CS Paper Radar

WearableBridge: Task-Guided Latent Transport for Free-Living Activity Recognition

Jingjing Zou, Yixin Wang

cs.LG ·submitted 2026-11-06 06:51 UTC · v1
code/data

Abstract

Wrist-worn accelerometers make activity monitoring feasible at scale, but incidental arm motion, device orientation, and shifting context blur the signal that separates activities. Calibration studies supply higher-quality references such as concurrent thigh recordings or supervised laboratory wrist sessions, but they are expensive, cover few participants, and are rarely available at deployment. How can limited reference data improve recognition for participants who wear only a wrist device? We propose WearableBridge, which holds the reference encoder and classifier fixed and learns a task-guided transport map, the bridge, that carries each wrist feature into the region the classifier associates with its activity. Reference features or the classifier's predictions indicate the destination, and a classification loss penalizes wrist features that land in the region of another activity. We instantiate WearableBridge with three bridges: Mapper regresses onto reference features, Distillation matches the classifier's class probabilities, and MeanFlow learns a one-step flow from wrist toward reference features. On 40 held-out free-living PAAWS participants, all three bridges improve macro-F1 in every training run, and the strongest, MeanFlow, raises mean macro-F1 from 35.1% to 56.0% with concurrent thigh references (Thigh2Wrist), and from 54.0% to 63.5% with group-matched laboratory wrist references (Lab2Freeliving). Fitted only on PAAWS, MeanFlow also raises macro-F1 on the CAPTURE-24 cohort from 42.8% to 54.7%. The gains replicate on selfBACK, hold across four reference encoders, and grow with temporal context. A study can therefore collect reference recordings for a calibration subset and improve wrist-only recognition for every other participant, training only a bridge of 0.13 to 2.44 million parameters while the reference encoder and classifier stay unchanged.

Comment
26 pages, 5 figures, 11 tables. Code and interactive demo: https://github.com/jingjingz/WearableBridge

Closest papers

Nearest neighbours by meaning across the whole index.

TransfHAR: Self-Supervised Wrist Representations for On-Demand Activity Recognition

cs.LG ·2026-08-16 ·Aidan Bradshaw, Riku Arakawa, Xin Liu, Karan Ahuja
top venue similarity 0.78
Abstract · Accepted to the ACM Symposium on User Interface Software and Technology (UIST '26)

Fine-grained wrist activity recognition can support applications such as procedural step guidance and context-aware assistance, yet acquiring labeled data for every new task, user, and activity granularity remains a bottleneck. We present TransfHAR, a self-supervised wrist IMU framework for on-demand, fine-grained activity recognition by learning transferable motion priors from global, unlabeled activities. We show that self-supervised pretraining on coarse wrist IMU activities (e.g., sitting, walking, exercise) learns motion structure rich enough to transfer to fine-grained manipulative, gestural, and procedural activities (e.g., snapping, stirring, waving) that are absent from pretraining. We implement TransfHAR as a real-time smartwatch application that lets users define and expand their own activity set for personalized recognition from only a few demonstrations. Across three offline cross-dataset evaluations, TransfHAR matches or exceeds fully supervised baselines that use complete label sets with equal or additional sensor channels, by 6.2 balanced-accuracy points on average. In an in-lab study with 10 participants each performing seven novel wrist activities, TransfHAR reaches 86.7% balanced accuracy across participants with five examples per class and 90.4% when updated from a single one-minute recording per class. These results indicate that broad self-supervised wrist pretraining provides an effective foundation for on-demand fine-grained activity recognition.

0.64

IMU-Bench: Benchmarking Wrist IMU Representations Across Kinematic, Semantic and Clinical Tasks

cs.RO cs.AI ·2026-10-14 ·Yiquan Li, Aidan Bradshaw, Chenfeng Gao, Karan Ahuja
benchmarkcode/data similarity 0.71
Abstract

