CS Paper Radar

Contrastive uncertainty learning for robust multi-structure segmentation in lower-pelvic MR

Bilal Sidiqi, Yipei Wang, Wen Yan, Shaheer U. Saeed, Daniel C. Alexander, Yipeng Hu

cs.CV cs.LG ·submitted 2026-10-14 14:23 UTC · v1
top venue

Abstract

Boundary delineation of anatomical structures in prostate MRI is often compromised by regional ambiguity. Automated segmentation methods relying on global overlap loss functions tend to be insensitive to surface deviations, leading to significant errors in ambiguous regions. Most existing uncertainty-aware methods treat uncertainty as a post-hoc quality indicator or prediction filter. We propose Contrastive Uncertainty Learning (CUL), a supervised framework that uses predictive uncertainty to directly guide representation learning. Using Monte Carlo Dropout, CUL identifies voxel-wise uncertainty and structures the embedding geometry accordingly: low-uncertainty, correctly predicted features form stable voxels while high-uncertainty or misclassified features are actively repelled, preventing feature collapse at difficult boundaries. We evaluate CUL on a 589-scan 3D prostate MRI multi-structure segmentation task (8 anatomical structures) using a ViT with UperNet decoder architecture. Average Dice ($83.38\%$) remains comparable to the baseline ($83.35\%$), while surface distance decreases significantly ($p<0.001$) across 6 of 8 anatomical structures. A hard-case analysis reveals a $22{\times}$ asymmetry between significantly improved and degraded cases ($18.8\%$ vs $0.9\%$). Ablation studies show that removing uncertainty-guided sample selection eliminates improvements for the transition zone, while replacing the contrastive objective with a boundary loss additionally removes bladder improvements, demonstrating that both uncertainty-guided sampling and the contrastive objective are essential for the observed gains. These findings demonstrate that the proposed uncertainty-guided representation learning is a useful mechanism for reducing the risk of extreme errors in safety-critical medical segmentation

Comment
UNSURE MICCAI 2026
Journal ref
Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026 Workshops and Challenges

Closest papers

Nearest neighbours by meaning across the whole index.

Uni-Light: An Ultra-Lightweight Framework via Uncertainty-Aware Knowledge Distillation for Brain Tumour Segmentation

cs.CV ·2026-09-06 ·Libing Kuang, Soren Salehi, Ziling Wu, Ahmad P. Tafti, Armaghan Moemeni
similarity 0.71
Abstract

Accurate 3D brain tumour segmentation from multi-modal Magnetic Resonance Imaging (MRI) is essential for clinical diagnosis and treatment planning. Existing brain tumour segmentation methods often suffer from heavy computational demands, while current lightweight architectures frequently lack the capacity to maintain segmentation fidelity in complex tumour regions. To address these issues, we propose a novel ultra-lightweight framework (Uni-Light) that achieves high-fidelity segmentation with substantially reduced computational overhead. It combines multi-scale convolutions with an uncertainty-aware knowledge distillation scheme that directs the student model toward hard-to-classify regions, complemented by a Signed Distance Field boundary loss for geometric constraints. Experimental results on BraTS2023-GLI and MSD-BTS datasets demonstrate that Uni-Light reduces parameters by 97.56%, floating-point operations (FLOPs) by 73.03%, and inference memory footprint by 81.58%, while surpassing the state-of-the-art model by an average of 1.47% in Dice score, offering a highly competitive trade-off between segmentation accuracy and computational efficiency in resource-constrained clinical settings. This work also advances data engineering for medical imaging by demonstrating that teacher model uncertainty can be exploited as a data-driven supervisory signal, re-prioritising the training data distribution without requiring additional annotation.

0.24

Segmentation Confidence for Arbitrary CNNs

cs.CV ·2026-10-27 ·Baris Oguz, Xing Yao, Claudia Tawil, Alison Pouch, Brett Byram +3 more
published similarity 0.70
Abstract · 5 pages, 6 figures, published in ISBI 2026

Convolutional neural networks (CNN) are widely used for medical image segmentation. However, they lack an inherent measure of confidence. Existing methods for estimating prediction uncertainty often require a custom network architecture and/or dedicated training setups and need to be trained from scratch. In addition, the deduction of a single confidence score per input from the uncertainty maps is not always straightforward. In this study, we explore voxel-based uncertainty estimation methods that can be added to existing segmentation pipelines without training from scratch. We also propose a novel method to estimate a single confidence score from the uncertainty maps. Our evaluations on different ROIs and modalities suggest that our confidence score can predict segmentation performance in unseen data.

