CS Paper Radar

Anatomy-Aware Synthesis of Post-Contrast Breast MRI from Pre-Contrast Images

Zhengbo Zhou, Dooman Arefan, Lin Gu, Ufara Zuwasti Curran, Shandong Wu

cs.CV ·submitted 2026-09-22 19:57 UTC · v1

Abstract

We developed an anatomy-aware deep learning framework to synthesize post-contrast breast MRI from pre-contrast images, emphasizing tumor and background parenchymal enhancement (BPE) regions. This retrospective study included 649 patients with 6,251 paired pre-contrast and post-contrast images. The framework integrates breast mask consistency, lesion-region supervision, and BPE-region supervision into an image-to-image translation model. Evaluation included quantitative image quality metrics, a reader study with two breast radiologists, and downstream Ki-67 classification. The proposed method outperformed Pix2Pix, Pix2PixHD, diffusion-based synthesis, and mask-supervised baselines in whole-image and regional evaluations. Ki-67 classification showed no statistically significant performance differences across real- and synthetic-image training and testing settings, although this does not establish equivalence. These findings suggest that anatomy-aware supervision improves synthesis fidelity and support further investigation of synthetic post-contrast MRI for contrast-free imaging workflows.

Closest papers

Nearest neighbours by meaning across the whole index.

Lesion-Gated Hybrid Synthesis for Virtual Contrast-Enhanced Breast MRI: A MAMA-SYNTH Challenge Solution

eess.IV cs.CV ·2026-09-18 ·Shohei Yoshimoto
benchmark similarity 0.81
Abstract · 8 pages, 2 figures, 3 tables. MAMA-SYNTH Challenge solution report; the submitted method ranked 6th in the official challenge leaderboard

Purpose: Contrast-enhanced breast MRI depends on intravenous gadolinium-based contrast agents, motivating methods that synthesise post-contrast appearance from pre-contrast images alone. The MAMA-SYNTH Challenge (MICCAI 2026 Deep-Breath Workshop) evaluates such synthesis across four metric groups: image fidelity, tumour region of interest, downstream classification, and downstream segmentation. The four group ranks are averaged, so optimising a single objective is insufficient. Materials and Methods: We developed a lesion-gated hybrid synthesis pipeline. A lesion probability map, estimated from the pre-contrast slice alone by an ensemble of pre-contrast-only segmentation networks, spatially coordinates a tumour-focused regression pathway and a background-focused Pix2PixHD synthesis pathway, followed by a region-dependent calibration of the predicted enhancement. Training used the public MAMA-MIA collection with a patient-level split. Inference consumes a single pre-contrast 2D slice, with no mask, no post-contrast image, and no auxiliary metadata beyond image geometry. Results: On internal validation (n = 120 patients) the method reached MSE 0.523, LPIPS 0.185, and tumour-region SSIM 0.495. It was submitted to the hidden external 300-case test cohort as a self-contained inference container. The method ranked sixth in the official MAMA-SYNTH Challenge leaderboard. Conclusion: A test-compatible lesion probability map derived from the pre-contrast image can coordinate complementary tumour-focused regression and background-focused perceptual synthesis, enabling balanced virtual contrast enhancement under a multi-metric challenge setting.

0.20

MAMA-FLUX.2: Image-to-Image Synthesis of Post-Contrast Breast DCE-MRI for the MAMA-SYNTH Challenge

cs.CV ·2026-08-26 ·Kamil Kwarciak, Marek Wodzinski
similarity 0.72
Abstract · 9 pages, 3 figures, 1 table

Dynamic contrast-enhanced breast MRI is central to cancer diagnosis and monitoring, but requires gadolinium-based contrast agents. In this work, we address pre-to-post contrast breast MRI synthesis for the MAMA-SYNTH challenge. We propose MAMA-FLUX.2, a conditional latent flow-matching approach based on FLUX.2-Klein-4B. The pre-contrast image is encoded as spatial conditioning, while the model predicts the flow field associated with the post-contrast target latent. To adapt the pretrained model efficiently, we use LoRA fine-tuning and introduce a regional training objective combining global flow matching, tumor-region supervision, and stable foreground regularization. We further investigate LoRA rank, intensity windowing, and regional loss weights on axial slices, prioritizing clinically relevant tumor-focused metrics. Our ablation study shows that moderate tumor and stable-foreground weighting improves the trade-off between image fidelity and tumor-region accuracy. The final model achieves the best overall balance with LoRA rank/$α=64/64$, $\mathrm{MHA}_{\max}=25$, $λ_{\mathrm{tumor}}=0.25$, and $λ_{\mathrm{stable}}=0.1$. These results demonstrate that compact pretrained rectified-flow transformers can be adapted for contrast-enhanced MRI synthesis using parameter-efficient fine-tuning and task-aware regional losses.

