CS Paper Radar

Automated Optimization of Patient-Specific Electro-Anatomical Models Fitted to Cochlear Implant SCINSEV

Minh Q. Vu, Erin L. Bratu, Jack H. Noble

eess.SP ·submitted 2026-10-29 22:51 UTC · v1

Abstract

Purpose: Patient-specific electro-anatomical models (EAMs) of the implanted cochlea are crucial for auditory nerve fiber simulation in cochlear implant (CI) programming and neural health estimation. Fitting an EAM to the stimulation current induced non-stimulating electrode voltage (SCINSEV) currently requires manual expert adjustment or exhaustive search over precomputed forward solutions, neither of which scales to routine clinical use. We present an automated optimization pipeline that fits patient specific EAMs in minutes. Methods: Four compartment tissue label maps (perilymph, soft tissue, modiolus, and bone) derived from postoperative CT were used to construct a finite difference forward model, fitted to the measured SCINSEV by Gaussian process Bayesian optimization. Three reductions cut fitting cost: a coarsened grid with trilinear injection and readout at sub-voxel contact positions; solving half the stimulating contacts and completing three quarters of the matrix by reciprocity; and a Jacobian-based identifiability analysis reducing four resistivities to two. Each reduction was validated separately against the measurement's reciprocity residual and the reproducibility of the fit. Results: Across 43 implanted ears, fitting took a median of 2.6 minutes per ear. Median SCINSEV RMSE on the reduced-resolution objective was 0.069 mV, against 0.084 mV for grid search at a matched evaluation budget. Against an exhaustive full-resolution grid search requiring a median of 9.1 hours per ear, the pipeline reached statistically indistinguishable fitting error roughly 210x faster. Conclusion: Patient-specific cochlear EAM fitting can be performed at clinically practical timescales without expert supervision, removing a major computational barrier to patient-specific cochlear implant programming and cochlear simulation.

Closest papers

Nearest neighbours by meaning across the whole index.

Single-visit screening for intracochlear tissue growth validated against multi-visit electrical measurement changes

eess.SP ·2026-11-02 ·Minh Q. Vu, Erin L. Bratu, Jared A. Rybarczyk, Jack H. Noble
similarity 0.68
Abstract

Purpose: Tissue growth (TG) around cochlear implant electrodes raises impedance but is not reliably visible on CT scans. Routinely recorded stimulus current-induced non-stimulating electrode voltages (SCINSEVs) carry this information, but a single recording has no patient-specific reference. We present an algorithm for detecting signs of significant TG from a single SCINSEV measurement. Methods: TG is assumed to concentrate basally near the electrode insertion site, leaving the apical region mostly unaffected. A patient-specific forward model built from CT is fitted to the apical measurements and predicts the basal ones. The misfit score, T, measures each basal contact's signed relative misfit against the apical misfit, accounting for apical fit quality and measurement noise. An ear is flagged when two adjacent basal contacts cross a predetermined threshold. We compare T with T-delta, a model-free reference, tracking basal relative to apical SCINSEV change since the intra-operative recording, persisting over the last two visits. Results: T had a false-positive rate of 3% on growth-free ears. It agreed with T-delta in 81% of 68 ears (sensitivity 71%; specificity 86%; p = 6e-6). Over 200 patient-level two-fold splits, median held-out agreement was 78% at a false-positive rate of 5.1%. Conclusion: An apically fitted patient-specific model predicts basal SCINSEVs well enough to flag signs of significant TG at a single visit, without an intra-operative baseline. Detections largely agree with persistent multi-visit basal-versus-apical change, a surrogate ground truth for significant TG.

0.43

Improving Spectral Resolution via Simultaneous Extracochlear and Apical Ground Contacts: A Neural Simulation Study

eess.SP ·2026-10-30 ·Jared A. Rybarczyk, Erin L. Bratu, Robert F. Labadie, Jack H. Noble
similarity 0.62
Abstract

Objectives: While cochlear implants (CI) can provide excellent speech perception outcomes, speech recognition in noise remains a consistent problem for many patients due to channel interaction. Recent work shows the clinical feasibility of an apical return contact placed in the cochlear helicotrema, which presents new possibilities in terms of experimental stimulation schemes. This study explores the interactions between apical and extracochlear ground contacts, aiming to characterize the effects of dual ground usage on auditory nerve fiber (ANF) dynamics and determine their utility in improving spectral resolution. Design: 6 patients with CIs were used in this retrospective study. Volume conduction models encompassing patient specific electro-anatomical characteristics and ANF compartment models defining neural dynamics were used to generate activation thresholds for 75 evenly spaced fiber bundles throughout each modeled cochlea and for 4 different grounding configurations, including the use of combined grounds. We compare our intra-patient models in terms of threshold shifts and standard deviation of fiber proportions to determine the effects of ground configuration used on channel interaction. Results: For all 6 patients, we observe shifts in ANF activation thresholds for the combined ground models indicative of more specific fiber stimulation per contact. Additionally, our combined ground models exhibit reduced fiber proportion standard deviation for several contacts of the stimulating array when compared to the standard extracochlear ground configuration or apical ground configuration. Conclusions: The shifts in activation thresholds and reduction in standard deviations suggest that stimulation schemes utilizing extracochlear and apical grounds in conjunction can provide reduced channel interaction and enhanced spectral resolution for certain contacts in an array.

