CS Paper Radar

LusoClin: A Synthetic Clinical Note Dataset for Medical Information Retrieval in European Portuguese

Carla Teixeira Lopes, Daniel Félix

cs.AI cs.IR ·submitted 2026-11-17 20:03 UTC · v1
datasetcode/data

Abstract

Access to large-scale clinical text collections is crucial for advancing medical information retrieval research, including clinical note search, patient cohort identification, and domain-adapted retrieval models. However, real clinical notes are rarely available due to privacy regulations, which particularly limits progress for low-resource languages such as European Portuguese. We present LusoClin, a publicly released dataset of synthetic clinical notes in European Portuguese, created to support privacy-preserving research on clinical text retrieval. LusoClin was generated by pre-processing real clinical data, fine-tuning the open-source Llama 3.2 (3B) instruction-tuned model using Quantized Low-Rank Adaptation, and applying prompt-based clinical note generation. To facilitate semantic indexing and clinical search, the notes are automatically annotated with clinical entities using a BERT-based model. We evaluate LusoClin in terms of utility, fidelity, diversity, and privacy using automatic metrics and human evaluation. Results indicate that the dataset captures clinically relevant language patterns and can support downstream IR applications such as clinical document retrieval and domain-specific model adaptation, although annotators can often distinguish synthetic from real notes and some medical inconsistencies persist.

Closest papers

Nearest neighbours by meaning across the whole index.

Future Querying: Can LLMs Serve as Implicit Medical World Models?

cs.CL cs.AI ·2026-08-24 ·Siri Willems, James Butterworth, Lore Goetschalckx, Peter Vrancx, Philippe Modard +2 more
published similarity 0.71
Abstract · This paper is accepted at The 1st MICCAI Workshop on Medical World Models (MICCAI-2026)

Traditional clinical prediction models rely on task-specific pipelines and curated, structured data, which scale poorly and underutilize unstructured text. To address this, we introduce future querying, a paradigm that probes whether large language models (LLMs) can function as implicit medical world models by evaluating their ability to answer time-indexed clinical queries about a patient's future. Our framework operates on unstructured clinical documentation using endpoint-agnostic training, enabling a single model to answer diverse clinical queries over patient trajectories without manual feature engineering or task-specific retraining. We show that small, locally fine-tuned open-weight models can match or approach larger proprietary systems, making the framework suitable for privacy-preserving, on-premise deployment. Evaluated on a new synthetic medical reports dataset and real ICU notes from the MIMIC-IV dataset, our results provide encouraging evidence that LLMs can capture aspects of clinical dynamics.

0.30

A Living Benchmark for Information Retrieval from Electronic Health Records

cs.AI ·2026-09-24 ·Jordan L. Cahoon, Chloe O. Stanwyck, Sulaiman Somani, Philip Chung, Kevin R Keet +21 more
benchmark similarity 0.70
Abstract

Large language model (LLM)-based clinical assistants are increasingly being integrated into electronic health record (EHR) systems, transforming how clinicians retrieve and synthesize information from patient records. Their safety and utility depend on rigorous evaluation, yet existing benchmarks are manually curated, costly to update, and rapidly become obsolete with evolving technological advancements. We present a scalable framework that automatically generates question--answer pairs from longitudinal EHR notes. Nineteen clinicians validate the benchmark generator, producing the Benchmark for Retrieving Information in EHRs (BRIE), a continuously maintainable evaluation dataset. Across nine LLMs and five inference strategies, state-of-the-art systems frequently omit clinically important information, particularly for questions requiring synthesis across multiple documents and encounters. Because the generator itself is validated, BRIE supports evaluations that static benchmarks cannot, including the generation of multiple answers that reflect variation in clinician reasoning for robust performance assessment and continuously refreshing benchmark content to guard against leakage. Our results demonstrate that scalable benchmark generation enables rigorous, up-to-date evaluation of clinical LLMs as they are deployed in rapidly evolving healthcare settings.

