CS Paper Radar

A Co-Located MMG-FES Wearable Interface for Action-Updated State-Gated Stimulation

Cong Liu, Xiao Jin, Zhenhua Yu

cs.HC ·submitted 2026-10-11 13:29 UTC · v1

Abstract

Functional electrical stimulation (FES) assists movement, but fixed schedules cannot track how a repeatedly activated muscle changes, and surface electromyography (EMG) near the stimulation electrodes is often obscured by artifacts. Prior work recorded mechanomyography (MMG) passively during closed-loop FES cycling and estimated FES-induced fatigue or predicted fatigue for FES control, without gating stimulation with stimulated-site MMG. In this study, we present VG-FES, a wearable module co-locating microphone-based MMG, programmable charge-balanced biphasic stimulation, and embedded state-gated control at one on-skin thigh site. After each action, we compare rectus femoris (RF) mean power frequency (MPF) with an early-session baseline of the same direction, giving a relative state. A threshold on its window means enables fixed-duration bursts separated by rest periods. During onboard stimulation, MMG remained recordable, whereas near-site EMG was artifact-dominated. Under prolonged external stimulation, cycle-wise MMG tracked an independent local-pressure reference (Spearman rho = 0.968). In leave-one-session-out evaluation on 2284 squat actions (11 sessions, eight participants), MMG-based action segmentation reached an event-detection F1 of 0.923 and direction classification a balanced accuracy of 0.925. Online, over 15.69 min of self-paced squats, one participant received four bursts while MMG acquisition and action monitoring continued. Mechanical feedback from the stimulated site offers wearable FES and assistive robotics a per-action basis for state-gated stimulation.

Comment
9 pages, 8 figures. Submitted to IEEE Robotics and Automation Letters

Closest papers

Nearest neighbours by meaning across the whole index.

A Mechanomyography-Based Integrated Sensing-Stimulation System for Fatigue-Aware Neuromuscular Therapy

cs.HC ·2026-10-11 ·Xiao Jin, Cong Liu, Zhenhua Yu
similarity 0.78
Abstract · 12 pages, 14 figures

Muscle fatigue limits the effectiveness of functional electrical stimulation (FES), yet fatigue monitoring during active stimulation remains challenging because electromyography (EMG) is severely contaminated by stimulation artifacts. To address this issue, this study proposes an integrated mechanomyography-based sensing framework (MMG-FES) for artifact-resistant fatigue monitoring during stimulation. Fatigue states were first characterized during voluntary movement using established EMG spectral indicators, including median frequency (MF) and mean power frequency (MPF), and then linked to MMG-derived features, including high-frequency energy ratio (HFER) and spectral bandwidth (BW), for fatigue recognition under stimulation conditions. Experimental results showed consistent fatigue-related trends, with EMG spectral features decreasing and MMG features exhibiting coordinated spectral redistribution across repeated contractions. Using these features, the proposed framework achieved fatigue-state recognition accuracies of 0.93 and 0.96 with logistic regression and random forest, respectively. These findings support MMG as a physiologically meaningful and stimulation-compatible modality for fatigue-aware closed-loop neuromuscular stimulation.

0.42

Anticipatory Textile MMG-Strain Sensing for Confirm-Then-Assist Soft Knee Exosuits

cs.RO ·2026-10-11 ·Zheng Ma, Xiao Jin, Zhenhua Yu
similarity 0.65
Abstract · 8 pages, 9 figures, 4 tables

Soft wearable robots must commit to assistance around movement onset, when the available signals are ambiguous. Surface electromyography (sEMG) detects neuromuscular drive early but degrades under sweat and electrode shift, and kinematic sensors respond only once the limb moves. This letter presents a knitted textile interface that co-samples a three-channel mechanomyography (MMG) array and an anterior strain sensor on a single synchronous 500 Hz clock. Across five participants, MMG activation preceded strain-detected knee motion during sit-to-stand by per-channel medians of 322-344 ms. Sampled on the same clock, the sign of the strain slope resolved movement direction on 649 of 650 completed transitions with no training or per-participant calibration, raising four-class balanced accuracy from 90.3% to 95.6%. The fused signals drove a two-stage confirm-then-assist policy for a soft pneumatic knee. Across 240 trials in four participants, the onboard controller entered the assist state on 78 of 80 sit-to-stand trials and on none of the 80 isometric co-contractions. It also entered the assist state on 27 of 80 stand-to-sit trials and left it at the hold timeout, motivating an antagonistic flexor gauge to resolve this direction at onset. Co-sampling muscle acoustics with textile strain on one clock lets the inflation command be issued around movement onset.

