Accurate MRI-free PET Quantification and Reliability Assessment via CT-to-MRI Synthesis and Conformal Prediction

Jungwoo Seo, Seung Yun Choi, Kun Ho Lee, Seun Jeon, Byoung Seok Ye, Jiook Cha

cs.CV ·submitted 2026-10-29 17:11 UTC · v1

Abstract

Standardized uptake value ratio (SUVR) quantification of amyloid PET commonly relies on a subject-specific T1-weighted MRI, yet a usable MRI is not always available. We therefore combined CT-to-MRI synthesis with conformal prediction for MRI-free PET quantification with reliability assessment. A slice-consistent Brownian Bridge Diffusion Model was strengthened with multi-dataset training and data-source conditioning to enrich the anatomical prior learned from MRI, and with expanded multi-slice CT context to exploit the through-plane continuity of subject-specific anatomy in CT. Synthetic MRI was used for FreeSurfer-based anatomical parcellation and PET quantification, while deep-ensemble uncertainty was calibrated with conformal prediction to estimate a plausible range for the corresponding real MRI-based SUVR. On $^{11}$C-PiB PET from OASIS-3, the proposed method achieved the highest synthesis and parcellation fidelity among the compared methods. Mean cortical SUVR from the proposed synthetic MRI agreed closely with the real MRI-based reference (MAE $0.016 \pm 0.015$, Pearson $r = 0.9987$) and yielded the same amyloid-positivity classification as the real MRI in all 87 test subjects at the prespecified cut-off. Conformal prediction achieved empirical coverage close to the prespecified levels, and at 90% target coverage, 85 of 87 subjects had prediction intervals that supported an unambiguous amyloid-positivity decision. Zero-shot evaluation on an independent external cohort showed that the proposed CT-to-MRI model could support PET quantification without retraining, although conformal calibration required target-cohort recalibration to recover the intended coverage. These findings support CT-to-MRI-based MRI-free PET quantification as a promising approach for providing accurate SUVR measurements and an explicit assessment of their reliability.

Comment
28 pages, 8 figures, including supplementary material. Submitted to Medical Image Analysis

Closest papers

Nearest neighbours by meaning across the whole index.

3D CT-to-PET Translation via Latent Brownian Bridge Diffusion

cs.CV cs.AI ·2026-09-11 ·Sarita Mourya, Francesco Di Feola, Pierangelo Veltri, Paolo Soda
similarity 0.68
Abstract

Computed tomography (CT) and positron emission tomography (PET) provide complementary anatomical and functional information for cancer diagnosis and treatment planning. However, the widespread use of PET is limited by high radiation exposure, elevated costs, and restricted availability. To address these limitations, deep learning-based CT-to-PET translation has emerged as a promising approach for synthesizing PET-like information directly from CT images, although accurately modeling the large cross-modal gap remains challenging. In this work, we propose a 3D CT-to-PET translation framework based on latent Brownian Bridge Diffusion (BBDM). The method consists of two stages. First, a Variational Autoencoder (VAE) is trained on paired CT-PET patches, integrating contrastive learning to improve latent alignment between anatomical and metabolic representations. Second, a BBDM is trained in the latent space to translate CT latent representations into their corresponding PET counterparts. The translated PET latents are then decoded and stitched to reconstruct the final 3D PET volume. We evaluate the proposed approach on two publicly available datasets. Quantitative results based on image fidelity and lesion-level PET-specific metrics demonstrate improved performance compared with competing methods. In particular, the proposed approach improves PET signal fidelity, better preserves clinically relevant uptake patterns, and shows improved performance in preserving small-lesion metabolic activation, paving the way for virtual imaging applications.

0.22

MedicalDPO: Multi-Objective Direct Preference Optimization for CT to PET Translation

cs.CV ·2026-11-16 ·Huiting Zhang, Yingxin Cai, Siyuan Wang, Xi Yang, Yuyao Yan +2 more
similarity 0.68
Abstract

CT-to-PET synthesis estimates functional PET images from anatomical CT scans for auxiliary analysis, representation pretraining, and missing-modality completion. Brownian Bridge diffusion models can produce multiple PET candidates of different quality under the same CT condition, exposing an intra-condition quality hierarchy. Candidate quality spans complementary spatial, structural, and intensity dimensions, while DPO-only fine-tuning may compromise absolute synthesis fidelity. We propose MedicalDPO which converts this hierarchy into preference supervision automatically constructed from paired CT-PET training data. Multiple candidates are ranked across the three fidelity dimensions, and strict cross-metric verification retains preferred-rejected pairs with consistent quality separation. Relative denoising-error preference optimization is jointly trained with the original Brownian Bridge objective to anchor the pretrained CT-to-PET mapping, while condition-balanced multi-pair rotation distributes preference supervision across CT conditions. Experiments on BBDM and CPDM show improvements across LPIPS, MAE, SSIM, and PSNR. Further analyses demonstrate metric complementarity and clear pair separation, while ablations show that the original training objective prevents the substantial degradation caused by DPO-only fine-tuning.

