CS Paper Radar

An Implant-to-Wearable IR-UWB Transmitter-Receiver Architecture and Layered Protocol for High-Density Brain-Computer Interfaces

G. D. Su, Y. Mo

eess.SP cs.AI ·submitted 2026-09-01 13:34 UTC · v1

Abstract

High-rate neural telemetry requires an implant-towearable link whose circuit partition, waveform mapping, packet processing, and failure semantics are mutually consistent. This paper specifies a chip-oriented, one-way impulse-radio ultrawideband (IR-UWB) uplink comprising an implanted packet engine and free-running transmitter, a tissue-proxy channel, and a wearable mixed-signal receiver and digital baseband.

Comment
18 pages,14 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Bidirectional Wireless Communication for Weakly Coupled Implantable Brain-Computer Interfaces

eess.SY ·2026-09-05 ·Shreyas Sen, Baibhab Chatterjee, Gourab Barik, Anirudh Roy
benchmark similarity 0.62
Abstract · 33 pages, 4 figures, 2 Tables

Implantable brain-computer interfaces (BCIs) promise transformative societal impact, from restoring lost motor, sensory, and speech function in patients with paralysis, stroke, sclerosis, and sensory deficits to serving as a high-bandwidth conduit between human cognition and machine intelligence. Realizing these visions requires moving from laboratory prototypes to chronic clinical systems that support thousands to millions of electrodes, several millimeters to centimeters deep beneath the brain surface, under strict heating and size limits. Almost every clinically relevant implant therefore operates in a weakly coupled regime, with coupling coefficients of $10^{-3}$ to $10^{-1}$ across centimetres of lossy tissue. In this regime, the wireless channel sets the limits of power-transfer efficiency, communication bandwidth, and energy per bit. We review the recent progress of bidirectional wireless links across inductive, mid-field, RF, ultrasonic, magnetoelectric, optical, UWB, and electro-quasistatic modalities, and benchmark them against the clinical axes of depth, size, and data rate. Within an approximately 10 mW communication budget set by the approximately $1^\circ$C tissue-heating ceiling, narrowband high-Q links are well suited for power transfer and low-speed data, but at 1-10 nJ/b cannot reach the greater than 10 Mbps to tens of Gbps uplinks that thousand- to million-channel interfaces demand, even with aggressive on-implant compression. This calls for sub-10 pJ/b and ultimately sub-1 pJ/b wireless links, where wideband techniques, such as ultra-wideband (UWB) and brain-channel communication (BCC), are suitable. We close with a quantitative framework for analyzing such wireless links and a co-design roadmap across electromagnetics, circuits, packaging, security, and regulation, toward secure, networked, million-channel brain interfaces.

0.34

Standard-Compliant Neuromorphic Integrated Sensing and Communications Aided by an Intelligent Reflecting Surface

eess.SP ·2026-08-14 ·Jiho Park, Jiechen Chen, Joonhyuk Kang, Osvaldo Simeone
similarity 0.61
Abstract

Neuromorphic computing enables event-driven, low-power inference and is therefore an attractive technology for jointly carrying out communication, sensing, and processing at resource-constrained wireless devices. Impulse radio ultra-wideband (IR-UWB) signaling, which is standardized in the IEEE 802.15.4 family and widely deployed for ranging and short-range communication, is naturally matched to neuromorphic processing, since both operate through sparse temporal events, or spikes. In this context, this paper studies a standard-compliant neuromorphic integrated sensing and communications (N-ISAC) system in which a single spiking neural network (SNN) receiver jointly demodulates digital data and detects a passive radar target directly from a common IEEE 802.15.4z high-rate-pulse-repetition-frequency (HRP) UWB waveform. Unlike prior N-ISAC work, which assumed a basic pulse-position-modulation interface and a simplified multipath channel, we consider the full standardized physical layer together with a realistic ray-traced channel aided by a reconfigurable intelligent surface (RIS). The model accounts for the frequency-selective response of a metamaterial-based RIS, which disperses the wideband IR-UWB pulses and can degrade both communication and sensing. Numerical experiments quantify the impact of RIS frequency selectivity on UWB ISAC and characterize the trade-off between ISAC performance and receiver computation energy.

