CS Paper Radar

DeepPV-MRF: End-to-End Partial-Volume Fraction Estimation from MR Fingerprinting Time Series

Tianyi Ding, Yang Gao, Zhuang Xiong, Feng Liu, Martijn A. Cloos, Jin Jin, Hongfu Sun

eess.SP cs.AI ·submitted 2026-10-14 09:51 UTC · v1

Abstract

Background: Estimating subvoxel tissue fractions from magnetic resonance fingerprinting (MRF) is challenging. Conventional dictionary matching and segmentation pipelines can propagate errors from intermediate parametric maps into tissue fraction estimates. Purpose: We introduce DeepPV-MRF, a deep learning framework that directly estimates voxel-wise tissue fractions from raw MRF signals. Methods: A cascaded spatial-temporal network was trained on subject-derived Bloch simulations with radial k-space undersampling. The network combines temporal encoding and spatial U-Net refinement to estimate cerebrospinal fluid (CSF), gray matter (GM), and white matter (WM) fractions without intermediate T1/T2 maps. We compared DeepPV-MRF with partial-volume dictionary matching (PV-DM) and pseudoinverse estimation (PV-Pinv) using simulated and in vivo data. Results: DeepPV-MRF outperformed both methods across acquisition settings. In single-shot simulations, CSF/WM/GM mean absolute errors were 0.0418/0.0744/0.0757, versus 0.1281/0.2443/0.2958 for PV-DM and 0.2021/0.2793/0.2630 for PV-Pinv. Corresponding structural similarity values were 0.960/0.916/0.922. In vivo results showed sharper anatomical boundaries and smoother tissue transitions, while cross-shot analysis indicated improved consistency across volunteers. Conclusions: DeepPV-MRF enables accurate and efficient direct tissue fraction estimation from MRF signals, particularly with limited shots. Further validation is needed before clinical deployment.

Closest papers

Nearest neighbours by meaning across the whole index.

Retrospective macromolecular pool fraction mapping from conventional clinical MRI: a physics-guided self-supervised deep learning framework

cs.CV physics.med-phcs.LG ·2026-10-27 ·Jelmer van Lune, Miha Fuderer, Oscar van der Heide, Matteo Maspero, Martin B. Schilder +3 more
similarity 0.66
Abstract · 38 pages, 24 figures

Macromolecular pool fraction (MPF) is a quantitative imaging biomarker sensitive to myelin integrity and other changes in tissue macromolecular content, but specialized acquisitions and reconstruction methods limit its use in large-scale studies. We present a physics-guided, self-supervised deep learning framework for retrospectively estimating MPF directly from conventional clinical brain MRI ($T_1$-weighted, $T_2$-weighted, and fluid-attenuated inversion recovery [FLAIR]) without paired quantitative reference scans. The framework embeds an analytical two-pool magnetization transfer signal model that related sequence-averaged radiofrequency transmit power to apparent longitudinal relaxation. To accommodate heterogeneous clinical protocols, the network conditions intermediate features on acquisition parameters via adaptive instance normalization. It was trained and evaluated on a multisite, multivendor, multiprotocol dataset of 7,705 MRI sessions (3 T). Across 1,237 test sessions, mean MPF was $0.182 \pm 0.007$ in white matter and $0.144 \pm 0.009$ in gray matter, with limited variation across vendor-by-protocol groups (between-group coefficient of variation: 2.65% and 5.63%, respectively). In 70 sessions with demyelinating-disease labels, MPF was 35.6% lower in segmented lesions than in normal-appearing white matter. MPF maps from two different clinical protocols acquired in a healthy volunteer showed a mean voxel-wise absolute percentage difference of 7.7% and a concordance correlation coefficient of $0.888$, indicating good cross-protocol consistency. These results suggest that magnetization transfer-informed self-supervised learning enables stable MPF mapping from conventional clinical MRI, providing a scalable approach to investigate demyelinating pathology in both existing imaging archives and prospectively acquired conventional clinical scans without dedicated qMT acquisitions.

