CS Paper Radar

Data-Centric Neuromotor Interfaces for Portable Human-Machine Interaction

Jiaxuan Li, Di Wu, Jianhua Liu, Yuxin Zhao, Jinnuo Li, Xiao Zhang, Zhenzhi Ying, Changsheng Dai, Xiang Li, Liming Shu

cs.RO ·submitted 2026-08-31 06:17 UTC · v1
publishedbenchmark

Abstract

Dexterous human-machine interaction requires intuitive and expressive interfaces that can be efficiently deployed on constrained edge devices. Flexible material-based neuromotor interfaces hold considerable promise, as they decode human movement intention into natural control. Although emerging flexible electronic skins enable wearable high-fidelity data acquisition, practical deployment inevitably involves trade-offs between computational resources and portability. We present a data-centric paradigm where physiological features yield fundamental separability, providing sufficient discriminative cues for recognition. A wireless, high-bandwidth system developed for collecting various electrophysiological signals, when integrated with muscle-specific electrodes, forms a surface electromyography-based interface. Exploiting highly separable data, a 2,210-parameter model achieves 94.36% accuracy across 34 gestures and can be rapidly deployed on edge devices, establishing a new thousand-parameter benchmark for dexterous decoding. The underlying data-algorithm interactions in the data-centric paradigm are further clarified, demonstrating its feasibility in real-world scenarios. This study provides a principled and validated pathway for practical deployment of reliable neuromotor interfaces.

Closest papers

Nearest neighbours by meaning across the whole index.

Wearable Multimodal Human-Machine Interface for Integrated Hand Intentions Decoding in Dynamic Teleoperation

cs.RO ·2026-09-07 ·Jiaxuan Li, Yinshi Wu, Xiao Zhang, Hongyu Wang, Renzhen Le +2 more
similarity 0.67
Abstract

Under ubiquitous teleoperation environments with optically challenging conditions, an interface for tele-operated grasping that combines wearability with precise decoding of hand intentions (hand pose, gestures, and grasping force) is essential. Yet, existing interfaces often fall short in meeting these demands, compromising either the diversity of multiple intentions decoding or wearability. To address this, we developed a novel Multiple Intentions Decoding Human-Machine Interface (MI-DHMI) that integrates high-throughput surface electromyography (sEMG) sensors with hand-mounted and forearm-mounted inertial measurement units (IMUs). The developed interface is supported by a unified framework for simultaneous multiple intentions decoding. By employing multimodal deep learning and hardware design with a low noise floor, the decoding framework selectively focuses on the sEMG components that are genuinely associated with finger movements. This effectively reduces decoding errors caused by sEMG variability during unconstrained upper-limb motions, thereby significantly enhancing robustness. Even under unconstrained wrist and forearm motion, the interface achieves a gesture recognition accuracy exceeding 97%, grasping force estimation with $R^2 = 0.95$, and hand pose decoding consistent with the actual hand pose, outperforming baseline devices and algorithms. Ablation studies further validate the effectiveness of the proposed decoding framework. Finally, two online experiments were conducted to validate the device, demonstrating its superior performance in high-stability tasks, including a pouring task and object grasping. The developed interface provides a new solution of a fully wearable, multiple intentions decoding system, offering effective support for ubiquitous teleoperation and contributing to the advancement of human-machine interaction research.

0.27

Soft Active Electromyography Interface for Machine Learning-Enabled Silent Speech Recognition

cs.LG cs.HCcs.SD ·2026-08-27 ·Yuta Kurotaki, Shusuke Yamakoshi, Reitaro Yoshida, Yutaka Isoda, Tamami Takano +4 more
publishedunusual similarity 0.64
Abstract · 17 pages, 5 figures, supplementary information

Silent speech recognition (SSR) provides an alternative communication pathway in the absence of audible speech. However, conventional approaches are limited by the need for constant facial attachment, privacy concerns, and unstable signal acquisition. Here, we propose a soft, active electromyography (EMG) interface that enables word-level SSR using machine learning. Worn on the hand, the device uses a fingertip electrode that can be positioned near the lips to acquire EMG signals only when needed. The interface integrates liquid metal (LM) interconnects, transparent flexible printed circuit (FPC) electrodes, and elastomer encapsulation to ensure high mechanical stability during finger motion. A deep neural network trained on these stable signals achieved a mean accuracy of 97.2 $\pm$ 1.3% across three subjects in classifying a 30-word vocabulary, demonstrating robust linguistic discrimination. Furthermore, real-time drone control validates the practicality of this approach in noisy and privacy-sensitive environments where conventional voice recognition fails. This study highlights the potential of soft, wearable EMG systems as secure and intuitive human-machine interfaces.

