Abstract

Assessment of the main pancreatic duct (MPD) from volumetric magnetic resonance cholangiopancreatography (MRCP) scans is an essential task for ductal dilatation diagnosis and pancreatic cancer analysis. However, manual assessment is affected by reader variability in which automated analysis may assist. Nevertheless, fully automated and uncertainty-aware MPD analysis from volumetric MRCP remains underexplored area of research. In this study, we propose an automatic and uncertainty-aware deep learning-based pipeline for MPD segmentation and maximum-width analysis from MRCP scans. A coarse localisation model first identifies the ductal region-of-interest, followed by a fine model that segments the MPD within the region. The dataset consists of 256 MPD-segmented MRCP scans from 69 patients. A randomly selected holdout test subset of 14 patients with 55 MRCP volumes was used for evaluation. We employed a five-model cross-validation ensemble for improved performance and uncertainty estimation. The best MPD segmentation performance was 0.634 DSC, 0.744 precision, and 0.593 recall. The mean absolute error for maximum MPD width prediction was 0.355~mm and dilated MPD ($\geq 5$~mm) was detected with 75.0\% sensitivity and 74.4\% specificity. These novel results suggest that automated MPD segmentation can be used to aid MRCP-based duct measurements.

Closest papers

Nearest neighbours by meaning across the whole index.

PCLSegNet: Anatomy-Aware Deep Learning Framework for MRI-based Pancreatic Cyst Segmentation and Size Assessment

cs.CV ·2026-11-11 ·Hanyi Zhang, Tongyu Wang, Manuel Debic, Markus Wennmann, Johannes Haubold +19 more
similarity 0.67
Abstract · 17 pages, 4 figures, 6 tables

Early detection and follow-up of pancreatic cystic lesions (PCLs) are crucial, as some of their subtypes, such as mucinous cystic neoplasms (MCNs) and intraductal papillary mucinous neoplasms, carry a significant risk of malignant transformation. Although most AI studies investigating PCLs rely on computed tomography (CT) scans, magnetic resonance imaging (MRI) offers superior soft tissue contrast, making it highly suitable for PCLs assessment. In this work, we propose an anatomy-aware two-stage deep learning framework for automated PCLs segmentation on abdominal MRI scans. First, a publicly available pancreas segmentation model is used to localize the pancreas. Then, we introduce the anatomyaware PCLSegNet, which incorporates anatomical priors as guidance for pancreas and PCLs segmentation. To address the class imbalance problem, we develop a Class-Specific ErrorWeighted (CSEW) loss function. Postprocessing is applied through anatomical constraints.Our proposed method outperforms multi-organ segmentation models such as TotalSegmentator, achieving substantially higher Dice scores for pancreas segmentation. Moreover, it also achieves a superior normalized surface Dice (NSD) and recall for PCLs segmentationcompared to other state-of-the-art models like nnU-Net, while also notably reducing the false negative rate, facilitating the automatic early detection and the noninvasive imaging-based assessment of PCLs.

0.21

Contrastive uncertainty learning for robust multi-structure segmentation in lower-pelvic MR

cs.CV cs.LG ·2026-10-14 ·Bilal Sidiqi, Yipei Wang, Wen Yan, Shaheer U. Saeed, Daniel C. Alexander +1 more
top venue similarity 0.67
Abstract · UNSURE MICCAI 2026

