CS Paper Radar

Anguinus Sculpturae: Compositional Synthesis of Peak-Enhancement Breast DCE-MRI Scans

Benjamin Hamm, Nico Albert Disch, Maximilian Rokuss, Yannick Kirchhoff, Constantin Ulrich, Klaus Maier-Hein

cs.CV ·submitted 2026-09-27 14:27 UTC · v1
publishedcode/data

Abstract

Dynamic contrast-enhanced breast MRI (DCE-MRI) is rich in anatomical and perfusion information, but its reliance on gadolinium-based contrast agents raises safety concerns and adds cost. Virtual contrast enhancement, synthesizing post-contrast from pre-contrast images, is a promising alternative. We address the MAMA-SYNTH challenge task of predicting peak-enhancement breast MRI. Rather than adopting the full machinery of diffusion or flow matching, we observe that under a rectified, straight-line path the generative process collapses to a single difference prediction: the synthetic peak image is the pre-contrast image plus a predicted enhancement map, recovered in one forward pass. Around this we build Anguinus Sculpturae, a compositional pipeline in which nnU-Net segmentations of lesion, foreground and breast region guide two generators - one optimized for global fidelity, one for lesion structure through an asymmetric Tversky term routed via a frozen segmenter - composited region-wise with Gaussian-weighted blending. On the held-out Duke subset of MAMA-MIA our model achieves the best FRD and Dice among all evaluated variants, showing that single-step difference prediction with segmentation guidance suffices to recover both global fidelity and lesion structure. Code is available at https://github.com/MIC-DKFZ/AnguinusSculpturae.

Comment
Accepted as an oral at the MAMA-SYNTH 2026 challenge / Deep-BreAth 2026 Workshop, MICCAI 2026. 12 pages, 3 figures, 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

Lesion-Gated Hybrid Synthesis for Virtual Contrast-Enhanced Breast MRI: A MAMA-SYNTH Challenge Solution

eess.IV cs.CV ·2026-09-18 ·Shohei Yoshimoto
benchmark similarity 0.80
Abstract · 8 pages, 2 figures, 3 tables. MAMA-SYNTH Challenge solution report; the submitted method ranked 6th in the official challenge leaderboard

Purpose: Contrast-enhanced breast MRI depends on intravenous gadolinium-based contrast agents, motivating methods that synthesise post-contrast appearance from pre-contrast images alone. The MAMA-SYNTH Challenge (MICCAI 2026 Deep-Breath Workshop) evaluates such synthesis across four metric groups: image fidelity, tumour region of interest, downstream classification, and downstream segmentation. The four group ranks are averaged, so optimising a single objective is insufficient. Materials and Methods: We developed a lesion-gated hybrid synthesis pipeline. A lesion probability map, estimated from the pre-contrast slice alone by an ensemble of pre-contrast-only segmentation networks, spatially coordinates a tumour-focused regression pathway and a background-focused Pix2PixHD synthesis pathway, followed by a region-dependent calibration of the predicted enhancement. Training used the public MAMA-MIA collection with a patient-level split. Inference consumes a single pre-contrast 2D slice, with no mask, no post-contrast image, and no auxiliary metadata beyond image geometry. Results: On internal validation (n = 120 patients) the method reached MSE 0.523, LPIPS 0.185, and tumour-region SSIM 0.495. It was submitted to the hidden external 300-case test cohort as a self-contained inference container. The method ranked sixth in the official MAMA-SYNTH Challenge leaderboard. Conclusion: A test-compatible lesion probability map derived from the pre-contrast image can coordinate complementary tumour-focused regression and background-focused perceptual synthesis, enabling balanced virtual contrast enhancement under a multi-metric challenge setting.

0.20

MAMA-FLUX.2: Image-to-Image Synthesis of Post-Contrast Breast DCE-MRI for the MAMA-SYNTH Challenge

cs.CV ·2026-08-26 ·Kamil Kwarciak, Marek Wodzinski
similarity 0.72
Abstract · 9 pages, 3 figures, 1 table

Dynamic contrast-enhanced breast MRI is central to cancer diagnosis and monitoring, but requires gadolinium-based contrast agents. In this work, we address pre-to-post contrast breast MRI synthesis for the MAMA-SYNTH challenge. We propose MAMA-FLUX.2, a conditional latent flow-matching approach based on FLUX.2-Klein-4B. The pre-contrast image is encoded as spatial conditioning, while the model predicts the flow field associated with the post-contrast target latent. To adapt the pretrained model efficiently, we use LoRA fine-tuning and introduce a regional training objective combining global flow matching, tumor-region supervision, and stable foreground regularization. We further investigate LoRA rank, intensity windowing, and regional loss weights on axial slices, prioritizing clinically relevant tumor-focused metrics. Our ablation study shows that moderate tumor and stable-foreground weighting improves the trade-off between image fidelity and tumor-region accuracy. The final model achieves the best overall balance with LoRA rank/$α=64/64$, $\mathrm{MHA}_{\max}=25$, $λ_{\mathrm{tumor}}=0.25$, and $λ_{\mathrm{stable}}=0.1$. These results demonstrate that compact pretrained rectified-flow transformers can be adapted for contrast-enhanced MRI synthesis using parameter-efficient fine-tuning and task-aware regional losses.