0.32

Towards Investigating Residual Hearing Loss: Quantification of Fibrosis in a Novel Cochlear OCT Dataset

cs.CV cs.AI ·2026-08-21 ·Julia Dietlmeier, Benjamin Greenberg, Wenxuan He, Teresa Wilson, Rubing Xing +8 more
top venuecode/dataunusual similarity 0.59
Abstract · Copyright 2026 IEEE. Personal use of this material is permitted. Citation/DOI: 10.1109/TBME.2025.3537868

Objective: Cochlear implants (CIs) are bionic prostheses that restores hearing via electrical stimulation of the auditory nerve. Hybrid CIs, which use electroacoustic stimulation (EAS), combine residual low-frequency acoustic hearing with CI electrical stimulation. Intracochlear fibrosis, which forms in response to the presence of the implant, may impede residual hearing function and gradually reduce the efficacy of EAS. It is therefore a translational objective to study the formation of cochlear fibrosis in rodents, with the goal of reducing fibrotic burden and improving outcomes for CI patients. Methods: We generate and annotate a novel dataset of optical coherence tomography (OCT) images from chronically implanted guinea pigs as part of an ongoing study focused on implant induced fibrosis. Objectively assessing fibrotic burden in this model, with high resolution and repeatability, presents an obvious use case for computer vision methods. Results: We present the results of several state-of-the-art semantic segmentation models and compare their efficacy for identifying cochlear fibrosis and other relevant annotations, using a new library of manually segmented OCT images. Conclusions: We find that the best performance is achieved by using a modified version of the well-known UNET architecture (which we term 2D-OCT-UNET) that operates on the upscaled OCT input resolution. Significance: For the first time, we have successfully applied computer vision techniques to an OCT dataset of implanted cochleae with fibrosis. Using this deep learning model, the cochlear fibrotic burden calculation can be reliably carried out as we verify in our experimental section. The dataset and the project code are available at: https://github.com/juliadietlmeier/CF-OCT-segmentation

0.84

Susceptibility source separation via Closed-form Alternating Newton-type Optimization

eess.IV ·2026-11-19 ·Ignacio Contreras-Zúñiga, Cristian Tejos, Carlos Milovic
similarity 0.49
Abstract

Quantitative Susceptibility Mapping (QSM) provides a bulk magnetic susceptibility estimate per voxel, so contributions from paramagnetic and diamagnetic sources within the same voxel partially cancel. Susceptibility source separation methods identify these compartments by fitting a three-pool complex exponential model to multi-echo gradient-echo (GRE) data. However, conventional voxel-wise fitting with general-purpose constrained solvers requires several hours per whole-brain volume and often fails in high-susceptibility regions. We present CANON-QSM (Closed-form Alternating Newton-type Optimization for QSM), a solver that reformulates the subproblems of the three-pool model and solves them alternately via exact closed-form updates and Newton-type steps, yielding a substantial per-voxel computational speedup. Both in silico and in vivo evaluations demonstrate not only a massive reduction in reconstruction time, completing a whole-brain volume in under two minutes, but also improved accuracy and robustness against artifacts in high-susceptibility regions. Finally, an echo-time analysis of the three-pool model shows that source separation is driven by second-order nonlinearities in signal decay and phase evolution rather than first-order bulk estimates.

0.25

THA-Flow Generative Model: Prosthesis Geometry Prediction from Preoperative CT

cs.CV ·2026-08-26 ·Yiping Wang, Jie Li, Jingyu Shen, Liao Wang
similarity 0.49
Abstract · 17 pages, 7 figures, 2 tables

Preoperative planning for total hip arthroplasty (THA) is commonly framed as selecting a single prosthesis configuration and placement for a patient's osseous anatomy. In practice, however, the same anatomy may admit several clinically reasonable solutions, making planning inherently a one-to-many problem that is better represented by a conditional probability distribution. We present THA-Flow, a conditional flow-matching model that generates three-dimensional prosthesis geometry directly from preoperative CT. Separate AutoencoderKL models compress preoperative bone anatomy and prosthesis geometry, while a three-dimensional UNet learns a rectified flow from Gaussian noise to the prosthesis latent space under spatial bone conditioning and optional structured prosthesis parameters. The retrospective cohort comprised 1,355 hips from 1,149 patients undergoing primary THA. Following rigid registration of postoperative CT to preoperative CT, the actual postoperative prostheses were transformed independently according to the pelvic and femoral registrations and represented as a dual-channel truncated signed distance field. The prosthesis autoencoder achieved a peak signal-to-noise ratio of 47.11 dB and a structural similarity index of 0.9964 on the validation set. Complete acetabular and femoral geometries were generated across seven major stem models representing 93.4% of the cohort. Repeated bone-conditioned sampling preserved component position, alignment, and the principal bone-prosthesis interfaces while allowing limited local geometric variation. To our knowledge, THA-Flow represents the first application of generative AI to three-dimensional surgical planning for THA.

