CS Paper Radar

Susceptibility source separation via Closed-form Alternating Newton-type Optimization

Ignacio Contreras-Zúñiga, Cristian Tejos, Carlos Milovic

eess.IV ·submitted 2026-11-19 18:27 UTC · v1

Abstract

Quantitative Susceptibility Mapping (QSM) provides a bulk magnetic susceptibility estimate per voxel, so contributions from paramagnetic and diamagnetic sources within the same voxel partially cancel. Susceptibility source separation methods identify these compartments by fitting a three-pool complex exponential model to multi-echo gradient-echo (GRE) data. However, conventional voxel-wise fitting with general-purpose constrained solvers requires several hours per whole-brain volume and often fails in high-susceptibility regions. We present CANON-QSM (Closed-form Alternating Newton-type Optimization for QSM), a solver that reformulates the subproblems of the three-pool model and solves them alternately via exact closed-form updates and Newton-type steps, yielding a substantial per-voxel computational speedup. Both in silico and in vivo evaluations demonstrate not only a massive reduction in reconstruction time, completing a whole-brain volume in under two minutes, but also improved accuracy and robustness against artifacts in high-susceptibility regions. Finally, an echo-time analysis of the three-pool model shows that source separation is driven by second-order nonlinearities in signal decay and phase evolution rather than first-order bulk estimates.

Closest papers

Nearest neighbours by meaning across the whole index.

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.62
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

Quadratic Unconstrained Binary Optimization for Sparse Magnetoencephalography Source Localization

eess.SP ·2026-08-13 ·Arim Ryou, Kiwoong Kim
benchmark similarity 0.61
Abstract · 16 pages, 4 figures

Magnetoencephalography (MEG) source localization is an ill-posed inverse problem because distinct cortical source configurations can produce similar sensor-level fields. We formulate sparse multi-source localization as a quadratic unconstrained binary optimization (QUBO) problem combined with residual-aware candidate screening. Candidate source-location groups are generated from the sensor-space residual, fixed sensor-space templates are estimated for the resulting candidates, and active templates are jointly selected using data-fit, pairwise template interactions, and soft-cardinality terms. We evaluate the method using classical simulated annealing in controlled synthetic MEG simulations, primarily under a two-source condition, and compare it with MNE, dSPM, MxNE, LCMV, and RAP-MUSIC. Across 100 main-benchmark trials, QUBO achieved a mean cardinality-aware localization error of 8.45 mm, compared with 22.35 mm for MxNE, the best-performing baseline according to this metric, corresponding to a 62.2% reduction. The composite metric adds a 50 mm penalty per unit of source-count mismatch before normalization by the true source count. Because MxNE returned only one source in 35 trials, the reported reduction reflects both spatial localization and source-count performance. In separate sensitivity experiments, QUBO remained competitive across the tested sensor-noise and source-count conditions, although RAP-MUSIC performed comparably to or better than QUBO in some low-noise and three-source settings. The present experiments use classical simulated annealing and do not evaluate quantum hardware or claim quantum advantage. The resulting binary quadratic objective admits a direct Ising representation, enabling future evaluation on quantum-annealing and hybrid backends.

0.10

dMRI-F: A Foundation Model for Generalizable Diffusion MRI Analysis from Sparse Acquisitions

cs.CV ·2026-10-13 ·Xi Zhu, Yijie Li, Xiaofan Wang, Wei Zhang, Huafu Chen +2 more
similarity 0.59
Abstract

Diffusion MRI (dMRI) probes water diffusion within the brain, providing unique information about tissue microstructure and white matter connectivity. High-quality dMRI enables advanced and accurate analyses but demands dense acquisitions, resulting in long scan times and hardware constraints that are often infeasible. Further, dMRI requires dedicated computational methods to support diverse analysis tasks (e.g., parcellation, registration, and synthesis) for both neuroscientific and clinical applications. Here, we present dMRI-F, a foundation model that unifies dMRI data enhancement and downstream tasks across diverse acquisitions and populations, while requiring only minimal acquisition input. dMRI-F is pre-trained with a q-space masked reconstruction task: predicting densely sampled multi-shell data from only six volumes. It learns generalizable latent feature representations of dMRI data, which serve as a core foundation for adapting to diverse downstream tasks, including brain parcellation, brain registration, and cross-modal synthesis. Across nine independently acquired datasets, we demonstrate that dMRI-F outperforms state-of-the-art methods with robust generalization across acquisitions, populations, and tasks. Our results demonstrate dMRI-F's versatility as a general-purpose framework that enables diverse dMRI applications from low-cost, sparse acquisitions.

