CS Paper Radar

Finger-to-Ear ECG: Systematic Evaluation of an Earbud-Based Cardiac Monitoring Approach

Philipp Lepold, Paula Breitling, Jonas Hummel, Tobias Röddiger, Michael Beigl

cs.HC ·submitted 2026-09-21 13:02 UTC · v1
published

Abstract

Ear-ECG enables unobtrusive cardiac monitoring, but existing approaches often struggle with low signal amplitudes and limited morphology preservation. We evaluate a finger-to-ear ECG paradigm that combines an in-ear electrode with a rear housing finger-contact electrode in a speaker-equipped earbud. A study with 30 participants investigated four finger-to-ear electrode geometries against chest-reference ECG and additionally assessed robustness under music playback, talking, and walking disturbances. Left-finger configurations achieved R peak detection F1-scores >99% with high agreement of key ECG morphology features. In contrast, right finger configurations as well as walking led to severe signal degradation. The results reveal a trade-off: while cross-body setups provided the highest signal fidelity, users preferred same-side contacts for comfort reasons. This establishes finger-to-ear ECG as a robust, morphology-aware paradigm for opportunistic sensing in earables.

DOI
10.1145/3830727.3834819

Closest papers

Nearest neighbours by meaning across the whole index.

A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

cs.AR eess.SPeess.SY ·2026-11-05 ·Wei Ren, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang +2 more
similarity 0.57
Abstract · 11 pages, 9 figures

Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG--SCG--DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

0.24

Calmables: Demonstrating Closed-Loop Infrared Earables for Thermal Biofeedback and Relaxation Support

cs.HC ·2026-09-16 ·Valeria Zitz, Michael Küttner, Jonas Hummel, Taku Inoue, Tobias Rödiger +1 more
published similarity 0.57
Abstract

We present Calmables, a walk-up demo of a closed-loop infrared earable that uses smart-ring heart rate to create subtle, ear-localized warming cues. Building on work on thermal comfort and in-ear infrared stimulation, Calmables explores warmth at the ear as a biosignal-adaptive cue for brief recovery moments following acute activation. A smartphone first establishes an individual resting baseline and derives a personalized heart-rate threshold, while the earable controller independently enforces an over-temperature cut-off and communication fail-safes. During the guided demo flow, attendees complete a brief rapid-breathing activation phase until their heart rate reaches the personalized threshold. This triggers an ear-localized warming cue followed by a short relaxation phase, while physiological changes are displayed on a live dashboard. Attendees can also manually explore different infrared stimulation intensities. To contextualize the demo, we report preliminary placebo-controlled UX ratings from 18 participants: participants rated the active prototype higher on perceived relaxation and perceived recovery support than an identical-looking placebo. Together, the demo illustrates how infrared earables can make physiological feedback tangible through subtle, biosignal-adaptive thermal cues.

0.59

EITWatch: Smartwatch-Integrated Planar Electrical Impedance Tomography for Hand Gesture Recognition

cs.HC ·2026-08-29 ·Xuanyou Liu, Novel Alam, Karan Ahuja
top venuecode/data similarity 0.57
Abstract · 7 pages, 6 figures, 2 tables. Accepted to UIST '26. Code: https://github.com/XuanyouLiu/EITWatch_Hardware

Wrist Electrical Impedance Tomography (EIT) senses hand gestures from muscle- and tendon-driven impedance changes, but prior wrist-EIT systems require electrode coverage beyond the watch-back contact patch and separate analog front ends. We present EITWatch, the first wrist-EIT system built around smartwatch case-back geometry, asking whether this contact patch alone can support gesture recognition: eight planar electrodes in a 31 mm ring acquire 35 impedance measurements at 48 Hz. Because a planar array cannot encircle the wrist, EITWatch uses multi-depth scanning to sample multiple source-sink distances and current paths; it beat matched adjacent injection by 15.1/10.4 percentage points (macro/micro) across all 12 participants. In a prompted study, within-session leave-one-round-out accuracy reached 91.4%/92.5% (window/trial) for six macro-gestures, and 90.1%/91.5% (window/segment) for five micro-gestures plus relax; window-level cross-session and leave-one-user-out transfer reached 73.2%/70.4% and 63.1%/55.3% (macro/micro).