0.04

NORA: Neuro-headstage for Online Recording and Actuation in Freely Behaving Animal Models

eess.SP ·2026-11-11 ·Savanna Blade, Yuhan Hou, He Jia, Laura Kondrataviciute, Runtian Yang +2 more
published similarity 0.53
Abstract · 5 pages, 7 figures. Accepted for publication in IEEE BioCAS 2026. Author accepted manuscript

This paper presents NORA, a compact wireless neuro-headstage designed for simultaneous neural recording and stimulation in freely behaving animal models. Separate recording and stimulation interfaces, each managed with a dedicated MCU and wireless module, are integrated into a fully head-mounted device compatible with standard Omnetics connectors; this separation allows for simultaneous recording and stimulation without sample-dropping or stimulation waveform distortion. To minimize stimulation artifacts and cross-domain interference, the recording and stimulation subsystems are electrically isolated with independent power domains and dedicated wireless communication paths. NORA has been validated through in vivo animal experiments, demonstrating acquisition of meaningful neural features with results comparable to a commercial wireless headstage. Together, these features establish a practical platform for artifact-reduced neuromodulation research.

0.31

Short-Range Microwave Interprobe Coupling in a Brain-Mimicking Phantom and Ex-Vivo Brain

eess.SP ·2026-10-12 ·Pouya Faeghi, Xiaoting Jia, Jeffrey S. Walling
similarity 0.51
Abstract · 8 pages, 10 figures, 3 tables

Objectives: Short-range wireless links (microwave range) between closely spaced devices in brain tissue are relevant to neural interfaces and intracranial sensing, yet the change in coupling between two such devices caused by a finite volume of brain-like tissue has rarely been measured directly. Technology or Method: This work characterizes a printed, microstrip-fed, parasitic-strip-loaded tapered-slot coupling probe in which only a partially inserted 12-mm wire enters the medium, while the printed structure remains outside. Results: Two fabricated probes showed a measured free-space -10-dB reflection band of 5.78 to 6.86 GHz and a fractional bandwidth of approximately 17.1%, consistent with full-wave simulation. In a controlled two-probe experiment, a homogeneous agar-gelatin-saline brain-mimicking phantom was introduced and removed while the probe arrangement and measurement conditions were retained. Introducing the phantom increased the measured transmission coefficient near 6.3 GHz by approximately 16 dB, and this differential was reproduced across repeated trials. More than five measurements in ex vivo goat brain followed the phantom transmission response within approximately 1.5 dB across the 5.78-6.86-GHz band. Time-domain analysis of the phantom-present link gave a system root-mean-square delay spread of approximately 210 ps. Full-wave dosimetry predicted a peak 1-g-averaged specific absorption rate of 1.05 W/kg for approximately 0.49 W accepted power. Conclusions and Clinical or Biological Impact: These results provide an experimentally validated reference for short-range probe coupling in brain-like media and support phantom-based bench evaluation of minimally invasive intracranial probes before in vivo studies.

0.23

HDR-DTCP: High-Dynamic-Range Differential Tissue-Coupled Wireless Powering for Tunable Biphasic Stimulation in Injectable Implants

eess.SP eess.SY ·2026-11-14 ·Asif Iftekhar Omi, Anyu Jiang, Han Wu, Sultan Mahmud, Mali Halac +4 more
similarity 0.50
Abstract

Next-generation implantable neurostimulators require efficient wireless power delivery in smaller, less invasive form factors, yet variations in tissue coupling, implantation conditions, and stimulation loads can alter received power (or requirements) and degrade energy-harvesting performance. This work presents high-dynamic-range (HDR) differential tissue-coupled powering (DTCP), termed HDR-DTCP, a body-coupled architecture in which noninvasive differential electrodes establish an AC electric field in tissue and a thread-like implant extracts power from the longitudinal potential gradient for on-chip harvesting and stimulation. Distributed coupling along the implant length, rather than receiver cross-section, enables minimally invasive injectable geometries, with harvested power scaling with implant length. A 65-nm complementary metal-oxide-semiconductor (CMOS) prototype integrates a reconfigurable four-stage energy harvester with automatic stage selection and a tunable constant-current biphasic stimulator, achieving 63.5\% peak power-conversion efficiency (PCE) at $-16.3$ dBm and $>50\%$ PCE over a 9-dB input-power range. Preliminary in-vivo validation of DTCP was done with a second application-specific integrated circuit (ASIC) on an injectable flexible substrate, capable of being delivered through a 14-gauge needle adjacent to the sciatic nerve of Sprague-Dawley rats (n=4). External copper-pad DTCP powering evoked repeatable hind-limb twitches and electromyography (EMG) response; ultrasound confirmed sub-millimeter nerve proximity, video-based paw-tip tracking captured the response, and 8-day post-implant dissection verified placement along the sciatic-nerve trajectory. Overall, this work provides an integrated wireless powering, energy-harvesting, and stimulation platform toward fully battery-free injectable neuromodulation implants.