0.29

Anatomy-Aware Synthesis of Post-Contrast Breast MRI from Pre-Contrast Images

cs.CV ·2026-09-22 ·Zhengbo Zhou, Dooman Arefan, Lin Gu, Ufara Zuwasti Curran, Shandong Wu
similarity 0.70
Abstract

We developed an anatomy-aware deep learning framework to synthesize post-contrast breast MRI from pre-contrast images, emphasizing tumor and background parenchymal enhancement (BPE) regions. This retrospective study included 649 patients with 6,251 paired pre-contrast and post-contrast images. The framework integrates breast mask consistency, lesion-region supervision, and BPE-region supervision into an image-to-image translation model. Evaluation included quantitative image quality metrics, a reader study with two breast radiologists, and downstream Ki-67 classification. The proposed method outperformed Pix2Pix, Pix2PixHD, diffusion-based synthesis, and mask-supervised baselines in whole-image and regional evaluations. Ki-67 classification showed no statistically significant performance differences across real- and synthetic-image training and testing settings, although this does not establish equivalence. These findings suggest that anatomy-aware supervision improves synthesis fidelity and support further investigation of synthetic post-contrast MRI for contrast-free imaging workflows.

0.13

CAPS: Clinically-Verifiable Anatomy-Prioritized Synthesis for Missing MRI Imputation in Brain Tumor Segmentation

eess.IV cs.CV ·2026-10-20 ·Cecilia Diana-Albelda, Arthur Longuefosse, Mario Rubén Paz Campos, Álvaro García-Martín, Jesus Bescos
similarity 0.67
Abstract · 20 pages, 6 figures, 8 tables. Cecilia Diana-Albelda and Arthur Longuefosse contributed equally

Multi-parametric MRI is the gold standard for neuro-oncology, yet acquiring complete 4-modality protocols may be unfeasible in real-world clinical practice. When handling missing modalities, existing automated systems force a critical compromise: robust segmenters operate as uninterpretable "black boxes" that bypass image generation, while standard synthesis models often produce blurry reconstructions lacking diagnostic reliability. To address this issue, we propose CAPS, a Clinically-Verifiable Anatomy-Prioritized Synthesis framework that reconciles computational precision with clinical transparency. Our multi-modal generative architecture is driven by a hybrid objective function (L_1 + L_AFP + L_DualDice) that explicitly enforces the preservation of deep anatomical features and strict topological boundaries, rather than relying solely on pixel-wise optimization. Evaluated comprehensively on the BraTS Adult Glioma dataset, the framework achieves superior synthesis fidelity across intensity-based metrics, and demonstrates robust downstream segmentation performance (82.38% mean Dice), successfully restoring verifiable visual context. Furthermore, the framework exhibits exceptional zero-shot cross-domain generalization, maintaining high structural fidelity across completely unseen Meningioma, Pediatric, and Sub-Saharan African cohorts without domain-specific adaptation. Finally, a blinded radiological assessment confirms that our anatomy-aware approach significantly enhances both perceived image quality and clinical utility, providing clinicians with the reliable visual evidence required to trust downstream automated workflows.

0.20

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-20 ·Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya
code/data similarity 0.65
Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

0.31

3D Diffusion Models for Medical Imaging

cs.CV ·2026-10-19 ·Frank-Peter Schilling, Daniel Barco, Philipp Denzel, Marc Stadelmann
publishedsurvey similarity 0.65
Abstract · 27 pages, accepted for publication in Informatics in Medicine Unlocked

Generative deep learning methods such as Variational Autoencoders, Generative Adversarial Networks or Diffusion Models have achieved remarkable results in image synthesis. In particular, Diffusion Models have demonstrated superior image fidelity and sample diversity compared to other approaches on standard benchmarks, while also offering more flexible training dynamics as evidenced both in natural image domains and in medical applications. In medical imaging including Computed Tomography, Magnetic Resonance Imaging or Positron Emission Tomography, such models have various important use-cases including data augmentation, domain transfer, image reconstruction, inpainting, image augmentation and artifact correction. Further, generated images can be conditioned on patient characteristics, medical reports, segmentation masks or other images. Specific challenges arise due to the 3D volumetric nature of medical images, which translate to substantial demands in terms of memory, compute, and training data. This article provides a comparative overview of 3D Diffusion Models which have been developed for medical images, with a focus on current performance, limitations, and an outlook for future work.

0.23

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.64
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23

Mixture of Multi-Sequence Feature Difference for Contrast-Enhanced MRI Synthesis

cs.CV ·2026-10-15 ·Jonghun Kim, Junmo Kwon, Hyunjin Park
similarity 0.64
Abstract · ACCV 2026

Contrast-enhanced magnetic resonance imaging (CE-MRI) is crucial for accurately diagnosing and segmenting brain tumors. However, the acquisition of CE-MRI requires injecting contrast agents, which poses potential health risks and increases scan costs. Here, we propose a CE-MRI synthesis method from non-contrast sequences, reducing both risk and cost. Unlike existing methods that rely on channel-wise concatenation to fuse multi-sequence information for synthesis, we introduce a Mixture of Feature Difference (MoFD) module. The proposed module uses a dynamic weighting strategy to adaptively select and aggregate informative features from both individual source sequences and explicit differences among them. Quantitative and qualitative evaluations demonstrate that our proposed method outperforms baselines in terms of image fidelity and perceptual quality on the UCSF-PDGM and UPenn-GBM datasets. Our method successfully reconstructs tumor regions and achieves segmentation performance comparable to that obtained with real CE-MRI. Our ablation studies show that although adversarial learning improves perceptual quality, a regression-based variant of our method achieves higher structural fidelity.

0.24