Wrist-worn inertial measurement units (IMUs) provide a common sensing modality for tasks ranging from activity and gesture recognition to pose estimation, inertial odometry and clinical motor assessment. Existing wearable benchmarks evaluate performance across multiple tasks, but leave open how supervision for one task affects transfer to others and whether these tasks benefit from a shared representation. We present IMU-Bench, a benchmark of ten tasks from eight datasets for studying IMU multi-task performance and cross-task transfer. We compare six self-supervised methods pretrained on unlabeled recorded and simulated wrist motion, evaluating classification, pose and velocity estimation, and IMU-language retrieval. We find that our masked autoencoder, InrtlWrist, achieves the best or joint-best frozen-probe performance on nine of ten tasks, and fine-tuning improves on training from scratch on nine of ten tasks, including full-body pose, odometry and retrieval. Across transfer and joint-training experiments, supervision that benefits one target can reduce performance on others, with supervised sources transferring within kinematic estimation while, under frozen probing, none approaches the pretrained encoder on language retrieval, and joint-training gains that come at a cost to the paired task. These findings distinguish broad downstream usefulness from complementary task supervision. Code, task cards and a leaderboard are publicly available.

0.17

Characterizing the Performance Gap in Human Activity Recognition for Older Adults

cs.HC cs.LG ·2026-10-02 ·Hossein Khayami, Sungjin Hwang, Eshed Ohn-Bar, David E. Conroy, Amanda Lazar +2 more
publishedbenchmark similarity 0.67
Abstract · 8 pages, 6 figures, to be published in Proceedings of the 2026 ACM International Symposium on Wearable Computers (ISWC '26)

Human activity recognition (HAR) from wrist-worn accelerometers is increasingly used for health and behavioral tracking. Yet, most wearable HAR models are developed and evaluated on datasets dominated by younger adults, leaving it unclear whether benchmark progress generalizes across age groups. In this work, we leverage MyMove, our carefully annotated, free-living older-adult HAR dataset (mean age 71), to evaluate deep-learning architectures and training regimes under both leave-one-subject-out and cross-dataset transfer. We find that improvements on younger-adult benchmarks fail to transfer equally to data collected from older adults, resulting in a persistent and often widening performance gap. However, richer representations, particularly frozen self-supervised features pretrained on the age-diverse UK Biobank dataset, substantially improve performance on data from older adults and consistently narrow the performance gap, at modest cost to younger-adult performance, though disparities remain. These findings suggest that benchmark gains and architectural scaling alone provide an incomplete picture of progress in wearable HAR, and broader advances may require representations that better capture population diversity, alongside personalized adaptation to individual movement patterns and routines.

0.21

CoWear: Towards Collaborative Wearable Inertial Localization with Multiple Smart Devices

cs.RO ·2026-10-14 ·Zhuoyuan She, Zhanpeng Zhang, Yapeng Chen, Jiale Wang, Xin Xie +1 more
dataset similarity 0.66
Abstract · 8 pages, 5 figures

Consumer smart devices observe the same human motion from different body locations, yet existing inertial-localization benchmarks rarely provide synchronized heterogeneous wearables with device-specific motion ground truth. We present CoWear, a dataset and reference framework for collaborative inertial localization using a smartphone, smartwatch, and smart glasses. The dataset contains over 30 participants, over 300 walking sessions, and more than 30 hours and 100 km of aggregate device trajectories, with each device individually tracked by motion capture. To enable collaboration across distinct body motions, we train role-specific estimators to predict the displacement of a common reference device over synchronized temporal windows. Their predictions are transformed to the world frame using gyroscope integration and fused according to learned uncertainty. Experiments using phone, glasses, and watch as reference targets show that multi-device fusion consistently improves both displacement and trajectory rollout accuracy over individual-device estimation. CoWear provides a dataset and reproducible baseline for studying collaborative inertial localization across heterogeneous consumer wearables.

0.26

MyoFlow: Anchor-Tied Rectified Flow for HD-sEMG Gesture Recognition Across Sessions and Subjects

cs.LG ·2026-09-15 ·Chenhao Wu, Dingjie Peng, Zhihe Zhang, Satoshi Funabashi, Satoshi Konishi +4 more
hot direction similarity 0.65
Abstract

High-density surface electromyography (HD-sEMG) gesture recognition supports prosthetic control, assistive robotics, and rehabilitation, but electrode re-donning and physiological variability cause distribution shifts that degrade accuracy across sessions and subjects. Generative HD-sEMG models primarily synthesize signals for augmentation; although diffusion models enhance representation learning, prediction still relies on a separate classifier. To tie learned dynamics to the decision rule, we propose MyoFlow, the first discriminative flow-matching framework for HD-sEMG recognition across sessions and subjects. It recasts classification as anchor-tied transport: a domain-conditioned rectified flow moves encoded windows toward gesture anchors that serve as transport targets and define the nearest-anchor decision geometry, enabling zero-shot recognition without an independent head. On the Hyser dataset, MyoFlow improves mean cross-session and cross-subject accuracy over the strongest diffusion-based baseline by 4.24% and 6.37%, respectively, and achieves 91.71% mean zero-shot accuracy and 97.39% mean few-shot accuracy across multiple days on the CEMHSEY dataset.