0.30

Generating Diverse and Verified Synthetic Clinical Notes with Labels by Construction

cs.LG cs.AIcs.CL ·2026-11-07 ·Matthias Lehmann, Madeleine Werthebach
publishedbenchmarkcode/data similarity 0.69
Abstract · Accepted at the GenAI for Health Workshop @ NeurIPS 2026. 38 pages including appendix. Code: https://github.com/Matt00n/phi_discharge_letter…

Under strict privacy regulations in the clinical domain, de-identification is necessary to enable the use of clinical data such as for natural language processing. However, we currently lack sophisticated ways to tell which de-identification models actually are suitable. Specifically, we need benchmarks that are challenging, diverse, and clinically plausible, all while ensuring label correctness. To this end, we present SPARCLING, an LLM-based pipeline to generate synthetic discharge letters with character-exact PHI span annotations. Our pipeline combines structured attribute sampling, template generation, and red teaming to obtain diverse PHI-labeled discharge letters. In our experiments, we demonstrate this superior content diversity over existing public datasets. Further, we show SPARCLING's downstream utility as a benchmark to uncover failure modes of de-identifiers in the German clinical domain. Finally, our experiments show that training on our synthetic data can yield more capable de-identifiers than training on the scarce public data alone. Our code is available at https://github.com/Matt00n/phi_discharge_letter_generator.

0.38

MedDeID enables locally governed clinical-text de-identification from real or synthetic training data

cs.CL cs.LG ·2026-09-09 ·Stig Hellemans, Tom Stroobants, Elyne Scheurwegs, Pieter Meysman, Philippe G. Jorens +1 more
benchmark similarity 0.68
Abstract · 64 pages total: 32-page main manuscript with 4 figures, followed by 32-page Supplementary Information

Clinical notes contain personally identifiable information (PII), restricting reuse for research and medical AI, especially when data cannot leave an institution. We developed MedDeID, an on-premises framework combining in-house annotation and synthetic-note generation with model training, inference, pseudonymisation and evaluation. On an independently annotated, adjudicated 300-note Dutch hospital benchmark, a hospital-trained compact transformer detected 98.9% of identifying text while redacting 0.24% of text outside annotated identifiers; a synthetic-only counterpart detected 96.1%. On 100 primary-care notes, the synthetic-trained model achieved higher recall than the hospital-trained model (90.3% versus 87.0%) and greater robustness to identifier-format perturbations. An English instantiation trained without real text detected 99.7% and 98.9% of annotated identifier characters on two external synthetic benchmarks. These results demonstrate transfer of the workflow to another language, but not clinical English performance. MedDeID provides a route to locally governed de-identification using real or synthetic training data.

0.52

Meddies-PII: A Multilingual Framework for Personally Identifiable Information Extraction in Clinical De-identification

cs.CL cs.AI ·2026-09-11 ·Linh Uyen Le, Ho Dinh Tri, Christian Hoang, Huy Hoang Ha
benchmarkdataset similarity 0.68
Abstract

Clinical de-identification relies on accurately identifying personally identifiable information (PII). However, manually annotated datasets are costly to construct, while existing synthetic alternatives often provide limited details about their generation process or rely on relatively simple synthesis strategies. We introduce Meddies-PII-Dataset, a corpus of one million synthetic clinical documents spanning seventeen languages and nine PII labels. The documents are generated using attribute-conditioned prompts and validated through thirteen deterministic gates that enforce structural and annotation consistency. To evaluate the dataset's utility, we train Meddies-PII-Model, a BIOES token classifier, and compare it with existing PII extraction systems using exact-match entity-level F1. Meddies-PII-Model achieves the highest performance among the evaluated systems on all reported benchmarks, with a mean F1 of 0.827 across fifteen external benchmarks, compared with 0.658 for the strongest baseline. Upon acceptance, we will publicly release the dataset, benchmark suite, model, generation framework, and evaluation code to support research on multilingual clinical de-identification.

0.14

DocTalk: Enhancing Medical Knowledge Retrieval via Fine-tuned Large Language Models with Chain-of-Thought Reasoning for Robust Clinical Decision Support

cs.AI cs.CLcs.CV ·2026-10-26 ·Asad Gohar, Md Ariful Islam Mozumder, Moon-Il Joo, Hee-Cheol Kim
code/data similarity 0.68
Abstract

