A Portable Multichannel Kilohertz Current Stimulator for Selective Peripheral Transcutaneous Stimulation

Jiatong Jiang, Andrea Bottin, Simos Koutsoftidis, Enrico Merlo, Georgios Gryparis, Yongkun Zhao, Deren Y. Barsakcioglu, Dario Farina, E. M. Drakakis

eess.SP ·submitted 2026-09-19 15:18 UTC · v1
unusual

Abstract

We present SineStim, a portable, 12-channel current stimulator for transcutaneous spinal cord stimulation and peripheral electrical stimulation at kilohertz frequencies. Each channel delivers independent, current-controlled sinusoidal waveforms with amplitudes from 0 to 50 mA (0.1 mA resolution) and frequencies from 0 to 50 kHz (0.1 Hz resolution), with burst modulation modes supported. A custom output stage with a high compliance voltage of $\pm$ 120 V was designed and developed, with galvanically isolated channels and independently programmable stimulation parameters for each channel. The stimulator performance was tested on both passive loads and human subjects. Benchtop characterisation on resistive and resistive-capacitive loads demonstrated a total harmonic distortion between 1 - 8 % across typical operating conditions. Multichannel functionality was demonstrated in two-channel human forearm stimulation experiments. Burst-modulated waveforms with differing channel amplitudes modulated inter-finger force ratios, and channels with small frequency offsets elicited temporal interference force patterns at the beat frequency. Smoothly enveloped bursts of kilohertz sinusoidal waveforms produced negligible stimulation artifacts at steady state in concurrent surface electromyography (sEMG) recordings at motor threshold, in contrast to conventional biphasic square wave stimulation. SineStim delivers precise, isolated, multichannel kilohertz stimulation through a portable device, with performance demonstrated on both benchtop loads and human participants. By combining multichannel spatial control with minimal-artifact sEMG compatibility, SineStim enables future precision non-invasive neural stimulation paradigms based on multichannel optimisation and real-time closed-loop control capabilities not available via existing single-channel stimulators.

Comment
12 pages, 10 figures, to be submitted to journal

Closest papers

Nearest neighbours by meaning across the whole index.

A Co-Located MMG-FES Wearable Interface for Action-Updated State-Gated Stimulation

cs.HC ·2026-10-11 ·Cong Liu, Xiao Jin, Zhenhua Yu
similarity 0.56
Abstract · 9 pages, 8 figures. Submitted to IEEE Robotics and Automation Letters

Functional electrical stimulation (FES) assists movement, but fixed schedules cannot track how a repeatedly activated muscle changes, and surface electromyography (EMG) near the stimulation electrodes is often obscured by artifacts. Prior work recorded mechanomyography (MMG) passively during closed-loop FES cycling and estimated FES-induced fatigue or predicted fatigue for FES control, without gating stimulation with stimulated-site MMG. In this study, we present VG-FES, a wearable module co-locating microphone-based MMG, programmable charge-balanced biphasic stimulation, and embedded state-gated control at one on-skin thigh site. After each action, we compare rectus femoris (RF) mean power frequency (MPF) with an early-session baseline of the same direction, giving a relative state. A threshold on its window means enables fixed-duration bursts separated by rest periods. During onboard stimulation, MMG remained recordable, whereas near-site EMG was artifact-dominated. Under prolonged external stimulation, cycle-wise MMG tracked an independent local-pressure reference (Spearman rho = 0.968). In leave-one-session-out evaluation on 2284 squat actions (11 sessions, eight participants), MMG-based action segmentation reached an event-detection F1 of 0.923 and direction classification a balanced accuracy of 0.925. Online, over 15.69 min of self-paced squats, one participant received four bursts while MMG acquisition and action monitoring continued. Mechanical feedback from the stimulated site offers wearable FES and assistive robotics a per-action basis for state-gated stimulation.

0.40

ElectroCalm: Investigating User Experience and Physiological Responses to Multi-Node Transcutaneous Electrical Stimulation for Stress Modulation

cs.HC ·2026-10-15 ·Yoon Kyung Shon, Pablo E. Paredes
published similarity 0.55
Abstract · 25 pages, 6 figures, to appear in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies, Vol. 10, No. 4, Decem…

Transcutaneous Electrical Stimulation (TES) for stress modulation has largely focused on vagus nerve stimulation at the neck, yet two questions remain underexplored: how users experience electrotactile sensations at this sensitive site, and whether electrotactile feedback itself can function as a haptic stress intervention. To investigate this gap, we applied an 8-node TES array to two body sites during a cognitively demanding 2-back task: the neck, a site used in prior vagal TES research for its anatomical proximity to the cervical vagus nerve, and the arm, the most common haptic wearable site, which primarily provides cutaneous electrotactile sensation without vagal access. In a usability study, both sites were rated as comparably comfortable without disrupting task performance, though the same stimulation was interpreted differently across sites. A second study assessing the physiological effects of active versus inactive stimulation under identical electrode attachment revealed that only neck TES produced cortical and autonomic changes consistent with stress modulation, while arm TES did not differ from inactive conditions. These findings suggest that neck TES can be acceptable despite the site's sensitivity, and that both the physiological effects and the sensory experience of TES depend on placement.