0.28

Multi-Resolution Feature Fusion U-Net for Magnetic Resonance Imaging Segmentation

cs.CV cs.LG ·2026-09-24 ·Eirini Cholopoulou, Dimitrios E. Diamantis, Dimitris K. Iakovidis
publishedbenchmark similarity 0.64
Abstract

The segmentation of anatomical structures in medical images and particularly in MRI scans, is essential for clinical diagnosis and monitoring disease progression. While Deep Learning (DL) architectures, such as U-Net and its extensions are very effective in medical image segmentation tasks, they often struggle with preserving fine-grained details and global contextual information. This is especially challenging for MRI data segmentation, where anatomical structures are characterized by irregular boundaries and variations in shape, contrast, and scale. To address this challenge, we propose a novel DL architecture for MRI segmentation across different anatomical structures. Specifically, the architecture introduces a module, named Multi-Resolution Feature Fusion (MRFF), that can be easily integrated into any U-Net-like architecture. The MRFF is integrated in all levels of an encode-decoder structure, along with attention mechanisms and skip connections to extract features at multiple resolutions, enabling the model to capture both fine-grained details and global contextual information. We evaluate the MRFFU-Net on two publicly available benchmark MRI datasets of different anatomical targets; one for Cerebrospinal Fluid (CSF) segmentation in spinal MR scans, and one for left atrium cardiac segmentation, from the Medical Segmentation Decathlon (MSD) challenge. Experimental results indicate that MRFFU-Net outperforms state-of-the-art models across multiple evaluation metrics, demonstrating its effectiveness in MRI segmentation.

0.45

dMRI-F: A Foundation Model for Generalizable Diffusion MRI Analysis from Sparse Acquisitions

cs.CV ·2026-10-13 ·Xi Zhu, Yijie Li, Xiaofan Wang, Wei Zhang, Huafu Chen +2 more
similarity 0.64
Abstract

Diffusion MRI (dMRI) probes water diffusion within the brain, providing unique information about tissue microstructure and white matter connectivity. High-quality dMRI enables advanced and accurate analyses but demands dense acquisitions, resulting in long scan times and hardware constraints that are often infeasible. Further, dMRI requires dedicated computational methods to support diverse analysis tasks (e.g., parcellation, registration, and synthesis) for both neuroscientific and clinical applications. Here, we present dMRI-F, a foundation model that unifies dMRI data enhancement and downstream tasks across diverse acquisitions and populations, while requiring only minimal acquisition input. dMRI-F is pre-trained with a q-space masked reconstruction task: predicting densely sampled multi-shell data from only six volumes. It learns generalizable latent feature representations of dMRI data, which serve as a core foundation for adapting to diverse downstream tasks, including brain parcellation, brain registration, and cross-modal synthesis. Across nine independently acquired datasets, we demonstrate that dMRI-F outperforms state-of-the-art methods with robust generalization across acquisitions, populations, and tasks. Our results demonstrate dMRI-F's versatility as a general-purpose framework that enables diverse dMRI applications from low-cost, sparse acquisitions.

0.15

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.63
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

Fiber-Resolved Microstructure Quantification from Multi-Shell Diffusion MRI using Detection Transformers

cs.CV cs.LGphysics.med-ph ·2026-09-30 ·Sebastian Endt, Marcus Wirth, Johannes Reinhold Schlund, Marion Irene Menzel
publishedbenchmarkcode/data similarity 0.62
Abstract · 12 pages, 4 figures, 1 table; Accepted at MICCAI 2026 Workshop CDMRI; Code: https://github.com/Marcus02W/Diffusion-DETR

Fiber orientation and compartmental microstructure are central to the characterization of white matter tissue in diffusion MRI, yet existing methods either resolve fiber orientations without quantifying microstructure, or quantify microstructure while assuming a fixed number of compartments and a single fiber direction. Nonparametric approaches that recover both require tensor-valued diffusion encoding and computationally expensive Monte-Carlo inversion of an ill-posed inverse Laplace transform. We propose to reframe this problem as an object detection-like task, adopting the Detection Transformer (DETR) architecture to jointly predict mean diffusivity (MD), fractional anisotropy (FA), main fiber direction, and signal fraction for a variable number of compartments per voxel from standard multi-shell diffusion MRI with linear encoding. Hungarian matching during training resolves permutation invariance across compartments. We introduce mean Average Precision as a reproducible benchmark metric. Evaluated on synthetic test data with up to five compartments per voxel, our model achieves $R^2=0.95$ for MD, $R^2=0.88$ for FA, and a median angular error of 4.2°, with performance scaling naturally with compartmental signal fraction.