0.37

Synchronized AMG and EMG Dataset of Lower-limb Muscle Activities in Everyday Training

cs.HC ·2026-08-12 ·Dongxu Tang, Shih Ying-Lei, Zhuoyi Ren, Jianting Liao, Yitian Shao
benchmarkdataset similarity 0.58
Abstract

Understanding how lower-limb muscle groups coordinate is important for studying movement impairment, rehabilitation, and physical performance. Reproducible analysis of this coordination requires multimodal recordings that relate local muscle-related signals with body-level kinematics. Complementing neural-level electrical activation captured by EMG, AMG provides a valuable mechanical approach to monitoring muscle activity. Here, we introduce a synchronized, multimodal dataset for healthy-adult lower-limb activities. For data collection on the left leg, 16 triaxial accelerometers were evenly divided into four muscle-site clusters for AMG recording, complemented by four surface EMG channels. A 15-marker optical motion-capture (MoCap) system captured lower-body kinematics, with the resulting marker trajectories used to compute bilateral knee and ankle joint angles. Our dataset contains 1,918 trials from 30 subjects across 16 task conditions. We benchmark the dataset by estimating four joint angles from 300 ms windows of the 5-100 Hz band-pass-filtered AMG data and assess matched EMG features in a separate modality ablation. In the primary cross subject benchmark, the four reference models achieved mean absolute errors of 8.840$^\circ$-9.591$^\circ$. The benchmark and ablation results characterize performance across subjects, tasks, and joint angles and examine the effects of sensor configuration, modality, the number of training subjects, and frequency representation. The release includes documented timing definitions, processed data, and reproducible benchmark resources. https://dongxutang918-afk.github.io/SAME-Limb/

0.16

A Portable Multichannel Kilohertz Current Stimulator for Selective Peripheral Transcutaneous Stimulation

eess.SP ·2026-09-19 ·Jiatong Jiang, Andrea Bottin, Simos Koutsoftidis, Enrico Merlo, Georgios Gryparis +4 more
unusual similarity 0.56
Abstract · 12 pages, 10 figures, to be submitted to journal

We present SineStim, a portable, 12-channel current stimulator for transcutaneous spinal cord stimulation and peripheral electrical stimulation at kilohertz frequencies. Each channel delivers independent, current-controlled sinusoidal waveforms with amplitudes from 0 to 50 mA (0.1 mA resolution) and frequencies from 0 to 50 kHz (0.1 Hz resolution), with burst modulation modes supported. A custom output stage with a high compliance voltage of $\pm$ 120 V was designed and developed, with galvanically isolated channels and independently programmable stimulation parameters for each channel. The stimulator performance was tested on both passive loads and human subjects. Benchtop characterisation on resistive and resistive-capacitive loads demonstrated a total harmonic distortion between 1 - 8 % across typical operating conditions. Multichannel functionality was demonstrated in two-channel human forearm stimulation experiments. Burst-modulated waveforms with differing channel amplitudes modulated inter-finger force ratios, and channels with small frequency offsets elicited temporal interference force patterns at the beat frequency. Smoothly enveloped bursts of kilohertz sinusoidal waveforms produced negligible stimulation artifacts at steady state in concurrent surface electromyography (sEMG) recordings at motor threshold, in contrast to conventional biphasic square wave stimulation. SineStim delivers precise, isolated, multichannel kilohertz stimulation through a portable device, with performance demonstrated on both benchtop loads and human participants. By combining multichannel spatial control with minimal-artifact sEMG compatibility, SineStim enables future precision non-invasive neural stimulation paradigms based on multichannel optimisation and real-time closed-loop control capabilities not available via existing single-channel stimulators.

0.28

QA-CMIF:Accurate and Lightweight Cross-Modal Latent Imputation and Fusion for Fault-Tolerant sEMG-Inertial Hand Gesture Recognition

cs.LG ·2026-11-15 ·Xinyu Tao, Shuang Huang, Yeyun Cai, Fang Deng
similarity 0.56
Abstract

Fusing surface electromyography (sEMG) with inertial measurements is widely used for myoelectric prosthesis control and wearable human-machine interfaces. In daily wear, however, socket micro-displacement, electrode lift-off, and wire failures often corrupt an unknown subset of sEMG channels through burst artifacts, lift-off shocks, or open-circuit dropouts. Existing fusion networks mix all channels in the first convolutional layer, so a few corrupted electrodes contaminate the entire latent representation, whereas gate-only attenuation of corrupted channels discards the co-activation cues needed to separate fine-grained gestures. We propose QA-CMIF, a quality-aware cross-modal latent imputation and fusion framework that encodes each sEMG channel independently, scores its reliability with a soft gate, and protects intact channels via a confidence-weighted residual bypass, while a cross-attention imputer repairs degraded channels in latent space using the inertial stream and remaining reliable sEMG channels under a bad-channel alignment loss. Across within-subject evaluations on 29 participants from Ninapro DB3, DB2, and DB5 spanning 17-52 gesture classes, QA-CMIF outperformed the gate-only baseline under 50% channel corruption by 1.29-2.65 percentage points, denoted pp, across all three 17-class cohorts with paired-t Holm-adjusted p<0.002, widened this margin to 2.59-4.15 pp on the 40- and 52-class tasks, and surpassed corruption-augmented conventional fusion by 4.61-19.85 pp. Requiring only 0.175-0.185M parameters and 2.45-2.63M multiply-accumulate operations across the 2000 Hz and 200 Hz setups, QA-CMIF saves 46%-55% in parameters and 72%-81% in compute over recent baselines with a 1.44 ms 99th-percentile single-thread CPU latency.