0.29

Anguinus Sculpturae: Compositional Synthesis of Peak-Enhancement Breast DCE-MRI Scans

cs.CV ·2026-09-27 ·Benjamin Hamm, Nico Albert Disch, Maximilian Rokuss, Yannick Kirchhoff, Constantin Ulrich +1 more
publishedcode/data similarity 0.70
Abstract · Accepted as an oral at the MAMA-SYNTH 2026 challenge / Deep-BreAth 2026 Workshop, MICCAI 2026. 12 pages, 3 figures, 1 table

Dynamic contrast-enhanced breast MRI (DCE-MRI) is rich in anatomical and perfusion information, but its reliance on gadolinium-based contrast agents raises safety concerns and adds cost. Virtual contrast enhancement, synthesizing post-contrast from pre-contrast images, is a promising alternative. We address the MAMA-SYNTH challenge task of predicting peak-enhancement breast MRI. Rather than adopting the full machinery of diffusion or flow matching, we observe that under a rectified, straight-line path the generative process collapses to a single difference prediction: the synthetic peak image is the pre-contrast image plus a predicted enhancement map, recovered in one forward pass. Around this we build Anguinus Sculpturae, a compositional pipeline in which nnU-Net segmentations of lesion, foreground and breast region guide two generators - one optimized for global fidelity, one for lesion structure through an asymmetric Tversky term routed via a frozen segmenter - composited region-wise with Gaussian-weighted blending. On the held-out Duke subset of MAMA-MIA our model achieves the best FRD and Dice among all evaluated variants, showing that single-step difference prediction with segmentation guidance suffices to recover both global fidelity and lesion structure. Code is available at https://github.com/MIC-DKFZ/AnguinusSculpturae.

0.31

Frequency-consistent synthesis and selective transfer for medical image analysis

eess.IV cs.CV ·2026-11-06 ·Zhuhui Wang, Jianwei Zuo, Xin Peng, Kai Zhong, Xuliang Deng +1 more
similarity 0.66
Abstract · 40 pages, 5 figures

Complementary imaging is not always available, and realistic synthesis does not necessarily improve downstream analysis. Here we introduce a training framework linking medical image synthesis to task learning through adaptive frequency consistency and selective feature transfer. Image-specific frequency constraints encourage consistency of structure and detail. Features are transferred only when a teacher using synthetic images achieves a lower task-error score than the student by a task-specific margin on a labelled training sample. Evaluations across five datasets show improved translation fidelity with three adversarial and diffusion-based translators trained without paired supervision, alongside gains in brain-tumour segmentation on tumour-containing slices and lesion centre-point detection. All 105 reported paired comparisons yielded point estimates favouring the proposed methods, including 36 external translation comparisons on post?treatment MRI without retraining. These findings support synthetic modalities as task-oriented complements to acquired scans when complementary imaging is unavailable.

0.24

Evaluating ADC-only deep learning pipelines for breast cancer detection and segmentation using standalone diffusion-weighted MRI

cs.CV cs.AI ·2026-08-18 ·Pablo García Marcos, Paula Puerta Gonzĺez, Guillermo Lorenzo, Héctor Gómez, Covadonga del Camino +2 more
similarity 0.64
Abstract

Dynamic contrast-enhanced (DCE) imaging is the gold standard technique for the detection and characterization of breast cancer using magnetic resonance imaging (MRI). However, DCE-MRI requires long acquisition times and the administration of contrast into the bloodstream, which can cause allergic reactions. Alternatively, diffusion-weighted MRI (DW-MRI) is a standard complementary technique for breast MRI that does not require contrast, has shorter acquisition times, and enables calculation of apparent diffusion coefficient (ADC) maps that correlate with tumor cellularity. Yet, despite these technical advantages, deep learning research has focused on DCE-based models and has barely explored the tumor detection performance of DW-MRI and ADC maps either in combination with DCE-MRI or as standalone alternatives. Here, we evaluate the application of different state-of-the-art deep learning techniques for detection and segmentation of breast cancer using ADC-only images. This is, to our knowledge, the first comprehensive evaluation of ADC-only breast cancer pipelines for classification, detection, and segmentation tasks.

