CS Paper Radar

Toward Vision Language Model-based Assessment of Clinical Quality and Usability of LGE-MR Images for Cardiac Ablation Planning

Bipasha Kundu, Abhishek Chaturvedi, Axel W. E. Wismueller, Richard Simon, Cristian A. Linte

eess.IV cs.CV ·submitted 2026-08-21 14:51 UTC · v1
benchmark

Abstract

LGE cardiac MRI is widely used for left atrial fibrosis assessment and ablation planning in atrial fibrillation patients as knowledge of fibrotic tissue regions identified from LGE-MRI is critical for catheter ablation. Often, poor quality images used during ablation planning can cause mis-localization of ablation targets, directly impacting procedure safety and outcome. The decision of whether a scan meets the minimum quality threshold for ablation planning is currently made informally by the reviewing radiologist and is not captured by any automated system, yet it is arguably the most safety-critical output of the image quality assessment (IQA) process. However, variations in image quality caused by noise, motion artifacts, and poor boundary definition significantly compromise the reliability of downstream segmentation and clinical decision-making tasks. Manual quality assessment by expert radiologists is subjective and difficult to scale, while existing automated methods produce scalar scores without interpretable clinical reasoning. In this work, we propose a two-stage vision language model (VLM) framework for clinically grounded image quality assessment of left atrial LGE-MRI. In the first stage, a fine-tuned VLM generates structured radiology-style quality reports predicting five radiologist-defined criteria: Noise, Motion Artifact, LA Boundary Accuracy, PV Region Accuracy, and Under-segmentation Severity. In the second stage, a GPT-based reasoning module maps the predicted quality and reports to a structured quality scores and binary clinical usability decision for ablation planning. We curate a dataset of 60 annotated image slice-text pairs from 20 patients and benchmark four state-of-the-art VLM architectures. InternVL2 achieves the highest criterion-level accuracy (Avg ACC=0.65, PLCC=0.79), while DeepSeek achieves perfect clinical usability agreement (Acc=1.00, kappa=1.00).

Closest papers

Nearest neighbours by meaning across the whole index.

M3-Score: Fidelity, Memorization and Coverage as Separate Axes for Evaluating Generative Radiology Image Models

cs.CV ·2026-09-27 ·Sathiyamohan Nishankar, Pubudu Sanjeewani, Asanka Perera
similarity 0.64
Abstract

Quantitative evaluation of generative models for radiology remains challenging. Clinically relevant structures are often small and infrequent, feature spaces learned from natural images may represent them poorly, and a single summary score cannot distinguish limited fidelity from limited diversity. This study proposes the Medical Multi-axis Maximum Mean Discrepancy score (M3-Score), an evaluation framework based on RadioDINO-s16, a frozen vision transformer pretrained on radiology images. M3-Score reports three complementary axes computed at pre-specified encoder depths: \emph{fidelity}, measured by an unbiased multi-bandwidth radial basis function (RBF) MMD$^2$ at the final block; \emph{memorization}, measured by nearest-neighbor distances at 75\% depth; and \emph{coverage}, defined as the fraction of real images with a generated neighbor within their $k$-nearest-neighbor radius at 33\% depth. Reference sets are sampled across subjects to limit the influence of correlated slices. On BraTS brain MRI, the fidelity axis ordered five comparison sets of increasing severity (Spearman $ρ= 1.00$), and a subject-disjoint real set yielded $\mathrm{MMD}^2 = 0$ (permutation $p = 1$). An unconditional denoising diffusion probabilistic model achieved $\mathrm{MMD}^2 = 0.073$ (95\% confidence interval $[0.071, 0.080]$) but covered only 38\% of the real distribution. Under progressive mode dropping, $k$-NN manifold recall increased at all twelve encoder blocks, whereas the proposed coverage estimator decreased monotonically ($ρ= -1.00$). RadioDINO-s16 features separated real brain MRI from generated samples with a ROC-AUC of 0.819, compared with 0.555 for InceptionV3 and 0.582 for CLIP. Across a twentyfold range of sample sizes, the mean M3 value varied by a factor of 1.05, compared with 2.52 for the Fréchet Inception Distance.

