Split-Ring Couplers for On-Skin Wi-Fi Communication via an SSPP Waveguide Textile

Akihito Noda, Ryo Takahashi

eess.SP physics.app-ph ·submitted 2026-11-09 08:15 UTC · v1

Abstract

Textile spoof surface plasmon polariton (SSPP) waveguides offer guided on-body links, but their body-facing ground conductors obstruct coupling from on-skin wireless nodes. This letter presents a split-ring coupling interface using local ground recesses at the textile terminations, without patterned garment-side launchers. The capacitively loaded rings are supported by polydimethylsiloxane carriers with a thickness of 2~mm. An image-current model and full-wave simulations examine the effect of backing-ground spacing and determine the recess geometry. For a 450~mm textile waveguide on a water-filled body phantom, the measured $S_{21}$ at 2.45 GHz was $-$18.8~dB, versus $-$60.9~dB without the textile. A 625-position scan showed a maximum 5.1 dB reduction relative to the nominal position within the measured joint $\pm$5~mm placement region. A separate two-node IEEE~802.11n test demonstrated a 65~Mb/s physical-layer (PHY) rate with zero packet errors among 300 frames at $-$20~dBm transmit power through the coupler link. These results establish high-rate, placement-tolerant on-skin Wi-Fi communication through an SSPP waveguide textile.

Comment
4 pages, 6 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Protocol-Flexible Custom NFC for Wire-Free Wearable Sensor Networks

cs.NI ·2026-09-20 ·Riku Maeda, Akihito Noda
publishedunusual similarity 0.55
Abstract · 4 pages, 5 figures, 1 table. Accepted manuscript; accepted for publication in IEEE Sensors Letters

This study presents a custom near-field communication (NFC) system with software-defined protocol implementation for wearable sensors distributed across the body. Conventional wired implementations can degrade wearability because of mechanical constraints, whereas radio-based wireless approaches such as Bluetooth are affected by body-induced signal attenuation and limited communication coverage. The proposed system is compatible with previously demonstrated fabric-integrated meander coils, which provides a feasible path toward garment-scale NFC communication areas. The system combines a microcontroller unit with compact modulation and demodulation circuits, allowing medium access control and other communication protocols to be implemented in software. Experimental results demonstrate continuous acquisition of three-axis acceleration data from three sensor tags, achieving a per-tag polling rate of $222\,\mathrm{Hz}$ and an effective throughput of approximately $16\,\mathrm{kbps}$, delivering $156$ valid samples per second per tag at a measured packet error rate of $30\%$.

0.64

Short-Range Microwave Interprobe Coupling in a Brain-Mimicking Phantom and Ex-Vivo Brain

eess.SP ·2026-10-12 ·Pouya Faeghi, Xiaoting Jia, Jeffrey S. Walling
similarity 0.51
Abstract · 8 pages, 10 figures, 3 tables

Objectives: Short-range wireless links (microwave range) between closely spaced devices in brain tissue are relevant to neural interfaces and intracranial sensing, yet the change in coupling between two such devices caused by a finite volume of brain-like tissue has rarely been measured directly. Technology or Method: This work characterizes a printed, microstrip-fed, parasitic-strip-loaded tapered-slot coupling probe in which only a partially inserted 12-mm wire enters the medium, while the printed structure remains outside. Results: Two fabricated probes showed a measured free-space -10-dB reflection band of 5.78 to 6.86 GHz and a fractional bandwidth of approximately 17.1%, consistent with full-wave simulation. In a controlled two-probe experiment, a homogeneous agar-gelatin-saline brain-mimicking phantom was introduced and removed while the probe arrangement and measurement conditions were retained. Introducing the phantom increased the measured transmission coefficient near 6.3 GHz by approximately 16 dB, and this differential was reproduced across repeated trials. More than five measurements in ex vivo goat brain followed the phantom transmission response within approximately 1.5 dB across the 5.78-6.86-GHz band. Time-domain analysis of the phantom-present link gave a system root-mean-square delay spread of approximately 210 ps. Full-wave dosimetry predicted a peak 1-g-averaged specific absorption rate of 1.05 W/kg for approximately 0.49 W accepted power. Conclusions and Clinical or Biological Impact: These results provide an experimentally validated reference for short-range probe coupling in brain-like media and support phantom-based bench evaluation of minimally invasive intracranial probes before in vivo studies.