0.26

Mixture of Multi-Sequence Feature Difference for Contrast-Enhanced MRI Synthesis

cs.CV ·2026-10-15 ·Jonghun Kim, Junmo Kwon, Hyunjin Park
similarity 0.64
Abstract · ACCV 2026

Contrast-enhanced magnetic resonance imaging (CE-MRI) is crucial for accurately diagnosing and segmenting brain tumors. However, the acquisition of CE-MRI requires injecting contrast agents, which poses potential health risks and increases scan costs. Here, we propose a CE-MRI synthesis method from non-contrast sequences, reducing both risk and cost. Unlike existing methods that rely on channel-wise concatenation to fuse multi-sequence information for synthesis, we introduce a Mixture of Feature Difference (MoFD) module. The proposed module uses a dynamic weighting strategy to adaptively select and aggregate informative features from both individual source sequences and explicit differences among them. Quantitative and qualitative evaluations demonstrate that our proposed method outperforms baselines in terms of image fidelity and perceptual quality on the UCSF-PDGM and UPenn-GBM datasets. Our method successfully reconstructs tumor regions and achieves segmentation performance comparable to that obtained with real CE-MRI. Our ablation studies show that although adversarial learning improves perceptual quality, a regression-based variant of our method achieves higher structural fidelity.

0.24

Toward Contrast-Free Breast MRI: Improving Cancer Detection With Virtual Contrast Enhanced Imaging

eess.IV cs.CV ·2026-10-29 ·Hongxi Chen, Sunwoo Kwak, Sanyukta Adap, Katerina Dodelzon, Paula Feldman +1 more
similarity 0.63
Abstract · 5 pages, 2 figures, 1 table. Submitted to ISBI 2027

Although contrast-enhanced (CE) breast MRI is an important tool for cancer detection, intravenous gadolinium administration introduces additional considerations for patients and clinical workflows. AI based virtual contrast enhanced (VCE) MRI could help identify patients for whom acquired CE imaging may be avoidable without compromising diagnostic performance. We developed a framework that combines non contrast (NC) and VCE MRI predictions for cancer detection. On the held-out test set, cancer detection using NC MRI alone achieved an AUROC of 0.865. Combining the predictions from NC and VCE MRI improved AUROC to 0.901. Building on this complementary predictive value, we evaluated patient-level routing to progressively replace acquired CE examinations with the NC plus VCE pathway, prioritizing patients with the most confident NC predictions. This simulation suggests that diagnostic performance can be largely preserved while limiting acquired CE imaging to approximately 40% of patients. Together, these findings demonstrate the complementary value of VCE MRI and suggest its potential to support selective contrast use in breast cancer screening.

0.22

Reading the Mask: Descriptor-Grounded BI-RADS Rationale Generation for Breast MRI Segmentation

cs.CV cs.AI ·2026-10-21 ·Hrishikesh Singh, Aarti Sharma, Divyanshu Kumar, Millie Pant
similarity 0.63
Abstract

Deep learning based models accurately delineate tumours on dynamic contrast-enhanced MRI (DCE-MRI), but segmentation masks alone do not provide the rationales or reasoning used by radiologists to assess the lesion suspicion. This limits the explainability as well the clinical integration. We investigate whether clinically relevant descriptors can instead be derived from the segmentation masks and their dynamic contrast-enhancement series. We have used Breast Imaging Reporting and Data System (BI-RADS) guidelines as a structured framework. Using these guidelines we designed a BI-RADS decision tree with eight quantitative measurements using radiomics, together with the lesion size and component count, that determine the descriptors at eight nodes. Using these descriptors we generate natural-language rationale using a large language model. The model was constrained to express only the derived records from the decision tree. After applying this framework to the expert and automatic masks of each of the 1,506 cases in the MAMA-MIA dataset, we generated a reproducible corpus of 3,012 BI-RADS grounded rationales. We obtained a faithfulness score of 99.98% and a counterfactual accuracy of 99.3%, indicating that the generated rationales faithfully verbalises the measured descriptors and correctly reflects changes in the underlying record. Agreement between the descriptors from expert and automatic masks falls from 0.832 to 0.549 as mask quality falls from Good to Missed. The generated rationales are intended as draft representations for radiologist review and final sign-off rather than autonomous clinical reports.

0.13