CS Paper Radar

Labadain-MedQA: A Tetun Medical QA Dataset for Fine-Tuning and Evaluating Large Language Models

Gabriel de Jesus, Sérgio Nunes

cs.CL cs.AI ·submitted 2026-10-31 13:36 UTC · v2
code/data

Abstract

Advances in large language models (LLMs) have created opportunities for cross-lingual transfer of medical knowledge from high-resource to low-resource languages to support access to healthcare information. However, medical question-answering (QA) datasets for fine-tuning and evaluating LLMs remain scarce for Tetun. To address this gap, we translated MedAlpaca's Medical Flashcards and WikiDoc Patient Information collections into Tetun using Gemini 2.5 Flash, producing 39,077 medical QA pairs. Translation quality was assessed on 50 randomly sampled QA pairs (100 documents) using automatic metrics against human reference translations and evaluations by two native Tetun-speaking healthcare professionals, focusing on medical accuracy and Tetun fluency. Human translations achieved higher mean ratings than LLM-generated translations for both criteria (4.43/5 vs. 4.02/5), with statistically significant differences (Wilcoxon signed-rank test, p < 0.001). To assess downstream utility, we fine-tuned Gemma and Llama variants on the translated MedAlpaca dataset using parameter-efficient fine-tuning (PEFT) and evaluated them on 325 Tetun-translated United States Medical Licensing Examination multiple-choice questions. Gemma 4 12B fine-tuned using QLoRA achieved relative improvements in mean accuracy of 10.79% with 4-bit NormalFloat (NF4) inference and 10.42% after merging the LoRA adapters into the BF16 base model, compared with the corresponding base models. These results highlight the viability of automatic dataset translation for Tetun medical QA and the effectiveness of PEFT in enhancing model performance. The datasets, models, and evaluation resources are accessible at https://github.com/labadain/labadain-medqa to support reproducible research on Tetun medical QA and facilitate machine translation, cross lingual, and multilingual research.

Closest papers

Nearest neighbours by meaning across the whole index.

HealMed: Multilingual Evaluation of Large Language Models in Medicine

cs.CL ·2026-08-20 ·Yingjian Chen, Fan Gao, Sherry T. Tong, Haoyu Zhang, Aosong Feng +40 more
benchmarkcode/data similarity 0.74
Abstract

We present HealMed, an expert-reviewed benchmark for multilingual evaluation of large language models in medicine. HealMed contains 1,000 examples in each of nine languages, drawn from nine datasets and covering three task formats: MCQA, NLI and open-ended QA. The benchmark was developed over two years by 23 physicians and medical experts based across nine countries and regions. Each translation was evaluated and revised by two experts fluent in English and the corresponding target language. On HealMed, performance declined most in low-resource languages, although the size of the gap varied markedly across languages and models. The strongest proprietary models were the most stable across languages, whereas many open-source and medically specialized models showed larger and less consistent gaps. Medical specialization alone did not ensure multilingual robustness. Furthermore, expert revision could either raise or lower measured performance, indicating that translation quality materially affects cross-language evaluation results.

0.28

Refined Assessment for Translation Evaluation: Rethinking Machine Translation Evaluation in the Era of Human-Level Systems

cs.CL ·2026-10-24 ·Dmitry Popov, Vladislav Negodin, Ekaterina Enikeeva, Iana Matrosova, Nikolay Karpachev +1 more
top venuedatasetcode/datahighly cited similarity 0.71
Abstract · Published in Findings of EMNLP 2025. 17 pages. Dataset: https://huggingface.co/datasets/yandex/wmt24-en-ru-rate

As machine translation systems approach human-level quality, traditional evaluation methodologies struggle to detect subtle translation errors. We critically examine limitations in current gold-standard approaches (MQM and ESA), including inconsistencies from variable annotator expertise, excessive categorization complexity, coarse severity granularity, accuracy bias over fluency, and time constraints. To address this issue, we introduce a high-quality dataset consisting of human evaluations for English-Russian translations from WMT24, created by professional linguists. We show that expert assessments without time pressure yield substantially different results from standard evaluations. To enable consistent and rich annotation by these experts, we developed the RATE (Refined Assessment for Translation Evaluation) protocol. RATE provides a streamlined error taxonomy, expanded severity ratings, and multidimensional scoring balancing accuracy and fluency, facilitating deeper analysis of MT outputs. Our analysis, powered by this expert dataset, reveals that state-of-the-art MT systems may have surpassed human translations in accuracy while still lagging in fluency - a critical distinction obscured by existing accuracy-biased metrics. Our findings highlight that advancing MT evaluation requires not only better protocols but crucially, high-quality annotations from skilled linguists.

