CS Paper Radar

HDR-DTCP: High-Dynamic-Range Differential Tissue-Coupled Wireless Powering for Tunable Biphasic Stimulation in Injectable Implants

Asif Iftekhar Omi, Anyu Jiang, Han Wu, Sultan Mahmud, Mali Halac, Shreyas Sen, Shriya Srinivasan, Adam Khalifa, Baibhab Chatterjee

eess.SP eess.SY ·submitted 2026-11-14 04:18 UTC · v1

Abstract

Next-generation implantable neurostimulators require efficient wireless power delivery in smaller, less invasive form factors, yet variations in tissue coupling, implantation conditions, and stimulation loads can alter received power (or requirements) and degrade energy-harvesting performance. This work presents high-dynamic-range (HDR) differential tissue-coupled powering (DTCP), termed HDR-DTCP, a body-coupled architecture in which noninvasive differential electrodes establish an AC electric field in tissue and a thread-like implant extracts power from the longitudinal potential gradient for on-chip harvesting and stimulation. Distributed coupling along the implant length, rather than receiver cross-section, enables minimally invasive injectable geometries, with harvested power scaling with implant length. A 65-nm complementary metal-oxide-semiconductor (CMOS) prototype integrates a reconfigurable four-stage energy harvester with automatic stage selection and a tunable constant-current biphasic stimulator, achieving 63.5\% peak power-conversion efficiency (PCE) at $-16.3$ dBm and $>50\%$ PCE over a 9-dB input-power range. Preliminary in-vivo validation of DTCP was done with a second application-specific integrated circuit (ASIC) on an injectable flexible substrate, capable of being delivered through a 14-gauge needle adjacent to the sciatic nerve of Sprague-Dawley rats (n=4). External copper-pad DTCP powering evoked repeatable hind-limb twitches and electromyography (EMG) response; ultrasound confirmed sub-millimeter nerve proximity, video-based paw-tip tracking captured the response, and 8-day post-implant dissection verified placement along the sciatic-nerve trajectory. Overall, this work provides an integrated wireless powering, energy-harvesting, and stimulation platform toward fully battery-free injectable neuromodulation implants.

Closest papers

Nearest neighbours by meaning across the whole index.

Bidirectional Wireless Communication for Weakly Coupled Implantable Brain-Computer Interfaces

eess.SY ·2026-09-05 ·Shreyas Sen, Baibhab Chatterjee, Gourab Barik, Anirudh Roy
benchmark similarity 0.62
Abstract · 33 pages, 4 figures, 2 Tables

Implantable brain-computer interfaces (BCIs) promise transformative societal impact, from restoring lost motor, sensory, and speech function in patients with paralysis, stroke, sclerosis, and sensory deficits to serving as a high-bandwidth conduit between human cognition and machine intelligence. Realizing these visions requires moving from laboratory prototypes to chronic clinical systems that support thousands to millions of electrodes, several millimeters to centimeters deep beneath the brain surface, under strict heating and size limits. Almost every clinically relevant implant therefore operates in a weakly coupled regime, with coupling coefficients of $10^{-3}$ to $10^{-1}$ across centimetres of lossy tissue. In this regime, the wireless channel sets the limits of power-transfer efficiency, communication bandwidth, and energy per bit. We review the recent progress of bidirectional wireless links across inductive, mid-field, RF, ultrasonic, magnetoelectric, optical, UWB, and electro-quasistatic modalities, and benchmark them against the clinical axes of depth, size, and data rate. Within an approximately 10 mW communication budget set by the approximately $1^\circ$C tissue-heating ceiling, narrowband high-Q links are well suited for power transfer and low-speed data, but at 1-10 nJ/b cannot reach the greater than 10 Mbps to tens of Gbps uplinks that thousand- to million-channel interfaces demand, even with aggressive on-implant compression. This calls for sub-10 pJ/b and ultimately sub-1 pJ/b wireless links, where wideband techniques, such as ultra-wideband (UWB) and brain-channel communication (BCC), are suitable. We close with a quantitative framework for analyzing such wireless links and a co-design roadmap across electromagnetics, circuits, packaging, security, and regulation, toward secure, networked, million-channel brain interfaces.

0.34

An Implant-to-Wearable IR-UWB Transmitter-Receiver Architecture and Layered Protocol for High-Density Brain-Computer Interfaces

eess.SP cs.AI ·2026-09-01 ·G. D. Su, Y. Mo
similarity 0.50
Abstract · 18 pages,14 figures

High-rate neural telemetry requires an implant-towearable link whose circuit partition, waveform mapping, packet processing, and failure semantics are mutually consistent. This paper specifies a chip-oriented, one-way impulse-radio ultrawideband (IR-UWB) uplink comprising an implanted packet engine and free-running transmitter, a tissue-proxy channel, and a wearable mixed-signal receiver and digital baseband.

