CS Paper Radar

Diffusion MRI protocol design for reliable parameter recovery: a unified framework across biophysical models

Ekin Taskin, Jonathan Rafael-Patiño, Erick Jorge Canales-Rodríguez, Jean-Philippe Thiran

eess.SP physics.med-ph ·submitted 2026-10-20 12:13 UTC · v1

Abstract

Reliable microstructural parameter estimation in diffusion MRI (dMRI) critically depends on the acquisition protocol. Yet, common protocol design criteria may not fully reflect estimator bias, parameter constraints, and nonlinear fitting behavior in complex inverse problems. Here, we introduce Protocol Optimization via Loss Assessing Parameter Recovery (POLAR), an end-to-end framework that searches the continuous acquisition space and directly minimizes multiparameter recovery error through noisy signal simulation and the chosen model fitting. We demonstrate POLAR spanning distinct microstructural environments: the Cylinder-Zeppelin model for white matter, Neurite Exchange Imaging (NEXI) for gray matter, and Cellular Exchange Imaging (CEXI) for permeable cells. Across independent held-out parameter sets, POLAR consistently outperformed model-specific reference designs, reducing RMSE by up to $50\%$ for Cylinder-Zeppelin and $74\%$ for CEXI, while reducing NEXI exchange time bias by $70\%$. These gains across distinct biophysical models, acquisition settings, and reference design strategies demonstrate the benefit of optimizing acquisition protocols through the downstream parameter-estimation problem. POLAR provides a flexible, model-specific and estimator-aware framework for designing dMRI protocols tailored to the microstructural parameters and experimental conditions of interest.

Closest papers

Nearest neighbours by meaning across the whole index.

Trusting the Inverse: Reliability-Aware Mapping for Simulation-Based Microstructure Estimation in Diffusion MRI

cs.CE ·2026-09-30 ·Juan Luis Villarreal Haro, Ileana Jelescu, Jean-Philippe Thiran, Jonathan Rafael-Patino
similarity 0.67
Abstract

Diffusion-weighted MRI can probe tissue microstructure non-invasively, however interpreting microstructural parameter estimates remains challenging due to the intrinsic ambiguity of the inverse problem. While simulation-based approaches can incorporate increasingly realistic tissue models, they still lack voxel-wise characterisation of the reliability and degeneracy of the inferred parameters. Here, we introduce a reliability framework for simulation-based microstructure estimation based on three complementary scores that identify distinct sources of unreliability in the estimation process: out-of-distribution signals, local signal mismatch, and parameter degeneracy. The framework was implemented using a Monte Carlo dictionary of 1,050 synthetic voxels generated from geometrically realistic substrates, with parameter ranges grounded in electron microscopy measurements of rat corpus callosum. The dictionary spans biologically plausible axon radii (0.25-0.85 $μ$m), microscopic angular spread (0-10$^\circ$), packing densities (60-92%), and intrinsic diffusivities (1.75-3.0 $μ$m$^2$/ms). On synthetic data, the resulting Reliability Index correlated with actual estimation error (Spearman $ρ= -0.742$) and distinguished between extrapolation, poor local interpolation, and parameter degeneracy. Applied to in vivo corpus callosum DW-MRI in rat (256 voxels, four animals) and human (MGH-USC HCP, 18,765 voxels, nine subjects), 91% and 73% of voxels respectively exceeded $R > 0.5$. These results demonstrate how reliability-aware analysis can support the interpretation and future development of simulation-based diffusion MRI microstructure models.