0.12

Generative Priors for Total-Body PET Reconstruction

eess.IV cs.CV ·2026-09-18 ·Movindu Dassanayake, George Webber, Denis Prokopenko, Julia A. Schnabel, Andrew J. Reader
published similarity 0.65
Abstract · MICCAI RIME 2026 (Accepted Poster)

Total-body positron emission tomography (TB-PET) enables fast, low-dose, and dynamic imaging over a long axial field of view, but reconstruction remains challenging due to reduced counts, large image volumes, and increased data dimensionality. Generative models offer powerful learned priors for low-count PET, yet explicit PET measurement conditioning at TB scale has not been demonstrated. Inspired by PET decomposed diffusion sampling (PET-DDS), we propose TB-PET-DDS, a reconstruction framework that combines a CT-conditioned generative prior with patient-specific list-mode PET data. During reverse diffusion, PET consistency is enforced using a closed-form 3D TB-PET maximum-a-posteriori expectation maximisation fusion update, rather than relying solely on image-domain conditioning. The synthetic measurements are generated from the low-dose vendor reconstruction, providing a controlled inverse problem and retaining a full-dose reference. Proof-of-concept evaluation was performed on a single clinical TB-PET acquisition, with reconstruction hyperparameters selected against the full-dose reconstruction from the same case for all models. TB-PET-DDS improved NRMSE and SSIM relative to the DDIM and Image-DDS baselines, improving through-plane consistency in coronal views while enhancing agreement with the measured PET data. Although smoothed low-dose vendor reconstructions achieved the best global voxel-wise metrics, TB-PET-DDS produced the lowest liver coefficient of variation. These results demonstrate the feasibility of measurement conditioned diffusion reconstruction at TB scale and provide an initial route towards learned, projector-consistent generative reconstruction for low-count TB-PET imaging.

0.13

Domain-Adapted Latent Diffusion Models for CT-to-PET Image Translation

cs.CV ·2026-10-26 ·Yann Bourdé, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer
similarity 0.64
Abstract

Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible than Computed Tomography (CT) due to its high cost, infrastructure requirements, and reliance on injected radioactive tracers. CT-to-PET image translation using generative models aims to address this disparity, yet state-of-the-art diffusion-based methods are limited by the scarcity of paired training data. To overcome this, we propose a domain-adapted latent diffusion framework that transfers natural-image priors using a relatively small dataset of 21,930 paired CT/PET slices, incorporating a signed power transform to resolve extreme intensity sparsity in PET data. Compared to CPDM, a state-ofthe-art baseline for CT-to-PET image translation, our approach yields superior performance in pixel-wise reconstruction and localized tumor fidelity, demonstrating effective transfer of natural-image priors to the medical domain. We further provide a systematic analysis of evaluation metric reliability for sparse PET data, showing that standard full-image metrics can be misleading indicators of translated image quality, and propose background-filtered and mask-restricted metrics as more clinically meaningful alternatives.

0.16

Bridging Modalities on the Cortex: Surface-based MRI to PET Translation with a Diffusion Bridge

cs.CV cs.AI ·2026-09-17 ·Yitong Li, Alexandra Samoylova, Fabian Bongratz, Timo Grimmer, Dennis M. Hedderich +2 more
code/data similarity 0.64
Abstract

Cortical hypometabolism measured by Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) is a highly sensitive biomarker for dementia diagnosis. However, high costs, radiation exposure, and limited accessibility constrain its clinical utility. While cross-modal synthesis from Magnetic Resonance Imaging (MRI) offers a promising alternative, existing volumetric generation methods do not explicitly account for the highly folded cortical geometry, where disease-related patterns predominantly reside. To address this, we introduce a novel surface-based diffusion bridge framework DB-SUiT for MRI-to-PET translation that operates natively on the cortical manifold. A conditional Spherical U-shaped vision Transformer (SUiT) is specifically designed to model the intricate cross-modal relationships while preserving surface topology. It combines spherical convolutional encoders for multi-scale surface feature extraction with bottleneck Transformers to capture long-range spatial dependencies, while incorporating demographic and subcortical conditions to refine the synthesis. Evaluated on two datasets, including subjects with different dementia types, DB-SUiT demonstrates high-fidelity synthesis that substantially outperforms other baselines. In automated dementia classification, synthesized PET surfaces improve performance over MRI by 14.2% and PET volumes by 11.3%, approaching the performance of real PET surfaces. In a blinded reader study, synthetic PET achieved 85.5% diagnostic accuracy, compared with 75.8% for MRI and 95.2% for real PET. This further demonstrates cross-cohort and cross-pathology generalization, as the model was evaluated without retraining on an external cohort that included a dementia subtype not represented during training. Our code is available at https://github.com/ai-med/DB-SUiT.

