CS Paper Radar

Evaluating and Calibrating Diffusion Model-derived Uncertainty for Quantitative MRI Mapping

Shishuai Wang, Stefan Klein, Juan A. Hernandez-Tamames, Dirk H. J. Poot

cs.CV ·submitted 2026-08-12 11:30 UTC · v1
published

Abstract

Quantitative MRI (qMRI) provides standardised tissue parameter maps, but the reliability of deep learning-based qMRI mapping methods is often not explicitly characterised. In this work we systematically evaluate uncertainty maps for quantitative MRI derived from multiple inferences of a data-consistent diffusion model-based qMRI framework. Evaluation on synthetic test data assessed error-awareness, high-error detection, selective prediction, and Gaussian interval calibration. Diffusion model-derived uncertainty was positively associated with the mapping error, while risk-coverage analysis showed that excluding high-uncertainty voxels reduced the retained error. However, the raw uncertainty was poorly calibrated for quantitative interval interpretation. Calibration was substantially improved using a post-hoc procedure combining prediction-value-dependent bias correction with scalar uncertainty scaling. Qualitative evaluation on a healthy volunteer showed spatially meaningful uncertainty patterns. These results indicate that diffusion model-derived uncertainty is informative for reliability assessment and selective prediction, but requires calibration for quantitative interval interpretation.

Comment
11 pages, 6 figures. Accepted at the MICCAI 2026 Workshop on Uncertainty for Safe Utilization of Machine Learning in Medical Imaging (UNSURE 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Trusting the Inverse: Reliability-Aware Mapping for Simulation-Based Microstructure Estimation in Diffusion MRI

cs.CE ·2026-09-30 ·Juan Luis Villarreal Haro, Ileana Jelescu, Jean-Philippe Thiran, Jonathan Rafael-Patino
similarity 0.73
Abstract

Diffusion-weighted MRI can probe tissue microstructure non-invasively, however interpreting microstructural parameter estimates remains challenging due to the intrinsic ambiguity of the inverse problem. While simulation-based approaches can incorporate increasingly realistic tissue models, they still lack voxel-wise characterisation of the reliability and degeneracy of the inferred parameters. Here, we introduce a reliability framework for simulation-based microstructure estimation based on three complementary scores that identify distinct sources of unreliability in the estimation process: out-of-distribution signals, local signal mismatch, and parameter degeneracy. The framework was implemented using a Monte Carlo dictionary of 1,050 synthetic voxels generated from geometrically realistic substrates, with parameter ranges grounded in electron microscopy measurements of rat corpus callosum. The dictionary spans biologically plausible axon radii (0.25-0.85 $μ$m), microscopic angular spread (0-10$^\circ$), packing densities (60-92%), and intrinsic diffusivities (1.75-3.0 $μ$m$^2$/ms). On synthetic data, the resulting Reliability Index correlated with actual estimation error (Spearman $ρ= -0.742$) and distinguished between extrapolation, poor local interpolation, and parameter degeneracy. Applied to in vivo corpus callosum DW-MRI in rat (256 voxels, four animals) and human (MGH-USC HCP, 18,765 voxels, nine subjects), 91% and 73% of voxels respectively exceeded $R > 0.5$. These results demonstrate how reliability-aware analysis can support the interpretation and future development of simulation-based diffusion MRI microstructure models.

0.20

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.65
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

Accurate MRI-free PET Quantification and Reliability Assessment via CT-to-MRI Synthesis and Conformal Prediction

cs.CV ·2026-10-29 ·Jungwoo Seo, Seung Yun Choi, Kun Ho Lee, Seun Jeon, Byoung Seok Ye +1 more
similarity 0.64
Abstract · 28 pages, 8 figures, including supplementary material. Submitted to Medical Image Analysis

Standardized uptake value ratio (SUVR) quantification of amyloid PET commonly relies on a subject-specific T1-weighted MRI, yet a usable MRI is not always available. We therefore combined CT-to-MRI synthesis with conformal prediction for MRI-free PET quantification with reliability assessment. A slice-consistent Brownian Bridge Diffusion Model was strengthened with multi-dataset training and data-source conditioning to enrich the anatomical prior learned from MRI, and with expanded multi-slice CT context to exploit the through-plane continuity of subject-specific anatomy in CT. Synthetic MRI was used for FreeSurfer-based anatomical parcellation and PET quantification, while deep-ensemble uncertainty was calibrated with conformal prediction to estimate a plausible range for the corresponding real MRI-based SUVR. On $^{11}$C-PiB PET from OASIS-3, the proposed method achieved the highest synthesis and parcellation fidelity among the compared methods. Mean cortical SUVR from the proposed synthetic MRI agreed closely with the real MRI-based reference (MAE $0.016 \pm 0.015$, Pearson $r = 0.9987$) and yielded the same amyloid-positivity classification as the real MRI in all 87 test subjects at the prespecified cut-off. Conformal prediction achieved empirical coverage close to the prespecified levels, and at 90% target coverage, 85 of 87 subjects had prediction intervals that supported an unambiguous amyloid-positivity decision. Zero-shot evaluation on an independent external cohort showed that the proposed CT-to-MRI model could support PET quantification without retraining, although conformal calibration required target-cohort recalibration to recover the intended coverage. These findings support CT-to-MRI-based MRI-free PET quantification as a promising approach for providing accurate SUVR measurements and an explicit assessment of their reliability.

