CS Paper Radar

Trusting the Inverse: Reliability-Aware Mapping for Simulation-Based Microstructure Estimation in Diffusion MRI

Juan Luis Villarreal Haro, Ileana Jelescu, Jean-Philippe Thiran, Jonathan Rafael-Patino

cs.CE ·submitted 2026-09-30 04:07 UTC · v1

Abstract

Diffusion-weighted MRI can probe tissue microstructure non-invasively, however interpreting microstructural parameter estimates remains challenging due to the intrinsic ambiguity of the inverse problem. While simulation-based approaches can incorporate increasingly realistic tissue models, they still lack voxel-wise characterisation of the reliability and degeneracy of the inferred parameters. Here, we introduce a reliability framework for simulation-based microstructure estimation based on three complementary scores that identify distinct sources of unreliability in the estimation process: out-of-distribution signals, local signal mismatch, and parameter degeneracy. The framework was implemented using a Monte Carlo dictionary of 1,050 synthetic voxels generated from geometrically realistic substrates, with parameter ranges grounded in electron microscopy measurements of rat corpus callosum. The dictionary spans biologically plausible axon radii (0.25-0.85 $μ$m), microscopic angular spread (0-10$^\circ$), packing densities (60-92%), and intrinsic diffusivities (1.75-3.0 $μ$m$^2$/ms). On synthetic data, the resulting Reliability Index correlated with actual estimation error (Spearman $ρ= -0.742$) and distinguished between extrapolation, poor local interpolation, and parameter degeneracy. Applied to in vivo corpus callosum DW-MRI in rat (256 voxels, four animals) and human (MGH-USC HCP, 18,765 voxels, nine subjects), 91% and 73% of voxels respectively exceeded $R > 0.5$. These results demonstrate how reliability-aware analysis can support the interpretation and future development of simulation-based diffusion MRI microstructure models.

Closest papers

Nearest neighbours by meaning across the whole index.

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.74
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

Evaluating and Calibrating Diffusion Model-derived Uncertainty for Quantitative MRI Mapping

cs.CV ·2026-08-12 ·Shishuai Wang, Stefan Klein, Juan A. Hernandez-Tamames, Dirk H. J. Poot
published similarity 0.73
Abstract · 11 pages, 6 figures. Accepted at the MICCAI 2026 Workshop on Uncertainty for Safe Utilization of Machine Learning in Medical Imaging (UNSURE…

Quantitative MRI (qMRI) provides standardised tissue parameter maps, but the reliability of deep learning-based qMRI mapping methods is often not explicitly characterised. In this work we systematically evaluate uncertainty maps for quantitative MRI derived from multiple inferences of a data-consistent diffusion model-based qMRI framework. Evaluation on synthetic test data assessed error-awareness, high-error detection, selective prediction, and Gaussian interval calibration. Diffusion model-derived uncertainty was positively associated with the mapping error, while risk-coverage analysis showed that excluding high-uncertainty voxels reduced the retained error. However, the raw uncertainty was poorly calibrated for quantitative interval interpretation. Calibration was substantially improved using a post-hoc procedure combining prediction-value-dependent bias correction with scalar uncertainty scaling. Qualitative evaluation on a healthy volunteer showed spatially meaningful uncertainty patterns. These results indicate that diffusion model-derived uncertainty is informative for reliability assessment and selective prediction, but requires calibration for quantitative interval interpretation.

0.61

Fiber-Resolved Microstructure Quantification from Multi-Shell Diffusion MRI using Detection Transformers

cs.CV cs.LGphysics.med-ph ·2026-09-30 ·Sebastian Endt, Marcus Wirth, Johannes Reinhold Schlund, Marion Irene Menzel
publishedbenchmarkcode/data similarity 0.68
Abstract · 12 pages, 4 figures, 1 table; Accepted at MICCAI 2026 Workshop CDMRI; Code: https://github.com/Marcus02W/Diffusion-DETR

Fiber orientation and compartmental microstructure are central to the characterization of white matter tissue in diffusion MRI, yet existing methods either resolve fiber orientations without quantifying microstructure, or quantify microstructure while assuming a fixed number of compartments and a single fiber direction. Nonparametric approaches that recover both require tensor-valued diffusion encoding and computationally expensive Monte-Carlo inversion of an ill-posed inverse Laplace transform. We propose to reframe this problem as an object detection-like task, adopting the Detection Transformer (DETR) architecture to jointly predict mean diffusivity (MD), fractional anisotropy (FA), main fiber direction, and signal fraction for a variable number of compartments per voxel from standard multi-shell diffusion MRI with linear encoding. Hungarian matching during training resolves permutation invariance across compartments. We introduce mean Average Precision as a reproducible benchmark metric. Evaluated on synthetic test data with up to five compartments per voxel, our model achieves $R^2=0.95$ for MD, $R^2=0.88$ for FA, and a median angular error of 4.2°, with performance scaling naturally with compartmental signal fraction.

