CS Paper Radar

Neural fields for adaptive white matter microstructural modeling

Adam M. Saunders, Gaurav Rudravaram, Elyssa M. McMaster, Michael E. Kim, Trent Schwartz, Yimeng Dou, Lianrui Zuo, Adam W. Anderson, Bennett A. Landman

eess.IV ·submitted 2026-10-26 20:12 UTC · v1
published

Abstract

Diffusion magnetic resonance imaging (MRI) is sensitive to the micron-level diffusion motion of water molecules, allowing in vivo characterization of white matter architecture in the brain. Microstructural models like diffusion tensors or the Standard Model are typically fit independently on each voxel, limiting their ability to incorporate local spatial context and adapt to regional tissue complexity. Here, we introduce FiberField, an approach using neural fields that selects from multiple candidate models with different numbers of fibers to estimate fiber configurations and properties. This method incorporates spatial context through coordinate representations and model-weighted priors inspired by Bayesian model averaging to adapt to local microstructure. To compare FiberField with ground truth fiber properties, we validate on simulated diffusion MRI before applying to in vivo data. In simulated diffusion MRI, FiberField accurately estimates fiber directions and diffusivities using a multi-stick model (angular error: $2.2 \pm 2.8°$, diffusivity root mean square error (RMSE): $4.4 \times 10^{-4} \pm 5.2 \times 10^{-4}$ mm$^{2}$/s, fiber sensitivity: $0.87 \pm 0.21$). FiberField resolves fibers at 25% smaller angular separations than fod2fixel, and the diffusivity RMSE is 52% lower within fiber crossings than the Standard Model. On acquired diffusion MRI, FiberField's estimated fiber directions agree with those from MRtrix3's fod2fixel while also mapping microstructural properties such as diffusivity (angular difference: $10.5 \pm 7.1°$). Using neural fields allows for adaptive white matter modeling for selecting from a set of alternative models while maintaining accurate fiber property estimation.

Comment
12 pages, 7 figures. Accepted to SPIE Medical Imaging 2027: Image Processing

Closest papers

Nearest neighbours by meaning across the whole index.

Fiber-Resolved Microstructure Quantification from Multi-Shell Diffusion MRI using Detection Transformers

cs.CV cs.LGphysics.med-ph ·2026-09-30 ·Sebastian Endt, Marcus Wirth, Johannes Reinhold Schlund, Marion Irene Menzel
publishedbenchmarkcode/data similarity 0.70
Abstract · 12 pages, 4 figures, 1 table; Accepted at MICCAI 2026 Workshop CDMRI; Code: https://github.com/Marcus02W/Diffusion-DETR

Fiber orientation and compartmental microstructure are central to the characterization of white matter tissue in diffusion MRI, yet existing methods either resolve fiber orientations without quantifying microstructure, or quantify microstructure while assuming a fixed number of compartments and a single fiber direction. Nonparametric approaches that recover both require tensor-valued diffusion encoding and computationally expensive Monte-Carlo inversion of an ill-posed inverse Laplace transform. We propose to reframe this problem as an object detection-like task, adopting the Detection Transformer (DETR) architecture to jointly predict mean diffusivity (MD), fractional anisotropy (FA), main fiber direction, and signal fraction for a variable number of compartments per voxel from standard multi-shell diffusion MRI with linear encoding. Hungarian matching during training resolves permutation invariance across compartments. We introduce mean Average Precision as a reproducible benchmark metric. Evaluated on synthetic test data with up to five compartments per voxel, our model achieves $R^2=0.95$ for MD, $R^2=0.88$ for FA, and a median angular error of 4.2°, with performance scaling naturally with compartmental signal fraction.

0.66

Separating mixtures of single-fiber orientation distributions for increased sensitivity to crossing white matter fibers

eess.IV q-bio.QM ·2026-10-14 ·Adam M. Saunders, Gaurav Rudravaram, Michael E. Kim, Elyssa M. McMaster, Yifan Shuai +8 more
similarity 0.67
Abstract · 25 pages, 8 figures