Objective: The rapid advancement of large language models (LLMs) in healthcare has opened new possibilities for AI-assisted clinical decision-making; however, safe and effective deployment remains challenging because of hallucination and domain misalignment. This study introduces DocTalk, a doctor-assistive question-answering (QA) system designed to generate concise, chart-grounded responses from de-identified discharge summaries. Methods: We developed a high-fidelity data generation pipeline that produces 500 clinically relevant QA pairs through sentence-level decomposition, chain-of-thought-guided question formulation, and expert review. Six open-source LLMs, including three general-purpose and three biomedical models, were evaluated before and after parameter-efficient instruction tuning using Low-Rank Adaptation (LoRA). The framework integrates prompt engineering, in-context learning, and medically aligned evaluation to support factual and interpretable responses. Results: On DocTalk-QA, instruction tuning produced consistent improvements across lexical, semantic, and clinical fidelity metrics. The best-performing tuned model, Llama-3-Med42-8B, achieved ROUGE-L = 0.40, BERTScore-F1 = 0.76, and UMLS-F1 = 0.49. To examine external generalization beyond the DocTalk-QA dataset, the two best-performing models, Llama-3.1-8B-Instruct and Llama-3-Med42-8B, were evaluated on PubMedQA before and after instruction tuning. Accuracy improved from 0.931 to 0.977 for Llama-3.1-8B-Instruct and from 0.935 to 0.943 for Llama-3-Med42-8B. Conclusion: DocTalk was deployed as a secure web-based platform for interactive EHR querying. These findings suggest that clinically grounded instruction tuning can improve medical QA performance and support practical clinical decision support.

0.26

Labadain-MedQA: A Tetun Medical QA Dataset for Fine-Tuning and Evaluating Large Language Models

cs.CL cs.AI ·2026-10-31 ·Gabriel de Jesus, Sérgio Nunes
code/data similarity 0.68
Abstract

Advances in large language models (LLMs) have created opportunities for cross-lingual transfer of medical knowledge from high-resource to low-resource languages to support access to healthcare information. However, medical question-answering (QA) datasets for fine-tuning and evaluating LLMs remain scarce for Tetun. To address this gap, we translated MedAlpaca's Medical Flashcards and WikiDoc Patient Information collections into Tetun using Gemini 2.5 Flash, producing 39,077 medical QA pairs. Translation quality was assessed on 50 randomly sampled QA pairs (100 documents) using automatic metrics against human reference translations and evaluations by two native Tetun-speaking healthcare professionals, focusing on medical accuracy and Tetun fluency. Human translations achieved higher mean ratings than LLM-generated translations for both criteria (4.43/5 vs. 4.02/5), with statistically significant differences (Wilcoxon signed-rank test, p < 0.001). To assess downstream utility, we fine-tuned Gemma and Llama variants on the translated MedAlpaca dataset using parameter-efficient fine-tuning (PEFT) and evaluated them on 325 Tetun-translated United States Medical Licensing Examination multiple-choice questions. Gemma 4 12B fine-tuned using QLoRA achieved relative improvements in mean accuracy of 10.79% with 4-bit NormalFloat (NF4) inference and 10.42% after merging the LoRA adapters into the BF16 base model, compared with the corresponding base models. These results highlight the viability of automatic dataset translation for Tetun medical QA and the effectiveness of PEFT in enhancing model performance. The datasets, models, and evaluation resources are accessible at https://github.com/labadain/labadain-medqa to support reproducible research on Tetun medical QA and facilitate machine translation, cross lingual, and multilingual research.

0.32

MedAstra: ASR-less Speech Retrieval with Diagnostic Grounding for Medical QA

cs.CL ·2026-10-31 ·Elahe Khatibi, Ziyu Wang, Amir M. Rahmani
similarity 0.66
Abstract

Spoken medical question answering can fail when automatic speech recognition (ASR) corrupts a clinically important term before retrieval. We present MedAstra, a framework that maps frozen WavLM speech representations through a lightweight adapter into a frozen E5 text embedding space. This enables a dense retrieval path that accepts a waveform without a query transcript. Retrieved passages and speech-linked textual metadata support answer generation with entity alternatives, diagnostic contrasts, relation heuristics, and bounded retrieval refinement. ASR-less refers to the initial speech retrieval interface; lexical retrieval, string-based entity correction, and the text generator require textual inputs. The deterministic speech embedding does not constitute a calibrated model of acoustic uncertainty. Reported retrieval results reach 87.6 Recall@10 for the speech-only retriever and 90.4 for the hybrid configuration, compared with 81.0 for transcript-first dense retrieval. Medical QA and ablations provide descriptive system comparisons, with input-provenance and evaluation limitations stated explicitly. We distinguish controlled synthetic acoustic tests from real clinical speech, qualify component attribution, and specify the remaining comparisons needed to assess speech-only QA and clinical generalization.

0.16