Towards an Earpiece for Wearable and Dry Ultrasonic Vagus Nerve Stimulation

Sebastian Frey, Farouk Ghezraoui, Marc Nölke, Marco Giordano, Luca Benini, Christoph Leitner

eess.SY ·submitted 2026-10-05 12:57 UTC · v1
unusual

Abstract

Ultrasound (US)-based auricular vagus nerve stimulation (aVNS) is emerging as a versatile, noninvasive modality for neuromodulation - spanning clinical therapies (e.g., pain management, depression) and general well-being applications. However, most existing US-based aVNS systems remain bulky and require wet coupling media (e.g., ultrasound gel) to achieve both spatially localized stimulation and efficient acoustic transmission. We present a wearable US stimulation system combining a personalized, dry-coupled earpiece with a battery-powered, wireless US probe. The earpiece integrates a 2 MHz piezoelectric transducer fully encapsulated in Humimic material designed for anatomical fit and stable coupling without externally applied gel. Hydrophone measurements of the fully encapsulated earpiece in water give a peak rarefactional pressure of 0.24 MPa at 15 mm for a 15 V unipolar excitation. We further demonstrate in vivo feasibility through fully dry, in-ear 2 MHz pulse-echo acquisitions under realistic wearing conditions, confirming effective US transmission without the need for coupling gel. These results demonstrate the integration of a personalized dry acoustic interface with battery-powered stimulation electronics, providing a wearable platform for investigating US-based aVNS. Future studies will focus on functional outcomes, including heart rate variability and pupillary responses during stimulation.

Comment
4 pages, 3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Bidirectional Wireless Communication for Weakly Coupled Implantable Brain-Computer Interfaces

eess.SY ·2026-09-05 ·Shreyas Sen, Baibhab Chatterjee, Gourab Barik, Anirudh Roy
benchmark similarity 0.52
Abstract · 33 pages, 4 figures, 2 Tables

Implantable brain-computer interfaces (BCIs) promise transformative societal impact, from restoring lost motor, sensory, and speech function in patients with paralysis, stroke, sclerosis, and sensory deficits to serving as a high-bandwidth conduit between human cognition and machine intelligence. Realizing these visions requires moving from laboratory prototypes to chronic clinical systems that support thousands to millions of electrodes, several millimeters to centimeters deep beneath the brain surface, under strict heating and size limits. Almost every clinically relevant implant therefore operates in a weakly coupled regime, with coupling coefficients of $10^{-3}$ to $10^{-1}$ across centimetres of lossy tissue. In this regime, the wireless channel sets the limits of power-transfer efficiency, communication bandwidth, and energy per bit. We review the recent progress of bidirectional wireless links across inductive, mid-field, RF, ultrasonic, magnetoelectric, optical, UWB, and electro-quasistatic modalities, and benchmark them against the clinical axes of depth, size, and data rate. Within an approximately 10 mW communication budget set by the approximately $1^\circ$C tissue-heating ceiling, narrowband high-Q links are well suited for power transfer and low-speed data, but at 1-10 nJ/b cannot reach the greater than 10 Mbps to tens of Gbps uplinks that thousand- to million-channel interfaces demand, even with aggressive on-implant compression. This calls for sub-10 pJ/b and ultimately sub-1 pJ/b wireless links, where wideband techniques, such as ultra-wideband (UWB) and brain-channel communication (BCC), are suitable. We close with a quantitative framework for analyzing such wireless links and a co-design roadmap across electromagnetics, circuits, packaging, security, and regulation, toward secure, networked, million-channel brain interfaces.

0.34

A Portable Multichannel Kilohertz Current Stimulator for Selective Peripheral Transcutaneous Stimulation

eess.SP ·2026-09-19 ·Jiatong Jiang, Andrea Bottin, Simos Koutsoftidis, Enrico Merlo, Georgios Gryparis +4 more
unusual similarity 0.50
Abstract · 12 pages, 10 figures, to be submitted to journal

We present SineStim, a portable, 12-channel current stimulator for transcutaneous spinal cord stimulation and peripheral electrical stimulation at kilohertz frequencies. Each channel delivers independent, current-controlled sinusoidal waveforms with amplitudes from 0 to 50 mA (0.1 mA resolution) and frequencies from 0 to 50 kHz (0.1 Hz resolution), with burst modulation modes supported. A custom output stage with a high compliance voltage of $\pm$ 120 V was designed and developed, with galvanically isolated channels and independently programmable stimulation parameters for each channel. The stimulator performance was tested on both passive loads and human subjects. Benchtop characterisation on resistive and resistive-capacitive loads demonstrated a total harmonic distortion between 1 - 8 % across typical operating conditions. Multichannel functionality was demonstrated in two-channel human forearm stimulation experiments. Burst-modulated waveforms with differing channel amplitudes modulated inter-finger force ratios, and channels with small frequency offsets elicited temporal interference force patterns at the beat frequency. Smoothly enveloped bursts of kilohertz sinusoidal waveforms produced negligible stimulation artifacts at steady state in concurrent surface electromyography (sEMG) recordings at motor threshold, in contrast to conventional biphasic square wave stimulation. SineStim delivers precise, isolated, multichannel kilohertz stimulation through a portable device, with performance demonstrated on both benchtop loads and human participants. By combining multichannel spatial control with minimal-artifact sEMG compatibility, SineStim enables future precision non-invasive neural stimulation paradigms based on multichannel optimisation and real-time closed-loop control capabilities not available via existing single-channel stimulators.