0.25

DART: Scaling a Shape Representation Across Anatomical Classes and Imaging Modalities

cs.CV ·2026-10-20 ·Koushik Swarna, Pedro R. A. S. Bassi, Lam Ngo, Wenxuan Li, Jiancheng Yang +2 more
code/data similarity 0.70
Abstract

Current state-of-the-art segmentation models still produce anatomically implausible shapes, such as broken vessels and fragmented glands, on the structures that are hardest to segment. Learned shape representations capture what structures look like and can help correct these errors, but most cover a fixed set of anatomical classes. Extending this coverage across classes and imaging modalities is costly because it often requires new voxel-level annotations. We propose Diffusion for Anatomical Reshaping with Text (DART), which learns a shared shape representation from segmentation probabilities. It uses anatomical descriptions to correct these probabilities without receiving medical images. Across 13 public benchmarks, absolute Dice gains reach 31% for individual gallbladder cases in CT and 10% for individual prostate cases in MRI. Using existing segmentation predictions, we scale a single shape representation from 50 to 377 anatomical classes without new voxel-level annotations for correction training. The shared representation also corrects four lesion classes absent from training and transfers from CT to MRI without retraining. Corrected labels also improve segmentation models, raising one model's Dice from 57.1% to 67.5%. The same pipeline supports annotations for 45,000 CT scans. These results suggest that sharing shape information within and across classes can reduce the need for new voxel-level annotations when extending segmentation to more anatomical classes and imaging modalities. The model is available at https://huggingface.co/Koushik45/DART-Seg

0.26

Uncertainty-aware Coarse-to-Fine Main Pancreatic Duct Segmentation for Width Measurement in 3D MRCP

cs.CV ·2026-10-29 ·Zipei Zhang, Jaakko Sahlsten, Mikko Saukkoriipi, Johanna Ronkainen, Mona Lehto +3 more
similarity 0.67
Abstract

Assessment of the main pancreatic duct (MPD) from volumetric magnetic resonance cholangiopancreatography (MRCP) scans is an essential task for ductal dilatation diagnosis and pancreatic cancer analysis. However, manual assessment is affected by reader variability in which automated analysis may assist. Nevertheless, fully automated and uncertainty-aware MPD analysis from volumetric MRCP remains underexplored area of research. In this study, we propose an automatic and uncertainty-aware deep learning-based pipeline for MPD segmentation and maximum-width analysis from MRCP scans. A coarse localisation model first identifies the ductal region-of-interest, followed by a fine model that segments the MPD within the region. The dataset consists of 256 MPD-segmented MRCP scans from 69 patients. A randomly selected holdout test subset of 14 patients with 55 MRCP volumes was used for evaluation. We employed a five-model cross-validation ensemble for improved performance and uncertainty estimation. The best MPD segmentation performance was 0.634 DSC, 0.744 precision, and 0.593 recall. The mean absolute error for maximum MPD width prediction was 0.355~mm and dilated MPD ($\geq 5$~mm) was detected with 75.0\% sensitivity and 74.4\% specificity. These novel results suggest that automated MPD segmentation can be used to aid MRCP-based duct measurements.

0.19

Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation

cs.CV ·2026-10-01 ·Samuel Hart, Ahmad Yahya, Ahmed Karam Eldaly
theory similarity 0.67
Abstract · 12 pages

While state-of-the-art automated models for medical image segmentation achieve high mean performance, they frequently suffer from localized, catastrophic failures that preclude safe clinical deployment, particularly in neuro-oncology. Interactive segmentation frameworks mitigate this by incorporating human oversight, but traditionally impose prohibitive cognitive and temporal workloads by requiring clinicians to manually search for errors. In this project, we present an efficient, Hybrid Structural-Aleatoric Human-in-the-Loop framework for glioma segmentation that bridges the gap between automated baseline performance and surgical-grade precision, achieving sub-2.0 mm HD95 on curated benchmarks while providing safety-net routing for structural failures across real-world clinical data. By extracting voxel-wise Test-Time Augmentation (TTA) uncertainty and applying hierarchical topological filtering, our method proactively isolates high-risk structural anomalies. We comprehensively evaluated our approach on a challenging out-of-distribution clinical stress-test cohort (N = 362). Operating under a simulated Human Oracle, the framework improved the Whole Tumor (WT) Dice score from 0.891 to 0.914 and reduced the 95th percentile Hausdorff Distance (HD95) from 5.82 mm to 4.76 mm. Critically for surgical safety, the system rescued severe boundary failures in the Tumor Core, reducing mean HD95 from 17.96 mm to 14.83 mm (improving absolute TC Dice to 0.356). These spatial rescues were achieved while demanding a median interactive workload of just 11.3% of the target volume. Acknowledging this as a simulated upper bound lacking real-world cognitive friction, the framework nevertheless demonstrates a highly Pareto-efficient pathway for safely deploying clinical AI.