0.64

LusoClin: A Synthetic Clinical Note Dataset for Medical Information Retrieval in European Portuguese

cs.AI cs.IR ·2026-11-17 ·Carla Teixeira Lopes, Daniel Félix
datasetcode/data similarity 0.68
Abstract

Access to large-scale clinical text collections is crucial for advancing medical information retrieval research, including clinical note search, patient cohort identification, and domain-adapted retrieval models. However, real clinical notes are rarely available due to privacy regulations, which particularly limits progress for low-resource languages such as European Portuguese. We present LusoClin, a publicly released dataset of synthetic clinical notes in European Portuguese, created to support privacy-preserving research on clinical text retrieval. LusoClin was generated by pre-processing real clinical data, fine-tuning the open-source Llama 3.2 (3B) instruction-tuned model using Quantized Low-Rank Adaptation, and applying prompt-based clinical note generation. To facilitate semantic indexing and clinical search, the notes are automatically annotated with clinical entities using a BERT-based model. We evaluate LusoClin in terms of utility, fidelity, diversity, and privacy using automatic metrics and human evaluation. Results indicate that the dataset captures clinically relevant language patterns and can support downstream IR applications such as clinical document retrieval and domain-specific model adaptation, although annotators can often distinguish synthetic from real notes and some medical inconsistencies persist.

0.28

Large Language Models for Machine Translation Quality Annotation: Humans and Models Are Both Challenged

cs.CL ·2026-10-07 ·Hala Almaghout, Christian Federmann, Qin Gao
top venue similarity 0.67
Abstract · Accepted at EMNLP 2026

Large Language Models (LLMs) are considered to be a more efficient and cost-effective alternative to human judgment for Machine Translation (MT) evaluation. With MT evaluation spanning a large number of language pairs, domains and levels of annotation granularity, LLMs must be thoroughly evaluated across these dimensions before being reliably used as alternatives to human evaluation. In this paper, we evaluate the performance of LLMs for two prominent MT quality evaluation schemes: Multidimensional Quality Metrics (MQM) and Error Span Annotation (ESA) by comparing their agreement with human annotators. We present results on a long-context test set of 70 language pairs and the publicly available WMT23 and WMT25 data, investigating both score and error span annotation agreement across a variety of language pairs and domains. Our results show that while LLM agreement with human annotators exceeds agreement between human annotators for some evaluation tasks, both vary substantially across annotation schemes, language pairs and domains and remain unreliable for most settings. Furthermore, we identify challenges facing both human and LLM annotators: humans are particularly challenged by fine-grained MQM annotations and low-resource language pairs, while LLMs struggle with minor errors, wrong language variants and error span annotation. Our results highlight the potential for improvement for both human and LLM annotation performance, possibly through human-LLM collaborative annotation pipelines that address the reliability issues identified in this work.

0.22

TeochewBench: A Human-Reviewed Benchmark for Teochew Hanzi Translation

cs.CL ·2026-09-16 ·Jianan Wu
benchmark similarity 0.66
Abstract · 11 pages

Teochew has a substantial speaker community and exhibits distinctive lexical, syntactic, and pragmatic features, yet textual resources for evaluating large language models remain limited. We present TeochewBench, a human-reviewed benchmark comprising 300 Teochew Hanzi expressions for evaluating translation from Teochew Hanzi into Mandarin Chinese and English. The dataset covers five categories: basic vocabulary; everyday sentences; Teochew-specific expressions; tone, politeness, and context; and idiomatic, ambiguous, and culturally specific expressions. A primary Teochew-speaking reviewer examined all entries individually and revised them as needed, while two additional Teochew speakers verified selected items. Our main evaluation covers 11 official general-purpose post-trained models on the reviewed dataset in both translation directions, yielding 6,600 predictions. Two official base checkpoints provide 1,200 predictions for supplementary diagnostics, bringing the total to 13 models and 7,800 predictions. We additionally include a Hanzi-copy control, which returns the source input unchanged, to assess how shared Hanzi affect automatic scores for translation into Mandarin Chinese. Qwen3.5-27B achieved the highest overall chrF-style score among the evaluated checkpoints, at 60.63, followed by Qwen2.5-72B-Instruct at 56.61, Gemma-3-27B-IT at 56.36, and GLM-4-32B-0414 at 55.82. Across the 11 main-evaluation models, the mean chrF-style score decreased from 69.25 for low-specificity items to 27.52 for high-specificity items. High-specificity expressions received lower scores and exhibited smaller cross-model differences, suggesting that they constitute a shared low-scoring region across the model families evaluated here. The Hanzi-copy control further indicates that surface overlap in low-specificity items can substantially affect automatic scores for translation into Mandarin Chinese.