0.28

A Co-Located MMG-FES Wearable Interface for Action-Updated State-Gated Stimulation

cs.HC ·2026-10-11 ·Cong Liu, Xiao Jin, Zhenhua Yu
similarity 0.49
Abstract · 9 pages, 8 figures. Submitted to IEEE Robotics and Automation Letters

Functional electrical stimulation (FES) assists movement, but fixed schedules cannot track how a repeatedly activated muscle changes, and surface electromyography (EMG) near the stimulation electrodes is often obscured by artifacts. Prior work recorded mechanomyography (MMG) passively during closed-loop FES cycling and estimated FES-induced fatigue or predicted fatigue for FES control, without gating stimulation with stimulated-site MMG. In this study, we present VG-FES, a wearable module co-locating microphone-based MMG, programmable charge-balanced biphasic stimulation, and embedded state-gated control at one on-skin thigh site. After each action, we compare rectus femoris (RF) mean power frequency (MPF) with an early-session baseline of the same direction, giving a relative state. A threshold on its window means enables fixed-duration bursts separated by rest periods. During onboard stimulation, MMG remained recordable, whereas near-site EMG was artifact-dominated. Under prolonged external stimulation, cycle-wise MMG tracked an independent local-pressure reference (Spearman rho = 0.968). In leave-one-session-out evaluation on 2284 squat actions (11 sessions, eight participants), MMG-based action segmentation reached an event-detection F1 of 0.923 and direction classification a balanced accuracy of 0.925. Online, over 15.69 min of self-paced squats, one participant received four bursts while MMG acquisition and action monitoring continued. Mechanical feedback from the stimulated site offers wearable FES and assistive robotics a per-action basis for state-gated stimulation.

0.40

Thickness-Field-Excited Bimorph Piezoelectric Micromachined Ultrasonic Transducer in Submicrometer Thin-Film Lithium Niobate

eess.SP ·2026-11-09 ·Vakhtang Chulukhadze, Jiajun Huang, Zihuan Liu, Will Leskowitz, Tzu-Hsuan Hsu +6 more
similarity 0.48
Abstract · 8 pages, 11 figures

This work presents the first demonstration of a submicrometer-thick thickness-field-excited (TFE) lithium niobate (LN) flexural-mode piezoelectric micromachined ultrasonic transducer (PMUT). A 670-nm-thick bilayer periodically poled piezoelectric film (P3F) 128Y LN is used to demonstrate a suspended membrane with an area of 0.25 mm$^{2}$, achieving a low resonance frequency of 33.4 kHz for airborne transduction. Its electrical measurements reveal an extracted effective electromechanical coupling efficiency ($k_{\mathrm{eff}}^{2}$) of 3% and a moderate static capacitance $C_0$ of 17 pF. Meanwhile, mechanical measurements using a laser Doppler vibrometer (LDV) yield a high quasi-static peak out-of-plane displacement ($ξ_{\mathrm{static}}$) of 145 nm/V and a high corresponding open-circuit sensitivity ($S_{\mathrm{OC}}$) of 1.4 mV/Pa in the audio band. The fabricated device is compared with state-of-the-art (SoA) airborne piezoelectric transducers with sub-100-kHz resonance frequencies, underscoring the potential of the TFE P3F LN transducer platform by simultaneously demonstrating strong actuation capability while featuring high sensitivity.

0.33

HDR-DTCP: High-Dynamic-Range Differential Tissue-Coupled Wireless Powering for Tunable Biphasic Stimulation in Injectable Implants

eess.SP eess.SY ·2026-11-14 ·Asif Iftekhar Omi, Anyu Jiang, Han Wu, Sultan Mahmud, Mali Halac +4 more
similarity 0.47
Abstract

