CS Paper Radar

Fiber-Resolved Microstructure Quantification from Multi-Shell Diffusion MRI using Detection Transformers

Sebastian Endt, Marcus Wirth, Johannes Reinhold Schlund, Marion Irene Menzel

cs.CV cs.LGphysics.med-ph ·submitted 2026-09-30 07:41 UTC · v1
publishedbenchmarkcode/data

Abstract

Fiber orientation and compartmental microstructure are central to the characterization of white matter tissue in diffusion MRI, yet existing methods either resolve fiber orientations without quantifying microstructure, or quantify microstructure while assuming a fixed number of compartments and a single fiber direction. Nonparametric approaches that recover both require tensor-valued diffusion encoding and computationally expensive Monte-Carlo inversion of an ill-posed inverse Laplace transform. We propose to reframe this problem as an object detection-like task, adopting the Detection Transformer (DETR) architecture to jointly predict mean diffusivity (MD), fractional anisotropy (FA), main fiber direction, and signal fraction for a variable number of compartments per voxel from standard multi-shell diffusion MRI with linear encoding. Hungarian matching during training resolves permutation invariance across compartments. We introduce mean Average Precision as a reproducible benchmark metric. Evaluated on synthetic test data with up to five compartments per voxel, our model achieves $R^2=0.95$ for MD, $R^2=0.88$ for FA, and a median angular error of 4.2°, with performance scaling naturally with compartmental signal fraction.

Comment
12 pages, 4 figures, 1 table; Accepted at MICCAI 2026 Workshop CDMRI; Code: https://github.com/Marcus02W/Diffusion-DETR

Closest papers

Nearest neighbours by meaning across the whole index.

Detection Instead of Inversion: T1-T2 Microstructure Quantification With Detection Transformers

cs.CV cs.LGphysics.med-ph ·2026-11-01 ·Sebastian Endt, Fatih Özkan, Marion I. Menzel
code/data similarity 0.77
Abstract · 4 pages, 3 figures, 1 table; For submission to IEEE ISBI 2027; Code: https://github.com/SebastianEndtTHI/t1t2-detr

T1-T2 correlation MRI has strong potential to quantify microstructural compartments without imposing a biological model. Traditionally, full T1-T2 spectra per voxel are reconstructed with an ill-conditioned and time-consuming Inverse Laplace Transform. We propose to view this challenge as an object detection task: A Detection Transformer (DETR) takes 64 TI/TE signals and directly predicts a set of compartments specified by T1, T2, and signal fraction. We achieve a mean average precision mAP@10 of 76.8% on simulated data, outperforming both our previous model design (53.8%) and regularized NNLS (66.1%). We show that our DETR approach outperforms NNLS in almost every setting across compartment count, compartmental signal fraction, and SNR. Reconstruction is orders of magnitude faster than NNLS. The results are fully reproducible from our public code: github.com/SebastianEndtTHI/t1t2-detr

0.29

Separating mixtures of single-fiber orientation distributions for increased sensitivity to crossing white matter fibers

eess.IV q-bio.QM ·2026-10-14 ·Adam M. Saunders, Gaurav Rudravaram, Michael E. Kim, Elyssa M. McMaster, Yifan Shuai +8 more
similarity 0.71
Abstract · 25 pages, 8 figures

Intro: Diffusion MRI allows for in vivo probing of brain tissue architecture via micron-level diffusion aggregated at the millimeter scale, but crossing white matter fibers decrease the sensitivity of downstream tasks such as microstructural modeling and tractography. Current fixel-based methods for identifying the number, orientation, and spread of fibers rely on finding the peaks of fiber orientation distributions from constrained spherical deconvolution. However, this method is biased by the spreads of nearby fibers and fails at angular separations lower than approximately 40-50 degrees. Methods: In this work, we perform a constrained nonlinear optimization called fiber segmentation by signal splitting and iterative least squares estimation (FISSILE), modeling each voxel as a mixture of single-fiber distributions. We use FISSILE to fit axially symmetric fibers in simulations and on three in vivo human subjects from the Human Connectome Project, an ex vivo raccoon brain, as well as the same human subject scanned twice at two different signal-to-noise ratios (SNRs). Results: On simulated data, FISSILE successfully identifies fibers at an angular separation of 40° and a volume fraction of 0.1 at an SNR as low as 30, while MRtrix3's fod2fixel is limited to 60° separation and 0.1 volume fraction at the same SNR. On acquired data, FISSILE identified 85.8% of white matter voxels on average in human brains and 79.4% in the raccoon with at least one fiber crossing, whereas fod2fixel identified 30.1% and 44.5%. The number of white matter fiber crossings was mildly sensitive to different noise levels in the human subject with two acquisitions. Conclusion: A method that models the crossing fiber phenomenon as an unmixing problem increases sensitivity to individual fibers for more precise characterization of anatomy.