0.65

Diffusion MRI protocol design for reliable parameter recovery: a unified framework across biophysical models

eess.SP physics.med-ph ·2026-10-20 ·Ekin Taskin, Jonathan Rafael-Patiño, Erick Jorge Canales-Rodríguez, Jean-Philippe Thiran
similarity 0.67
Abstract

Reliable microstructural parameter estimation in diffusion MRI (dMRI) critically depends on the acquisition protocol. Yet, common protocol design criteria may not fully reflect estimator bias, parameter constraints, and nonlinear fitting behavior in complex inverse problems. Here, we introduce Protocol Optimization via Loss Assessing Parameter Recovery (POLAR), an end-to-end framework that searches the continuous acquisition space and directly minimizes multiparameter recovery error through noisy signal simulation and the chosen model fitting. We demonstrate POLAR spanning distinct microstructural environments: the Cylinder-Zeppelin model for white matter, Neurite Exchange Imaging (NEXI) for gray matter, and Cellular Exchange Imaging (CEXI) for permeable cells. Across independent held-out parameter sets, POLAR consistently outperformed model-specific reference designs, reducing RMSE by up to $50\%$ for Cylinder-Zeppelin and $74\%$ for CEXI, while reducing NEXI exchange time bias by $70\%$. These gains across distinct biophysical models, acquisition settings, and reference design strategies demonstrate the benefit of optimizing acquisition protocols through the downstream parameter-estimation problem. POLAR provides a flexible, model-specific and estimator-aware framework for designing dMRI protocols tailored to the microstructural parameters and experimental conditions of interest.

0.28

Neural fields for adaptive white matter microstructural modeling

eess.IV ·2026-10-26 ·Adam M. Saunders, Gaurav Rudravaram, Elyssa M. McMaster, Michael E. Kim, Trent Schwartz +4 more
published similarity 0.62
Abstract · 12 pages, 7 figures. Accepted to SPIE Medical Imaging 2027: Image Processing

Diffusion magnetic resonance imaging (MRI) is sensitive to the micron-level diffusion motion of water molecules, allowing in vivo characterization of white matter architecture in the brain. Microstructural models like diffusion tensors or the Standard Model are typically fit independently on each voxel, limiting their ability to incorporate local spatial context and adapt to regional tissue complexity. Here, we introduce FiberField, an approach using neural fields that selects from multiple candidate models with different numbers of fibers to estimate fiber configurations and properties. This method incorporates spatial context through coordinate representations and model-weighted priors inspired by Bayesian model averaging to adapt to local microstructure. To compare FiberField with ground truth fiber properties, we validate on simulated diffusion MRI before applying to in vivo data. In simulated diffusion MRI, FiberField accurately estimates fiber directions and diffusivities using a multi-stick model (angular error: $2.2 \pm 2.8°$, diffusivity root mean square error (RMSE): $4.4 \times 10^{-4} \pm 5.2 \times 10^{-4}$ mm$^{2}$/s, fiber sensitivity: $0.87 \pm 0.21$). FiberField resolves fibers at 25% smaller angular separations than fod2fixel, and the diffusivity RMSE is 52% lower within fiber crossings than the Standard Model. On acquired diffusion MRI, FiberField's estimated fiber directions agree with those from MRtrix3's fod2fixel while also mapping microstructural properties such as diffusivity (angular difference: $10.5 \pm 7.1°$). Using neural fields allows for adaptive white matter modeling for selecting from a set of alternative models while maintaining accurate fiber property estimation.

0.36

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.61
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36

Midsagittal Corpus Callosum Parameterization: A Framework for Spatially Detailed Diffusion MR Imaging Analysis

eess.IV q-bio.NCq-bio.QM ·2026-11-14 ·Caio Santana, Catherine Lebel, Richard Frayne, Letícia Rittner
similarity 0.60
Abstract · 47 pages, 10 figures, 6 tables, plus 11 pages of supplementary material (12 figures, 6 tables). Under review at Imaging Neuroscience

The corpus callosum (CC) is the largest white matter structure in the human brain and plays a central role in interhemispheric communication. Diffusion MR imaging is widely used to investigate microstructural organization, but commonly used analysis approaches have important limitations. Voxel-based methods rely heavily on accurate inter-subject registration and smoothing choices, tract-based spatial statistics (TBSS) restricts the analysis to a narrow white matter skeleton, and parcellation approaches reduce spatial detail by averaging diffusion measures over relatively large regions. In this work, we introduce a parameterization framework for the analysis of the midsagittal CC that resamples the structure using a standardized grid of points, establishing a geometric correspondence across individuals without explicit inter-subject registration. In a test-retest dataset, the method provided stable measurements while covering most of the midsagittal CC, and sensitivity analyses showed that results in the central CC changed little under perturbations of the input CC mask, whereas peripheral regions were more sensitive. The framework was further evaluated in group analyses of aging and Alzheimer's disease in datasets that differ in acquisition protocol and spatial resolution. Effect-size maps and quantitative comparisons showed that its results were largely consistent with TBSS and parcellation-based analyses in the overall spatial pattern of effects, while also revealing additional spatially localized differences. These findings suggest that the parameterization provides a simple, computationally efficient, and spatially detailed approach for investigating midsagittal CC microstructure, offering a structure-specific complement to whole-brain and region-based methods.

0.18

Image-Conditioned Diffusion Models for Quality Assurance of Organ-at-Risk Segmentations in Radiotherapy

cs.CV ·2026-08-24 ·Clea Dronne, Catharine H Clark, Xavier Loizeau, Elizabeth Miles, Peter Hoskin +1 more
hot direction similarity 0.59
Abstract · Submitted to the MICCAI 2026 UNSURE Workshop

Accurate organ-at-risk segmentation is essential for radiotherapy planning, but reviewing segmentations is time-consuming and subjective. We investigate normative modelling for segmentation error detection in head-and-neck CT, comparing a VAE framework with an image-conditioned segmentation diffusion model. Models were evaluated on RADCURE brainstem and spinal cord segmentations using simulated boundary and width perturbations. Error detection was assessed using the Dice similarity coefficient and the Distance to Agreement (DTA) between the input and reconstructed segmentations. While both models detected some simulated errors, regional DTA showed that the diffusion model localised subtle boundary errors more consistently. These results support image-conditioned diffusion reconstruction as a promising framework for localised, anatomy-aware segmentation QA.

0.36