MyoFlow: Anchor-Tied Rectified Flow for HD-sEMG Gesture Recognition Across Sessions and Subjects

Chenhao Wu, Dingjie Peng, Zhihe Zhang, Satoshi Funabashi, Satoshi Konishi, Wuqiang Yang, Hiroshi Onoda, Hironori Washizaki, Jiang Liu

cs.LG ·submitted 2026-09-15 13:51 UTC · v2
hot direction

Abstract

High-density surface electromyography (HD-sEMG) gesture recognition supports prosthetic control, assistive robotics, and rehabilitation, but electrode re-donning and physiological variability cause distribution shifts that degrade accuracy across sessions and subjects. Generative HD-sEMG models primarily synthesize signals for augmentation; although diffusion models enhance representation learning, prediction still relies on a separate classifier. To tie learned dynamics to the decision rule, we propose MyoFlow, the first discriminative flow-matching framework for HD-sEMG recognition across sessions and subjects. It recasts classification as anchor-tied transport: a domain-conditioned rectified flow moves encoded windows toward gesture anchors that serve as transport targets and define the nearest-anchor decision geometry, enabling zero-shot recognition without an independent head. On the Hyser dataset, MyoFlow improves mean cross-session and cross-subject accuracy over the strongest diffusion-based baseline by 4.24% and 6.37%, respectively, and achieves 91.71% mean zero-shot accuracy and 97.39% mean few-shot accuracy across multiple days on the CEMHSEY dataset.

Closest papers

Nearest neighbours by meaning across the whole index.

WearableBridge: Task-Guided Latent Transport for Free-Living Activity Recognition

cs.LG ·2026-11-06 ·Jingjing Zou, Yixin Wang
code/data similarity 0.65
Abstract · 26 pages, 5 figures, 11 tables. Code and interactive demo: https://github.com/jingjingz/WearableBridge

Wrist-worn accelerometers make activity monitoring feasible at scale, but incidental arm motion, device orientation, and shifting context blur the signal that separates activities. Calibration studies supply higher-quality references such as concurrent thigh recordings or supervised laboratory wrist sessions, but they are expensive, cover few participants, and are rarely available at deployment. How can limited reference data improve recognition for participants who wear only a wrist device? We propose WearableBridge, which holds the reference encoder and classifier fixed and learns a task-guided transport map, the bridge, that carries each wrist feature into the region the classifier associates with its activity. Reference features or the classifier's predictions indicate the destination, and a classification loss penalizes wrist features that land in the region of another activity. We instantiate WearableBridge with three bridges: Mapper regresses onto reference features, Distillation matches the classifier's class probabilities, and MeanFlow learns a one-step flow from wrist toward reference features. On 40 held-out free-living PAAWS participants, all three bridges improve macro-F1 in every training run, and the strongest, MeanFlow, raises mean macro-F1 from 35.1% to 56.0% with concurrent thigh references (Thigh2Wrist), and from 54.0% to 63.5% with group-matched laboratory wrist references (Lab2Freeliving). Fitted only on PAAWS, MeanFlow also raises macro-F1 on the CAPTURE-24 cohort from 42.8% to 54.7%. The gains replicate on selfBACK, hold across four reference encoders, and grow with temporal context. A study can therefore collect reference recordings for a calibration subset and improve wrist-only recognition for every other participant, training only a bridge of 0.13 to 2.44 million parameters while the reference encoder and classifier stay unchanged.

0.29

Cross-User Adaptation for sEMG Gesture Recognition via Continual Learning

cs.LG eess.SP ·2026-10-25 ·Aran Ramakrishnan, Shubhi Mishra, Tyler Ham, Assel Kembay, Jason Eshraghian
published similarity 0.65
Abstract · 4 pages, 2 figures, 3 tables. Accepted at IEEE BioCAS 2026

Prosthetic and assistive interfaces increasingly depend on decoding hand gestures from surface electromyography (sEMG). Because the signal is shaped by person-specific factors, the recurrent neural networks (RNNs) commonly used to model these temporal streams must adapt to new wearers and new gesture classes after deployment. Continual learning (CL) enables this adaptation without retraining from scratch, yet applying it to recurrent sEMG models is not straightforward. Standard recurrent training practices can destabilize learning, and which CL strategy holds up under realistic cross-user drift is unestablished. We evaluate three representative CL strategies under domain- and class-incremental drift on NinaPro DB1, and find experience replay to outperform elastic weight consolidation (EWC) and naive fine-tuning. It reaches 83.3% final accuracy for class-incremental drift while limiting forgetting to 1.8-5.8% accuracy drop, as against 16.2-28.5% for EWC and naive training. We further show these models must be trained on shuffled, independently-windowed segments. Streaming windows in temporal order collapses the network into predicting a single dominant gesture, while a shuffled, stateless regime trains stably. Finally, hand-crafted time-domain features raise per-task accuracy by up to about 40% over raw signals, but only replay preserves that gain under class-incremental drift.