0.32

REFIT: Recognize, Fix, and Test Wearable Sensor Placement Shifts without Labels

cs.LG cs.HC ·2026-10-06 ·Bangxun Tang
similarity 0.64
Abstract · 25 pages, 5 figures, 14 tables. Under review

We present REFIT, an input calibration for frozen activity-recognition models whose inertial sensors are worn differently at deployment than in training. When users move a watch to the other wrist or put a strap sensor back on turned, the model sees the same motion on changed axes. REFIT undoes such shifts without labels or retraining. It describes them by families of axis transforms, such as reflections and rotations, and fits each family to the user's data so that simple statistics match those of the training data. The family that removes most of the mismatch names the shift. REFIT fixes the shift by applying the best member of that family before the frozen model and re-estimating its normalization statistics. It tests the fixed model with a label-free accuracy estimate and asks the user to re-wear the sensor when it is low. Experiments on real left/right sensor pairs and on real and simulated re-attachment show that REFIT outperforms label-free test-time adaptation methods on every dataset and restores most of the accuracy lost to re-attachment. It names injected shifts far more reliably than a confidence-based selector. After a correction over all signed permutations of the axes, the estimate separates successful from failed corrections.

0.24

ArmPoser: Real-Time, Calibration-Free Arm Pose Estimation from Smartwatch IMU

cs.CV cs.HC ·2026-09-08 ·Bishnu Dev, Vasco Xu, Xi-Aan Loh, Chenfeng Gao, Henry Hoffmann +1 more
published similarity 0.64
Abstract

Arm pose estimation enables applications in fitness, extended reality input, rehabilitation, and life logging. Prior smartwatch-based approaches rely on calibration poses and preprocessing pipelines that transform raw IMU measurements into standardized training formats. These steps hinder deployment in everyday settings and introduce errors due to imperfect calibration and sensor drift. We present ArmPoser, a calibration-free arm pose estimation system using a single smartwatch IMU. Our central contribution is training models directly in the reference frame native to consumer smartwatches, aligning learning with how IMU data is produced by deployed devices. By operating on device-native axes, ArmPoser removes the need for coordinate transformations, explicit alignment, and bone-offset calibration used in prior work. We further augment training with physically grounded variations in watch placement and arm morphology to account for user-specific variability. ArmPoser also includes a wear-configuration module that infers anterior or posterior forearm placement and crown orientation. We evaluate pose estimation on public benchmarks and on a 10-participant, 30-activity study using watchOS and Android smartwatches, where ArmPoser matches or exceeds calibrated baselines without any user calibration.

0.28

Learning Human Health and Diseases from 24-hour Wrist Movement

cs.LG ·2026-08-30 ·Yong Wang, Dylan McGagh, Katya Broomberg, Zizheng Zhang, Jonathan Carter +19 more
similarity 0.64
Abstract

Much of human health and function unfolds beyond the clinic, through the movements of everyday life. Wrist-worn accelerometers capture these movements continuously, yet their rich signals are often reduced to a small set of predefined behavioural summary measures. Here, we present Sensori, a self-supervised foundation model that learns general-purpose health representations directly from 24 hours of raw tri-axial wrist movement. We developed and evaluated the model across four population-based cohorts from the United Kingdom, China and the United States, comprising 122,640 participants contributing 683,617 person-days of free-living recordings. Sensori condensed each day of movement into a representation that captured diverse movement behaviours, demographic characteristics, health axes and physical function. Evaluation in independent cohorts showed that these representations generalised across populations and measurement settings without retraining. When added to common clinical covariates, Sensori significantly improved prevalent disease classification for 52 of 102 eligible conditions (median delta AUROC, 0.060; range, 0.012-0.242) and incident disease risk prediction for 26 of 87 eligible conditions (median delta Uno's C-index, 0.064; range, 0.025-0.172), with the largest gains for neurological and psychiatric disorders. These findings establish 24-hour wrist movement as a rich and scalable source of health information, with the potential to support passive health monitoring and disease prediction at population scale.

0.29