CS Paper Radar

Towards Investigating Residual Hearing Loss: Quantification of Fibrosis in a Novel Cochlear OCT Dataset

Julia Dietlmeier, Benjamin Greenberg, Wenxuan He, Teresa Wilson, Rubing Xing, Jordan Hill, Adrienne Fettig, Madeline Otto, Teyhana Rounsavill, Lina A. J. Reiss, Jingang Yi, Noel E. O'Connor, George W. S. Burwood

cs.CV cs.AI ·submitted 2026-08-21 14:59 UTC · v1
top venuecode/dataunusual

Abstract

Objective: Cochlear implants (CIs) are bionic prostheses that restores hearing via electrical stimulation of the auditory nerve. Hybrid CIs, which use electroacoustic stimulation (EAS), combine residual low-frequency acoustic hearing with CI electrical stimulation. Intracochlear fibrosis, which forms in response to the presence of the implant, may impede residual hearing function and gradually reduce the efficacy of EAS. It is therefore a translational objective to study the formation of cochlear fibrosis in rodents, with the goal of reducing fibrotic burden and improving outcomes for CI patients. Methods: We generate and annotate a novel dataset of optical coherence tomography (OCT) images from chronically implanted guinea pigs as part of an ongoing study focused on implant induced fibrosis. Objectively assessing fibrotic burden in this model, with high resolution and repeatability, presents an obvious use case for computer vision methods. Results: We present the results of several state-of-the-art semantic segmentation models and compare their efficacy for identifying cochlear fibrosis and other relevant annotations, using a new library of manually segmented OCT images. Conclusions: We find that the best performance is achieved by using a modified version of the well-known UNET architecture (which we term 2D-OCT-UNET) that operates on the upscaled OCT input resolution. Significance: For the first time, we have successfully applied computer vision techniques to an OCT dataset of implanted cochleae with fibrosis. Using this deep learning model, the cochlear fibrotic burden calculation can be reliably carried out as we verify in our experimental section. The dataset and the project code are available at: https://github.com/juliadietlmeier/CF-OCT-segmentation

Comment
Copyright 2026 IEEE. Personal use of this material is permitted. Citation/DOI: 10.1109/TBME.2025.3537868
Journal ref
IEEE Transactions on Biomedical Engineering, 72(7), pp. 2218-2228, July 2025
DOI
10.1109/TBME.2025.3537868

Closest papers

Nearest neighbours by meaning across the whole index.

Automated Optimization of Patient-Specific Electro-Anatomical Models Fitted to Cochlear Implant SCINSEV

eess.SP ·2026-10-29 ·Minh Q. Vu, Erin L. Bratu, Jack H. Noble
similarity 0.59
Abstract

Purpose: Patient-specific electro-anatomical models (EAMs) of the implanted cochlea are crucial for auditory nerve fiber simulation in cochlear implant (CI) programming and neural health estimation. Fitting an EAM to the stimulation current induced non-stimulating electrode voltage (SCINSEV) currently requires manual expert adjustment or exhaustive search over precomputed forward solutions, neither of which scales to routine clinical use. We present an automated optimization pipeline that fits patient specific EAMs in minutes. Methods: Four compartment tissue label maps (perilymph, soft tissue, modiolus, and bone) derived from postoperative CT were used to construct a finite difference forward model, fitted to the measured SCINSEV by Gaussian process Bayesian optimization. Three reductions cut fitting cost: a coarsened grid with trilinear injection and readout at sub-voxel contact positions; solving half the stimulating contacts and completing three quarters of the matrix by reciprocity; and a Jacobian-based identifiability analysis reducing four resistivities to two. Each reduction was validated separately against the measurement's reciprocity residual and the reproducibility of the fit. Results: Across 43 implanted ears, fitting took a median of 2.6 minutes per ear. Median SCINSEV RMSE on the reduced-resolution objective was 0.069 mV, against 0.084 mV for grid search at a matched evaluation budget. Against an exhaustive full-resolution grid search requiring a median of 9.1 hours per ear, the pipeline reached statistically indistinguishable fitting error roughly 210x faster. Conclusion: Patient-specific cochlear EAM fitting can be performed at clinically practical timescales without expert supervision, removing a major computational barrier to patient-specific cochlear implant programming and cochlear simulation.