0.29

Deep Neural Networks for Learning Intent from sEMG Signals to Support Hardware Devices for Post-Stroke Neurorehabilitation

cs.LG ·2026-09-09 ·Zakariyya Brewster, Divy Wadhwani, Emily Yan, Aidan Wang, Karma Namgyal +3 more
hot direction similarity 0.64
Abstract

Finger-specific motor intent is a clinically meaningful control signal for post-stroke neurorehabilitation, where residual muscle activity may remain measurable despite weak or incomplete movement. We study five-finger multilabel intent decoding from impaired-arm high-density surface electromyography (sEMG) in PhysioMio, a bilateral longitudinal dataset collected from stroke patients. A common processing protocol aligns movement labels, applies 20--450 Hz Butterworth filtering and Symlet-4 wavelet denoising, segments overlapping 200 ms windows, and extracts twelve time- and frequency-domain descriptors per channel. Direct LSTM, CNN, and GNN baselines reveal complementary behavior: the LSTM attains the highest subset accuracy (0.545), whereas the GNN attains the highest macro F1 (0.706) and macro AUPRC (0.776). Architecture search then identifies CNN-Large as the strongest single-split CNN, with 0.593 subset accuracy and 0.714 macro F1, while CNN-Micro provides a compact architecture for embedded inference. To match a four-sensor hardware design, we retrain CNN-Micro using channels associated with ECRB, ECRL, FDS, and FDP and exclude the ground electrode from model input. Across five seeds, cross-channel knowledge distillation improves the four-channel student over direct training, reaching $0.5219 \pm 0.0114$ subset accuracy, $0.7612 \pm 0.0038$ finger accuracy, and $0.6095 \pm 0.0058$ macro F1. The selected 123K-parameter model accepts nine windows of 48 features and has been exported to ONNX. These results establish a reproducible software path from post-stroke sEMG to compact five-finger intent prediction for subsequent hardware-in-the-loop evaluation.

0.26

Data-Centric Neuromotor Interfaces for Portable Human-Machine Interaction

cs.RO ·2026-08-31 ·Jiaxuan Li, Di Wu, Jianhua Liu, Yuxin Zhao, Jinnuo Li +5 more
publishedbenchmark similarity 0.63
Abstract

Dexterous human-machine interaction requires intuitive and expressive interfaces that can be efficiently deployed on constrained edge devices. Flexible material-based neuromotor interfaces hold considerable promise, as they decode human movement intention into natural control. Although emerging flexible electronic skins enable wearable high-fidelity data acquisition, practical deployment inevitably involves trade-offs between computational resources and portability. We present a data-centric paradigm where physiological features yield fundamental separability, providing sufficient discriminative cues for recognition. A wireless, high-bandwidth system developed for collecting various electrophysiological signals, when integrated with muscle-specific electrodes, forms a surface electromyography-based interface. Exploiting highly separable data, a 2,210-parameter model achieves 94.36% accuracy across 34 gestures and can be rapidly deployed on edge devices, establishing a new thousand-parameter benchmark for dexterous decoding. The underlying data-algorithm interactions in the data-centric paradigm are further clarified, demonstrating its feasibility in real-world scenarios. This study provides a principled and validated pathway for practical deployment of reliable neuromotor interfaces.

0.22

EMGBlend: Heterogeneity-Aware Self-Supervised Pretraining for Gesture and Force Decoding

cs.LG cs.AI ·2026-09-22 ·Yuwei Jia, Cheng Zhong, Jinyang Yu, Zhe Cui
code/data similarity 0.63
Abstract

Public surface electromyography (EMG) datasets vary widely in electrode layout, channel count, frequency support, and size. Simply mixing them for pretraining can misalign channel semantics, introduce spectral targets that some devices cannot observe, and let large or high-channel-count datasets dominate learning. We introduce EMGBlend, a self-supervised framework designed around these differences. It combines shared channel patches with geometry-aware attention, restricts spectral targets to each recording's supported frequency band, and balances exposure across data sources. We pretrain a 109M-parameter model on 11 public EMG sources and evaluate it on gesture recognition, continuous-force regression, and contact classification. EMGBlend consistently outperforms matched random initialization and waveform reconstruction controls. Fixed-budget source controls show that multi-source pretraining improves gesture recognition and remains competitive for force decoding. Ablations confirm that geometry, band-aware targets, and source balancing each contribute to transfer, although cross-person NinaPro force estimation remains difficult. Overall, EMGBlend shows how heterogeneous EMG datasets can be combined through explicit mechanism design rather than simple concatenation. Code is available at https://github.com/tamanano/EMGBlend

0.25

MotorSense: A Video-EMG Dataset of Motoric Representations for Action Understanding

cs.CV cs.RO ·2026-10-30 ·Eadom Dessalene, Michael Maynord, Amir-Hossein Shahidzadeh, Botao He, Yasamin Tabatabaee +4 more
publishedcode/data similarity 0.63
Abstract · NeurIPS 2026. 27 pages, 9 figures, 5 tables. Project page: https://www.cs.umd.edu/~edessale/motorsense/

