CS Paper Radar

HealMed: Multilingual Evaluation of Large Language Models in Medicine

Yingjian Chen, Fan Gao, Sherry T. Tong, Haoyu Zhang, Aosong Feng, Kevin W. Jin, Xing Wu, Jinghui Lu, Abdul Samad, Akbar Faruqi, Cesar Caraballo, Cibele Brandão, Dhruva, Gupta, Eunji Jeon, Gabriel Madera-Santiago, Geon Lee, Hugo Toshio Itikawa, Insook Cho, Isabelli Martins, Isarar Siddique, Israr Ahmed, Jihyo Kwak, Kanyakorn Veerakanjana, Luis Guilherme Cardoso, Minjin Kim, Piyalitt Ittichaiwong, Renee Dua, Santiago Gudiño-Rosales, Xiujie Chen, Zeo Lapalus, Zixin Xu, Michihiro Yasunaga, Rex Ying, Heuiseok Lim, Jaewoo Kang, Chanjun Park, Hang Jiang, Ethan Goh, Hyunjae Kim, Edison Marrese-Taylor, Yusuke Iwasawa, Yutaka Matsuo, Qingyu Chen, Irene Li

cs.CL ·submitted 2026-08-20 12:52 UTC · v1
benchmarkcode/data

Abstract

We present HealMed, an expert-reviewed benchmark for multilingual evaluation of large language models in medicine. HealMed contains 1,000 examples in each of nine languages, drawn from nine datasets and covering three task formats: MCQA, NLI and open-ended QA. The benchmark was developed over two years by 23 physicians and medical experts based across nine countries and regions. Each translation was evaluated and revised by two experts fluent in English and the corresponding target language. On HealMed, performance declined most in low-resource languages, although the size of the gap varied markedly across languages and models. The strongest proprietary models were the most stable across languages, whereas many open-source and medically specialized models showed larger and less consistent gaps. Medical specialization alone did not ensure multilingual robustness. Furthermore, expert revision could either raise or lower measured performance, indicating that translation quality materially affects cross-language evaluation results.

Closest papers

Nearest neighbours by meaning across the whole index.

Labadain-MedQA: A Tetun Medical QA Dataset for Fine-Tuning and Evaluating Large Language Models

cs.CL cs.AI ·2026-10-31 ·Gabriel de Jesus, Sérgio Nunes
code/data similarity 0.74
Abstract

Advances in large language models (LLMs) have created opportunities for cross-lingual transfer of medical knowledge from high-resource to low-resource languages to support access to healthcare information. However, medical question-answering (QA) datasets for fine-tuning and evaluating LLMs remain scarce for Tetun. To address this gap, we translated MedAlpaca's Medical Flashcards and WikiDoc Patient Information collections into Tetun using Gemini 2.5 Flash, producing 39,077 medical QA pairs. Translation quality was assessed on 50 randomly sampled QA pairs (100 documents) using automatic metrics against human reference translations and evaluations by two native Tetun-speaking healthcare professionals, focusing on medical accuracy and Tetun fluency. Human translations achieved higher mean ratings than LLM-generated translations for both criteria (4.43/5 vs. 4.02/5), with statistically significant differences (Wilcoxon signed-rank test, p < 0.001). To assess downstream utility, we fine-tuned Gemma and Llama variants on the translated MedAlpaca dataset using parameter-efficient fine-tuning (PEFT) and evaluated them on 325 Tetun-translated United States Medical Licensing Examination multiple-choice questions. Gemma 4 12B fine-tuned using QLoRA achieved relative improvements in mean accuracy of 10.79% with 4-bit NormalFloat (NF4) inference and 10.42% after merging the LoRA adapters into the BF16 base model, compared with the corresponding base models. These results highlight the viability of automatic dataset translation for Tetun medical QA and the effectiveness of PEFT in enhancing model performance. The datasets, models, and evaluation resources are accessible at https://github.com/labadain/labadain-medqa to support reproducible research on Tetun medical QA and facilitate machine translation, cross lingual, and multilingual research.

0.32

Analyzing and Mitigating Cross-Lingual Degradation in Multilingual Medical VQA

cs.AI ·2026-08-23 ·Jingbo Wang, Sendong Zhao, Haochun Wang, Bing Qin, Ting Liu
top venuebenchmark similarity 0.70
Abstract · EMNLP 2026 main

Medical visual question answering (VQA) is a crucial task in clinical AI, yet its evaluation has so far centered almost exclusively on English, limiting its relevance to linguistically diverse patients and clinicians. Recent multilingual medical VQA benchmarks show that large vision-language models (LVLMs) degrade in non-English languages, but lack a fine-grained analysis of how cross-lingual variation affects the distinct capabilities that medical VQA requires. To this end, we construct a multilingual medical VQA benchmark over eight languages, organized into four representative scenarios that isolate the core capabilities medical VQA requires. Evaluating five open- and closed-source LVLMs, we find that cross-lingual degradation is not uniform but highly scenario-dependent. We therefore propose MedVL-XLRepE, a training-free scenario-aware representation engineering method, leveraging LVLMs' superior English medical VQA capability to steer non-English representations toward their English counterparts at inference time. Across three LVLMs and eight languages, MedVL-XLRepE consistently mitigates cross-lingual degradation, with gains of up to 6.33\%.