0.43

Bio-Inspired Electrotactile Feedback: A Framework and Impacts of Multimodal Cues

cs.HC cs.ET ·2026-10-13 ·Melika Emami, Amirhossein Bayat, Rahim Tafazolli, Atta Quddus
similarity 0.53
Abstract

Electrotactile stimulation, as a haptic feedback method, often struggles to evoke high-quality natural sensations. Consequently, despite its practical advantages, it is generally less preferred in human-machine systems than mechanical approaches. In this paper, we propose a bio-inspired stimulation framework that generates signals modelled on afferent neural activity derived from a touch model. By producing more biologically plausible spiking patterns, the proposed approach aims to enhance the realism of perceived tactile sensations. To evaluate these stimulation patterns in a realistic task context and to quantify the influence of visual and movement cues, we conducted a series of subjective experiments under three conditions. The results indicate that bio-inspired modulation was effective: in particular, bio-inspired co-modulation of amplitude and frequency achieved a favourable pressure-irritation trade-off, increasing the probability of perceiving pressure while maintaining low irritation (pressure: 0.78; irritation: 0.24) relative to the other patterns. Visual cues and hand movement further improved feedback quality by significantly increasing the probability of reporting pressure (p$<$0.001) without a corresponding increase in irritation, and by increasing mean naturalness ratings. Overall, these findings demonstrate the potential of bio-inspired electrotactile patterns to improve haptic feedback quality, and highlight the importance of evaluating such methods under realistic, multimodal interaction scenarios.

0.29

Towards an Earpiece for Wearable and Dry Ultrasonic Vagus Nerve Stimulation

eess.SY ·2026-10-05 ·Sebastian Frey, Farouk Ghezraoui, Marc Nölke, Marco Giordano, Luca Benini +1 more
unusual similarity 0.50
Abstract · 4 pages, 3 figures

Ultrasound (US)-based auricular vagus nerve stimulation (aVNS) is emerging as a versatile, noninvasive modality for neuromodulation - spanning clinical therapies (e.g., pain management, depression) and general well-being applications. However, most existing US-based aVNS systems remain bulky and require wet coupling media (e.g., ultrasound gel) to achieve both spatially localized stimulation and efficient acoustic transmission. We present a wearable US stimulation system combining a personalized, dry-coupled earpiece with a battery-powered, wireless US probe. The earpiece integrates a 2 MHz piezoelectric transducer fully encapsulated in Humimic material designed for anatomical fit and stable coupling without externally applied gel. Hydrophone measurements of the fully encapsulated earpiece in water give a peak rarefactional pressure of 0.24 MPa at 15 mm for a 15 V unipolar excitation. We further demonstrate in vivo feasibility through fully dry, in-ear 2 MHz pulse-echo acquisitions under realistic wearing conditions, confirming effective US transmission without the need for coupling gel. These results demonstrate the integration of a personalized dry acoustic interface with battery-powered stimulation electronics, providing a wearable platform for investigating US-based aVNS. Future studies will focus on functional outcomes, including heart rate variability and pupillary responses during stimulation.

0.27

A Dry-Contact Ear-EEG System With Continuous Electrode-Skin Impedance Mismatch Monitoring for Motion Artifact Cancellation Using DRL Stimulus

eess.SP eess.SY ·2026-09-02 ·Lohan Atapattu, Sajitha Madugalle, Imasha Nethmal, Erandee Jayathilaka, Avishka Herath +4 more
published similarity 0.48
Abstract · 5 pages, 4 figures, accepted for presentation at IEEE BioCAS 2026

Dry-contact ear-electroencephalography (Ear-EEG) enables wearable neural monitoring. However, motion induced electrode-skin impedance (ESI) mismatches between electrodes can severely degrade signal quality. To the best of our knowledge, this paper presents the first proof-of-concept dry-contact EarEEG system that uses a driven-right-leg (DRL) stimulus for continuous ESI mismatch monitoring, enabling online adaptive motion artifact cancellation. A 1 kHz sinusoidal stimulus is injected through the DRL electrode. The resulting response to the injected carrier is separated from the EEG using bandpass filtering and demodulation, and then used to extract the ESI mismatch information as the reference input for a normalized least-mean-square adaptive filter followed by a Hampel filtering stage. To evaluate artifact suppression and preservation of neural activity, alpha-band EEG activity was analyzed involving four healthy participants performing head nodding, electrode tapping, and jaw clenching. The system achieved artifact power reductions of 6.5, 12.6, and 9.0 dB (77.6%, 92.8%, and 86.4%, respectively) while alpha-band modulation remained clearly observable after processing. This demonstrates the feasibility of DRL-stimulusbased ESI mismatch monitoring for motion artifact cancellation in wearable dry-contact Ear-EEG.