0.38

LiteEMG-FM: An Efficient and Deployable Foundation Model for Robust EMG Sensing

cs.LG ·2026-10-01 ·Tianhao Wu, Xu Wu, Amirmohammad Radmehr, Jiawei Yu, Yi Wu +2 more
similarity 0.64
Abstract · The authors are withdrawing this manuscript because the current experimental evaluation and validation are insufficient to adequately suppor…

Electromyography (EMG) signals vary substantially across individuals, body regions, recording sessions, and sensing hardware, limiting the generalization of models for assistive devices and human-computer interaction. Existing time-series foundation models are also computationally expensive for real-time wearable deployment and often fail to capture EMG-specific time-frequency characteristics. We present LiteEMG-FM, an efficient hybrid CNN-Transformer foundation model for practical EMG sensing. Pretrained on 16 diverse upper- and lower-limb EMG datasets, LiteEMG-FM learns representations that generalize across users and datasets. For resource-constrained deployment, we implement a hierarchical wake-up architecture in which a lightweight, always-on 1D-CNN filters rest and non-target activity and activates LiteEMG-FM only for valid gestures. We evaluate full inference offloading, split inference, and full on-device processing, characterizing their trade-offs in latency, power consumption, and memory footprint. Across diverse evaluation settings, LiteEMG-FM outperforms state-of-the-art time-series foundation models and supervised baselines, particularly under zero-calibration cross-participant and data-scarce conditions. These results demonstrate that LiteEMG-FM is an effective, efficient, and deployable foundation model for EMG applications.

0.11

DoF-Query Transformer for Adaptive Fusion of Egocentric Vision and Forearm HD-sEMG in Continuous Hand Kinematics

cs.CV cs.HCcs.LG ·2026-11-15 ·Jiahang Liu, Wenbo Zhang, Junsong Wang, Zhenzhi Ying, Siqi Hou +2 more
similarity 0.63
Abstract

Continuous and accurate estimation of human hand kinematics is important not only for intuitive human-machine interaction, but also for capturing fine-grained human manipulation demonstrations that can provide action supervision for embodied-intelligence datasets and dexterous robot learning. However, individual sensing modalities may be insufficient for reliable estimation under varying operating conditions. We present a finger-unencumbered multimodal framework for continuous regression of 20 hand joint angles from egocentric RGB images and 128-channel forearm high-density surface electromyography (HD-sEMG). The framework combines a Vision Transformer-based visual encoder, a Transformer-based EMG encoder, and a degree of freedom (DoF) query Transformer fusion decoder. To account for the varying informativeness of visual and EMG cues across joint DoFs and input conditions, the decoder assigns a separate learnable query to each DoF, enabling DoF-specific and context-adaptive fusion of the two modalities. The framework was evaluated on synchronized multimodal data from 10 participants. Averaged across participants, the proposed fusion model achieved a mean coefficient of determination ($R^2$) of $0.88$ and a mean absolute error (MAE) of $2.80^\circ$, compared with $0.82$ and $3.21^\circ$ for the vision-only model and $0.68$ and $5.13^\circ$ for the EMG-only model. It also outperformed the evaluated representative unimodal baselines and alternative fusion designs. DoF-wise analyses showed larger fusion gains for visually ambiguous joints and viewing conditions, while synthetic visual occlusion demonstrated greater robustness than vision-only estimation. These results highlight the complementary value of egocentric vision and forearm HD-sEMG for capturing fine-grained human hand kinematics, with potential applications in human demonstration acquisition and dexterous robot learning.

0.05

MyoFlow: Anchor-Tied Rectified Flow for HD-sEMG Gesture Recognition Across Sessions and Subjects

cs.LG ·2026-09-15 ·Chenhao Wu, Dingjie Peng, Zhihe Zhang, Satoshi Funabashi, Satoshi Konishi +4 more
hot direction similarity 0.63
Abstract

High-density surface electromyography (HD-sEMG) gesture recognition supports prosthetic control, assistive robotics, and rehabilitation, but electrode re-donning and physiological variability cause distribution shifts that degrade accuracy across sessions and subjects. Generative HD-sEMG models primarily synthesize signals for augmentation; although diffusion models enhance representation learning, prediction still relies on a separate classifier. To tie learned dynamics to the decision rule, we propose MyoFlow, the first discriminative flow-matching framework for HD-sEMG recognition across sessions and subjects. It recasts classification as anchor-tied transport: a domain-conditioned rectified flow moves encoded windows toward gesture anchors that serve as transport targets and define the nearest-anchor decision geometry, enabling zero-shot recognition without an independent head. On the Hyser dataset, MyoFlow improves mean cross-session and cross-subject accuracy over the strongest diffusion-based baseline by 4.24% and 6.37%, respectively, and achieves 91.71% mean zero-shot accuracy and 97.39% mean few-shot accuracy across multiple days on the CEMHSEY dataset.

