CS Paper Radar

Protocol-Flexible Custom NFC for Wire-Free Wearable Sensor Networks

Riku Maeda, Akihito Noda

cs.NI ·submitted 2026-09-20 04:28 UTC · v1
publishedunusual

Abstract

This study presents a custom near-field communication (NFC) system with software-defined protocol implementation for wearable sensors distributed across the body. Conventional wired implementations can degrade wearability because of mechanical constraints, whereas radio-based wireless approaches such as Bluetooth are affected by body-induced signal attenuation and limited communication coverage. The proposed system is compatible with previously demonstrated fabric-integrated meander coils, which provides a feasible path toward garment-scale NFC communication areas. The system combines a microcontroller unit with compact modulation and demodulation circuits, allowing medium access control and other communication protocols to be implemented in software. Experimental results demonstrate continuous acquisition of three-axis acceleration data from three sensor tags, achieving a per-tag polling rate of $222\,\mathrm{Hz}$ and an effective throughput of approximately $16\,\mathrm{kbps}$, delivering $156$ valid samples per second per tag at a measured packet error rate of $30\%$.

Comment
4 pages, 5 figures, 1 table. Accepted manuscript; accepted for publication in IEEE Sensors Letters
Journal ref
IEEE Sensors Letters, vol. 10, no. 11, Art. no. 5506104, Nov. 2026
DOI
10.1109/LSENS.2026.3736589

Closest papers

Nearest neighbours by meaning across the whole index.

A Wearable Sensor Array on Conductive Textiles for Body Surface Temperature Mapping

eess.SP ·2026-10-27 ·Amiri Onuki, Akihito Noda
published similarity 0.62
Abstract · 6 pages, 6 figures. Accepted manuscript of a paper published in Proceedings of the SICE Festival 2026 with Annual Conference, September 14-1…

Continuous monitoring of body-surface temperature distributions can provide useful information for wearable health and thermal-condition monitoring. However, practical daily-use wearable systems for distributed temperature sensing remain difficult to implement because multiple sensor nodes require power delivery and data collection across a garment. Conventional wiring increases system complexity, reduces placement flexibility, and can compromise the wearability of garment-integrated sensor arrays. To address this issue, we present a conductive-textile-based wearable temperature sensing system in which the textile itself serves as a shared bus for both DC power delivery and data communication. Each sensor node is implemented as a compact, battery-free circular board with a diameter of 21 mm and a weight of 0.9 g, integrating a commercial temperature sensor and custom circuitry for UART/DC superposition. The shared textile bus enables flexible node placement without individual wiring while supplying power to each node. Address-based half-duplex UART with master polling enables collision-free multi-node communication. To demonstrate the system-level capability, we implemented an 18-node sensor array on a garment worn by a mannequin and developed a real-time temperature mapping viewer. In a thermal scanning demonstration using warm air from a heat gun with a set temperature of approximately 50 °C, the 18-node array captured spatiotemporal temperature variations over the garment surface at a refresh rate of 99.2 Hz. These results show that the proposed conductive-textile bus can support real-time, high-refresh-rate distributed temperature mapping, providing a practical basis for garment-integrated body-surface monitoring and future multi-sensor wearable systems.

0.41

Split-Ring Couplers for On-Skin Wi-Fi Communication via an SSPP Waveguide Textile

eess.SP physics.app-ph ·2026-11-09 ·Akihito Noda, Ryo Takahashi
similarity 0.55
Abstract · 4 pages, 6 figures

Textile spoof surface plasmon polariton (SSPP) waveguides offer guided on-body links, but their body-facing ground conductors obstruct coupling from on-skin wireless nodes. This letter presents a split-ring coupling interface using local ground recesses at the textile terminations, without patterned garment-side launchers. The capacitively loaded rings are supported by polydimethylsiloxane carriers with a thickness of 2~mm. An image-current model and full-wave simulations examine the effect of backing-ground spacing and determine the recess geometry. For a 450~mm textile waveguide on a water-filled body phantom, the measured $S_{21}$ at 2.45 GHz was $-$18.8~dB, versus $-$60.9~dB without the textile. A 625-position scan showed a maximum 5.1 dB reduction relative to the nominal position within the measured joint $\pm$5~mm placement region. A separate two-node IEEE~802.11n test demonstrated a 65~Mb/s physical-layer (PHY) rate with zero packet errors among 300 frames at $-$20~dBm transmit power through the coupler link. These results establish high-rate, placement-tolerant on-skin Wi-Fi communication through an SSPP waveguide textile.