0.15

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization

eess.IV ·2026-11-03 ·Rushdi Rusho, Jyothi Rikhab Chand, Steve R. Kecskemeti, James H. Holmes, Mathews Jacob
similarity 0.58
Abstract · 5 pages, 3 figures

Quantitative MRI methods can offer tissue parameter maps (e.g. T1) that are comparable across scanners, sessions and subjects, together with multiple contrast-weighted images from a single scan. However, most data are acquired at 1 mm, which limits their use in neurodegenerative diseases that affect fine brain structures. We introduce, to our knowledge, the first diffusion-model-based reconstruction for quantitative MRI at 0.5 mm isotropic resolution from scans of less than 5 minutes, which has eightfold smaller voxel volume than clinical protocols. The key idea is to apply the prior to the synthesized contrast images rather than to the subspace coefficients. The prior is then independent of the temporal basis and the sequence, which improves generalization and allows a 2-D multiscale energy (MuSE) model trained on grayscale CelebA face images to be used without any MRI training data. The explicit energy makes reconstruction MAP estimation by a step-size-free majorize-minimize algorithm that regularizes a rotating subset of contrasts along different axes, which makes 3-D multi-contrast reconstruction tractable. For 3-D radial MPnRAGE at 7 T in 4.3 min, MuSE reduced the phantom NRMSE from 0.133 (CG-SENSE) and 0.091 (L1-wavelet) to 0.074 and the WM T1 interquartile range from 117 and 47 ms to 38 ms, and it was demonstrated in vivo at 7 T.

0.24

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.57
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36

MnemoDyn: Learning Resting State Dynamics from 40K FMRI sequences

cs.LG ·2026-08-25 ·Sourav Pal, Viet Luong, Hoseok Lee, Tingting Dan, Guorong Wu +3 more
published similarity 0.56
Abstract · ICLR 2026

We present a dynamical-systems based model for resting-state functional magnetic resonance imaging (rs-fMRI), trained on a dataset of roughly 40K rs-fMRI sequences covering a wide variety of public and available-by-permission datasets. While most existing proposals use transformer backbones, we utilize multi-resolution temporal modeling of the dynamics across parcellated brain regions. We show that MnemoDyn is compute efficient and generalizes very well across diverse populations and scanning protocols. When benchmarked against current state-of-the-art transformer-based approaches, MnemoDyn consistently delivers superior reconstruction quality. Overall, we find that with such large-scale pre-training on (non-proprietary) rs-fMRI datasets, we get a highly performant model for various downstream tasks. Our results also provide evidence of the efficacy of the model on small sample size studies which has implications for neuroimaging studies at large where resting state fMRI is a commonly acquired imaging modality.

0.52

UniField++: A Unified Agentic Framework with Loop Reasoning for MRI Field-Strength Enhancement

cs.CV ·2026-10-16 ·Yiyang Lin, Chenhui Wang, Tianliang Yao, Pengli Zhu, Shuaibo Li +3 more
code/data similarity 0.55
Abstract · 10 pages, 6 figures, 8 tables

MRI field-strength enhancement seeks to combine the accessibility of low-field scanners with the image quality of high-field scanners. Yet, existing methods remain prone to anatomical hallucinations, as uniform processing leaves difficult brain regions insufficiently examined and scarce paired data limit their learning of how tissue contrast and anatomical visibility change across field strengths. To address these challenges, we propose UniField++, a two-agent framework that unifies enhancement tasks across multiple field-strength transitions, including 64mT-to-3T and 3T-to-7T. Unified learning allows both the VLM-based planner and the flow-matching-based enhancer to draw on field-dependent image characteristics observed across tasks, rather than relying on a single transition. Trained with radiologists' annotations of hallucination-prone regions and corresponding correction plans, the planner predicts regional risk and formulates targeted restoration strategies. Guided by these plans, the enhancer performs loop reasoning along the flow-matching trajectory, repeatedly processing high-risk regions for additional refinement. Together, cross-transition learning and risk-guided refinement support anatomically faithful enhancement across field strengths. Across the evaluated tasks, UniField++ improves PSNR by an average of 2.74 dB and SSIM by 14.05 percentage points over comparison methods, with corresponding gains of 3.97 dB and 13.92 percentage points over the ablation baseline. It also maintains enhancement quality on an external cohort with an unseen field strength and improves downstream whole-brain segmentation Macro Dice by an average of 0.1457 over the original low-field images. Code is available at https://github.com/CUHK-AIM-Group/UniField_plusplus.

0.31

SGAM: Shared Gaussian Geometry with Implicit Amplitude Modeling for Scan-Specific 3D Multi-Contrast MRI Reconstruction

cs.CV ·2026-09-21 ·Jingran Xu, Dong Liang, Hairong Zheng, Yuanyuan Liu, Yanjie Zhu
similarity 0.55
Abstract

Three-dimensional (3D) multi-contrast magnetic resonance imaging (MCMRI) provides rich anatomical and quantitative information but requires long acquisition times, motivating k-space undersampling. However, reconstruction of large volumetric datasets imposes substantial computational and memory demands. To address this challenge, we propose SGAM, a memory-efficient, scan-specific framework for joint full-volume 3D MCMRI reconstruction. SGAM is based on a shared-geometry Gaussian representation in which amplitudes are modeled by a multi-output implicit neural representation (INR) and contrast-specific phases by explicit variables. This design exploits common anatomical structure across contrasts while preserving contrast-specific signal variations. The representation is jointly optimized using only the acquired multi-coil k-space without external training data. Experiments showed that SGAM consistently outperformed the comparison methods across imaging tasks and acceleration factors, with greater improvements under stronger undersampling. SGAM also achieved a favorable balance between reconstruction quality and computational cost, demonstrating its effectiveness for 3D multi-contrast MRI reconstruction.

0.12