0.21

CMDiff: Left Atrial Scar Segmentation from 3D LGE MRI Using Conditional Mask Diffusion Model: A Feasibility Study

cs.CV ·2026-11-05 ·Jing Zhang, Bastien Bergere, Jonas Leite, Emilie Bollache, Mikaël Laredo +2 more
code/data similarity 0.58
Abstract · 15 pages, 3 figures, 4 tables

Late gadolinium enhancement (LGE) cardiac MRI enables non-invasive assessment of left atrial (LA) scar, an imaging marker associated with atrial fibrillation ablation outcome. However, automatic scar segmentation is hindered by low contrast, the thin atrial wall, scarce labels, and extreme class imbalance. Conditional diffusion offers iterative mask generation, but its suitability for sparse 3D LA scar segmentation remains unclear. To address this gap, we propose Conditional Mask Diffusion (CMDiff), which predicts clean masks using a dynamic-encoder-conditioned 3D sinusoidal UNet. We compared CMDiff with a deterministic baseline on identical cases in five-fold cross-validation of 60 scar-labelled public LASCARQS subjects, with 48 training and 12 held-out cases per fold. CMDiff achieved a scar DSC of 0.47 $\pm$ 0.08, HD95 of 12.89 $\pm$ 6.39 mm, and ASD of 1.91 $\pm$ 0.96 mm, compared with deterministic baseline values of 0.51 $\pm$ 0.08, 10.86 $\pm$ 5.39 mm, and 1.58 $\pm$ 1.03 mm, respectively. Under the same implementation, clean-mask prediction performed substantially better than the noise-prediction configuration evaluated in this study. Thus, CMDiff was technically feasible but did not improve segmentation performance: DSC was lower, and both HD95 and ASD were higher. Direct mask diffusion therefore provides an analytical alternative, but not a competitive performance advance for this task. The source code is publicly available at https://github.com/jizhang02/CMDiff.

0.42

Zero-shot evaluation of open vision-language models as System 1 decision models on radiology tasks

cs.CV cs.AI ·2026-11-01 ·Bradley J Erickson, Sara Salehi
similarity 0.58
Abstract · 22 pages, 3 tables, 2 figures

Purpose: We compared two multimodal System 1 decision models, Clef 27B and d1 3B, with a traditional LLM (Qwen 3.8-27B) on seven radiology tasks covering text, radiographs, CT and MRI. Methods: Three models were compared: Clef, Qwen3.8-27B and d1. Three tasks were interpretation of text and 4 were detection of finding in images. The tasks were: 1. finding presence of finding in CT-RATE chest CT reports; 2. Presence of finding in PadChest chest radiograph reports; 3. the same 18 findings on CT-RATE chest CT but 3D volumes; 4. MR safety status of devices from AccessGUDID device records; 5. line and tube position on RANZCR CLiP chest radiographs; 6. motion-artifact severity on MR-ART T1-weighted brain MRI and 7. sequence identification on BraTS 2021 brain MRI. The primary endpoint was AUROC. There was no fine-tuning of the models on the tasks. Results: All models completed all tests without a failed request. All retrieved findings from reports almost perfectly (AUROC >0.95). Clef ranked higher than its Qwen backbone on CT-RATE volumes and RANZCR lower on MR-ART. The two did not differ on BraTS, GUDID or PadChest, and differed by 0.002 on CT-RATE reports. On BraTS, Clef correctly identified 90 of 100 FLAIR volumes while Qwen never chose it. d1 ranked lower than Clef on six of seven tasks. No model performed well on motion severity. Clef was faster per request than Qwen on tasks with many questions per input. d1 used 3 to 9 times less energy per request than Clef. Conclusions: System 1 models can perform important tasks in radiology with high accuracy, at lower compute cost than LLMs used in the usual way. When an LLM is constrained to a single answer token, its cost and performance is similar to System 1 models unless multiple questions are asked. A 3B System 1 model was close to the 27B models on report text but not on images. No model performed well on motion severity.