0.23

Effect of Twisted-Yarn Architecture on Pressure and Proximity Sensing Characteristics of Textile Capacitive Sensors for Robotic Skin

cs.RO physics.ins-det ·2026-08-14 ·Ishtia Zahir, Eslam Saleh, Maryam Rezayati, Güunter Grabher, Gaffar Hossain
similarity 0.47
Abstract · 10 pages. Submitted to IEEE Transactions on Instrumentation and Measurement

Textile-integrated capacitive sensors offer flexible and conformable tactile sensing for wearable electronics and human-robot interaction; however, the influence of yarn-level architecture on capacitive transduction characteristics remains insufficiently quantified. This work presents a textile capacitive sensing platform based on silver-coated yarns coated with polydimethylsiloxane and assembled into one-, two-, and four-layer twisted configurations. The influence of effective electrode overlap area and inter-fiber separation on the capacitive response is systematically investigated, enabling architecture-dependent tuning of pressure and proximity sensing characteristics. Pressure was calculated using the localized single-fiber contact area, corresponding to stresses of 0.4-3.9 MPa. Increasing the layer number improved mechanical strength and sensing performance: elongation at break increased from 37.5% to 62.5% and 85.0%, while the maximum load increased from 23.3 to 42.7 and 89.7 N. Sensitivity increased with layer number and frequency, reaching 0.1331 MPa$^{-1}$ for the four-layer sensor at 100 kHz. The four-layer configuration also exhibited low hysteresis, minimal thermal drift from 25 to 90 $^\circ$C, and stable operation over 15,000 cycles. Proximity detection ranges of 60, 50, and 40 mm were obtained for the one-, two-, and four-layer sensors, respectively, revealing an architecture-dependent sensitivity-range trade-off. A 4$\times$4 textile sensing array enabled spatial contact mapping, while robotic-arm integration demonstrated real-time touch and proximity detection with an end-to-end robotic system latency (from detection to robot reaction) of 403 ms. The results establish yarn architecture as a tunable design parameter governing the measurement characteristics of textile-integrated capacitive sensing systems.

0.12

A Wearable Sensor Array on Conductive Textiles for Body Surface Temperature Mapping

eess.SP ·2026-10-27 ·Amiri Onuki, Akihito Noda
published similarity 0.47
Abstract · 6 pages, 6 figures. Accepted manuscript of a paper published in Proceedings of the SICE Festival 2026 with Annual Conference, September 14-1…

Continuous monitoring of body-surface temperature distributions can provide useful information for wearable health and thermal-condition monitoring. However, practical daily-use wearable systems for distributed temperature sensing remain difficult to implement because multiple sensor nodes require power delivery and data collection across a garment. Conventional wiring increases system complexity, reduces placement flexibility, and can compromise the wearability of garment-integrated sensor arrays. To address this issue, we present a conductive-textile-based wearable temperature sensing system in which the textile itself serves as a shared bus for both DC power delivery and data communication. Each sensor node is implemented as a compact, battery-free circular board with a diameter of 21 mm and a weight of 0.9 g, integrating a commercial temperature sensor and custom circuitry for UART/DC superposition. The shared textile bus enables flexible node placement without individual wiring while supplying power to each node. Address-based half-duplex UART with master polling enables collision-free multi-node communication. To demonstrate the system-level capability, we implemented an 18-node sensor array on a garment worn by a mannequin and developed a real-time temperature mapping viewer. In a thermal scanning demonstration using warm air from a heat gun with a set temperature of approximately 50 °C, the 18-node array captured spatiotemporal temperature variations over the garment surface at a refresh rate of 99.2 Hz. These results show that the proposed conductive-textile bus can support real-time, high-refresh-rate distributed temperature mapping, providing a practical basis for garment-integrated body-surface monitoring and future multi-sensor wearable systems.

0.41

A Miniaturized Wi-Fi HaLow-Based Wireless Imaging Transfer System for Capsule Endoscopy

eess.IV ·2026-10-09 ·Michele Bertozzi, Lorenzo Amelio, Sebastiano Strangio, Nikita J. Greenidge, Benjamin Calmé +3 more
similarity 0.43
Abstract

Wireless capsule endoscopy is constrained by severe limitations in size, available power, and reliable data transmission through biological tissues. Although recent advances in miniature imaging sensors have improved image quality, the wireless transmission of color images at practical frame rates remains a challenging task under the tight capsule constraints. We present the design and the experimental validation of a miniaturized Wireless Imaging Transfer (WIT) system for capsule endoscopy based on a sub-GHz IEEE 802.11ah (Wi-Fi HaLow) wireless link. In addition, a preliminary in-vivo validation of Wi-Fi HaLow communication is reported, showing that a stable through-body wireless link can be established across biological tissues in a clinically relevant porcine model. These in-vivo results provide direct experimental support for the adoption of sub-GHz Wi-Fi HaLow for capsule endoscopy applications. Experimental results demonstrate stable wireless image transmission at a resolution of 320x320 pixels, with measured end-to-end data rates above 12 Mbps and a transmission energy efficiency of 20.7 nJ/bit. We also report a detailed power consumption analysis, with a breakdown of the contributions from the imaging sensor, illumination, digital processing, and RF transmission. When all active subsystem contributions are considered, including the camera, digital processing, RF transmission, and illumination at 60% LED brightness, the total power consumption is approximately 477 mW, corresponding to a complete-chain energy consumption of approximately 39.6 nJ/bit. Overall, the measured performance confirms that sub-GHz Wi-Fi HaLow provides a promising trade-off among throughput, robustness, and energy efficiency for wireless imaging in capsule endoscopy.