0.20

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.65
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.62
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization

eess.IV ·2026-11-03 ·Rushdi Rusho, Jyothi Rikhab Chand, Steve R. Kecskemeti, James H. Holmes, Mathews Jacob
similarity 0.62
Abstract · 5 pages, 3 figures

Quantitative MRI methods can offer tissue parameter maps (e.g. T1) that are comparable across scanners, sessions and subjects, together with multiple contrast-weighted images from a single scan. However, most data are acquired at 1 mm, which limits their use in neurodegenerative diseases that affect fine brain structures. We introduce, to our knowledge, the first diffusion-model-based reconstruction for quantitative MRI at 0.5 mm isotropic resolution from scans of less than 5 minutes, which has eightfold smaller voxel volume than clinical protocols. The key idea is to apply the prior to the synthesized contrast images rather than to the subspace coefficients. The prior is then independent of the temporal basis and the sequence, which improves generalization and allows a 2-D multiscale energy (MuSE) model trained on grayscale CelebA face images to be used without any MRI training data. The explicit energy makes reconstruction MAP estimation by a step-size-free majorize-minimize algorithm that regularizes a rotating subset of contrasts along different axes, which makes 3-D multi-contrast reconstruction tractable. For 3-D radial MPnRAGE at 7 T in 4.3 min, MuSE reduced the phantom NRMSE from 0.133 (CG-SENSE) and 0.091 (L1-wavelet) to 0.074 and the WM T1 interquartile range from 117 and 47 ms to 38 ms, and it was demonstrated in vivo at 7 T.

0.24

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-20 ·Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya
code/data similarity 0.61
Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

0.31

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.61
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24

A Posterior-Dynamics Framework for Imaging Inverse Problems with Pretrained Diffusion Priors

cs.AI stat.MLcs.LG ·2026-08-15 ·Zhaoqiang Liu, Tongyao Pang, Ruibing Wang, Yang Zheng
theory similarity 0.61
Abstract · 26 pages, 5 figures, 3 tables

Pretrained diffusion models represent image distributions through a continuum of progressively smoothed distributions. This multiscale structure organizes generation from global structure to fine detail and supports high-quality, diverse samples. We exploit the same multiscale diffusion prior for linear imaging inverse problems. Rather than using the pretrained model only as a denoiser in an outer iteration, we define a surrogate likelihood whose center is aligned with the clean-image coordinate and whose covariance accounts for residual diffusion uncertainty. This construction defines an explicit surrogate posterior path, from which we derive continuous posterior dynamics. A tunable Langevin component supports target tracking and allows the amount of posterior exploration to be adapted to the application. We prove endpoint consistency and a finite-horizon tracking bound and, in the exact-score setting, first-order weak accuracy. For computation, we derive the Posterior-Dynamics Implicit--Explicit sampler (PD-IMEX), a stable method using one score evaluation per diffusion scale and an implicit data-consistency update. Experiments on deblurring, super-resolution, and inpainting show strong reconstruction quality at 100 score evaluations, coarse-grid stability, and controllable fidelity--diversity behavior.

0.40

Fiber-Resolved Microstructure Quantification from Multi-Shell Diffusion MRI using Detection Transformers

cs.CV cs.LGphysics.med-ph ·2026-09-30 ·Sebastian Endt, Marcus Wirth, Johannes Reinhold Schlund, Marion Irene Menzel
publishedbenchmarkcode/data similarity 0.60
Abstract · 12 pages, 4 figures, 1 table; Accepted at MICCAI 2026 Workshop CDMRI; Code: https://github.com/Marcus02W/Diffusion-DETR

Fiber orientation and compartmental microstructure are central to the characterization of white matter tissue in diffusion MRI, yet existing methods either resolve fiber orientations without quantifying microstructure, or quantify microstructure while assuming a fixed number of compartments and a single fiber direction. Nonparametric approaches that recover both require tensor-valued diffusion encoding and computationally expensive Monte-Carlo inversion of an ill-posed inverse Laplace transform. We propose to reframe this problem as an object detection-like task, adopting the Detection Transformer (DETR) architecture to jointly predict mean diffusivity (MD), fractional anisotropy (FA), main fiber direction, and signal fraction for a variable number of compartments per voxel from standard multi-shell diffusion MRI with linear encoding. Hungarian matching during training resolves permutation invariance across compartments. We introduce mean Average Precision as a reproducible benchmark metric. Evaluated on synthetic test data with up to five compartments per voxel, our model achieves $R^2=0.95$ for MD, $R^2=0.88$ for FA, and a median angular error of 4.2°, with performance scaling naturally with compartmental signal fraction.

0.65