0.28

Estimates of neural health using cochlear implant digital twins correlate with speech recognition

eess.SP ·2026-09-29 ·Erin L. Bratu, Andrea J. DeFreese, Katelyn A. Berg, Margaret Wilson, Aaron C. Moberly +2 more
similarity 0.49
Abstract

The cochlear implant is a neural prosthetic that uses an array of electrodes to directly stimulate auditory nerve fibers with electrical impulses. One factor that is known to impact outcomes is the quality of the electro-neural interface. In this work, we propose a pipeline that permits creating accurate and patient-specific digital twins that model the cochlear implant electro-neural interface. We leverage medical images and electrophysiological measurements from the patient's device for digital twin construction. We validate our digital twins by comparing predictions of neural response measurements to clinical measurements and speech recognition outcomes. Neural health estimated by the digital twin correlates strongly with word recognition rates (R=0.75, p<1e-5) in an analysis of 29 cases and sentence in noise recognition rates (R=0.78, p<1e-4) in an analysis of 21 cases. We also report preliminary findings with digital twin-based patient remapping with 6 subjects, where word recognition rates improved on average by 10 percentage points. These digital twins have the potential to provide clinicians with an unprecedented window into the electro-neural interface for individual cochlear implant recipients, which could lead to improved hearing outcomes when used as a foundation for program customization.

0.24

Speech-muscle coupling at jaw and ear electrodes: a volume-conductor model with orientation and electrode-count controls

cs.HC eess.SP ·2026-08-12 ·Carl Vincent Kho
code/data similarity 0.49
Abstract · Revised title, abstract and text. Reported both derived fibre models; clarified protocol history and current-normalization limits. Added a g…

Objective. We compared how strongly speech-muscle sources couple to electrodes on the jaw and around the ear, and tested sensitivity to source orientation, electrode count, and anatomical detail. Approach. Using reciprocity in MIDA (116 labelled compartments, 500 micrometres), we evaluated 22 electrode positions against ten segmented articulators. Muscle was modelled as both source and conducting tissue. Comparisons used equal electrode counts and a hemisphere orientation sweep, with anatomy-derived fibre models for temporalis and lateral pterygoid. Results. Orbicularis oris, buccinator, mentalis, depressor anguli oris, and platysma favoured the jaw at every sampled orientation and tested electrode subset. Temporalis showed a 2.57 dB ear advantage under the uniform sweep, reduced to 1.15 dB with the derived fibre field. Its jaw-minus-ear interval [-1.45, +5.46] dB crossed zero; 50.5% of four-site ear subsets favoured the ear. The derived lateral-pterygoid interval [-5.33, -1.12] dB favoured the ear at the fixed jaw basis. Both derived constructions have unresolved anatomical limitations. Simplifying non-muscle soft-tissue conductivities preserved montage assignments while changing gaps by up to 3.27 dB. Significance. In this head model, jaw placement better captures lip and chin activity. Ear-side preferences depend on source assumptions and electrode selection. Targeted four-site placement improved lateral-pterygoid coupling by 1.07 dB over the median random ear montage. These coupling predictions require experimental testing.

0.24

A FEM-Based Surrogate Modelling and Optimization Framework for Physics-Constrained Electromagnetic Coil Design

cs.LG ·2026-08-19 ·Yucheng Liu
benchmark similarity 0.48
Abstract · 18 pages, 9 figures

This work evaluates surrogate-assisted optimization of a seven-parameter current-excited coil--core benchmark subject to geometric, manufacturing, and separate core and copper mass constraints. A Python--MPh--COMSOL workflow couples a two-dimensional axisymmetric finite-element method (FEM) model to a Matern 5/2 Gaussian-process (GP) probabilistic surrogate. Here, physics-constrained denotes a design problem evaluated by a governing-equation FEM model and restricted by explicit physical, geometric, manufacturing, and material-allocation constraints; it does not denote a physics-informed GP architecture. Sequential Bayesian optimization (BO) ranks candidates using expected improvement (EI), and every reported incumbent is verified by FEM. Five paired runs show that optimizer ranking depends on the available FEM-evaluation budget: EI--BO improves rapidly at small continuation budgets, COBYLA is stronger at the earliest checkpoint, and BOBYQA attains the highest mean terminal response. A retrospective finite-pool study further finds no robust endpoint advantage of EI over posterior-mean ranking on this smooth response surface. The broader result is that early progress, terminal response, information use, and wall-clock cost can favor different methods in simulation-driven design. A selected-design check at a common total current preserves the observed BOBYQA--COBYLA--EI-BO ordering. The conclusions nevertheless remain conditional on this axisymmetric benchmark and do not establish a fixed-current optimum, fixed-power performance, or electrical-efficiency superiority.

0.29