0.32

Evaluating and Calibrating Diffusion Model-derived Uncertainty for Quantitative MRI Mapping

cs.CV ·2026-08-12 ·Shishuai Wang, Stefan Klein, Juan A. Hernandez-Tamames, Dirk H. J. Poot
published similarity 0.64
Abstract · 11 pages, 6 figures. Accepted at the MICCAI 2026 Workshop on Uncertainty for Safe Utilization of Machine Learning in Medical Imaging (UNSURE…

Quantitative MRI (qMRI) provides standardised tissue parameter maps, but the reliability of deep learning-based qMRI mapping methods is often not explicitly characterised. In this work we systematically evaluate uncertainty maps for quantitative MRI derived from multiple inferences of a data-consistent diffusion model-based qMRI framework. Evaluation on synthetic test data assessed error-awareness, high-error detection, selective prediction, and Gaussian interval calibration. Diffusion model-derived uncertainty was positively associated with the mapping error, while risk-coverage analysis showed that excluding high-uncertainty voxels reduced the retained error. However, the raw uncertainty was poorly calibrated for quantitative interval interpretation. Calibration was substantially improved using a post-hoc procedure combining prediction-value-dependent bias correction with scalar uncertainty scaling. Qualitative evaluation on a healthy volunteer showed spatially meaningful uncertainty patterns. These results indicate that diffusion model-derived uncertainty is informative for reliability assessment and selective prediction, but requires calibration for quantitative interval interpretation.

0.61

Evidence Before Accuracy: A MRI-PET Fusion Network for Alzheimer Disease Classification with Causal Regional Validation

cs.CV ·2026-09-28 ·Saeid Firouzi Daghigh, Saeed Ayat
similarity 0.63
Abstract

Deep learning models for Alzheimer disease (AD) classification routinely report near-perfect discrimination, yet few are shown to rest on AD-relevant neurobiology rather than on dataset artifacts, subject-level leakage, or non-brain image content. We present a fusion network combining T1 MRI and FDG PET across axial, coronal, and sagittal planes, trained on ADNI consists of 554 paired subjects. The fusion model reaches AUC 0.962, accuracy 0.909, and F1 0.891, competitive with recent 3D CNN and multimodal transformer systems at substantially lower cost. We first quantify how much modality, plane and slice geometry matter. A validation-only search over slice centres and neighbour spacings moves AUC by 0.180 for MRI and 0.078 for PET, selecting narrow spacing for MRI and wide spacing for PET, with the chosen coronal centres falling on the hippocampal body and on the posterior cingulate respectively. The contribution, however, is the evidence layer built around that number. Shortcut controls collapse the model to AUC 0.622 (silhouette), 0.608 (exterior), and 0.500 (blank), and a label-permutation null yields 0.456. Forward region-of-interest (ROI) ablation shows that masking medial temporal cortex in MRI and the posterior default-mode network (DMN) in PET produces the largest shift in the AD logit, while area-matched controls remain indistinguishable from that null. Reverse ROI ablation shows that the medial temporal lobe alone retains 89.2% of above-chance discrimination in MRI and the posterior DMN alone retains 79.0% in PET. A quantitative comparison of attribution methods shows occlusion sensitivity reaching 3.5-5.0* enrichment inside a priori AD regions against 0.10-0.43* in controls. Ablation and attribution independently establish a biologically correct double dissociation: hippocampal evidence is carried by MRI, posterior cingulate evidence by PET.

0.12

Region-Weighted Losses and Model Fusion for Cross-Modal PET Attenuation Correction

cs.CV ·2026-08-22 ·Khoa Tuan Nguyen, Joris Vankerschaver, Wesley De Neve
publishedbenchmark similarity 0.62
Abstract · ntkhoa team submission for BIC-MAC MICCAI26 challenge (https://www.codabench.org/competitions/12555/#/results-tab)

We describe our approach to the Big Cross-Modal Attenuation Correction (BIC-MAC) challenge, which asks for a pseudo-CT in Hounsfield Units to be synthesized from Non-Attenuation-Corrected PET (NAC-PET), DIXON MRI and a topogram, and scores both the pseudo-CT and the Attenuation-Corrected PET (AC-PET) reconstructed from it. Three ideas carried our improvements over the organizers' 3D U-Net baseline. The loss matters more than the architecture: we compute the $L_1$ error in the Carney attenuation-coefficient ($μ$) space that the CT metric itself uses, weighted by anatomical region. Only once that loss was in place did the unregistered DIXON MRI work as extra input channels. A fixed convex combination of two independently trained models then beat both of its members on three of the four metrics and ranks first overall on the public validation leaderboard.

0.35