0.22

A Two-Element Capsule Antenna for Near-Field Polarization MIMO in Wireless Capsule Endoscopy

eess.SP ·2026-10-02 ·Pyry Kiviharju, Lauri Vähä-Savo, Clemens Icheln, Kenichi Takizawa, Katsuyuki Haneda
unusual similarity 0.43
Abstract · 12 pages, 21 figures. Submitted to IEEE Open Journal of Antennas and Propagation

Multiple-Input-Multiple-Output (MIMO) technology is considered to be a viable method for spectral efficiency and data rate enhancement in wireless communications. This article presents a two-element capsule antenna with orthogonal current distributions for polarization multiplexing in a wireless capsule endoscopy (WCE) application at 915 MHz. The proposed antenna was evaluated in a MIMO link where it served as the transmitter and an existing on-body antenna was the receiver. The performance was assessed in two distinct environments: an anatomically accurate human body model using full-wave (FW) simulations, and a homogeneous liquid tissue phantom, using both FW simulations and measurements. The former was used to evaluate the performance in a realistic environment and to demonstrate the superiority of the proposed capsule antenna against existing two-element antennas in the literature, while the latter aimed at verifying the antenna design by comparison of simulated and measured MIMO links. We studied channel capacity and eigenvalues for the comparisons. The MIMO link with the proposed antenna provided nearly doubled median channel capacity relative to a baseline single-input-single-output link, consistently in the simulations and measurements. Our results prove the suitability of the proposed antenna for polarization multiplexing and, in terms of channel capacity, establish it as the best conformal two-element capsule antenna design at 915 MHz.

0.31

Waves on the Walls: Empirical Characterization of mmWave Lateral Waves for Enhanced Indoor Coverage

cs.NI eess.SY ·2026-09-03 ·Apala Pramanik, Avhishek Biswas, Sasitharan Balasubramaniam, Christos Argyropoulos, Mehmet C. Vuran
published similarity 0.42
Abstract · Accepted for publication at the IEEE International Conference on Mobile Ad-Hoc and Smart Systems (MASS) 2026

High-frequency millimeter-wave (mmWave) communication systems are constrained by the surrounding environment, where walls are traditionally treated as obstacles that block or reflect signals indoors. Consequently, current beamforming strategies are tailored to circumvent these obstructions. In this paper, a paradigm shift is introduced that leverages lateral wave propagation along building interfaces to extend mmWave coverage. Unlike traditional reflections, lateral waves travel along the boundary between two media of different refractive indices and decay algebraically with distance, offering a potential alternative path for mmWave connectivity. While well-established at low frequencies in natural media, the existence of lateral waves at mmWave frequencies along engineered building materials has not been demonstrated before. To this end, the first experimental characterization of mmWave lateral waves along a wall is reported. Extensive controlled measurements are employed to characterize the signal-grazing geometry and to establish a frequency and distance-dependent path-loss model for this phenomenon. The results provide the first empirical foundation for a new class of interface-guided mmWave links.

0.37

Dielectric Models of Normal and Diseased Human Trabecular Bones at Microwave Frequencies

eess.SP physics.med-phphysics.bio-ph ·2026-11-03 ·Bilal Amin, Amra Mehboob, Eoghan Dunne, Ana González-Suárez, Finn Krewer +3 more
publishedhighly cited similarity 0.42
Abstract · 12 pages, 9 figures, 8 tables. Published in IEEE Open Journal of Antennas and Propagation (open access, CC BY 4.0)

The dielectric properties of biological tissues are used to investigate the interaction of electromagnetic (EM) fields with the human body. These properties are integrated into EM numerical simulations, such as the finite difference time domain (FDTD) method, using dielectric models such as Cole-Cole and Debye models. These computational tools are employed to study the propagation of EM waves within the human body. This paper has developed the one-pole and two-pole Cole-Cole and Debye models for the dielectric properties of normal and diseased human trabecular bone tissue at microwave frequencies (0.5-8.5 GHz). The dielectric properties of normal trabecular and cortical bone were derived based on the literature, while those of diseased human trabecular bones (osteoporotic and osteoarthritis) were acquired from a previous study conducted by the authors, which characterised the properties within the 0.5-8.5 GHz frequency range. This study has employed a weighted least squares method to optimise the one-pole and two-pole dielectric models' parameters. The accuracy of the developed dielectric models is validated by comparing the simulated results with the experimental data already published by the authors. The comparative analysis of the models demonstrated that the one-pole Cole-Cole model achieved a better fit compared to the one-pole Debye model across all bone types. Additionally, the two-pole Cole-Cole model exhibited a better fit than the two-pole Debye model. The proposed models can be used in numerical simulations to investigate the interaction of EM fields with bone tissue and develop and optimise microwave bone health monitoring and treatment techniques.

0.65