0.23

Clinician use of language models diverges from how the models are evaluated

cs.CL ·2026-10-08 ·Krithik Vishwanath, Haitong Lin, Anton Alyakin, Jin Vivian Lee, D. Brock Hewitt +17 more
benchmark similarity 0.65
Abstract

Large language model (LLM) assistants are being deployed to clinicians across health systems, and judgments about their readiness rest largely on benchmark scores, most of them derived from examination questions or curated cases. A benchmark predicts performance in deployment only to the extent that its items resemble real use, yet whether benchmarks reflect the work these systems receive has rarely been measured. Here we analyze 127,833 queries sent by 6,342 physicians, advanced practice providers and nurses in 35 specialties to an institutional assistant during an eight-month roll-out. We characterize each query with RCQ-Map, a clinician-validated framework grounded in taxonomies of clinical questions and of LLM evaluation, which records its task, intent, answerability, missing information and potential harm. Documentation and administration (36.2%) and knowledge retrieval (28.9%) made up nearly two-thirds of use, and diagnosis 3.7%; more than a third of queries could not be answered well as posed. Applying RCQ-Map to 58 public benchmarks drawn from major evaluation suites and frontier model reports, which we assemble into the Clinical AI Benchmark Atlas, showed that the median benchmark contained no documentation requests and shared 31% of the task mix of real use, less than an even spread across task categories would. Benchmarks in suites designed to resemble clinical practice were individually no closer to real use than those used in frontier model reports. Benchmark scores therefore say little about how clinical AI performs on most of the work it is actually given, and evaluation should be matched to real clinical use.

0.08

The University of Melbourne WMT 2026 CreoleMT Submission: A Domain-Balanced Approach to Low-Resource Pacific Creole Machine Translation

cs.CL ·2026-09-12 ·Raphaël Merx, Nick Thieberger, Ekaterina Vylomova
published similarity 0.65
Abstract

For our submission to the WMT26 Creole Language Translation Shared Task, we focus on machine translation (MT) models for Pacific creoles: Tok Pisin, Bislama, and Solomon Pijin, with particular attention to broad domain performance. After pre-training on a large collection of domain-imbalanced data, we continue fine-tuning on a diverse mix of domain-balanced data. We rely on a number of data collection and preparation techniques, including LLM-assisted respelling and alignment, back-translation, and distillation from Gemini for domains originally not present in training data. Evaluated on Bouquet and a novel test set made of spoken language transcripts, our models beat open model baselines by 3+ chrF++ points in all directions with human-original references. Looking ahead, we plan to develop human-translated test sets for Solomon Pijin and Bislama, and to distil our best models into much smaller ones that retain broad domain coverage.

0.33

A corpus-specific clinical RAG system matches or outperforms newer frontier LLMs on HealthBench

cs.CL cs.AIcs.HCcs.IR+1 ·2026-08-12 ·Praveen Reddy, Charuta Mandke, Suvrankar Datta, Sarah Khan, Siddharth Reddy Anthireddy +2 more
benchmark similarity 0.65
Abstract · 2 tables

General-purpose large language models (LLMs) have recently been reported to match or exceed specialized clinical AI tools on medical benchmarks, but such comparisons draw on a narrow set of systems and on benchmarks developed largely in high-income settings. We evaluate VITA, a retrieval-augmented generation (RAG) system purpose-built for contextual knowledge retrieval in India and other low- and middle-income (LMIC) settings. VITA retrieves from a curated corpus of disease-specific guidelines, India-specific antimicrobial resistance data, national formulary constraints, and resource-limited care protocols; its architecture and corpus are proprietary, but the benchmark, the physician-written rubrics, and our full response and scoring outputs are public for independent verification. On 4,023 English-language HealthBench questions (80.5% of the benchmark), scored with a GPT-4.1 judge, VITA ranked first with 51.9% of possible rubric points, ahead of GPT-5.4 (46.1%), o4-mini (44.3%), Gemini 3.1 Pro (42.6%), and Claude Sonnet 4.6 (37.3%), and scored highest on 45.4% of questions. To test robustness to newer models and judge lineage, a 500-question subset was re-run against current-generation models (GPT-5.5, Claude Opus 4.8, Gemini 3.5 Pro, Grok 4.3) and graded by a neutral open-weight judge (DeepSeek-V4-Pro) sharing no lineage with any system tested. Here the gap narrowed to parity: VITA and GPT-5.5 were statistically indistinguishable on mean per-question score, while VITA led on points-weighted score and won the most questions. VITA's advantages in accuracy and completeness persisted under the neutral judge; its communication scores were lower. These results indicate that a purpose-built clinical RAG system remains competitive with frontier LLMs on an open benchmark, consistent with corpus specificity as a design variable that improves grounding at some cost to communication polish.

0.04