0.18

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.71
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

Neural fields for adaptive white matter microstructural modeling

eess.IV ·2026-10-26 ·Adam M. Saunders, Gaurav Rudravaram, Elyssa M. McMaster, Michael E. Kim, Trent Schwartz +4 more
published similarity 0.70
Abstract · 12 pages, 7 figures. Accepted to SPIE Medical Imaging 2027: Image Processing

Diffusion magnetic resonance imaging (MRI) is sensitive to the micron-level diffusion motion of water molecules, allowing in vivo characterization of white matter architecture in the brain. Microstructural models like diffusion tensors or the Standard Model are typically fit independently on each voxel, limiting their ability to incorporate local spatial context and adapt to regional tissue complexity. Here, we introduce FiberField, an approach using neural fields that selects from multiple candidate models with different numbers of fibers to estimate fiber configurations and properties. This method incorporates spatial context through coordinate representations and model-weighted priors inspired by Bayesian model averaging to adapt to local microstructure. To compare FiberField with ground truth fiber properties, we validate on simulated diffusion MRI before applying to in vivo data. In simulated diffusion MRI, FiberField accurately estimates fiber directions and diffusivities using a multi-stick model (angular error: $2.2 \pm 2.8°$, diffusivity root mean square error (RMSE): $4.4 \times 10^{-4} \pm 5.2 \times 10^{-4}$ mm$^{2}$/s, fiber sensitivity: $0.87 \pm 0.21$). FiberField resolves fibers at 25% smaller angular separations than fod2fixel, and the diffusivity RMSE is 52% lower within fiber crossings than the Standard Model. On acquired diffusion MRI, FiberField's estimated fiber directions agree with those from MRtrix3's fod2fixel while also mapping microstructural properties such as diffusivity (angular difference: $10.5 \pm 7.1°$). Using neural fields allows for adaptive white matter modeling for selecting from a set of alternative models while maintaining accurate fiber property estimation.

0.36

Trusting the Inverse: Reliability-Aware Mapping for Simulation-Based Microstructure Estimation in Diffusion MRI

cs.CE ·2026-09-30 ·Juan Luis Villarreal Haro, Ileana Jelescu, Jean-Philippe Thiran, Jonathan Rafael-Patino
similarity 0.68
Abstract

Diffusion-weighted MRI can probe tissue microstructure non-invasively, however interpreting microstructural parameter estimates remains challenging due to the intrinsic ambiguity of the inverse problem. While simulation-based approaches can incorporate increasingly realistic tissue models, they still lack voxel-wise characterisation of the reliability and degeneracy of the inferred parameters. Here, we introduce a reliability framework for simulation-based microstructure estimation based on three complementary scores that identify distinct sources of unreliability in the estimation process: out-of-distribution signals, local signal mismatch, and parameter degeneracy. The framework was implemented using a Monte Carlo dictionary of 1,050 synthetic voxels generated from geometrically realistic substrates, with parameter ranges grounded in electron microscopy measurements of rat corpus callosum. The dictionary spans biologically plausible axon radii (0.25-0.85 $μ$m), microscopic angular spread (0-10$^\circ$), packing densities (60-92%), and intrinsic diffusivities (1.75-3.0 $μ$m$^2$/ms). On synthetic data, the resulting Reliability Index correlated with actual estimation error (Spearman $ρ= -0.742$) and distinguished between extrapolation, poor local interpolation, and parameter degeneracy. Applied to in vivo corpus callosum DW-MRI in rat (256 voxels, four animals) and human (MGH-USC HCP, 18,765 voxels, nine subjects), 91% and 73% of voxels respectively exceeded $R > 0.5$. These results demonstrate how reliability-aware analysis can support the interpretation and future development of simulation-based diffusion MRI microstructure models.