0.27

Neural implants and human safety: single-fault detection for DC-coupled recording front ends

eess.SP cs.HC ·2026-08-11 ·Dimitris Antoniadis, Timothy Constandinou
similarity 0.49
Abstract · Draft IEEE 4 + 1

DC-coupled analogue front ends (AFEs) for neural implants provide a low-area solution. However, removing the coupling capacitor eliminates the intrinsic barrier that protects cortical tissue: a single-fault event, such as gate-oxide breakdown of a low-noise amplifier (LNA) input transistor, can open a direct DC path from the supply rail into the brain. On the stimulation side this hazard is well understood, and single-fault tolerance is enforced by a series DC-blocking capacitor; on the recording side, DC-coupled front ends discard the equivalent safeguard, yet their protection has gone almost unexamined. This paper presents a single-fault detection mechanism that monitors the LNA for the DC imbalance produced by such a failure and disables the amplifier before the resulting fault current can irreversibly damage tissue. The imbalance is encoded in the duty cycle of a current-starved relaxation oscillator and read out as a time-to-digital measurement. Designed in 65 nm, the mechanism resolves a worst-case fault of 6.4 nA across all corners within 0.81 ms - compliant with the ISO~14708-3 limit for an 8533 um2 electrode - opening a broader discussion of safety in DC-coupled recording.

0.04

A Voltage-controlled MTJ-CMOS Neuron Emulating Tunable Izhikevich-Inspired Dynamics

cs.ET cs.ARcs.NE ·2026-09-25 ·Kayode Oluwaseyi Adebunmi, Jordan Athas, Allison Fleming, Hamed Poursiami, Giorgio A. Ascoli +3 more
similarity 0.48
Abstract

Biological neurons exhibit diverse firing dynamics that enable adaptive and stimulus-dependent signalling, yet reproducing these dynamics in hardware has remained an enduring challenge. In this work, we present an Izhikevich- inspired reconfigurable neuron that co-designs voltage-controlled magnetic tunnel junction (V-MTJ) dynamics with CMOS circuitry. The proposed architecture combines V-MTJ excitability dynamics, enabled by a tunable energy landscape, with CMOS recovery dynamics to generate five distinct neuronal firing pat- terns with different spiking, bursting and response characteristics. Our results, based on measured V-MTJ characteristics and circuit simulations using com- mercial GlobalFoundries 22-nm FD-SOI CMOS technology, show an average energy consumption of 145.44 fJ per spike. Algorithmic simulations further show that these firing dynamics reduce inference spike activity by up to 88.6% while maintaining baseline classification accuracy. These results highlight the potential of V-MTJ/CMOS reconfigurable neurons to reduce computational activity and enable compact, energy-efficient brain-inspired computing systems.

0.09

Towards an Earpiece for Wearable and Dry Ultrasonic Vagus Nerve Stimulation

eess.SY ·2026-10-05 ·Sebastian Frey, Farouk Ghezraoui, Marc Nölke, Marco Giordano, Luca Benini +1 more
unusual similarity 0.47
Abstract · 4 pages, 3 figures

Ultrasound (US)-based auricular vagus nerve stimulation (aVNS) is emerging as a versatile, noninvasive modality for neuromodulation - spanning clinical therapies (e.g., pain management, depression) and general well-being applications. However, most existing US-based aVNS systems remain bulky and require wet coupling media (e.g., ultrasound gel) to achieve both spatially localized stimulation and efficient acoustic transmission. We present a wearable US stimulation system combining a personalized, dry-coupled earpiece with a battery-powered, wireless US probe. The earpiece integrates a 2 MHz piezoelectric transducer fully encapsulated in Humimic material designed for anatomical fit and stable coupling without externally applied gel. Hydrophone measurements of the fully encapsulated earpiece in water give a peak rarefactional pressure of 0.24 MPa at 15 mm for a 15 V unipolar excitation. We further demonstrate in vivo feasibility through fully dry, in-ear 2 MHz pulse-echo acquisitions under realistic wearing conditions, confirming effective US transmission without the need for coupling gel. These results demonstrate the integration of a personalized dry acoustic interface with battery-powered stimulation electronics, providing a wearable platform for investigating US-based aVNS. Future studies will focus on functional outcomes, including heart rate variability and pupillary responses during stimulation.