Boundary delineation of anatomical structures in prostate MRI is often compromised by regional ambiguity. Automated segmentation methods relying on global overlap loss functions tend to be insensitive to surface deviations, leading to significant errors in ambiguous regions. Most existing uncertainty-aware methods treat uncertainty as a post-hoc quality indicator or prediction filter. We propose Contrastive Uncertainty Learning (CUL), a supervised framework that uses predictive uncertainty to directly guide representation learning. Using Monte Carlo Dropout, CUL identifies voxel-wise uncertainty and structures the embedding geometry accordingly: low-uncertainty, correctly predicted features form stable voxels while high-uncertainty or misclassified features are actively repelled, preventing feature collapse at difficult boundaries. We evaluate CUL on a 589-scan 3D prostate MRI multi-structure segmentation task (8 anatomical structures) using a ViT with UperNet decoder architecture. Average Dice ($83.38\%$) remains comparable to the baseline ($83.35\%$), while surface distance decreases significantly ($p<0.001$) across 6 of 8 anatomical structures. A hard-case analysis reveals a $22{\times}$ asymmetry between significantly improved and degraded cases ($18.8\%$ vs $0.9\%$). Ablation studies show that removing uncertainty-guided sample selection eliminates improvements for the transition zone, while replacing the contrastive objective with a boundary loss additionally removes bladder improvements, demonstrating that both uncertainty-guided sampling and the contrastive objective are essential for the observed gains. These findings demonstrate that the proposed uncertainty-guided representation learning is a useful mechanism for reducing the risk of extreme errors in safety-critical medical segmentation

0.30

Segment Anything Pancreas: A Unified MRI Segmentation Model for Pancreatic Cancer Radiotherapy

cs.CV ·2026-10-29 ·Zach Eidex, Mojtaba Safari, Kundan Thind, Parag J. Parikh, Zhen Tian +1 more
similarity 0.64
Abstract

Background: Limited tumor annotations and incomplete labels across MRI datasets hinder unified segmentation of pancreatic tumors and organs at risk (OARs) for MRI-guided radiotherapy. Purpose: We propose Pancreas-MedNeXt, a unified model that segments the whole pancreas, its subregions, tumors, and surrounding OARs from one MRI volume. Methods: The model uses a shared MedNeXt encoder-decoder with supervised whole-pancreas and subregion pretraining, followed by multitask fine-tuning. Three output heads predict the pancreatic subregions, tumor, and OARs (stomach, duodenum, kidneys). An annotation-aware loss allows training on partially labeled data without treating unannotated structures as background. Pancreas and tumor were evaluated by three-fold cross-validation on 142 PANTHER patients (92 diagnostic, 50 MR-Linac), subregions and OARs on Cyst-X and AMOS test sets, and pancreas and OARs on 33 external T1-weighted TotalSegmentator scans. Comparisons with nnU-Net, MedNeXt, VISTA3D, and Swin UNETR used the Dice similarity coefficient (DSC) with paired bootstrap 95% CIs. Results: Pancreas-MedNeXt achieved the highest mean pancreas and tumor DSC on diagnostic and MR-Linac MRI. Tumor DSC was 58.41% and 42.55%, exceeding task-specific MedNeXt by 4.94 (95% CI: 0.28-9.45) and 5.89 (95% CI: 2.37-9.72) percentage points, respectively. Whole-pancreas DSC was 85.73% and 70.66%. Pretraining improved head, body, and tail DSC by 2.01, 3.00, and 3.78 percentage points over training from scratch. It also achieved the highest DSC for the pancreas, duodenum, and right kidney on AMOS, and for all five organs on external MRI, exceeding the next-best method by 4.92-8.85 percentage points.Conclusion: A single Pancreas-MedNeXt model segments tumors, pancreatic subregions, and OARs on diagnostic and MR-Linac MRI, which could streamline contouring for pancreatic cancer radiotherapy.

0.19

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

cs.CV physics.med-ph ·2026-09-02 ·Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling +9 more
similarity 0.64
Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

0.16

AMPLIFAI: A Multiphase CT Dataset for Benchmarking Clinical Reasoning in LI-RADS Assessment of Liver Lesions

cs.CV cs.LG ·2026-08-14 ·Pranav Kulkarni, Nikhil Shah, Amritansh Suryavanshi, Jana G. Delfino, James Tonascia +7 more
dataset similarity 0.63
Abstract · 15 pages, 6 figures, 3 tables