0.31

MUMINS: Metadata-conditioned Uncertainty-aware Medical Image Next-state Synthesis

cs.CV cs.AI ·2026-09-15 ·Anna Oliveras, Roger Marí, Rafael Redondo, Oriol Guardià, Cynthia Ifeyinwa Ugwu +5 more
code/data similarity 0.64
Abstract · Supplementary material to follow in future versions

Forecasting anatomical changes such as tumor growth and neurodegeneration is a challenging generative vision task. Morphological evolution is subtle relative to static anatomy, highly patient-specific, and inherently stochastic. Existing methods struggle with several issues: deterministic networks ignore biological stochasticity, while standard diffusion models require computationally prohibitive multi-pass sampling to quantify uncertainty. We propose MUMINS (Metadata-conditioned Uncertainty-aware Medical Image Next-state Synthesis), an efficient diffusion framework that jointly diffuses a baseline scan and its follow-up residual, summed to synthesize the follow-up scan, while concurrently predicting a spatial uncertainty map, in a single reverse diffusion process. Conditioned on the time interval and relevant metadata, it preserves fine-grained anatomy by dynamically re-injecting the baseline as a soft anchor at every denoising step, and a negative-log-likelihood head learns the uncertainty map to explicitly flag error-prone regions. Designed without organ-specific heuristics, the same architecture is reused across anatomies via separate, dataset-specific retraining. Extensive evaluations demonstrate that dataset-specific retraining of MUMINS matches or outperforms dedicated, domain-specific state-of-the-art methods on lung CT (PNG) and brain MRI (OASIS-3). Project page: https://aolivtous.github.io/publications/mumins.html.

0.46

Towards Trustworthy AI for Glioma Diagnosis: A Task-Aware Evaluation of Uncertainty Quantification

cs.CV cs.AI ·2026-09-30 ·Gonzalo Esteban Mosquera Rojas, Sebastian R. van der Voort, Carolin M. Pirkl, Sandeep Kaushik, Marion Smits +1 more
top venue similarity 0.64
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:033

Uncertainty Quantification (UQ) is a key requirement for trustworthy AI in high-stakes medical image analysis. In this work, we evaluate UQ in a multi-task Deep Learning framework for MRI-based glioma diagnosis that performs tumor segmentation and predicts IDH mutation status, 1p/19q co-deletion status, and tumor grade. Monte Carlo Dropout (MCD) is used for a detailed task-aware analysis of predictive, aleatoric, and epistemic uncertainty. We assess MC sample convergence, calibration, error detection, selective prediction, associations with segmentation performance, and the effect of voxel-wise uncertainty aggregation on case-level reliability. We also compare MCD with Deep Ensembles (DE) and Monte Carlo Deep Ensembles (MCDE), examine interactions between segmentation quality and classification, and evaluate a composite trust score integrating segmentation and classification uncertainty. Across tasks, uncertainty estimates supported meaningful error detection, while calibration depended on the dropout rate, with moderate rates yielding the most reliable probabilities. Uncertainty decomposition provided task-dependent interpretability but did not consistently improve error detection over predictive uncertainty alone. DE and MCDE showed comparable operational utility, with no method consistently dominating across tasks and metrics. The composite trust score did not consistently outperform classification uncertainty for selective prediction. Overall, our results provide a task-aware evaluation strategy and practical guidance for the development of trustworthy AI for glioma diagnosis.

0.41

Bayesian Uncertainty Quantification for fMRI Functional Connectivity via Simulation-Based Inference

cs.LG stat.ML ·2026-09-24 ·Simon Carter, Zeming Kuang, Lilianne R. Mujica-Parodi, Helmut H. Strey
similarity 0.63
Abstract · 29 pages, 4 figures