0.35

Improving Spectral Resolution via Simultaneous Extracochlear and Apical Ground Contacts: A Neural Simulation Study

eess.SP ·2026-10-30 ·Jared A. Rybarczyk, Erin L. Bratu, Robert F. Labadie, Jack H. Noble
similarity 0.57
Abstract

Objectives: While cochlear implants (CI) can provide excellent speech perception outcomes, speech recognition in noise remains a consistent problem for many patients due to channel interaction. Recent work shows the clinical feasibility of an apical return contact placed in the cochlear helicotrema, which presents new possibilities in terms of experimental stimulation schemes. This study explores the interactions between apical and extracochlear ground contacts, aiming to characterize the effects of dual ground usage on auditory nerve fiber (ANF) dynamics and determine their utility in improving spectral resolution. Design: 6 patients with CIs were used in this retrospective study. Volume conduction models encompassing patient specific electro-anatomical characteristics and ANF compartment models defining neural dynamics were used to generate activation thresholds for 75 evenly spaced fiber bundles throughout each modeled cochlea and for 4 different grounding configurations, including the use of combined grounds. We compare our intra-patient models in terms of threshold shifts and standard deviation of fiber proportions to determine the effects of ground configuration used on channel interaction. Results: For all 6 patients, we observe shifts in ANF activation thresholds for the combined ground models indicative of more specific fiber stimulation per contact. Additionally, our combined ground models exhibit reduced fiber proportion standard deviation for several contacts of the stimulating array when compared to the standard extracochlear ground configuration or apical ground configuration. Conclusions: The shifts in activation thresholds and reduction in standard deviations suggest that stimulation schemes utilizing extracochlear and apical grounds in conjunction can provide reduced channel interaction and enhanced spectral resolution for certain contacts in an array.

0.32

Single-visit screening for intracochlear tissue growth validated against multi-visit electrical measurement changes

eess.SP ·2026-11-02 ·Minh Q. Vu, Erin L. Bratu, Jared A. Rybarczyk, Jack H. Noble
similarity 0.53
Abstract

Purpose: Tissue growth (TG) around cochlear implant electrodes raises impedance but is not reliably visible on CT scans. Routinely recorded stimulus current-induced non-stimulating electrode voltages (SCINSEVs) carry this information, but a single recording has no patient-specific reference. We present an algorithm for detecting signs of significant TG from a single SCINSEV measurement. Methods: TG is assumed to concentrate basally near the electrode insertion site, leaving the apical region mostly unaffected. A patient-specific forward model built from CT is fitted to the apical measurements and predicts the basal ones. The misfit score, T, measures each basal contact's signed relative misfit against the apical misfit, accounting for apical fit quality and measurement noise. An ear is flagged when two adjacent basal contacts cross a predetermined threshold. We compare T with T-delta, a model-free reference, tracking basal relative to apical SCINSEV change since the intra-operative recording, persisting over the last two visits. Results: T had a false-positive rate of 3% on growth-free ears. It agreed with T-delta in 81% of 68 ears (sensitivity 71%; specificity 86%; p = 6e-6). Over 200 patient-level two-fold splits, median held-out agreement was 78% at a false-positive rate of 5.1%. Conclusion: An apically fitted patient-specific model predicts basal SCINSEVs well enough to flag signs of significant TG at a single visit, without an intra-operative baseline. Detections largely agree with persistent multi-visit basal-versus-apical change, a surrogate ground truth for significant TG.

0.44

Estimates of neural health using cochlear implant digital twins correlate with speech recognition

eess.SP ·2026-09-29 ·Erin L. Bratu, Andrea J. DeFreese, Katelyn A. Berg, Margaret Wilson, Aaron C. Moberly +2 more
similarity 0.49
Abstract

The cochlear implant is a neural prosthetic that uses an array of electrodes to directly stimulate auditory nerve fibers with electrical impulses. One factor that is known to impact outcomes is the quality of the electro-neural interface. In this work, we propose a pipeline that permits creating accurate and patient-specific digital twins that model the cochlear implant electro-neural interface. We leverage medical images and electrophysiological measurements from the patient's device for digital twin construction. We validate our digital twins by comparing predictions of neural response measurements to clinical measurements and speech recognition outcomes. Neural health estimated by the digital twin correlates strongly with word recognition rates (R=0.75, p<1e-5) in an analysis of 29 cases and sentence in noise recognition rates (R=0.78, p<1e-4) in an analysis of 21 cases. We also report preliminary findings with digital twin-based patient remapping with 6 subjects, where word recognition rates improved on average by 10 percentage points. These digital twins have the potential to provide clinicians with an unprecedented window into the electro-neural interface for individual cochlear implant recipients, which could lead to improved hearing outcomes when used as a foundation for program customization.

0.24

Model-Guided Design of Low-Context Speech Probes for Cochlear Synaptopathy

eess.AS ·2026-09-28 ·Ahsan J. Cheema, David Meng, Jorge Mejia, Sanna Hou, Sunil Puria
similarity 0.47
Abstract

Cochlear neural degeneration (CND) can impair suprathreshold coding without elevating pure-tone thresholds, complicating its diagnosis when it coexists with hair cell loss. We present a unified comparison of temporal and noise-based probes for CND detection using low-context vowel-consonant-vowel (VCV) syllables to reduce linguistic and contextual cues. Using a phenomenological auditory nerve model, we simulated responses to 21 VCV tokens under time compression, reverberation, and speech-in-noise conditions across presentation levels and seven CND profiles. We computed mutual information (MI) between inner hair cell potentials and auditory nerve neurograms and quantified information loss relative to a normal-hearing baseline. Time compression and amplitude-modulated (AM) noise produced the largest modeled information losses. We then evaluated these stimuli in a consonant-identification study involving 36 listeners with normal audiograms, 12 of whom reported difficulty understanding speech in noise. Neither 40 percent time compression in quiet nor AM noise alone distinguished listeners with and without these difficulties. However, compressed speech presented in AM noise separated the two groups. This partial agreement between model predictions and behavior supports our MI-based stimulus design framework and motivates further evaluation of combined temporal and noise-based probes for CND detection.