0.32

EMGBlend: Heterogeneity-Aware Self-Supervised Pretraining for Gesture and Force Decoding

cs.LG cs.AI ·2026-09-22 ·Yuwei Jia, Cheng Zhong, Jinyang Yu, Zhe Cui
code/data similarity 0.62
Abstract

Public surface electromyography (EMG) datasets vary widely in electrode layout, channel count, frequency support, and size. Simply mixing them for pretraining can misalign channel semantics, introduce spectral targets that some devices cannot observe, and let large or high-channel-count datasets dominate learning. We introduce EMGBlend, a self-supervised framework designed around these differences. It combines shared channel patches with geometry-aware attention, restricts spectral targets to each recording's supported frequency band, and balances exposure across data sources. We pretrain a 109M-parameter model on 11 public EMG sources and evaluate it on gesture recognition, continuous-force regression, and contact classification. EMGBlend consistently outperforms matched random initialization and waveform reconstruction controls. Fixed-budget source controls show that multi-source pretraining improves gesture recognition and remains competitive for force decoding. Ablations confirm that geometry, band-aware targets, and source balancing each contribute to transfer, although cross-person NinaPro force estimation remains difficult. Overall, EMGBlend shows how heterogeneous EMG datasets can be combined through explicit mechanism design rather than simple concatenation. Code is available at https://github.com/tamanano/EMGBlend

0.25

High Fidelity Capture, Reconstruction, and Transfer of Human Demonstrations for Robot-Assisted Bathing

cs.RO cs.GR ·2026-08-10 ·Arjun S. Lakshmipathy, Jonathan P. King, Ethan Zuo, Rohit Satishkumar, Hongyi Chen +4 more
published similarity 0.62
Abstract · Accepted to Robotics: Science and Systems (RSS) 2026. Official conference page: https://www.roboticsproceedings.org/rss22/p094.pdf

Despite the demand for robots in high-value clinical tasks like bathing, contemporary systems still lack the safety and reliability required for complex, sustained physical interaction with humans. A key challenge hindering the development of such systems is that collecting, understanding, and effectively transferring highly dynamic, contact-rich human bathing demonstrations is difficult, even with modern motion and tactile sensing equipment. We present a straightforward, but effective framework for doing so with high fidelity by utilizing contact regions as a key processing primitive. We use our framework to build a dataset of bathing demonstrations performed by trained clinicians on human subjects. We then use this dataset to design and control an arm-mounted dexterous soft hand to perform bathing tasks on a mannequin using open- and closed-loop strategies. Our dataset is the first to provide high quality synchronized motion, shape, contact, and force during sustained, contact-rich human-human interaction, and our transfer strategies demonstrate effective use of these data across multiple levels of the robotics stack. All relevant materials will be publicly released to enable further advancements in physical human-robot interaction (pHRI) research.

0.38

OHRID-Retail: An Open Multimodal Dataset of Human Activity in Retail Environments

cs.RO cs.HC ·2026-09-16 ·Xiangrui Wang, Yuetong Wu, Jalen Beeman, Robert Cook, Yu Gu +4 more
similarity 0.61
Abstract

Open datasets describing human behavior in environments shared with mobile robots remain limited, particularly for retail activities that combine locomotion, reaching, object handling, and robot guided movement. This paper introduces OHRID Retail, an open, human centered multimodal dataset collected from 16 healthy adults performing a simulated shelf picking task under three within participant conditions: no robot, low speed robot guidance, and high speed robot guidance. Each participant completed two trials per condition. Whole body kinematics were recorded using 17 Xsens Awinda inertial sensors and muscle activity was measured at 10 locations using Delsys Trigno surface electromyography sensors. Descriptive analyses demonstrate variation in whole body movement intensity and muscle activation across robot interaction conditions and body locations. OHRID Retail provides openly available raw recordings, processed measures, documentation, and reproducible analysis resources. The dataset can support research in human activity recognition, multimodal sensor fusion, occupational biomechanics, ergonomics, human aware robot navigation, and human robot interaction in retail and related shared environments.

0.17