0.26

Toward Motion Capture Textiles: A Batteryless IMU Array Powered and Networked Through a Conductive-Fabric Bus

eess.SP cs.NI ·2026-10-14 ·Ryusei Miyakawa, Akihito Noda
published similarity 0.54
Abstract · 4 pages, 4 figures, 1 table. Accepted for publication in IEEE Sensors Letters

Motion capture is increasingly important in healthcare, rehabilitation, and sports applications. However, conventional vision-based systems require camera infrastructure and line-of-sight conditions, limiting their use in daily environments. This paper proposes a location-independent platform for motion capture, based on an array of IMU (inertial measurement unit) sensor nodes without individual wiring or onboard batteries, enabled by two-dimensional communication and power delivery over conductive fabric. Pipeline processing in each sensor node, combined with a token-passing protocol, enables collision-free and stable data acquisition at 50 Hz. Real-time three-dimensional reconstruction of flexible objects is further demonstrated by applying Hermite spline interpolation to orientation data from grid-aligned IMUs. Against a cylinder of known radius, the reconstructed surface deviates by 2.60 mm RMS over the 225 mm span of the array. The reconstruction is formulated for the quasi-static regime, and this letter empirically validates it in that regime. The hardware platform and communication protocol implemented in this work enable further investigation toward dynamic motion capture textiles.

0.35

Plug-and-Play Quantum-Resistant BLE Pairing for Medical Implants via NFC Out-of-Band

cs.CR ·2026-10-06 ·Muhammad Asim Javaid, Muhammad Shafay Tanveer Hassan, Faaiz Umer, Sotirios Panagiotou, Christos Strydis +3 more
published similarity 0.53
Abstract · Accepted for presentation at the 2026 IEEE International Conference on E-health Networking, Application & Services (IEEE HealthCom 2026), Oc…

Bluetooth Low Energy (BLE) pairing establishes the cryptographic foundation for secure device communication. However, mainstream man-in-the-middle (MITM)-resistant pairing methods, such as Numeric Comparison and Passkey Entry, require user interfaces that implantable medical devices (IMDs) inherently lack, making Near-Field Communication (NFC)-assisted Out-of-Band (OOB) pairing an attractive alternative. Existing NFC-assisted OOB schemes authenticate a classical BLE key exchange that remains vulnerable to quantum attacks, while the NFC channel itself is susceptible to eavesdropping and active injection under stronger threat models. To address these limitations, we propose a lightweight, plug-and-play NFC-based OOB pairing protocol that performs a post-quantum key encapsulation mechanism (KEM) entirely over the NFC channel, ensuring that no shared secret is transmitted over NFC while reducing long-range radio-frequency (RF) exposure during pairing. The proposed protocol requires no modifications to the BLE stack and inherently resists RF battery-depletion attacks. Evaluation on an IMD-class proof-of-concept testbed demonstrates that post-quantum OOB pairing is practical on resource-constrained devices, reducing projected battery life by less than 0.57\% for Kyber-1024 and 0.56\% for FireSABER under an operational usage model relative to the MITM-vulnerable Just Works method.