0.35

Refined Assessment for Translation Evaluation: Rethinking Machine Translation Evaluation in the Era of Human-Level Systems

cs.CL ·2026-10-24 ·Dmitry Popov, Vladislav Negodin, Ekaterina Enikeeva, Iana Matrosova, Nikolay Karpachev +1 more
top venuedatasetcode/datahighly cited similarity 0.69
Abstract · Published in Findings of EMNLP 2025. 17 pages. Dataset: https://huggingface.co/datasets/yandex/wmt24-en-ru-rate

As machine translation systems approach human-level quality, traditional evaluation methodologies struggle to detect subtle translation errors. We critically examine limitations in current gold-standard approaches (MQM and ESA), including inconsistencies from variable annotator expertise, excessive categorization complexity, coarse severity granularity, accuracy bias over fluency, and time constraints. To address this issue, we introduce a high-quality dataset consisting of human evaluations for English-Russian translations from WMT24, created by professional linguists. We show that expert assessments without time pressure yield substantially different results from standard evaluations. To enable consistent and rich annotation by these experts, we developed the RATE (Refined Assessment for Translation Evaluation) protocol. RATE provides a streamlined error taxonomy, expanded severity ratings, and multidimensional scoring balancing accuracy and fluency, facilitating deeper analysis of MT outputs. Our analysis, powered by this expert dataset, reveals that state-of-the-art MT systems may have surpassed human translations in accuracy while still lagging in fluency - a critical distinction obscured by existing accuracy-biased metrics. Our findings highlight that advancing MT evaluation requires not only better protocols but crucially, high-quality annotations from skilled linguists.

0.64

Understanding Multilingual Medical ASR Adaptation Through Layer-Wise Analysis

cs.CL cs.AIcs.LGcs.SD ·2026-08-19 ·Souranil Kahali, Rituparna Bose, Abner Hernandez, Tomas Arias-Vergara, Andreas Maier +2 more
similarity 0.68
Abstract

Medical automatic speech recognition (MedASR) requires adaptation to specialised terminology, limited annotated clinical data, and multilingual use cases. Although large-scale pretrained ASR models such as Whisper achieve strong generalisation, their behaviour after medical and multilingual adaptation remains insufficiently understood beyond word error rate (WER). This paper investigates how multilingual medical adaptation reshapes the internal representations of Whisper models through layer-wise encoder analysis. We compare zero-shot decoding, English-only fine-tuning, German-only diagnostic fine-tuning, two-stage EN->EN+DE continuation, and direct EN+DE fine-tuning across Whisper model sizes. Fine-tuning substantially improves MedASR performance, but the best model depends on the adaptation setting: Whisper-Medium gives the lowest English WER (7.72%) and the lowest combined EN+DE WER under direct EN+DE training (26.30%); German-only Whisper-Large-v3 gives the lowest German WER (44.96%), but as a within-corpus diagnostic on 86 single-speaker training utterances rather than robust generalisation. Layer-wise analysis of the two-stage Whisper-Small trajectory shows that English medical fine-tuning produces the dominant encoder shift, whereas multilingual continuation largely preserves the adapted representation space. Domain and language information remain highly recoverable across layers, while linearly recoverable error-predictive cues weaken as WER improves.

0.10

DeepSEA: A Multilingual Evaluation Benchmark for Southeast Asia

cs.CL ·2026-10-19 ·Jiuzhou Han, Abhishek Bijay Mishra, Trevor Cohn, Shubham Mittal
benchmarkcode/data similarity 0.67
Abstract · For the codebase and dataset, see https://github.com/google-research/deep-sea

While language models have demonstrated remarkable capabilities, their performance remains disproportionately skewed towards high-resource languages. This disparity is particularly acute for the 700 million inhabitants of Southeast Asia, where vast linguistic diversity remains under-represented in existing benchmarks, often suffering from limited language coverage or narrow task scopes. To address this, we introduce DeepSEA, a comprehensive benchmark constructed from established datasets through professional human translation into 12 Southeast Asian languages, spanning both high-resource (e.g., Indonesian, Thai, Vietnamese) and low-resource (e.g., Burmese, Khmer, Lao) tiers across five distinct tasks: mathematical reasoning, scientific reasoning, question answering, abstractive summarization, and machine translation. Extensive evaluation of frontier proprietary and open-weights models reveals that while frontier models like Gemini-3.7-Flash maintain robustness across resource tiers, smaller models face severe performance degradation on low-resource languages. Crucially, models perform better in reasoning and summarization when pivoted through English rather than target languages, exposing a critical dependency on English representations, especially for low-resource languages. Beyond these observations, we provide a cross-lingual error analysis and a cross-script tokenizer fertility analysis. We hope these findings shed light on the development of next-generation inclusive multilingual models.