0.21

Protocol-Flexible Custom NFC for Wire-Free Wearable Sensor Networks

cs.NI ·2026-09-20 ·Riku Maeda, Akihito Noda
publishedunusual similarity 0.49
Abstract · 4 pages, 5 figures, 1 table. Accepted manuscript; accepted for publication in IEEE Sensors Letters

This study presents a custom near-field communication (NFC) system with software-defined protocol implementation for wearable sensors distributed across the body. Conventional wired implementations can degrade wearability because of mechanical constraints, whereas radio-based wireless approaches such as Bluetooth are affected by body-induced signal attenuation and limited communication coverage. The proposed system is compatible with previously demonstrated fabric-integrated meander coils, which provides a feasible path toward garment-scale NFC communication areas. The system combines a microcontroller unit with compact modulation and demodulation circuits, allowing medium access control and other communication protocols to be implemented in software. Experimental results demonstrate continuous acquisition of three-axis acceleration data from three sensor tags, achieving a per-tag polling rate of $222\,\mathrm{Hz}$ and an effective throughput of approximately $16\,\mathrm{kbps}$, delivering $156$ valid samples per second per tag at a measured packet error rate of $30\%$.

0.64

A Miniaturized Wi-Fi HaLow-Based Wireless Imaging Transfer System for Capsule Endoscopy

eess.IV ·2026-10-09 ·Michele Bertozzi, Lorenzo Amelio, Sebastiano Strangio, Nikita J. Greenidge, Benjamin Calmé +3 more
similarity 0.45
Abstract

Wireless capsule endoscopy is constrained by severe limitations in size, available power, and reliable data transmission through biological tissues. Although recent advances in miniature imaging sensors have improved image quality, the wireless transmission of color images at practical frame rates remains a challenging task under the tight capsule constraints. We present the design and the experimental validation of a miniaturized Wireless Imaging Transfer (WIT) system for capsule endoscopy based on a sub-GHz IEEE 802.11ah (Wi-Fi HaLow) wireless link. In addition, a preliminary in-vivo validation of Wi-Fi HaLow communication is reported, showing that a stable through-body wireless link can be established across biological tissues in a clinically relevant porcine model. These in-vivo results provide direct experimental support for the adoption of sub-GHz Wi-Fi HaLow for capsule endoscopy applications. Experimental results demonstrate stable wireless image transmission at a resolution of 320x320 pixels, with measured end-to-end data rates above 12 Mbps and a transmission energy efficiency of 20.7 nJ/bit. We also report a detailed power consumption analysis, with a breakdown of the contributions from the imaging sensor, illumination, digital processing, and RF transmission. When all active subsystem contributions are considered, including the camera, digital processing, RF transmission, and illumination at 60% LED brightness, the total power consumption is approximately 477 mW, corresponding to a complete-chain energy consumption of approximately 39.6 nJ/bit. Overall, the measured performance confirms that sub-GHz Wi-Fi HaLow provides a promising trade-off among throughput, robustness, and energy efficiency for wireless imaging in capsule endoscopy.

0.22

A comparison between ceiling-mounted FMCW, IR-UWB and Wi-Fi radar for in-bedroom human activity monitoring and sleep interruption detection

cs.LG ·2026-08-20 ·Anton Lambrecht, Reda El Hail, Xianjun Jiao, Pieter Crombez, Dominique Schreurs +3 more
similarity 0.45
Abstract · This paper has been submitted to IEEE Access Journal and is currently undergoing review

Despite their growing importance for contact-free radio frequency (RF) based healthcare monitoring, different radio technologies such as frequency-modulated continuous wave (FMCW) radar, impulse radio ultra-wideband (IR-UWB), and Wi-Fi sensing are rarely compared under identical deployment conditions, as existing studies typically differ in hardware, datasets, and evaluation methodologies. In addition, the performance of ceiling-mounted radars, despite their practical deployment and cost advantages in healthcare environments, remain underexplored. Therefore, this paper presents a controlled comparison and analysis of ceiling-mounted FMCW, IR-UWB, and Wi-Fi sensing using synchronized recordings from 20 participants across six room layouts. All technologies are evaluated with the same convolutional neural network (CNN) on both a fine-grained 10-class human activity recognition (HAR) task and a coarse 4-class sleep monitoring task. IR-UWB achieves the highest cross-subject activity recognition performance (89.0% macro F1), while FMCW generalizes best to unseen room layouts (83.8% macro F1). For sleep monitoring, all technologies exceed 92% macro F1 in unseen environments. The results reveal a fundamental trade-off between recognition performance and environmental robustness, which can be explained through differences in range resolution, antenna diversity, Doppler resolution, and spatial information retention. These findings provide practical guidelines for the design of healthcare-oriented RF sensing systems.

0.24