0.58

A Dry-Contact Ear-EEG System With Continuous Electrode-Skin Impedance Mismatch Monitoring for Motion Artifact Cancellation Using DRL Stimulus

eess.SP eess.SY ·2026-09-02 ·Lohan Atapattu, Sajitha Madugalle, Imasha Nethmal, Erandee Jayathilaka, Avishka Herath +4 more
published similarity 0.56
Abstract · 5 pages, 4 figures, accepted for presentation at IEEE BioCAS 2026

Dry-contact ear-electroencephalography (Ear-EEG) enables wearable neural monitoring. However, motion induced electrode-skin impedance (ESI) mismatches between electrodes can severely degrade signal quality. To the best of our knowledge, this paper presents the first proof-of-concept dry-contact EarEEG system that uses a driven-right-leg (DRL) stimulus for continuous ESI mismatch monitoring, enabling online adaptive motion artifact cancellation. A 1 kHz sinusoidal stimulus is injected through the DRL electrode. The resulting response to the injected carrier is separated from the EEG using bandpass filtering and demodulation, and then used to extract the ESI mismatch information as the reference input for a normalized least-mean-square adaptive filter followed by a Hampel filtering stage. To evaluate artifact suppression and preservation of neural activity, alpha-band EEG activity was analyzed involving four healthy participants performing head nodding, electrode tapping, and jaw clenching. The system achieved artifact power reductions of 6.5, 12.6, and 9.0 dB (77.6%, 92.8%, and 86.4%, respectively) while alpha-band modulation remained clearly observable after processing. This demonstrates the feasibility of DRL-stimulusbased ESI mismatch monitoring for motion artifact cancellation in wearable dry-contact Ear-EEG.

0.38

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.55
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32

A Co-Located MMG-FES Wearable Interface for Action-Updated State-Gated Stimulation

cs.HC ·2026-10-11 ·Cong Liu, Xiao Jin, Zhenhua Yu
similarity 0.54
Abstract · 9 pages, 8 figures. Submitted to IEEE Robotics and Automation Letters

Functional electrical stimulation (FES) assists movement, but fixed schedules cannot track how a repeatedly activated muscle changes, and surface electromyography (EMG) near the stimulation electrodes is often obscured by artifacts. Prior work recorded mechanomyography (MMG) passively during closed-loop FES cycling and estimated FES-induced fatigue or predicted fatigue for FES control, without gating stimulation with stimulated-site MMG. In this study, we present VG-FES, a wearable module co-locating microphone-based MMG, programmable charge-balanced biphasic stimulation, and embedded state-gated control at one on-skin thigh site. After each action, we compare rectus femoris (RF) mean power frequency (MPF) with an early-session baseline of the same direction, giving a relative state. A threshold on its window means enables fixed-duration bursts separated by rest periods. During onboard stimulation, MMG remained recordable, whereas near-site EMG was artifact-dominated. Under prolonged external stimulation, cycle-wise MMG tracked an independent local-pressure reference (Spearman rho = 0.968). In leave-one-session-out evaluation on 2284 squat actions (11 sessions, eight participants), MMG-based action segmentation reached an event-detection F1 of 0.923 and direction classification a balanced accuracy of 0.925. Online, over 15.69 min of self-paced squats, one participant received four bursts while MMG acquisition and action monitoring continued. Mechanical feedback from the stimulated site offers wearable FES and assistive robotics a per-action basis for state-gated stimulation.

0.40

Unlocking with the Heart: Investigating User Perceptions of ECG-Based Biometric Authentication

cs.HC cs.CRcs.CYcs.ET+1 ·2026-10-29 ·Farnaz Farid, Linet Momposhi, Tamara Watson, Alana Maurushat, Abubakar Bello +1 more
survey similarity 0.53
Abstract · 28

Password-based authentication remains challenging for many users, especially for those who face usability and accessibility issues. The burden of maintaining security can cause user fatigue, frustration and non-engagement. To address these issues, we conducted a pilot study to assess ECG-based biometric authentication as a passwordless alternative and to gather adult participants' perspectives on this approach. The research consisted of a survey study, an authentication prototype and a follow-up usability experience questionnaire. Our approach combined an online survey of 337 adults examining authentication practices and perceptions, with a separate usability evaluation in which 49 participants interacted with a simulated ECG-authentication and password interface in a health-care application prototype, then completed a post-test usability test questionnaire. The survey examined how adults across age groups use and perceive various authentication techniques, their experiences with biometrics, their views on security and convenience, and their willingness to adopt ECG authentication. In parallel, the usability prototype and questionnaire captured participants' responses after hands-on interaction with an ECG authentication prototype.

0.26

Wearable ECG Quality Assessment: A Deep Learning and Ambulatory Context-Awareness Approach

cs.AI eess.SP ·2026-09-24 ·Xiaopeng Mao, Marike Weisbjerg, Sadasivan Puthusserypady
similarity 0.53
Abstract

This paper presents and evaluates a Deep Learning-based (DL-based) Signal Quality Assessment (SQA) model to distinguish between clean and noisy ambulatory Electrocardiograms (ECG). The model is trained on Copenhagen Center for Health Technology-Contextualized Arrhythmia Database (CACHET-CADB), which, to the best of our knowledge, is the first ambulatory ECG database with both physical and patient-reported contextual data. The model shows stable performance on different databases such as MIT-databases and the latest PyhsioNet/Cinc Challenge 2021 databases. Subsequently, the paper demonstrates how complicated ECG noise can be investigated by the SQA model and the physical contextual data.

0.08