0.28

Data-Centric Neuromotor Interfaces for Portable Human-Machine Interaction

cs.RO ·2026-08-31 ·Jiaxuan Li, Di Wu, Jianhua Liu, Yuxin Zhao, Jinnuo Li +5 more
publishedbenchmark similarity 0.56
Abstract

Dexterous human-machine interaction requires intuitive and expressive interfaces that can be efficiently deployed on constrained edge devices. Flexible material-based neuromotor interfaces hold considerable promise, as they decode human movement intention into natural control. Although emerging flexible electronic skins enable wearable high-fidelity data acquisition, practical deployment inevitably involves trade-offs between computational resources and portability. We present a data-centric paradigm where physiological features yield fundamental separability, providing sufficient discriminative cues for recognition. A wireless, high-bandwidth system developed for collecting various electrophysiological signals, when integrated with muscle-specific electrodes, forms a surface electromyography-based interface. Exploiting highly separable data, a 2,210-parameter model achieves 94.36% accuracy across 34 gestures and can be rapidly deployed on edge devices, establishing a new thousand-parameter benchmark for dexterous decoding. The underlying data-algorithm interactions in the data-centric paradigm are further clarified, demonstrating its feasibility in real-world scenarios. This study provides a principled and validated pathway for practical deployment of reliable neuromotor interfaces.

0.22

WAVES: Wearable Active Vibroacoustic Elasticity Sensing for Low-Cost and Non-Invasive Muscle Stiffness Monitoring

cs.ET ·2026-11-04 ·Shubham Rohal, Dong Yoon Lee, Shijia Pan
similarity 0.55
Abstract

Muscle stiffness is a physiologically meaningful biomarker associated with a wide range of musculoskeletal and neurological conditions. However, existing muscle stiffness assessment methods, such as shear wave elastography (SWE), manual palpation, and handheld mechanical probes, remain impractical for continuous, everyday monitoring due to bulky hardware, operator dependence, and limited self-use. Meanwhile, wearable muscle-sensing modalities such as Electromyography (EMG) and Mechanomyography (MMG) primarily capture muscle activation rather than passive mechanical properties of tissue at rest, leaving a critical gap in portable monitoring of resting muscle stiffness. In this work, we present WAVES, a wearable system for continuous monitoring of muscle stiffness via active vibroacoustic sensing. WAVES injects controlled vibroacoustic excitation into soft tissue and estimates muscle stiffness by measuring shear-wave propagation velocity through Time-Difference-of-Arrival (TDoA) analysis across spatially distributed wearable sensors. To achieve accurate TDoA estimation with low-cost wearable hardware, we develop a physiology- and quality-guided vibroacoustic sensing framework that effectively screens and refines TDoA for accurate stiffness estimation. We evaluate WAVES through characterization experiments using ballistic jelly and end-to-end on-body evaluation with human participants. Results demonstrate that WAVES can robustly estimate muscle stiffness across multiple users and different superficial muscles while enabling lightweight, wearable deployment for everyday use. WAVES is able to achieve a muscle stiffness estimation error of 13.1% or less across multiple users and multiple muscle groups.

0.25

EFormer: Temporally Aligned Local Correction for Continuous sEMG-Based Hand Pose Tracking

cs.LG cs.HC ·2026-09-30 ·JiaCheng Ge, SiYu Zhang
similarity 0.55
Abstract

Surface electromyography (sEMG) provides a wearable, camera-free signal for continuous hand-motion inference. Mapping muscle activity to joint kinematics remains challenging because the recorded waveforms are indirect measurements, their relationship with motion changes over time, and individual anatomy and sensor placement alter the signal distribution. This paper presents EFormer, a residual feature-correction network built on a frozen tracking backbone. EFormer combines a high-rate event branch, temporally aligned local cross-attention, two causal rotary position embedding (RoPE) temporal layers, and a bounded, dynamically gated residual. EFormer receives 16-channel sEMG sampled at 2 kHz and fuses a 64-channel tracking representation at 25 Hz with a 128-channel event representation at 200 Hz. Cross-attention uses a nominal delay of 100 ms, a 300 ms history parameter, and a 50 ms tolerance; its causal mask restricts each query to events occurring 50-400 ms earlier. The correction scale is 0.15. The evaluated continuation-training configuration contains 585,376 trainable parameters and 5,974,508 frozen parameters. On the test set, EFormer achieves an MAE of 0.1546634 rad, an RMSE of 0.24063 rad, and an R^2 of 0.74801, compared with 0.1745326 rad, 0.2715448 rad, and 0.6791103 for the official tracking baseline. EFormer reduces MAE by 11.38% relative to the baseline. The results show that temporally aligned event-feature correction can reduce continuous hand-pose tracking error.

0.15