Next-generation implantable neurostimulators require efficient wireless power delivery in smaller, less invasive form factors, yet variations in tissue coupling, implantation conditions, and stimulation loads can alter received power (or requirements) and degrade energy-harvesting performance. This work presents high-dynamic-range (HDR) differential tissue-coupled powering (DTCP), termed HDR-DTCP, a body-coupled architecture in which noninvasive differential electrodes establish an AC electric field in tissue and a thread-like implant extracts power from the longitudinal potential gradient for on-chip harvesting and stimulation. Distributed coupling along the implant length, rather than receiver cross-section, enables minimally invasive injectable geometries, with harvested power scaling with implant length. A 65-nm complementary metal-oxide-semiconductor (CMOS) prototype integrates a reconfigurable four-stage energy harvester with automatic stage selection and a tunable constant-current biphasic stimulator, achieving 63.5\% peak power-conversion efficiency (PCE) at $-16.3$ dBm and $>50\%$ PCE over a 9-dB input-power range. Preliminary in-vivo validation of DTCP was done with a second application-specific integrated circuit (ASIC) on an injectable flexible substrate, capable of being delivered through a 14-gauge needle adjacent to the sciatic nerve of Sprague-Dawley rats (n=4). External copper-pad DTCP powering evoked repeatable hind-limb twitches and electromyography (EMG) response; ultrasound confirmed sub-millimeter nerve proximity, video-based paw-tip tracking captured the response, and 8-day post-implant dissection verified placement along the sciatic-nerve trajectory. Overall, this work provides an integrated wireless powering, energy-harvesting, and stimulation platform toward fully battery-free injectable neuromodulation implants.

0.21

WAVES: Wearable Active Vibroacoustic Elasticity Sensing for Low-Cost and Non-Invasive Muscle Stiffness Monitoring

cs.ET ·2026-11-04 ·Shubham Rohal, Dong Yoon Lee, Shijia Pan
similarity 0.47
Abstract

Muscle stiffness is a physiologically meaningful biomarker associated with a wide range of musculoskeletal and neurological conditions. However, existing muscle stiffness assessment methods, such as shear wave elastography (SWE), manual palpation, and handheld mechanical probes, remain impractical for continuous, everyday monitoring due to bulky hardware, operator dependence, and limited self-use. Meanwhile, wearable muscle-sensing modalities such as Electromyography (EMG) and Mechanomyography (MMG) primarily capture muscle activation rather than passive mechanical properties of tissue at rest, leaving a critical gap in portable monitoring of resting muscle stiffness. In this work, we present WAVES, a wearable system for continuous monitoring of muscle stiffness via active vibroacoustic sensing. WAVES injects controlled vibroacoustic excitation into soft tissue and estimates muscle stiffness by measuring shear-wave propagation velocity through Time-Difference-of-Arrival (TDoA) analysis across spatially distributed wearable sensors. To achieve accurate TDoA estimation with low-cost wearable hardware, we develop a physiology- and quality-guided vibroacoustic sensing framework that effectively screens and refines TDoA for accurate stiffness estimation. We evaluate WAVES through characterization experiments using ballistic jelly and end-to-end on-body evaluation with human participants. Results demonstrate that WAVES can robustly estimate muscle stiffness across multiple users and different superficial muscles while enabling lightweight, wearable deployment for everyday use. WAVES is able to achieve a muscle stiffness estimation error of 13.1% or less across multiple users and multiple muscle groups.

0.25

Finger-to-Ear ECG: Systematic Evaluation of an Earbud-Based Cardiac Monitoring Approach

cs.HC ·2026-09-21 ·Philipp Lepold, Paula Breitling, Jonas Hummel, Tobias Röddiger, Michael Beigl
published similarity 0.46
Abstract

Ear-ECG enables unobtrusive cardiac monitoring, but existing approaches often struggle with low signal amplitudes and limited morphology preservation. We evaluate a finger-to-ear ECG paradigm that combines an in-ear electrode with a rear housing finger-contact electrode in a speaker-equipped earbud. A study with 30 participants investigated four finger-to-ear electrode geometries against chest-reference ECG and additionally assessed robustness under music playback, talking, and walking disturbances. Left-finger configurations achieved R peak detection F1-scores >99% with high agreement of key ECG morphology features. In contrast, right finger configurations as well as walking led to severe signal degradation. The results reveal a trade-off: while cross-body setups provided the highest signal fidelity, users preferred same-side contacts for comfort reasons. This establishes finger-to-ear ECG as a robust, morphology-aware paradigm for opportunistic sensing in earables.

0.38

Sensing Bone-Conducted Speech with Earbuds

eess.AS ·2026-09-02 ·Christoph Weyer, Peter Jax
published similarity 0.46
Abstract · 14 pages, 12 figures, journal

Clear capture of the wearer's own voice (OV) is essential when using earbuds for mobile communication. However, OV capture remains challenging in noisy environments. Bone-conducted (BC) speech, which can be sensed as vibrations of the earbud housing, can be used to improve OV capture. However, neither bandwidth nor spatial characteristics of OV-induced earbud vibrations have been analyzed in detail, despite both characteristics being relevant, e.g., for sensor choice and placement. This study investigates both characteristics, based on measurements with two earbud models. Spectrally, results indicate that OV-induced earbud vibrations exhibit a low-pass characteristic, with a steep roll-off of -93 dB per decade above 400 Hz. Thus, sensors with comparatively low noise floors are required to sense the vibrations above \SI{1}{\kilo\hertz}. Spatially, results indicate that the earbuds mainly vibrate in and out of the ear canal entrance, with high consistency between subjects and fits. Simulations confirm that this enables capture of the high-power vibrations below 400 Hz by a single-axis sensor with less than 1.5 dB mean attenuation.

0.39