CS Paper Radar

Speech-muscle coupling at jaw and ear electrodes: a volume-conductor model with orientation and electrode-count controls

Carl Vincent Kho

cs.HC eess.SP ·submitted 2026-08-12 02:40 UTC · v2
code/data

Abstract

Objective. We compared how strongly speech-muscle sources couple to electrodes on the jaw and around the ear, and tested sensitivity to source orientation, electrode count, and anatomical detail. Approach. Using reciprocity in MIDA (116 labelled compartments, 500 micrometres), we evaluated 22 electrode positions against ten segmented articulators. Muscle was modelled as both source and conducting tissue. Comparisons used equal electrode counts and a hemisphere orientation sweep, with anatomy-derived fibre models for temporalis and lateral pterygoid. Results. Orbicularis oris, buccinator, mentalis, depressor anguli oris, and platysma favoured the jaw at every sampled orientation and tested electrode subset. Temporalis showed a 2.57 dB ear advantage under the uniform sweep, reduced to 1.15 dB with the derived fibre field. Its jaw-minus-ear interval [-1.45, +5.46] dB crossed zero; 50.5% of four-site ear subsets favoured the ear. The derived lateral-pterygoid interval [-5.33, -1.12] dB favoured the ear at the fixed jaw basis. Both derived constructions have unresolved anatomical limitations. Simplifying non-muscle soft-tissue conductivities preserved montage assignments while changing gaps by up to 3.27 dB. Significance. In this head model, jaw placement better captures lip and chin activity. Ear-side preferences depend on source assumptions and electrode selection. Targeted four-site placement improved lateral-pterygoid coupling by 1.07 dB over the median random ear montage. These coupling predictions require experimental testing.

Comment
Revised title, abstract and text. Reported both derived fibre models; clarified protocol history and current-normalization limits. Added a graphical abstract, 116 conductivity rows and a volume-only Supplementary Figure S1. Existing numerical results and numbered figure assets are unchanged. Code: https://github.com/Somach-Systems-Inc/ear-emg-forward-model

Closest papers

Nearest neighbours by meaning across the whole index.

A Device to Control and Manipulate Occlusion Effects for Own Voice Perception Studies

eess.AS ·2026-09-11 ·Rouben Rehman, Simon Kersten, Aron Schliep, Janina Fels
similarity 0.56
Abstract

The occlusion effect (OE) refers to changes of the eardrum sound pressure through ear canal occlusion. It consists of two phenomena: an insertion loss (IL) attenuating air-conducted sounds, and an occlusion gain (OG) amplifying bone-conduction. Perceptual research on this is hindered by high variability of the OE across individuals, complicating repeatable presentation of precise OE conditions. Consequently, a method to control OE conditions reproducibly during perceptual experiments is needed. For such investigations, the system must enable separate control of IL and OG. We present an approach based on modified commercial earmuffs with integrated microphones. The design integrates dedicated impedance measurements and the derivation of digital filters, which are applied to the microphone signals to emulate arbitrary OE curves. The system is evaluated objectively through appropriate measurements. Results show that the headphones' inherent OG is guaranteed to be below 6dB above 115Hz, falling below 0dB above 155Hz. Emulation is shown to work accurately over the entire frequency range of interest. Limitations arise mainly due to a slight residual inherent OG for deep voices and the processing delay of the system. Future work will focus on the perceptual evaluation of the system and its application in perceptual studies.

0.20

Sensing Bone-Conducted Speech with Earbuds

eess.AS ·2026-09-02 ·Christoph Weyer, Peter Jax
published similarity 0.56
Abstract · 14 pages, 12 figures, journal

Clear capture of the wearer's own voice (OV) is essential when using earbuds for mobile communication. However, OV capture remains challenging in noisy environments. Bone-conducted (BC) speech, which can be sensed as vibrations of the earbud housing, can be used to improve OV capture. However, neither bandwidth nor spatial characteristics of OV-induced earbud vibrations have been analyzed in detail, despite both characteristics being relevant, e.g., for sensor choice and placement. This study investigates both characteristics, based on measurements with two earbud models. Spectrally, results indicate that OV-induced earbud vibrations exhibit a low-pass characteristic, with a steep roll-off of -93 dB per decade above 400 Hz. Thus, sensors with comparatively low noise floors are required to sense the vibrations above \SI{1}{\kilo\hertz}. Spatially, results indicate that the earbuds mainly vibrate in and out of the ear canal entrance, with high consistency between subjects and fits. Simulations confirm that this enables capture of the high-power vibrations below 400 Hz by a single-axis sensor with less than 1.5 dB mean attenuation.