0.66

Comparative Study of Anatomical and Learned Features in AI Models for Structural Brain MRI

cs.CV cs.AI ·2026-09-06 ·Boyang Yu, Miquel Lopez Escoriza, Long Chen, Arjun V. Masurkar, Narges Razavian +1 more
published similarity 0.62
Abstract

In this work, we comprehensively evaluate three popular feature-extraction paradigms in AI-based neuroimaging modeling: (1) computation of anatomical surfaces and volumes, (2) supervised learning with convolutional neural networks (CNNs), and (3) unsupervised pretraining of vision transformer (ViT) foundation models, followed by supervised finetuning. Our study is based on 18 publicly available datasets containing 3D structural T1-weighted MRI scans from approximately 80,000 participants across seven distinct clinical tasks. We observe that a linear model based on anatomical features matches the diagnostic performance of complex nonlinear features learned by sophisticated AI frameworks, including foundation models trained on thousands of scans. Conversely, CNNs and pretrained ViTs learn features that implicitly capture relevant anatomical information, bypassing the need for explicit feature extraction. Building upon these insights, we propose Anatomy Segmentation Pretraining (ASP), a novel method to incorporate anatomical information during foundation-model pretraining, which outperforms existing models in biological age estimation.

0.31

Deep Learning Segmentation of Diffusion-Weighted MRI Acute Ischaemic Stroke: A Pragmatic Evaluation Across Three Datasets

cs.CV ·2026-08-26 ·Atle Bjørnerud, Till Schellhorn, Thor H. Skattør, Terje Nome, Jon André Ottesen +2 more
similarity 0.61
Abstract · 19 pages, 8 figure and 4 tables

Objective: Diffusion-weighted MRI (DWI-MRI) is the gold standard for visualizing and quantifying acute ischaemic stroke (AIS). Although deep learning methods can accurately segment AIS lesions, the optimal image inputs and model architecture remain uncertain. We evaluated whether accurate AIS lesion segmentation can be achieved using a pragmatic deep learning approach with minimal preprocessing and clinically feasible inference times. Materials and Methods: Self-configured nnU-Net models were trained on 1,744 DWI cases from local, national, and open-access datasets and tested on 436 cases. Four experimental conditions were evaluated using five-fold cross-validation: with or without brain extraction and using either DWI alone or DWI plus apparent diffusion coefficient (ADC) images as inputs. Two architectures were compared: the baseline nnU-Net (base) and a residual encoder nnU-Net (ResEnc). Performance was benchmarked against the DeepISLES ensemble model from the 2022 ISLES challenge. Results: In the test set (n=436), the base model achieved a median (IQR) Dice similarity coefficient (DSC) of 0.84 (0.19). For the base model, only two of six pairwise comparisons between input configurations showed significant differences. ResEnc produced small but significant improvements in DSC compared with the base model for DWI, DWI+brain extraction, and DWI+ADC inputs (all p<0.02), but not for DWI+ADC+brain extraction (p>0.50). The base model significantly outperformed DeepISLES, particularly in patients with smaller infarct volumes (signed-rank test, p<0.01). Conclusions: A baseline nnU-Net trained on DWI alone, without preprocessing, enabled fast and accurate AIS lesion segmentation. This streamlined approach may facilitate clinical research and support acute stroke imaging workflows

0.22

Uncertainty-Aware 3D Residual Wavelet Diffusion for Ultra Low-Field MRI Super-Resolution

cs.CV ·2026-09-21 ·Rui W. Yeow, Millie Beament, Fred Dick, Raha Razin, Martina Bocchetta +4 more
published similarity 0.61
Abstract · 11 pages, 3 figures, 1 table. Accepted at SASHIMI 2026 (MICCAI 2026 workshop). This is the version submitted for peer review

Ultra low-field MRI expands global access to neuroimaging but produces scans with low signal-to-noise ratio, reduced contrast, and thick slices. While regression-based super-resolution can recover anatomical detail for segmentation, it returns a single deterministic estimate that gives no indication of regions where the low-field input leaves anatomy underdetermined. Generative diffusion models offer an alternative by sampling the posterior distribution of plausible high-field images, quantifying this anatomical ambiguity. However, applying them to 3D whole-brain MRI is restricted by memory bottlenecks, slow sampling, and scanner domain shifts. We propose a 3D residual wavelet diffusion model that combines three ideas to overcome these hurdles. A lossless wavelet reparameterisation shrinks the spatial grid to fit a whole brain on a single GPU, residual shifting accelerates sampling by starting from the low-field input, and domain randomisation promotes scanner generalisation without paired training data. As the high-field reference is not a voxel-aligned ground truth, we evaluate downstream volumetric agreement. On a healthy cohort (n=19) imaged at 0.064T and 3T, our method matches a leading general-purpose regression approach in volumetric accuracy while additionally generating per-voxel uncertainty maps highlighting underdetermined regions. Furthermore, on a pilot dataset (n=11) of participants with cognitive impairment, disease-relevant atrophy is preserved rather than normalised towards a healthy prior. Our framework brings whole-brain posterior sampling to low-field super-resolution without sacrificing volumetric accuracy.

0.35