0.27

NORA: Neuro-headstage for Online Recording and Actuation in Freely Behaving Animal Models

eess.SP ·2026-11-11 ·Savanna Blade, Yuhan Hou, He Jia, Laura Kondrataviciute, Runtian Yang +2 more
published similarity 0.46
Abstract · 5 pages, 7 figures. Accepted for publication in IEEE BioCAS 2026. Author accepted manuscript

This paper presents NORA, a compact wireless neuro-headstage designed for simultaneous neural recording and stimulation in freely behaving animal models. Separate recording and stimulation interfaces, each managed with a dedicated MCU and wireless module, are integrated into a fully head-mounted device compatible with standard Omnetics connectors; this separation allows for simultaneous recording and stimulation without sample-dropping or stimulation waveform distortion. To minimize stimulation artifacts and cross-domain interference, the recording and stimulation subsystems are electrically isolated with independent power domains and dedicated wireless communication paths. NORA has been validated through in vivo animal experiments, demonstrating acquisition of meaningful neural features with results comparable to a commercial wireless headstage. Together, these features establish a practical platform for artifact-reduced neuromodulation research.

0.31

Short-Range Microwave Interprobe Coupling in a Brain-Mimicking Phantom and Ex-Vivo Brain

eess.SP ·2026-10-12 ·Pouya Faeghi, Xiaoting Jia, Jeffrey S. Walling
similarity 0.45
Abstract · 8 pages, 10 figures, 3 tables

Objectives: Short-range wireless links (microwave range) between closely spaced devices in brain tissue are relevant to neural interfaces and intracranial sensing, yet the change in coupling between two such devices caused by a finite volume of brain-like tissue has rarely been measured directly. Technology or Method: This work characterizes a printed, microstrip-fed, parasitic-strip-loaded tapered-slot coupling probe in which only a partially inserted 12-mm wire enters the medium, while the printed structure remains outside. Results: Two fabricated probes showed a measured free-space -10-dB reflection band of 5.78 to 6.86 GHz and a fractional bandwidth of approximately 17.1%, consistent with full-wave simulation. In a controlled two-probe experiment, a homogeneous agar-gelatin-saline brain-mimicking phantom was introduced and removed while the probe arrangement and measurement conditions were retained. Introducing the phantom increased the measured transmission coefficient near 6.3 GHz by approximately 16 dB, and this differential was reproduced across repeated trials. More than five measurements in ex vivo goat brain followed the phantom transmission response within approximately 1.5 dB across the 5.78-6.86-GHz band. Time-domain analysis of the phantom-present link gave a system root-mean-square delay spread of approximately 210 ps. Full-wave dosimetry predicted a peak 1-g-averaged specific absorption rate of 1.05 W/kg for approximately 0.49 W accepted power. Conclusions and Clinical or Biological Impact: These results provide an experimentally validated reference for short-range probe coupling in brain-like media and support phantom-based bench evaluation of minimally invasive intracranial probes before in vivo studies.

0.23

A Co-Located MMG-FES Wearable Interface for Action-Updated State-Gated Stimulation

cs.HC ·2026-10-11 ·Cong Liu, Xiao Jin, Zhenhua Yu
similarity 0.45
Abstract · 9 pages, 8 figures. Submitted to IEEE Robotics and Automation Letters

Functional electrical stimulation (FES) assists movement, but fixed schedules cannot track how a repeatedly activated muscle changes, and surface electromyography (EMG) near the stimulation electrodes is often obscured by artifacts. Prior work recorded mechanomyography (MMG) passively during closed-loop FES cycling and estimated FES-induced fatigue or predicted fatigue for FES control, without gating stimulation with stimulated-site MMG. In this study, we present VG-FES, a wearable module co-locating microphone-based MMG, programmable charge-balanced biphasic stimulation, and embedded state-gated control at one on-skin thigh site. After each action, we compare rectus femoris (RF) mean power frequency (MPF) with an early-session baseline of the same direction, giving a relative state. A threshold on its window means enables fixed-duration bursts separated by rest periods. During onboard stimulation, MMG remained recordable, whereas near-site EMG was artifact-dominated. Under prolonged external stimulation, cycle-wise MMG tracked an independent local-pressure reference (Spearman rho = 0.968). In leave-one-session-out evaluation on 2284 squat actions (11 sessions, eight participants), MMG-based action segmentation reached an event-detection F1 of 0.923 and direction classification a balanced accuracy of 0.925. Online, over 15.69 min of self-paced squats, one participant received four bursts while MMG acquisition and action monitoring continued. Mechanical feedback from the stimulated site offers wearable FES and assistive robotics a per-action basis for state-gated stimulation.

0.40