0.34

A primer on evaluation methods for large language models in healthcare

cs.CL cs.AI ·2026-09-13 ·Suzannah E McKinney, Phuc Vu, Samuel A Justice, Christopher Humphries, Alyssa Pradhan +8 more
similarity 0.67
Abstract

Large language models (LLMs) have a growing range of applications in medicine, and their evaluation is critical for ensuring they provide benefit and not harm. This evaluation can be more challenging than traditional machine learning for many reasons, including probabilistic and open-ended outputs, and behavior that shifts with prompt design and accumulated context. This review covers four key areas of LLM evaluation: principles of study design, statistical methods, capability evaluation and clinical application evaluation. Capability evaluation considers different benchmarks, including multiple-choice, agentic and multi-turn benchmarks, alongside operational metrics like token usage and latency. Clinical application evaluation addresses establishing accuracy of free text outputs, such as human review and LLM-as-a-judge, and clinical trial approaches. Across sections, we describe underlying concepts and potential pitfalls, while emphasizing the importance of aligning evaluation methods with the research question. Together, this article aims to provide a pragmatic basis for designing and executing rigorous evaluations of healthcare LLMs.

0.15

CardioLM: A multilingual suite of small language models for the cardiology domain

cs.CL cs.AI ·2026-11-05 ·Manuela-Daniela Danu, Miguel Rodríguez-Ortega, Alberto Becerra-Tome, Pablo Arancibia, Fernando Gallego-Donoso +35 more
benchmark similarity 0.67
Abstract · 91 pages, 7 figures, 33 tables (9 in the main text, 23 in Appendix A, and 1 in Appendix B)

Background: Cardiovascular care generates large volumes of clinical free-text documentation in local languages. However, clinical natural language processing (NLP) resources remain concentrated in English, and no existing benchmark is cardiology-specific, multilingual, and broad in entity coverage. Methods: We present two contributions. The first is CardioCCC, a corpus of 508 cardiology case reports originally published in Spanish and extended to Czech, Dutch, English, Italian, Romanian, and Swedish through machine translation, annotation projection, and clinician review, with annotations covering diseases, symptoms, procedures, and medications. The second is CardioLM, comprising CardioBERTa, a set of language-specific encoders obtained by continued pretraining on cardiology and biomedical corpora, and CardioNER, a set of named entity recognition (NER) models fine-tuned on CardioCCC. Results: Cardiology-specific pretraining reduced pseudo-perplexity by up to a factor of eight, yet changed strict span-level F1 by at most 0.04, with benefits concentrated in languages whose backbones lacked biomedical coverage. The jointly trained multilingual XLM-RoBERTa-large models achieved the best strict F1 in nearly every language and entity type, exceeding the strongest monolingual system by up to 0.13 F1. A large share of residual errors concerned boundary detection: relaxed matching recovered 0.10-0.23 F1 for disease, procedure, and symptom, but only 0.01-0.07 for medication. Clinicians rated CardioNER well above a rule- and dictionary-based baseline, with the mean rating across entity types rising from 26% to 73%. Conclusions: Specialty-specific pretraining is not the decisive factor for downstream entity recognition, whereas multilingual joint training yields the strongest results in nearly all settings and a simpler deployment path for multi-country clinical information extraction.

0.24

A corpus-specific clinical RAG system matches or outperforms newer frontier LLMs on HealthBench

cs.CL cs.AIcs.HCcs.IR+1 ·2026-08-12 ·Praveen Reddy, Charuta Mandke, Suvrankar Datta, Sarah Khan, Siddharth Reddy Anthireddy +2 more
benchmark similarity 0.67
Abstract · 2 tables

General-purpose large language models (LLMs) have recently been reported to match or exceed specialized clinical AI tools on medical benchmarks, but such comparisons draw on a narrow set of systems and on benchmarks developed largely in high-income settings. We evaluate VITA, a retrieval-augmented generation (RAG) system purpose-built for contextual knowledge retrieval in India and other low- and middle-income (LMIC) settings. VITA retrieves from a curated corpus of disease-specific guidelines, India-specific antimicrobial resistance data, national formulary constraints, and resource-limited care protocols; its architecture and corpus are proprietary, but the benchmark, the physician-written rubrics, and our full response and scoring outputs are public for independent verification. On 4,023 English-language HealthBench questions (80.5% of the benchmark), scored with a GPT-4.1 judge, VITA ranked first with 51.9% of possible rubric points, ahead of GPT-5.4 (46.1%), o4-mini (44.3%), Gemini 3.1 Pro (42.6%), and Claude Sonnet 4.6 (37.3%), and scored highest on 45.4% of questions. To test robustness to newer models and judge lineage, a 500-question subset was re-run against current-generation models (GPT-5.5, Claude Opus 4.8, Gemini 3.5 Pro, Grok 4.3) and graded by a neutral open-weight judge (DeepSeek-V4-Pro) sharing no lineage with any system tested. Here the gap narrowed to parity: VITA and GPT-5.5 were statistically indistinguishable on mean per-question score, while VITA led on points-weighted score and won the most questions. VITA's advantages in accuracy and completeness persisted under the neutral judge; its communication scores were lower. These results indicate that a purpose-built clinical RAG system remains competitive with frontier LLMs on an open benchmark, consistent with corpus specificity as a design variable that improves grounding at some cost to communication polish.

0.04