Hepatocellular carcinoma (HCC) is the third leading cause of cancer-related mortality worldwide, with early detection improving survival from <20% to >70%. The standardized Liver Imaging Reporting and Data System (LI-RADS) criteria provide an imaging-based diagnostic framework to evaluate liver lesions for HCC, serving as a foundation for automating HCC detection with artificial intelligence (AI). However, the lack of large, publicly available datasets with high-quality annotations has limited the development and evaluation of AI models for automated LI-RADS assessment. We introduce AMPLIFAI dataset, the first public dataset of 590 multiphase abdominal CT studies annotated with LI-RADS categories, lesion size, and voxel-level segmentations for three major LI-RADS features: arterial phase hyperenhancement, washout, and enhancing capsule. The dataset was curated and harmonized from four public datasets and augmented with expert annotations from five board-certified radiologists and one resident. Following the Datasheets for Datasets format, this paper details the dataset's composition, curation and harmonization process, and annotation workflow to support transparent, reproducible research in medical imaging AI.

0.10

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

eess.IV cs.CV ·2026-08-28 ·Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten +3 more
published similarity 0.63
Abstract · Accepted as a CaPTion workshop paper at MICCAI 2026

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $Δ$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

0.40

An interpretable deep learning method for early hepatocellular carcinoma diagnosis on multiphase CT

cs.CV cs.AI ·2026-10-21 ·Emma Sarfati, Alexandre Bône, Pietro Gori, Sisi Yang, Marc-Michel Rohé +6 more
publishedhot direction similarity 0.61
Abstract · Accepted at Scientific Reports

Early diagnosis of hepatocellular carcinoma is critical to preserve access to curative treatment options. The Liver Imaging Reporting and Data System (LI-RADS) provides a standardized framework for non-invasive diagnosis on multiphase computed tomography, based on major visual imaging features. However, these features may be difficult to assess consistently, particularly in small liver lesions. We developed dLI-RADS, an interpretable artificial intelligence method designed to estimate the probability of hepatocellular carcinoma from multiphase computed tomography images of manually segmented liver lesions, while remaining aligned with LI-RADS-related imaging concepts. dLI-RADS combines neural network-derived predictions with handcrafted quantitative imaging measurements reflecting LI-RADS major features and integrates these inputs using logistic regression. In this multicenter retrospective study, patients with multiphase computed tomography and at least one liver lesion were included, while lesions larger than 40 mm were excluded. Histology served as the reference standard for hepatocellular carcinoma, and a composite reference standard was used for non-hepatocellular carcinoma lesions. The lesion-level accuracy of dLI-RADS and LI-RADS were compared on the internal evaluation set using 10,000-repetition bootstrap non-inferiority tests, with 5% margins and significance levels. On the external test set, sensitivities were similarly compared. dLI-RADS was non-inferior to LI-RADS for lesion-level accuracy in the internal evaluation set, achieving 80% accuracy compared with 74% for LI-RADS (p = 0.04)...

0.29

Classification of Tissues on MALDI-MSI Image Modality for Pancreatic Cancer Studies

cs.CV ·2026-11-17 ·Abubakar Qahir, Jenny Benois-Pineau, Victoria Bourgeais, Fabien Baldacci, Sandrine Dabernat +4 more
similarity 0.61
Abstract

Mass Spectrometry Imaging (MSI) spatially maps molecular distributions in tissue sections. Despite the availability of preprocessing tools for MSI data, building end-to-end workflows suitable for deep learning remains challenging. We have developed a fully automated pipeline for transformation of raw Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry imaging (MALDI-MSI) data into deep-learning-ready image patches for binary pancreatic tissue classification (tumoral vs non-tumoral) and built individual models for recognition of tumoral regions in spectral images. Images resulting from the proposed pipeline and from reference interactive workflow are very close in terms of image quality metric mean squared error (MSE). The proposed pipeline computational time is of 20 min in average compared to a full working day of the reference interactive workflow. The models achieved 0.94 accuracy on high-resolution spectra and a mean accuracy of 0.59 on lower-resolution spectra.

0.26