0.25

ProGeo-RC: Prototype-guided Semantic Reliability and Geometric Error Calibration for Semi-supervised Cardiac Image Segmentation

cs.CV ·2026-11-03 ·Yunfei Zhu, Wenfeng Zhang, Pan Zeng, Xin Huang, Tao Jia +3 more
published similarity 0.57
Abstract · Accepted at IEEE BIBM 2026. 7 pages, 3 figures

Semi-supervised medical image segmentation aims to train reliable segmentation models using limited labeled data and abundant unlabeled data. However, existing methods typically rely on prediction confidence or model consistency to estimate pseudo-label reliability, but these criteria are insufficient to characterize both semantic reliability and geometric plausibility. To address this issue, we propose ProGeo-RC, a prototype-guided semantic reliability and geometric error calibration framework for semi-supervised medical image segmentation. ProGeo-RC consists of two key modules: Prototype-guided Semantic Reliability Estimation (PSRE) and Structured Semantic-Geometric Error Calibration (S-SGEC). PSRE uses probabilistic class prototypes to estimate the semantic reliability of unlabeled predictions and calibrate pixel-wise teacher pseudo labels, while S-SGEC introduces signed-distance-field-based geometric constraints to refine ambiguous boundaries and suppress spurious foreground responses outside target structures. Experiments on the ACDC and MVAA-CT datasets show that ProGeo-RC achieves better performance compared with representative semi-supervised segmentation methods. Under the 10\% labeled setting on ACDC, ProGeo-RC improves DSC and Jaccard by 0.37\% and 0.49\% over the corresponding second-best results, while reducing 95HD and ASD by 0.61 and 0.21, respectively. These results indicate that joint semantic reliability estimation and geometric error calibration can provide more reliable pseudo supervision for semi-supervised medical image segmentation.

0.32

Improving Cross-Site Whole-Heart Segmentation

eess.IV cs.CV ·2026-08-25 ·Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao +2 more
publishedcode/data similarity 0.57
Abstract · 12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

0.51

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

cs.CV cs.LGeess.IV ·2026-11-03 ·Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria
code/data similarity 0.57
Abstract · 21 pages, 5 figures, 1 table, 6 Extended Data figures and 4 Extended Data tables. Code: https://github.com/aashish-chapagai/CXR-Saliency-Ext…

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

0.31

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

eess.IV cs.AIcs.CV ·2026-11-13 ·João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós
published similarity 0.57
Abstract · 9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challeng…

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

0.37

CineMR: Tool-Integrated Vision-Language Reasoning for Quantitative Cardiac MRI Assessment

cs.CV cs.AI ·2026-10-01 ·Kunyang Li, Hai Nguyen, Joshua Lowe, Chenguang Zhao, Peace C. Madueme +4 more
benchmarkcode/datahighly cited similarity 0.56
Abstract · Code, benchmark resources, and model weights are available at https://github.com/AI-MIND-Lab/CineMR

Cardiovascular magnetic resonance (CMR), including cine imaging, is a reference standard for the noninvasive assessment of cardiac morphology and ventricular function. Cine CMR interpretation integrates qualitative visual assessment with quantitative measurements of ventricular volumes, ejection fraction, myocardial mass, wall thickness, and regional wall motion. Current medical vision-language models (VLMs) cannot reliably derive quantitative measurements from multidimensional cine images without analysis tools. We present CineMR, a tool-augmented VLM that invokes cardiac image-analysis tools and integrates their outputs into interleaved reasoning for quantitative CMR assessment. We also construct a multi-cohort visual question answering benchmark covering quantitative metric extraction, multiclass diagnosis, and differential diagnosis, together with tools for segmentation, phase selection, volumetry, morphometry, and regional wall motion analysis. CineMR is trained with supervised fine-tuning (SFT) on tool-interaction traces followed by Group Relative Policy Optimization (GRPO) with conditional tool-use rewards. On the multi-cohort cine CMR benchmark, CineMR achieves 35.9% pass@1 and 58.9% pass@4, compared with 1.5% pass@1 for the Qwen3-VL-8B backbone and 0.0% and 7.0% pass@1 for LLaVA-Med v1.5 and MedGemma-4B, respectively. Correct tool invocation reaches 99.8% after GRPO, up from 78.9% after SFT. Live tool outputs improve ventricular measurement accuracy by 20.4--23.7% over direct model predictions, and removing all tools reduces pass@1 from 35.9% to 27.9%. These results highlight the importance of reliable tool use for quantitative cine CMR reasoning and support CineMR as a promising approach for assistive cardiac image assessment. Code, benchmark resources, and model weights are available at https://github.com/AI-MIND-Lab/CineMR.

0.56