0.39

Improving Spectral Resolution via Simultaneous Extracochlear and Apical Ground Contacts: A Neural Simulation Study

eess.SP ·2026-10-30 ·Jared A. Rybarczyk, Erin L. Bratu, Robert F. Labadie, Jack H. Noble
similarity 0.53
Abstract

Objectives: While cochlear implants (CI) can provide excellent speech perception outcomes, speech recognition in noise remains a consistent problem for many patients due to channel interaction. Recent work shows the clinical feasibility of an apical return contact placed in the cochlear helicotrema, which presents new possibilities in terms of experimental stimulation schemes. This study explores the interactions between apical and extracochlear ground contacts, aiming to characterize the effects of dual ground usage on auditory nerve fiber (ANF) dynamics and determine their utility in improving spectral resolution. Design: 6 patients with CIs were used in this retrospective study. Volume conduction models encompassing patient specific electro-anatomical characteristics and ANF compartment models defining neural dynamics were used to generate activation thresholds for 75 evenly spaced fiber bundles throughout each modeled cochlea and for 4 different grounding configurations, including the use of combined grounds. We compare our intra-patient models in terms of threshold shifts and standard deviation of fiber proportions to determine the effects of ground configuration used on channel interaction. Results: For all 6 patients, we observe shifts in ANF activation thresholds for the combined ground models indicative of more specific fiber stimulation per contact. Additionally, our combined ground models exhibit reduced fiber proportion standard deviation for several contacts of the stimulating array when compared to the standard extracochlear ground configuration or apical ground configuration. Conclusions: The shifts in activation thresholds and reduction in standard deviations suggest that stimulation schemes utilizing extracochlear and apical grounds in conjunction can provide reduced channel interaction and enhanced spectral resolution for certain contacts in an array.

0.32

Finger-to-Ear ECG: Systematic Evaluation of an Earbud-Based Cardiac Monitoring Approach

cs.HC ·2026-09-21 ·Philipp Lepold, Paula Breitling, Jonas Hummel, Tobias Röddiger, Michael Beigl
published similarity 0.53
Abstract

Ear-ECG enables unobtrusive cardiac monitoring, but existing approaches often struggle with low signal amplitudes and limited morphology preservation. We evaluate a finger-to-ear ECG paradigm that combines an in-ear electrode with a rear housing finger-contact electrode in a speaker-equipped earbud. A study with 30 participants investigated four finger-to-ear electrode geometries against chest-reference ECG and additionally assessed robustness under music playback, talking, and walking disturbances. Left-finger configurations achieved R peak detection F1-scores >99% with high agreement of key ECG morphology features. In contrast, right finger configurations as well as walking led to severe signal degradation. The results reveal a trade-off: while cross-body setups provided the highest signal fidelity, users preferred same-side contacts for comfort reasons. This establishes finger-to-ear ECG as a robust, morphology-aware paradigm for opportunistic sensing in earables.

0.38

Side-Vent Design for Microphone-Based Mechanomyography Sensors: Modeling and Experimental Evaluation of Contact Dependence

cs.HC ·2026-10-11 ·Cong Liu, Xiao Jin, Zhenhua Yu
similarity 0.51
Abstract · 10 pages, 9 figures, 1 table. Submitted to IEEE Sensors Journal

Wearable muscle sensing for rehabilitation, assistive robotics, and electrical-stimulation feedback needs mechanomyography sensors less sensitive to fit changes during wear. In microphone-based mechanomyography, cavity pressure depends on rim contact, a dependence housing design has rarely targeted. This study evaluates a side-vented housing, whose vent opens a pressure-relief path in parallel with the rim to lower contact dependence, and quantifies the acoustic-gain cost. Thermoviscous finite-element simulations compared twenty cavity configurations under prescribed source motion. Paired bench sweeps over 10-200 Hz on both housings compared direct contact with a Gap-ring spacer, a radially grooved spacer ring. At 100 Hz, side venting reduced the simulated acoustic-gain variation across 0.10-0.50 mm rim clearances from 25.8 to 10.0 dB and cost 5.5 dB of gain at 0.20 mm clearance. Velocity fields and branch-flow calculations identified this path. At the higher speaker drive level, the Gap-ring spacer caused median attenuations of 13.6 dB (vented) and 30.1 dB (unvented) relative to direct contact. In this front end, a 35.9-dB signal-gain increase at 100 Hz raised the calculated operational-amplifier voltage-noise gain by 1.6 dB. A single-participant demonstration of paced elbow flexion and extension compared envelope timing and spectra between housings, finding similar envelope timing (correlation 0.935) and broadly similar spectra (correlation 0.956). Vent area trades acoustic gain against contact dependence and can therefore serve as a housing design parameter.

