CS Paper Radar

Patch-Based Diffusion Reconstruction for Accelerated Cardiac Cine

Xuan Lei, Philip Schniter, Juliet Varghese, Rizwan Ahmad

eess.IV eess.SP ·submitted 2026-08-28 22:55 UTC · v1

Abstract

Purpose: To develop and evaluate a diffusion-based reconstruction framework for highly accelerated 2D real-time (RT) cine cardiovascular magnetic resonance imaging (CMR). Methods: We trained an unconditional patch-based diffusion model and incorporated it into a reconstruction framework, termed CineDiff, using diffusion posterior sampling for data consistency. CineDiff was evaluated in four settings: (i) 30 retrospectively undersampled breath-held cine at 1.5T and 3T from healthy participants across multiple acceleration rates, (ii) 15 prospectively undersampled free-breathing RT cine at 1.5T and 3T from patients indicated for clinical CMR, and (iii) 10 prospectively undersampled mid-field (0.55T) free-breathing scans, including five from healthy subjects and five from porcine models. For retrospective undersampling, reconstruction quality was assessed using peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), learned perceptual image patch similarity (LPIPS), and deep image structure and texture similarity (DISTS). For prospective undersampling, image quality was evaluated by blinded expert scoring on a 5-point Likert scale. Results: In retrospectively undersampled breath-held cine data, CineDiff achieved higher PSNR and SSIM and lower LPIPS and DISTS than the comparison methods across all evaluated acceleration rates. In prospectively undersampled free-breathing RT cine data, CineDiff received higher expert image-quality scores. Qualitatively, CineDiff reduced block-like artifacts and preserved finer anatomical detail compared with traditional compressed sensing and a variational network method, termed CineVN. Conclusion: CineDiff enabled high-quality reconstruction of highly accelerated 2D RT cine CMR. The method also demonstrated robustness to out-of-distribution data, including mid-field and porcine acquisitions.

Closest papers

Nearest neighbours by meaning across the whole index.

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.65
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.16

Image-Condition-Controlled Diffusion Network with Large-Scale CT Pretraining for CT-Free Attenuation Correction in Dynamic Cardiac PET

cs.CV ·2026-11-18 ·Zhejia Zhang, Scott M. Leonard, Jinkui Hao, Ryan J. Avery, Richard L. Weinberg +1 more
similarity 0.65
Abstract · 11 pages, 6 figures, 3 tables. Submitted to IEEE Transactions on Radiation and Plasma Medical Sciences

Positron emission tomography (PET) provides quantitative information on myocardial perfusion. In dynamic PET, tracer kinetics are tracked through a series of reconstructed time frames. Reliable attenuation correction is essential for accurate measurements. Clinical attenuation maps ($μ$-maps) are typically derived from computed tomography (CT), which adds radiation exposure and may introduce PET-CT misregistration due to respiratory and cardiac motion. Moreover, supervised CT-free methods rely on paired non-attenuation-corrected (NAC) PET and CT data, which are scarce, whereas large-scale unpaired CT data are more readily available. To address these challenges, we propose Large-scale Unpaired CT-Informed Diffusion (LUCID), a framework that transfers anatomical priors learned from 10,000 chest CT volumes in the public CT-RATE dataset to $μ$-map synthesis for dynamic cardiac $^{82}$Rb PET. First, a convolutional neural network (CNN) predicts an initial $μ$-map from each NAC PET frame. Second, the CT-pretrained diffusion backbone refines a low-noise perturbation of the CNN prediction through a single denoising step, conditioned on the corresponding NAC PET frame via ControlNet. Finally, frame-wise predictions are averaged voxel-wise to obtain the final $μ$-map. We further introduce the voxel-wise temporal standard deviation (TSD) to quantify inter-frame variability without requiring a reference $μ$-map. We evaluated LUCID on an in-house dataset of 102 patients and found that it achieved the best quantitative accuracy while maintaining competitive inter-frame consistency. Ablation studies showed that refinement with a diffusion backbone pretrained on in-house CT data from the training patients was less accurate than the CNN prediction alone, highlighting the importance of large-scale CT pretraining.