Intro: Diffusion MRI allows for in vivo probing of brain tissue architecture via micron-level diffusion aggregated at the millimeter scale, but crossing white matter fibers decrease the sensitivity of downstream tasks such as microstructural modeling and tractography. Current fixel-based methods for identifying the number, orientation, and spread of fibers rely on finding the peaks of fiber orientation distributions from constrained spherical deconvolution. However, this method is biased by the spreads of nearby fibers and fails at angular separations lower than approximately 40-50 degrees. Methods: In this work, we perform a constrained nonlinear optimization called fiber segmentation by signal splitting and iterative least squares estimation (FISSILE), modeling each voxel as a mixture of single-fiber distributions. We use FISSILE to fit axially symmetric fibers in simulations and on three in vivo human subjects from the Human Connectome Project, an ex vivo raccoon brain, as well as the same human subject scanned twice at two different signal-to-noise ratios (SNRs). Results: On simulated data, FISSILE successfully identifies fibers at an angular separation of 40° and a volume fraction of 0.1 at an SNR as low as 30, while MRtrix3's fod2fixel is limited to 60° separation and 0.1 volume fraction at the same SNR. On acquired data, FISSILE identified 85.8% of white matter voxels on average in human brains and 79.4% in the raccoon with at least one fiber crossing, whereas fod2fixel identified 30.1% and 44.5%. The number of white matter fiber crossings was mildly sensitive to different noise levels in the human subject with two acquisitions. Conclusion: A method that models the crossing fiber phenomenon as an unmixing problem increases sensitivity to individual fibers for more precise characterization of anatomy.

0.18

FiberGeoText: A Vision-Language Model for Population- Level Organization of Superficial White Matter

cs.CV ·2026-10-02 ·Yuqian Chen, R. Jarrett Rushmore, Guikun Chen, Fan Zhang, Edward Yeterian +3 more
similarity 0.63
Abstract · 22 pages, 3 figures

The superficial white matter (SWM), a critical brain region for cognition across the lifespan and brain disease, contains abundant short-range association fibers whose organization remains incompletely characterized, in part because the short trajectories and highly variable cortical folding make correspondence across individuals challenging. Anatomically corresponding connections may vary in spatial location across individuals and therefore may not be adequately defined by geometric proximity alone. We introduce FiberGeoText (FGT), a vision-language model (VLM) for organizing short-range superficial white matter (SWM) streamlines reconstructed from ultra-high-resolution diffusion MRI into population-level clusters. FGT jointly represents three complementary properties of each streamline: its three-dimensional trajectory, its cortical anatomical context, and its shape. Cortical endpoint information from multiple parcellation schemes is expressed as text and encoded using a pretrained large language model (LLM), enabling heterogeneous anatomical descriptions to contribute to a common continuous representation. We evaluated FGT on acquired submillimeter 0.76 mm diffusion MRI data. Compared with state-of-the-art (SOTA) methods, FGT produced substantially greater cortical parcel coherence, within-cluster shape consistency, cluster-size consistency, and cross-subject correspondence. The trained model also generalizes well to unseen subjects with an average of 96.7% of the 5,000 learned clusters recovered, and high consistency of cluster structure between training and testing data. Together, these findings demonstrate that integrating geometric, anatomical, and shape information by learning multimodal deep embeddings with a VLM model enables robust learning of population-consistent SWM organization despite interindividual anatomical variability.

0.33

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.63
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

Trusting the Inverse: Reliability-Aware Mapping for Simulation-Based Microstructure Estimation in Diffusion MRI

cs.CE ·2026-09-30 ·Juan Luis Villarreal Haro, Ileana Jelescu, Jean-Philippe Thiran, Jonathan Rafael-Patino
similarity 0.62
Abstract

Diffusion-weighted MRI can probe tissue microstructure non-invasively, however interpreting microstructural parameter estimates remains challenging due to the intrinsic ambiguity of the inverse problem. While simulation-based approaches can incorporate increasingly realistic tissue models, they still lack voxel-wise characterisation of the reliability and degeneracy of the inferred parameters. Here, we introduce a reliability framework for simulation-based microstructure estimation based on three complementary scores that identify distinct sources of unreliability in the estimation process: out-of-distribution signals, local signal mismatch, and parameter degeneracy. The framework was implemented using a Monte Carlo dictionary of 1,050 synthetic voxels generated from geometrically realistic substrates, with parameter ranges grounded in electron microscopy measurements of rat corpus callosum. The dictionary spans biologically plausible axon radii (0.25-0.85 $μ$m), microscopic angular spread (0-10$^\circ$), packing densities (60-92%), and intrinsic diffusivities (1.75-3.0 $μ$m$^2$/ms). On synthetic data, the resulting Reliability Index correlated with actual estimation error (Spearman $ρ= -0.742$) and distinguished between extrapolation, poor local interpolation, and parameter degeneracy. Applied to in vivo corpus callosum DW-MRI in rat (256 voxels, four animals) and human (MGH-USC HCP, 18,765 voxels, nine subjects), 91% and 73% of voxels respectively exceeded $R > 0.5$. These results demonstrate how reliability-aware analysis can support the interpretation and future development of simulation-based diffusion MRI microstructure models.