0.31

Single-visit screening for intracochlear tissue growth validated against multi-visit electrical measurement changes

eess.SP ·2026-11-02 ·Minh Q. Vu, Erin L. Bratu, Jared A. Rybarczyk, Jack H. Noble
similarity 0.50
Abstract

Purpose: Tissue growth (TG) around cochlear implant electrodes raises impedance but is not reliably visible on CT scans. Routinely recorded stimulus current-induced non-stimulating electrode voltages (SCINSEVs) carry this information, but a single recording has no patient-specific reference. We present an algorithm for detecting signs of significant TG from a single SCINSEV measurement. Methods: TG is assumed to concentrate basally near the electrode insertion site, leaving the apical region mostly unaffected. A patient-specific forward model built from CT is fitted to the apical measurements and predicts the basal ones. The misfit score, T, measures each basal contact's signed relative misfit against the apical misfit, accounting for apical fit quality and measurement noise. An ear is flagged when two adjacent basal contacts cross a predetermined threshold. We compare T with T-delta, a model-free reference, tracking basal relative to apical SCINSEV change since the intra-operative recording, persisting over the last two visits. Results: T had a false-positive rate of 3% on growth-free ears. It agreed with T-delta in 81% of 68 ears (sensitivity 71%; specificity 86%; p = 6e-6). Over 200 patient-level two-fold splits, median held-out agreement was 78% at a false-positive rate of 5.1%. Conclusion: An apically fitted patient-specific model predicts basal SCINSEVs well enough to flag signs of significant TG at a single visit, without an intra-operative baseline. Detections largely agree with persistent multi-visit basal-versus-apical change, a surrogate ground truth for significant TG.

0.43

ElectroCalm: Investigating User Experience and Physiological Responses to Multi-Node Transcutaneous Electrical Stimulation for Stress Modulation

cs.HC ·2026-10-15 ·Yoon Kyung Shon, Pablo E. Paredes
published similarity 0.49
Abstract · 25 pages, 6 figures, to appear in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies, Vol. 10, No. 4, Decem…

Transcutaneous Electrical Stimulation (TES) for stress modulation has largely focused on vagus nerve stimulation at the neck, yet two questions remain underexplored: how users experience electrotactile sensations at this sensitive site, and whether electrotactile feedback itself can function as a haptic stress intervention. To investigate this gap, we applied an 8-node TES array to two body sites during a cognitively demanding 2-back task: the neck, a site used in prior vagal TES research for its anatomical proximity to the cervical vagus nerve, and the arm, the most common haptic wearable site, which primarily provides cutaneous electrotactile sensation without vagal access. In a usability study, both sites were rated as comparably comfortable without disrupting task performance, though the same stimulation was interpreted differently across sites. A second study assessing the physiological effects of active versus inactive stimulation under identical electrode attachment revealed that only neck TES produced cortical and autonomic changes consistent with stress modulation, while arm TES did not differ from inactive conditions. These findings suggest that neck TES can be acceptable despite the site's sensitivity, and that both the physiological effects and the sensory experience of TES depend on placement.

0.43

A Dry-Contact Ear-EEG System With Continuous Electrode-Skin Impedance Mismatch Monitoring for Motion Artifact Cancellation Using DRL Stimulus

eess.SP eess.SY ·2026-09-02 ·Lohan Atapattu, Sajitha Madugalle, Imasha Nethmal, Erandee Jayathilaka, Avishka Herath +4 more
published similarity 0.49
Abstract · 5 pages, 4 figures, accepted for presentation at IEEE BioCAS 2026

Dry-contact ear-electroencephalography (Ear-EEG) enables wearable neural monitoring. However, motion induced electrode-skin impedance (ESI) mismatches between electrodes can severely degrade signal quality. To the best of our knowledge, this paper presents the first proof-of-concept dry-contact EarEEG system that uses a driven-right-leg (DRL) stimulus for continuous ESI mismatch monitoring, enabling online adaptive motion artifact cancellation. A 1 kHz sinusoidal stimulus is injected through the DRL electrode. The resulting response to the injected carrier is separated from the EEG using bandpass filtering and demodulation, and then used to extract the ESI mismatch information as the reference input for a normalized least-mean-square adaptive filter followed by a Hampel filtering stage. To evaluate artifact suppression and preservation of neural activity, alpha-band EEG activity was analyzed involving four healthy participants performing head nodding, electrode tapping, and jaw clenching. The system achieved artifact power reductions of 6.5, 12.6, and 9.0 dB (77.6%, 92.8%, and 86.4%, respectively) while alpha-band modulation remained clearly observable after processing. This demonstrates the feasibility of DRL-stimulusbased ESI mismatch monitoring for motion artifact cancellation in wearable dry-contact Ear-EEG.

0.38