDiff, using diffusion posterior sampling for data consistency. CineDiff was evaluated in four settings: (i) 30 retrospectively undersampled breath-held cine at 1.5T and 3T from healthy participants across multiple acceleration rates, (ii) 15 prospectively undersampled free-breathing RT cine at 1.5T and 3T from patients indicated for clinical CMR, and (iii) 10 prospectively undersampled mid-field (0.55T) free-breathing scans, including five from healthy subjects and five from porcine models. For retrospective undersampling, reconstruction quality was assessed using peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), learned perceptual image patch similarity (LPIPS), and deep image structure and texture similarity (DISTS). For prospective undersampling, image quality was evaluated by blinded expert scoring on a 5-point Likert scale. Results: In retrospectively undersampled breath-held cine data, CineDiff achieved higher PSNR and SSIM and lower LPIPS and DISTS than the comparison methods across all evaluated acceleration rates. In prospectively undersampled free-breathing RT cine data, CineDiff received higher expert image-quality scores. Qualitatively, CineDiff reduced block-like artifacts and preserved finer anatomical detail compared with traditional compressed sensing and a variational network method, termed CineVN. Conclusion: CineDiff enabled high-quality reconstruction of highly accelerated 2D RT cine CMR. The method also demonstrated robustness to out-of-distribution data, including mid-field and porcine acquisitions.

0.33

Anguinus Sculpturae: Compositional Synthesis of Peak-Enhancement Breast DCE-MRI Scans

cs.CV ·2026-09-27 ·Benjamin Hamm, Nico Albert Disch, Maximilian Rokuss, Yannick Kirchhoff, Constantin Ulrich +1 more
publishedcode/data similarity 0.59
Abstract · Accepted as an oral at the MAMA-SYNTH 2026 challenge / Deep-BreAth 2026 Workshop, MICCAI 2026. 12 pages, 3 figures, 1 table

Dynamic contrast-enhanced breast MRI (DCE-MRI) is rich in anatomical and perfusion information, but its reliance on gadolinium-based contrast agents raises safety concerns and adds cost. Virtual contrast enhancement, synthesizing post-contrast from pre-contrast images, is a promising alternative. We address the MAMA-SYNTH challenge task of predicting peak-enhancement breast MRI. Rather than adopting the full machinery of diffusion or flow matching, we observe that under a rectified, straight-line path the generative process collapses to a single difference prediction: the synthetic peak image is the pre-contrast image plus a predicted enhancement map, recovered in one forward pass. Around this we build Anguinus Sculpturae, a compositional pipeline in which nnU-Net segmentations of lesion, foreground and breast region guide two generators - one optimized for global fidelity, one for lesion structure through an asymmetric Tversky term routed via a frozen segmenter - composited region-wise with Gaussian-weighted blending. On the held-out Duke subset of MAMA-MIA our model achieves the best FRD and Dice among all evaluated variants, showing that single-step difference prediction with segmentation guidance suffices to recover both global fidelity and lesion structure. Code is available at https://github.com/MIC-DKFZ/AnguinusSculpturae.

0.31

Toward Vision Language Model-based Assessment of Clinical Quality and Usability of LGE-MR Images for Cardiac Ablation Planning

eess.IV cs.CV ·2026-08-21 ·Bipasha Kundu, Abhishek Chaturvedi, Axel W. E. Wismueller, Richard Simon, Cristian A. Linte
benchmark similarity 0.58
Abstract

LGE cardiac MRI is widely used for left atrial fibrosis assessment and ablation planning in atrial fibrillation patients as knowledge of fibrotic tissue regions identified from LGE-MRI is critical for catheter ablation. Often, poor quality images used during ablation planning can cause mis-localization of ablation targets, directly impacting procedure safety and outcome. The decision of whether a scan meets the minimum quality threshold for ablation planning is currently made informally by the reviewing radiologist and is not captured by any automated system, yet it is arguably the most safety-critical output of the image quality assessment (IQA) process. However, variations in image quality caused by noise, motion artifacts, and poor boundary definition significantly compromise the reliability of downstream segmentation and clinical decision-making tasks. Manual quality assessment by expert radiologists is subjective and difficult to scale, while existing automated methods produce scalar scores without interpretable clinical reasoning. In this work, we propose a two-stage vision language model (VLM) framework for clinically grounded image quality assessment of left atrial LGE-MRI. In the first stage, a fine-tuned VLM generates structured radiology-style quality reports predicting five radiologist-defined criteria: Noise, Motion Artifact, LA Boundary Accuracy, PV Region Accuracy, and Under-segmentation Severity. In the second stage, a GPT-based reasoning module maps the predicted quality and reports to a structured quality scores and binary clinical usability decision for ablation planning. We curate a dataset of 60 annotated image slice-text pairs from 20 patients and benchmark four state-of-the-art VLM architectures. InternVL2 achieves the highest criterion-level accuracy (Avg ACC=0.65, PLCC=0.79), while DeepSeek achieves perfect clinical usability agreement (Acc=1.00, kappa=1.00).

0.27

Volumetric Latent Diffusion for Brain Tumour Segmentation with Missing Modalities

eess.IV ·2026-11-05 ·Toan Nguyen Hai, Hung Nguyen Tuan, Ba Luong Son, Huynh Trinh Ngoc
similarity 0.58
Abstract

Brain tumour segmentation from magnetic resonance imaging normally assumes that all four imaging sequences are available, but in clinical practice one or more are frequently missing. Existing methods for incomplete inputs learn modality-invariant representations or distil from a full-modality teacher, and return a single deterministic mask. Gen- erative formulations instead model a distribution over plausible masks, but the cost of sampling at full resolution has largely confined them to two dimensions. This paper proposes a three-dimensional conditional latent diffusion framework for whole-tumour segmentation from incom- plete multi-sequence MRI. Images and annotations are first compressed by two volumetric autoencoders, which makes diffusion over whole vol- umes affordable, and sequences are dropped at random during training so that a single model handles every combination of missing sequences. Because the model samples rather than predicts, repeated draws also yield a voxel-wise map of disagreement at no extra training cost. Evalu- ations on 2,601 studies from BraTS 2023 and 2024 show that the method reaches 0.955 Dice with all four sequences and 0.904 with FLAIR alone, and that it is the most accurate of the four methods compared in eight of the fifteen configurations. The disagreement between draws widens as sequences are withheld, giving a signal that accompanies the prediction rather than replacing it

0.21