0.22

Anatomy-Aligned Surface Field Learning for Myocardial Reconstruction from Sparse Short-Axis Cine MRI

cs.CV ·2026-09-24 ·Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
code/data similarity 0.63
Abstract · 12

Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis (SAX) cine MRI is sparsely sampled along the through-plane direction, making dense and anatomically consistent surface reconstruction challenging. In this study, we propose an anatomy-aligned surface learning framework that parameterizes the epicardial and endocardial surfaces on a shared circumferential-longitudinal UV domain. This formulation converts irregular 3D reconstruction into structured coordinate-field completion with explicit correspondence across subjects and cardiac phases. Sparse SAX contours are encoded as UV observation fields, coverage-aware sampling improves robustness to incomplete slice coverage, and topology- and distortion-aware learning preserves circumferential continuity and local surface quality. Experiments on three public cine MRI datasets showed that the proposed method consistently outperformed representative mesh-based and implicit reconstruction approaches, achieving overall Chamfer distances of $2.887$~mm on ACDC, $2.641$~mm on M\&Ms, and $2.810$~mm on M\&Ms-2. The reconstructed sequences also preserved ventricular function, with end-diastolic volume and ejection fraction errors of $3.3$~mL and $1.1 \%$, respectively. These results demonstrate that anatomy-aligned UV learning provides an accurate, efficient, and correspondence-aware representation for sparse cine MRI reconstruction and myocardial modeling. The source code will be available at https://github.com/yuan-xiaohan/SAX2MyoSurf.

0.23

FM-Recon: Exploring Foundation Model Features for Accelerated Cardiac Cine MRI Reconstruction

cs.CV cs.AI ·2026-11-16 ·Donghang Lyu, Marius Staring, Ruochen Gao, Jochen Keupp, Hildo J. Lamb +1 more
similarity 0.63
Abstract

Foundation models have demonstrated strong feature extraction capabilities across various medical imaging tasks, yet their potential for MRI reconstruction remains largely unexplored, particularly within unrolled reconstruction networks and under artifact-corrupted inputs. In this work, we explore whether and how features from pretrained foundation models can benefit accelerated cardiac cine MRI reconstruction. To this end, we propose FM-Recon, a framework that refines and integrates extracted features from frozen image encoder of foundation models into an unrolled reconstruction network. Through extensive experiments on the CMRxRecon2023 dataset, we systematically evaluate foundation model features across different reconstruction settings. Our results show that foundation models can extract informative representations from artifact-corrupted inputs and improve reconstruction performance, particularly at moderate acceleration factors. These findings demonstrate the potential of foundation model features for accelerated MRI reconstruction and provide insights into their effective integration into unrolled reconstruction networks.

0.09

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

eess.IV cs.CV ·2026-11-03 ·Tianyuan Wang, Kenan Niu, Stefano Stramigioli
similarity 0.62
Abstract · 10 pages, 5 figures, 2 tables

Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

0.12

Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI Reconstruction

cs.CV ·2026-10-06 ·Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
publishedcode/data similarity 0.61
Abstract · Accepted at ECCVW 2026

Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while preserving diagnostic fidelity. Recent reconstruction methods are typically trained from scratch and often require large amounts of task-specific data, limiting their robustness under data scarcity and distribution shifts. In this work, we investigate whether pretrained vision foundation models can serve as effective priors for accelerated cardiac MRI reconstruction. We propose a reconstruction framework that integrates frozen and parameter-efficiently adapted visual encoders, including CLIP, BiomedCLIP, and DINOv2, within a transformer-based reconstruction architecture. Extensive experiments on the CMRxRecon2023 and CMRxRecon2024 benchmarks demonstrate that pretrained representations consistently outperform a transformer trained from scratch across multiple acceleration factors. We further evaluate performance under limited supervision and cross-dataset transfer, showing that foundation models provide superior data efficiency and generalization. While frozen representations are particularly effective in extreme low-data regimes, Low-Rank Adaptation (LoRA) yields additional gains when moderate amounts of training data are available. Among the evaluated backbones, DINOv2 achieves the strongest overall performance. These findings highlight the potential of vision foundation models as robust and transferable priors for cardiac MRI reconstruction.

0.31

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.61
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-20 ·Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya
code/data similarity 0.60
Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

0.31