0.33

A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

cs.AR eess.SPeess.SY ·2026-11-05 ·Wei Ren, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang +2 more
similarity 0.52
Abstract · 11 pages, 9 figures

Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG--SCG--DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

0.24

Cyber-Secure Wearable, Ultra-Low-Power Networked Sensors for Soldier Health Monitoring: Insights from the CAPSARII project

cs.ET cs.AIcs.ARcs.CR+2 ·2026-11-15 ·Luciano Bozzi, Christian Celidonio, Umberto Nuzzi, Massimo Biagini, Stefano Cherubin +17 more
publishedbenchmark similarity 0.51
Abstract · Pre-print version

The CAPSARII project advances a cyber-secure, ultra-low-power wearable platform and Internet of Battlefield Things (IoBT) framework to support real-time monitoring of military personnel and data-driven decision support. The architecture integrates smart-textile sensing, a body/squad area mesh, edge-deployed AI on secure RISC-V microcontrollers, and cloud/federated analytics for cross-mission learning and comparative studies. Two representative use cases--pilot fatigue and warfighters operating in harsh environments--guide requirements, validation, and interface design (including HUD and haptic feedback). As an initial step toward embedded models, we benchmark stress classification on a public wearable dataset: tree-ensemble baselines achieve state-of-the-art performance for accuracy and F1 (e.g., XGBoost: $\mathrm{Accuracy}=0.901\!\pm\!0.023$, $\mathrm{F1}=0.920\!\pm\!0.019$), while a feature-based Transformer attains the highest AUC ($0.963\!\pm\!0.025$), informing feature-engineering and compression choices for edge deployment. Building on these results, CAPSARII employs HW/SW co-design, model compression (pruning, quantization, distillation), and precision tuning to meet stringent energy and memory budgets; it further investigates Processing-in-Memory accelerators for future efficiency gains. A structured gap analysis highlights the remaining challenges: establishing validation standards for physiological signal quality and textile durability; achieving low-latency, scalable BAN/SAN communications under mobility and interference; and deploying hybrid lightweight/post-quantum cryptography with robust device identity and side-channel resilience on constrained endpoints. By consolidating these elements into a coherent, secure IoBT stack, CAPSARII delineates a practical roadmap from laboratory baselines to mission-ready soldier monitoring in both training and operational scenarios.

0.34

Mobility Enhancement of Patients Body Monitoring based on WBAN with Multipath Routing

cs.NI ·2026-10-02 ·Yasna Ghanbari Birgani, Nastooh Taheri Javan, Mohsen Tourani
publishedunusualhighly cited similarity 0.50
Abstract

One of the promising applications of wireless sensor networks (WSNs) is monitoring of the human body for health concerns. For this purpose, a large number of small sensors are implanted in the human body. These sensors altogether provide a network of wireless sensors (WBANs) and monitor the vital signs and signals of the human body; these sensors will then send this information to the doctor. The most important application of the WBAN is the implementation of the monitoring network for patient safety in the hospital environment. In this case, supporting patients' mobility is one of the basic needs, which has been underestimated in recent studies. The problem that involves providing the required energy for the units used in this type of network is challenging; for this reason, sent/received units with very low power consumption and with a very small radius are used in order to save energy. The resulting small sending range leads to the lack of support for patients' mobility. In this paper, the ad hoc mode is suggested for use to establish a network and a multipath routing algorithm for the purpose of supporting patients' mobility in a hospital setting. The results of the simulation show that, in addition to supporting patients' mobility, the use of the proposed idea instead of previously presented protocols reduces delays in data transmission and energy consumption; it also increases the delivery rate depending on the destination and the lifetime of the network, while increasing routing overhead.

0.62

An Energy Efficient Wearable for Monitoring Elderly People Health

eess.SP cs.CY ·2026-08-26 ·M. Much, A Moraes Filho, J. Sieg, F. Hessel, A. Cataldo Neto +1 more
similarity 0.49
Abstract · 8 pages, 11 figures

The aged population is exposed to risk situations, like falls, sudden changes in vital signs, and faints. These situations become common at this life stage due to a decrease in body capacity and illnesses increase. This scenario imposes attention on families and the national health system. Some studies propose to overcome this problem through elderly health monitoring systems based on smartphones, smartwatches, and other equipment that usually cover low-efficient communication systems and low battery life. This paper proposes an efficient health monitoring system based on Sigfox IoT service and a watch-type wearable device for sensing elderly motion, location, and vital signs to predict risk situations designed to achieve at least 30-days of battery life. Our experimental results show that this architecture is a low-cost, low-power, efficient, and feasible elderly health monitoring solution.

0.36