0.20

Prior-Guided Implicit Neural Representations for Single-Subject Diffusion MRI Super-Resolution

eess.IV cs.CV ·2026-09-01 ·Abdulkader Ghandoura, Marsil Zakour, William Consagra, Yogesh Rathi
publishedcode/data similarity 0.64
Abstract · Accepted at the British Machine Vision Conference (BMVC) 2026. 16 pages, 5 figures, 2 tables. Project page: https://abdulkaderghandoura.gith…

Resolving complex fiber geometries in brain white matter requires high-resolution diffusion MRI at the cost of long acquisition times. This leads many clinical protocols to opt for low-resolution scans, making downstream microstructure estimation and tractography challenging. Implicit neural representations (INRs) can model the diffusion signal continuously, enabling native single-subject super-resolution by querying the network at arbitrary spatial coordinates, yet existing methods often suffer from long training times and lack a mechanism to incorporate anatomical priors to regularize super-resolution by constraining the space of plausible reconstructions. To address these limitations, we propose a novel transfer-learning framework that pre-trains an INR on a high-resolution template and then adapts it to subject-specific scans via registration and fine-tuning. For $4\times$ through-plane super-resolution from 5 mm to 1.25 mm on Human Connectome Project (HCP) data, our method reduces NRMSE by 36-49% and increases FSIM by 24-43% over a recent baseline with $6\times$ faster training, outperforming competing INR-based methods across both image quality and domain-specific metrics. Code is available on the project page at https://abdulkaderghandoura.github.io/research/msc-thesis/ .

0.80

DeepPV-MRF: End-to-End Partial-Volume Fraction Estimation from MR Fingerprinting Time Series

eess.SP cs.AI ·2026-10-14 ·Tianyi Ding, Yang Gao, Zhuang Xiong, Feng Liu, Martijn A. Cloos +2 more
similarity 0.62
Abstract

Background: Estimating subvoxel tissue fractions from magnetic resonance fingerprinting (MRF) is challenging. Conventional dictionary matching and segmentation pipelines can propagate errors from intermediate parametric maps into tissue fraction estimates. Purpose: We introduce DeepPV-MRF, a deep learning framework that directly estimates voxel-wise tissue fractions from raw MRF signals. Methods: A cascaded spatial-temporal network was trained on subject-derived Bloch simulations with radial k-space undersampling. The network combines temporal encoding and spatial U-Net refinement to estimate cerebrospinal fluid (CSF), gray matter (GM), and white matter (WM) fractions without intermediate T1/T2 maps. We compared DeepPV-MRF with partial-volume dictionary matching (PV-DM) and pseudoinverse estimation (PV-Pinv) using simulated and in vivo data. Results: DeepPV-MRF outperformed both methods across acquisition settings. In single-shot simulations, CSF/WM/GM mean absolute errors were 0.0418/0.0744/0.0757, versus 0.1281/0.2443/0.2958 for PV-DM and 0.2021/0.2793/0.2630 for PV-Pinv. Corresponding structural similarity values were 0.960/0.916/0.922. In vivo results showed sharper anatomical boundaries and smoother tissue transitions, while cross-shot analysis indicated improved consistency across volunteers. Conclusions: DeepPV-MRF enables accurate and efficient direct tissue fraction estimation from MRF signals, particularly with limited shots. Further validation is needed before clinical deployment.

0.14

Uncertainty-Aware 3D Residual Wavelet Diffusion for Ultra Low-Field MRI Super-Resolution

cs.CV ·2026-09-21 ·Rui W. Yeow, Millie Beament, Fred Dick, Raha Razin, Martina Bocchetta +4 more
published similarity 0.62
Abstract · 11 pages, 3 figures, 1 table. Accepted at SASHIMI 2026 (MICCAI 2026 workshop). This is the version submitted for peer review

Ultra low-field MRI expands global access to neuroimaging but produces scans with low signal-to-noise ratio, reduced contrast, and thick slices. While regression-based super-resolution can recover anatomical detail for segmentation, it returns a single deterministic estimate that gives no indication of regions where the low-field input leaves anatomy underdetermined. Generative diffusion models offer an alternative by sampling the posterior distribution of plausible high-field images, quantifying this anatomical ambiguity. However, applying them to 3D whole-brain MRI is restricted by memory bottlenecks, slow sampling, and scanner domain shifts. We propose a 3D residual wavelet diffusion model that combines three ideas to overcome these hurdles. A lossless wavelet reparameterisation shrinks the spatial grid to fit a whole brain on a single GPU, residual shifting accelerates sampling by starting from the low-field input, and domain randomisation promotes scanner generalisation without paired training data. As the high-field reference is not a voxel-aligned ground truth, we evaluate downstream volumetric agreement. On a healthy cohort (n=19) imaged at 0.064T and 3T, our method matches a leading general-purpose regression approach in volumetric accuracy while additionally generating per-voxel uncertainty maps highlighting underdetermined regions. Furthermore, on a pilot dataset (n=11) of participants with cognitive impairment, disease-relevant atrophy is preserved rather than normalised towards a healthy prior. Our framework brings whole-brain posterior sampling to low-field super-resolution without sacrificing volumetric accuracy.

0.35