Computer vision models learn hand action only from its visual consequences, without access to the underlying embodied motor signals. We address this absence with MotorSense, the first large-scale paired egocentric video and surface electromyography (EMG) dataset. MotorSense pairs bimanual EMG bands with egocentric video and yields synchronized video, bimanual EMG and IMU, and audio across 100 hours of unscripted manipulation. EMG offers a powerful scalable alternative to manual annotation: it captures finger movement, hand configuration, and the forces exerted between hand and environment as a dense signal free of occlusion and labeler bias, whereas manual annotation is costly, subjective, and unreliable under occlusion. We use MotorSense to learn sensorimotor alignment, producing an organization of action that is shared across the visual and motoric spaces, through cross-modal pre-training between video and EMG. The resultant vision models are then transferred to downstream tasks that benefit from sensorimotor alignment: in this case, action recognition, 3D hand reconstruction, and 3D contact reconstruction. We further demonstrate a generative application in which EMG motor signals are used to condition a video diffusion model, yielding videos of fine-grained hand manipulation. Across four action-centric computer vision tasks and eight popular video datasets, we demonstrate that sensorimotor alignment provides a stronger foundation for visual representation learning than conventional self-supervised learning methods over video, outperforming every baseline across all tasks and datasets evaluated.

0.28

DoF-Query Transformer for Adaptive Fusion of Egocentric Vision and Forearm HD-sEMG in Continuous Hand Kinematics

cs.CV cs.HCcs.LG ·2026-11-15 ·Jiahang Liu, Wenbo Zhang, Junsong Wang, Zhenzhi Ying, Siqi Hou +2 more
similarity 0.63
Abstract

Continuous and accurate estimation of human hand kinematics is important not only for intuitive human-machine interaction, but also for capturing fine-grained human manipulation demonstrations that can provide action supervision for embodied-intelligence datasets and dexterous robot learning. However, individual sensing modalities may be insufficient for reliable estimation under varying operating conditions. We present a finger-unencumbered multimodal framework for continuous regression of 20 hand joint angles from egocentric RGB images and 128-channel forearm high-density surface electromyography (HD-sEMG). The framework combines a Vision Transformer-based visual encoder, a Transformer-based EMG encoder, and a degree of freedom (DoF) query Transformer fusion decoder. To account for the varying informativeness of visual and EMG cues across joint DoFs and input conditions, the decoder assigns a separate learnable query to each DoF, enabling DoF-specific and context-adaptive fusion of the two modalities. The framework was evaluated on synchronized multimodal data from 10 participants. Averaged across participants, the proposed fusion model achieved a mean coefficient of determination ($R^2$) of $0.88$ and a mean absolute error (MAE) of $2.80^\circ$, compared with $0.82$ and $3.21^\circ$ for the vision-only model and $0.68$ and $5.13^\circ$ for the EMG-only model. It also outperformed the evaluated representative unimodal baselines and alternative fusion designs. DoF-wise analyses showed larger fusion gains for visually ambiguous joints and viewing conditions, while synthetic visual occlusion demonstrated greater robustness than vision-only estimation. These results highlight the complementary value of egocentric vision and forearm HD-sEMG for capturing fine-grained human hand kinematics, with potential applications in human demonstration acquisition and dexterous robot learning.

0.05

BiView-Touch: Learning Bimanual Tactile Representations by Cross-Hand Completion

cs.CV cs.RO ·2026-09-20 ·Chenxin Liang, Youchen Lai, Chuqiao Lyu, Tianxing Chen, Shoujie Li +1 more
code/datahot direction similarity 0.61
Abstract · Submitted to ICRA 2027; 9 pages, 7 figures

Bimanual interaction produces complementary tactile views of the same physical process, yet existing tactile representation learning largely models the two hands independently or combines them only for downstream prediction, leaving their cross-hand relationship unexplored. To exploit this overlooked structure, we introduce BiView-Touch, a tactile-only framework that completes masked target-hand latents from the remaining visible target-hand regions and the synchronized full contralateral hand. A student encoder with a geometry-conditioned directional decoder predicts full-view EMA latent targets, while temporal and layout counterfactuals encourage sensitivity to synchronized and anatomically organized source information. Controlled ablations and source-context interventions show that BiView-Touch learns structured cross-hand dependence on temporally aligned and anatomically organized contralateral tactile context, rather than benefiting from bilateral input alone. On the public HumanTouch dataset, its frozen representations consistently outperform representative self-supervised baselines across low-label settings. With only 5\% downstream labels, BiView-Touch achieves relative balanced-accuracy gains of 7.1\% on bilateral wrist-motion recognition and 14.1\% on force-derived interaction-phase recognition. We further introduce BVT-20, a 20-task bilateral tactile dataset, and demonstrate transfer across recording sessions and pretraining corpora, including transfer to a held-out bimanual task. Our code and dataset details are available on the anonymous project page: https://anonymous.4open.science/w/biview-touch-review-site-050C/.

0.60