0.25

Metadata-Conditioned Audio Transformers for Adaptive Respiratory Sound Classification

cs.SD cs.AIeess.AS ·2026-11-02 ·George Kontogiannis, Pantelis Tzamalis, Sotiris Nikoletseas
publishedbenchmark similarity 0.46
Abstract

Respiratory sound classification from auscultation recordings is confounded by heterogeneous acquisition conditions, including recording device, auscultation site, and patient characteristics, that introduce systematic variability unrelated to the underlying pathology. Although such metadata is often available, existing approaches either ignore it or rely on naïve fusion strategies that do not model how distinct metadata sources influence different components of the acoustic representation. We propose a family of metadata-conditioning mechanisms for the Audio Spectrogram Transformer (AST), progressing from gated residual fusion to Feature-wise Linear Modulation (FiLM) adapted to the Transformer architecture. We further introduce two novel variants: Token-Aware FiLM (TAFiLM), which applies distinct modulation to classification and patch tokens, and Soft-Factorized FiLM (SoftFiLM), which learns soft masks to align metadata factors with disentangled feature subspaces. Experiments on the ICBHI benchmark demonstrate consistent gains across all conditioning strategies. SoftFiLM achieves 64.11% on the official 4-class task (+3.94% over the baseline) and 72.40% on the 2-class task, establishing a new state-of-the-art on the 2-class task and competitive performance on the 4-class benchmark.

0.24

A Visual Grounding Benchmark for Retinal OCT with Multimodal Large Language Models

cs.CV ·2026-10-22 ·Ronald Fecso, José Morano, Botond Fazekas, Paul Widmann-Sedlnitzky, Dorota Himel +4 more
benchmarkcode/data similarity 0.46
Abstract · Under review at npj digital medicine

Multimodal large language models (MLLMs) can answer clinical questions about medical images, but trustworthy use requires visual grounding: models should localize the pathology they report rather than rely on spurious shortcuts. Whether MLLMs can visually ground clinical findings in retinal optical coherence tomography (OCT), the most widely used imaging modality in ophthalmology, remains largely unexplored. To address this gap, we introduce RetinaGroundBench, the first benchmark for biomarker visual grounding in retinal OCT. It comprises 815 B-scans exhaustively annotated by ophthalmologists with 4,537 bounding boxes covering 13 biomarkers across 8 diseases. Because MLLMs often fragment a single lesion into multiple partial predictions, we propose AggIoU, a metric that evaluates whether the union of overlapping predicted boxes covers the annotated region. Across 27 open-source MLLMs (0.8-38B parameters), we find that visual grounding remains largely unsolved: the best general-purpose model achieves a macro F1 of just 23.7%, with consistently low recall, despite reaching up to 73% balanced accuracy on biomarker presence questions. To narrow this gap, we developed RetGrounder, an MLLM fine-tuned using an OCT-specific strategy integrating grounding and textual information. Despite its relatively small size (8B), RetGrounder improves grounding F1 to 33.9%, a 43% relative improvement. Our benchmark provides a reference point for measuring progress in the field of OCT diagnosis with MLLMs.

0.30

Subjective Evaluation of DNN AND Auditory-Model-Based Hearing-Loss Compensation

eess.AS ·2026-09-23 ·Chuan Wen, Brent Nissens, Nele De Poortere, Morgan Thienpont, Matthias Inghels +3 more
similarity 0.46
Abstract

Outer-hair-cell (OHC) loss is a primary deficit of sensorineural hearing loss (SNHL), impairing cochlear amplification and frequency selectivity and thereby elevating hearing thresholds. Biophysically-inspired DNN-based hearing-aid (HA) algorithms have been proposed to compensate for OHC deficits and have shown clear benefits in objective speech intelligibility and quality metrics (e.g. HASPI, HASQI). However, comprehensive subjective validation of these benefits in human listeners is still missing. In this work, we present a subjective evaluation of a biophysically-inspired HA model targeting OHC deficits. The cochlear module of an auditory model was individualized based on each listener's pure-tone audiogram and integrated into a trainable system, which includes the personalized model and a normal-hearing reference model, and the resulting trained HA was evaluated using a Matrix test comparing intelligibility scores for unprocessed and HA-processed noisy speech. The results revealed a significant benefit of the HA model over the unprocessed condition in the range of +1 to +27%, providing behavioral confirmation of the efficacy of the HA model. This study closes the gap between objective and perceptual evidence for this new generation of DNN-based HA algorithms, paving the way for their integration into next-generation DNN-accelerated chips for hearables and hearing aids.

0.30