0.15

Beyond Boundary Noise: Aggregated Aleatoric Uncertainty Fails to Capture Presence Ambiguity in 3D Lung Nodule Segmentation

cs.CV cs.LG ·2026-08-14 ·Simon Baur, Arne Schernich, Ekin Böke, Wojciech Samek, Jackie Ma
similarity 0.66
Abstract

Uncertainty estimation is critical for the safe clinical deployment of deep learning in medical image segmentation, with aleatoric uncertainty theoretically designed to capture irreducible data ambiguity. However, whether entropy-based measures reflect clinically meaningful ambiguity, i.e. case-level disagreement about whether a pathology is present at all, remains poorly understood. Contrary to most prior work, which focused on pixel-wise boundary disagreement, we systematically evaluate how well aleatoric uncertainty captures presence ambiguity. Our evaluation spans 3D lung nodule segmentation across four architectures with Monte Carlo dropout and deep ensembles, on LIDC-IDRI and an external validation cohort (LNDb). We find that entropy-based uncertainty maps align with boundary noise and minor drawing variation but carry insufficient discriminative signal for presence ambiguity. In contrast, a lightweight supervised ambiguity head trained on frozen segmentation features substantially outperforms all entropy-aggregation-based baselines across architectures, metrics, and both cohorts, and matches or exceeds methods that explicitly model ambiguity under disagreement supervision (Probabilistic U-Net, Annotator-Confusion 3D-UNet). A qualitative feature-space analysis shows that presence ambiguity is already encoded in the frozen encoder features of pixel-wise-trained networks, only to be discarded by the segmentation output and its entropy aggregation. Our findings expose a fundamental mismatch between the theoretical promise of aleatoric uncertainty and its practical behavior, and suggest that practitioners should not rely on entropy-based uncertainty as a proxy for clinical ambiguity in safety-critical applications.

0.34

Beyond Accuracy: Uncertainty-Guided Boundary Refinement for Reliable Biomedical Image Segmentation

cs.CV cs.LG ·2026-09-11 ·Anima Kujur
similarity 0.66
Abstract

Accurate biomedical image segmentation requires not only high global overlap but also reliable delineation of clinically meaningful boundaries. In blood-smear microscopy, cytoplasm and nucleus contours provide the structural basis for downstream morphology analysis; however, deep segmentation models may remain uncertain or overconfident near ambiguous boundary regions even when achieving strong Dice scores. This work proposes a Reliability-Aware Boundary Refinement Network (RABR-Net), a two-stage framework for trustworthy image segmentation. A strong UNet++ EfficientNet-B4 base segmenter first produces initial class probabilities and logits. Predictive entropy, test-time augmentation variance, margin uncertainty, probability gradients, and soft boundary cues are then combined into a boundary-aware reliability representation. This representation guides a gated residual refiner that selectively corrects uncertain boundary pixels while preserving confident regions of the base prediction. The framework is evaluated using overlap accuracy, class-wise Dice, Boundary Dice, HD95/ASSD, calibration, risk--coverage analysis, robustness under image perturbations, qualitative correction maps, and paired statistical testing. On the held-out test set, the proposed method improves Dice from 0.9602 to 0.9614, Boundary Dice from 0.3448 to 0.3611, and HD95 from 3.0354 to 2.8274 compared with the cached base prediction. Statistical analysis confirms significant improvements in Dice, Boundary Dice, and HD95. Qualitative results show that the learned gate concentrates around uncertain cytoplasm and nucleus boundaries, and correction maps confirm localized boundary refinement. Although calibration does not automatically improve after refinement, the proposed framework provides an interpretable and reliability-focused strategy for boundary-sensitive biomedical image segmentation.

0.22

Towards Trustworthy AI for Glioma Diagnosis: A Task-Aware Evaluation of Uncertainty Quantification

cs.CV cs.AI ·2026-09-30 ·Gonzalo Esteban Mosquera Rojas, Sebastian R. van der Voort, Carolin M. Pirkl, Sandeep Kaushik, Marion Smits +1 more
top venue similarity 0.66
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:033

Uncertainty Quantification (UQ) is a key requirement for trustworthy AI in high-stakes medical image analysis. In this work, we evaluate UQ in a multi-task Deep Learning framework for MRI-based glioma diagnosis that performs tumor segmentation and predicts IDH mutation status, 1p/19q co-deletion status, and tumor grade. Monte Carlo Dropout (MCD) is used for a detailed task-aware analysis of predictive, aleatoric, and epistemic uncertainty. We assess MC sample convergence, calibration, error detection, selective prediction, associations with segmentation performance, and the effect of voxel-wise uncertainty aggregation on case-level reliability. We also compare MCD with Deep Ensembles (DE) and Monte Carlo Deep Ensembles (MCDE), examine interactions between segmentation quality and classification, and evaluate a composite trust score integrating segmentation and classification uncertainty. Across tasks, uncertainty estimates supported meaningful error detection, while calibration depended on the dropout rate, with moderate rates yielding the most reliable probabilities. Uncertainty decomposition provided task-dependent interpretability but did not consistently improve error detection over predictive uncertainty alone. DE and MCDE showed comparable operational utility, with no method consistently dominating across tasks and metrics. The composite trust score did not consistently outperform classification uncertainty for selective prediction. Overall, our results provide a task-aware evaluation strategy and practical guidance for the development of trustworthy AI for glioma diagnosis.

0.41