Optimizing fMRI scan duration and spatial resolution is critical for experimental design, yet traditional correlation-based approaches cannot quantify uncertainty or disentangle scanner measurement noise from true neural variability across subjects. Without principled uncertainty bounds, researchers cannot know whether a protocol is long enough to reliably estimate connectivity, or whether between-subject differences reflect biological variation or noise. We present a Bayesian framework modeling BOLD dynamics as coupled Ornstein-Uhlenbeck processes, using Sequential Neural Posterior Estimation to obtain connectivity posteriors while accounting for frequency-independent measurement noise across the BOLD spectrum. Applied to N = 28 healthy controls (55 scans) at 7T using a functional network atlas (65 DMN regions), the framework quantifies uncertainty across its sources: scanner noise, subject variability, and acquisition length. Spatial analysis identifies a mean of 46 voxels per ROI, roughly half of typical region sizes, as sufficient to achieve 90% of asymptotic precision. At the single-subject level, 7T reaches its within-session precision plateau in approximately 7 minutes versus 10 minutes for 3T, a 40% reduction in required scan time, providing the first direct, model-based quantification of the scan-time advantage conferred by higher field strength. At the population level, 3T requires roughly 37 times more per-subject scan time than 7T for the pooled curves to converge, confirming a consistent advantage of higher field strength at every timescale. Together these findings provide concrete, scanner-specific guidance for protocol optimization, with direct implications for reducing acquisition costs and improving the reliability of connectivity-based clinical biomarkers. We provide code enabling researchers to derive these bounds from their own data.

0.28

Multimodal Deep Learning for Uncertainty-Aware Radiation Pneumonitis Risk Prediction

eess.IV ·2026-08-28 ·Jin Yang, Tian Liu, Jing Wang, Sooyun Caroline Tavolacci, Benjamin Tran +5 more
similarity 0.63
Abstract · 28 pages, 9 figures, 5 tables

Radiation pneumonitis (RP) is a potentially serious complication of thoracic radiotherapy, making reliable risk prediction important for identifying high-risk patients and guiding effective toxicity management. Although deep learning models can predict RP risk, uncertainty quantification remains underdeveloped in radiation toxicity assessment. We developed a Multimodal Bayesian Diffusion Transformer (MM-DiT) that integrates pretreatment computed tomography (CT) and three-dimensional planning dose distributions for RP risk prediction and uncertainty quantification. MM-DiT combines self-supervised multimodal representation learning with Bayesian classification to estimate individual risk and characterize aleatoric, epistemic, and label uncertainty. In independent Mount Sinai Health System (MSHS) and RTOG cohorts, MM-DiT achieved areas under the receiver operating characteristic curve (AUCs) of $0.89$ and $0.86$, respectively, with expected calibration errors of $0.02$ and $0.03$. Incorporating post-treatment CT increased AUC to $0.95$ in MSHS and reduced aleatoric and epistemic uncertainty by approximately $40-45\%$ and $40\%$, respectively. These findings establish a framework for uncertainty-aware radiation toxicity prediction that complements risk estimates with information about predictive reliability. By integrating multimodal learning and uncertainty quantification, MM-DiT may advance more interpretable and trustworthy AI-assisted toxicity assessment and support individualized radiotherapy planning.

0.19

Contrastive uncertainty learning for robust multi-structure segmentation in lower-pelvic MR

cs.CV cs.LG ·2026-10-14 ·Bilal Sidiqi, Yipei Wang, Wen Yan, Shaheer U. Saeed, Daniel C. Alexander +1 more
top venue similarity 0.62
Abstract · UNSURE MICCAI 2026

Boundary delineation of anatomical structures in prostate MRI is often compromised by regional ambiguity. Automated segmentation methods relying on global overlap loss functions tend to be insensitive to surface deviations, leading to significant errors in ambiguous regions. Most existing uncertainty-aware methods treat uncertainty as a post-hoc quality indicator or prediction filter. We propose Contrastive Uncertainty Learning (CUL), a supervised framework that uses predictive uncertainty to directly guide representation learning. Using Monte Carlo Dropout, CUL identifies voxel-wise uncertainty and structures the embedding geometry accordingly: low-uncertainty, correctly predicted features form stable voxels while high-uncertainty or misclassified features are actively repelled, preventing feature collapse at difficult boundaries. We evaluate CUL on a 589-scan 3D prostate MRI multi-structure segmentation task (8 anatomical structures) using a ViT with UperNet decoder architecture. Average Dice ($83.38\%$) remains comparable to the baseline ($83.35\%$), while surface distance decreases significantly ($p<0.001$) across 6 of 8 anatomical structures. A hard-case analysis reveals a $22{\times}$ asymmetry between significantly improved and degraded cases ($18.8\%$ vs $0.9\%$). Ablation studies show that removing uncertainty-guided sample selection eliminates improvements for the transition zone, while replacing the contrastive objective with a boundary loss additionally removes bladder improvements, demonstrating that both uncertainty-guided sampling and the contrastive objective are essential for the observed gains. These findings demonstrate that the proposed uncertainty-guided representation learning is a useful mechanism for reducing the risk of extreme errors in safety-critical medical segmentation

0.30