0.38

Bidirectional Wireless Communication for Weakly Coupled Implantable Brain-Computer Interfaces

eess.SY ·2026-09-05 ·Shreyas Sen, Baibhab Chatterjee, Gourab Barik, Anirudh Roy
benchmark similarity 0.48
Abstract · 33 pages, 4 figures, 2 Tables

Implantable brain-computer interfaces (BCIs) promise transformative societal impact, from restoring lost motor, sensory, and speech function in patients with paralysis, stroke, sclerosis, and sensory deficits to serving as a high-bandwidth conduit between human cognition and machine intelligence. Realizing these visions requires moving from laboratory prototypes to chronic clinical systems that support thousands to millions of electrodes, several millimeters to centimeters deep beneath the brain surface, under strict heating and size limits. Almost every clinically relevant implant therefore operates in a weakly coupled regime, with coupling coefficients of $10^{-3}$ to $10^{-1}$ across centimetres of lossy tissue. In this regime, the wireless channel sets the limits of power-transfer efficiency, communication bandwidth, and energy per bit. We review the recent progress of bidirectional wireless links across inductive, mid-field, RF, ultrasonic, magnetoelectric, optical, UWB, and electro-quasistatic modalities, and benchmark them against the clinical axes of depth, size, and data rate. Within an approximately 10 mW communication budget set by the approximately $1^\circ$C tissue-heating ceiling, narrowband high-Q links are well suited for power transfer and low-speed data, but at 1-10 nJ/b cannot reach the greater than 10 Mbps to tens of Gbps uplinks that thousand- to million-channel interfaces demand, even with aggressive on-implant compression. This calls for sub-10 pJ/b and ultimately sub-1 pJ/b wireless links, where wideband techniques, such as ultra-wideband (UWB) and brain-channel communication (BCC), are suitable. We close with a quantitative framework for analyzing such wireless links and a co-design roadmap across electromagnetics, circuits, packaging, security, and regulation, toward secure, networked, million-channel brain interfaces.

0.34

A spinal-inspired spiking neural network for continuous finger-joint kinematics estimation from high-density surface EMG

cs.HC ·2026-10-25 ·Cristian David Guerrero-Mendez, Leonardo Abdala Elias
similarity 0.47
Abstract · 32 pages (25 pages of main text and 7 pages of supplementary material), 9 figures, 1 table

Decoding simultaneous and proportional finger kinematics from high-density surface electromyography (HD sEMG) remains challenging. Although data-driven methods have shown promising performance for finger movement decoding, their limited physiological interpretability remains a relevant limitation. This study proposes and evaluates a spiking neural network (SNN) that incorporates spinal-inspired structures and mechanisms to predict multi-joint finger kinematics from HD sEMG signals. The spinal-inspired SNN includes a spike-encoding computational model with input-noise variability, a phenomenological representation of Henneman's size principle, and excitation/inhibition (E/I) balance. HD sEMG and kinematic data were collected from 23 healthy participants performing grasping tasks under different elbow and wrist postures. Performance was assessed using six prediction metrics and compared against six baseline machine learning and deep learning methods. The proposed method showed a large and significant ($p<0.05$, rank-biserial correlation $r_{rb}>0.7$) improvement over all baseline methods across all accuracy metrics. Performance improved significantly with increasing spike encoder firing rates up to approximately 83 Hz, and with more regular input spike trains compared with a Poisson-like encoder. In contrast, the E/I balance did not significantly affect the decoding performance of the algorithm. The firing rate and inter-spike interval statistics of the SNN differed significantly across motor tasks. These results demonstrate that incorporating neurophysiological principles into SNNs improves prediction performance while providing additional physiological interpretability for simultaneous and proportional finger-kinematics decoding. This approach represents a promising step toward physiology-informed neural networks, with potential applications in motor rehabilitation.

0.23

A Mechanomyography-Based Integrated Sensing-Stimulation System for Fatigue-Aware Neuromuscular Therapy

cs.HC ·2026-10-11 ·Xiao Jin, Cong Liu, Zhenhua Yu
similarity 0.47
Abstract · 12 pages, 14 figures

Muscle fatigue limits the effectiveness of functional electrical stimulation (FES), yet fatigue monitoring during active stimulation remains challenging because electromyography (EMG) is severely contaminated by stimulation artifacts. To address this issue, this study proposes an integrated mechanomyography-based sensing framework (MMG-FES) for artifact-resistant fatigue monitoring during stimulation. Fatigue states were first characterized during voluntary movement using established EMG spectral indicators, including median frequency (MF) and mean power frequency (MPF), and then linked to MMG-derived features, including high-frequency energy ratio (HFER) and spectral bandwidth (BW), for fatigue recognition under stimulation conditions. Experimental results showed consistent fatigue-related trends, with EMG spectral features decreasing and MMG features exhibiting coordinated spectral redistribution across repeated contractions. Using these features, the proposed framework achieved fatigue-state recognition accuracies of 0.93 and 0.96 with logistic regression and random forest, respectively. These findings support MMG as a physiologically meaningful and stimulation-compatible modality for fatigue-aware closed-loop neuromuscular stimulation.

0.42