0.20

Tensor-based Brain Surface Modeling and Analysis

cs.CV q-bio.NC ·2026-09-03 ·Moo K. Chung, Keith J. Worsley, Steve Robbins, Alan C. Evans
top venuehighly cited similarity 0.62
Abstract

We present a unified computational approach to tensor-based morphometry in detecting the brain surface shape differences between two clinical groups based on magnetic resonance images. Our approach is novel in a sense that we combined surface modeling, surface data smoothing and statistical analysis in a coherent unified mathematical framework. The cerebral cortex has the topology of a 2D highly convoluted sheet. Between two different clinical groups, the local surface area and curvature of the cortex may differ. It is highly likely that such surface shape differences are not uniform over the whole cortex. By computing how such surface metrics differ, the regions of the most rapid structural differences can be localized. To increase the signal to noise ratio, diffusion smoothing based on the explicit estimation of Laplace-Beltrami operator has been developed and applied to the surface metrics. As an illustration, we demonstrate how this new tensor-based surface morphometry can be applied in localizing the cortical regions of the gray matter tissue growth and loss in the brain images longitudinally collected in the group of children.

0.74

Generalizable field of view extension for diffusion MRI via conditional flow matching

cs.AI ·2026-10-12 ·Gaurav Rudravaram, Lianrui Zuo, Ema Topolnjak, Michael E. Kim, Adam M. Saunders +20 more
similarity 0.60
Abstract

Incomplete field-of-view (FOV) diffusion MRI (dMRI) acquisitions compromise whole-brain white matter analysis by excluding brain regions from tractography and connectivity studies. While deep generative models for dMRI FOV extension have been proposed, their generalizability remains limited by the acquisition-dependent nature of dMRI, where signal intensity varies with b-value, gradient direction, and scanner protocol, and the inherent 4D complexity of the data, making it difficult to train models that transfer across sites or acquisition schemes without retraining. We propose a flow-matching generative model that extends the dMRI FOV in both the superior and inferior directions by predicting apparent diffusion coefficients (ADC) in six directions, conditioned on the two nearest acquired slices and the full-FOV T1w image to enforce both local diffusion continuity and anatomical consistency. The ADC representation decouples the model from acquisition-specific b-values and gradient directions, providing a middle-ground across protocols. The model was trained on 3,103 subjects (5,105 sessions) across five different datasets spanning diverse acquisition schemes (b = 500 and 1000 s/mm$^2$; 21--192 gradient directions), four single-shell (b = 1000) and one multi-shell (b = 500/1000). Evaluated on 299 subjects across five independent datasets spanning b = 750--1500 s/mm$^2$ and 32--90 gradient directions, with single- and multi-shell schemes unseen during training, the proposed method achieves significantly improved bundle Dice score on downstream tractography (p < 0.01).

0.16

Uncertainty-Aware 3D Residual Wavelet Diffusion for Ultra Low-Field MRI Super-Resolution

cs.CV ·2026-09-21 ·Rui W. Yeow, Millie Beament, Fred Dick, Raha Razin, Martina Bocchetta +4 more
published similarity 0.59
Abstract · 11 pages, 3 figures, 1 table. Accepted at SASHIMI 2026 (MICCAI 2026 workshop). This is the version submitted for peer review

Ultra low-field MRI expands global access to neuroimaging but produces scans with low signal-to-noise ratio, reduced contrast, and thick slices. While regression-based super-resolution can recover anatomical detail for segmentation, it returns a single deterministic estimate that gives no indication of regions where the low-field input leaves anatomy underdetermined. Generative diffusion models offer an alternative by sampling the posterior distribution of plausible high-field images, quantifying this anatomical ambiguity. However, applying them to 3D whole-brain MRI is restricted by memory bottlenecks, slow sampling, and scanner domain shifts. We propose a 3D residual wavelet diffusion model that combines three ideas to overcome these hurdles. A lossless wavelet reparameterisation shrinks the spatial grid to fit a whole brain on a single GPU, residual shifting accelerates sampling by starting from the low-field input, and domain randomisation promotes scanner generalisation without paired training data. As the high-field reference is not a voxel-aligned ground truth, we evaluate downstream volumetric agreement. On a healthy cohort (n=19) imaged at 0.064T and 3T, our method matches a leading general-purpose regression approach in volumetric accuracy while additionally generating per-voxel uncertainty maps highlighting underdetermined regions. Furthermore, on a pilot dataset (n=11) of participants with cognitive impairment, disease-relevant atrophy is preserved rather than normalised towards a healthy prior. Our framework brings whole-brain posterior sampling to low-field super-resolution without sacrificing volumetric accuracy.

0.35