CS Paper Radar

A Two-Element Capsule Antenna for Near-Field Polarization MIMO in Wireless Capsule Endoscopy

Pyry Kiviharju, Lauri Vähä-Savo, Clemens Icheln, Kenichi Takizawa, Katsuyuki Haneda

eess.SP ·submitted 2026-10-02 13:06 UTC · v1
unusual

Abstract

Multiple-Input-Multiple-Output (MIMO) technology is considered to be a viable method for spectral efficiency and data rate enhancement in wireless communications. This article presents a two-element capsule antenna with orthogonal current distributions for polarization multiplexing in a wireless capsule endoscopy (WCE) application at 915 MHz. The proposed antenna was evaluated in a MIMO link where it served as the transmitter and an existing on-body antenna was the receiver. The performance was assessed in two distinct environments: an anatomically accurate human body model using full-wave (FW) simulations, and a homogeneous liquid tissue phantom, using both FW simulations and measurements. The former was used to evaluate the performance in a realistic environment and to demonstrate the superiority of the proposed capsule antenna against existing two-element antennas in the literature, while the latter aimed at verifying the antenna design by comparison of simulated and measured MIMO links. We studied channel capacity and eigenvalues for the comparisons. The MIMO link with the proposed antenna provided nearly doubled median channel capacity relative to a baseline single-input-single-output link, consistently in the simulations and measurements. Our results prove the suitability of the proposed antenna for polarization multiplexing and, in terms of channel capacity, establish it as the best conformal two-element capsule antenna design at 915 MHz.

Comment
12 pages, 21 figures. Submitted to IEEE Open Journal of Antennas and Propagation

Closest papers

Nearest neighbours by meaning across the whole index.

A Miniaturized Wi-Fi HaLow-Based Wireless Imaging Transfer System for Capsule Endoscopy

eess.IV ·2026-10-09 ·Michele Bertozzi, Lorenzo Amelio, Sebastiano Strangio, Nikita J. Greenidge, Benjamin Calmé +3 more
similarity 0.62
Abstract

Wireless capsule endoscopy is constrained by severe limitations in size, available power, and reliable data transmission through biological tissues. Although recent advances in miniature imaging sensors have improved image quality, the wireless transmission of color images at practical frame rates remains a challenging task under the tight capsule constraints. We present the design and the experimental validation of a miniaturized Wireless Imaging Transfer (WIT) system for capsule endoscopy based on a sub-GHz IEEE 802.11ah (Wi-Fi HaLow) wireless link. In addition, a preliminary in-vivo validation of Wi-Fi HaLow communication is reported, showing that a stable through-body wireless link can be established across biological tissues in a clinically relevant porcine model. These in-vivo results provide direct experimental support for the adoption of sub-GHz Wi-Fi HaLow for capsule endoscopy applications. Experimental results demonstrate stable wireless image transmission at a resolution of 320x320 pixels, with measured end-to-end data rates above 12 Mbps and a transmission energy efficiency of 20.7 nJ/bit. We also report a detailed power consumption analysis, with a breakdown of the contributions from the imaging sensor, illumination, digital processing, and RF transmission. When all active subsystem contributions are considered, including the camera, digital processing, RF transmission, and illumination at 60% LED brightness, the total power consumption is approximately 477 mW, corresponding to a complete-chain energy consumption of approximately 39.6 nJ/bit. Overall, the measured performance confirms that sub-GHz Wi-Fi HaLow provides a promising trade-off among throughput, robustness, and energy efficiency for wireless imaging in capsule endoscopy.

0.22

Is Dual Polarization Always Optimal? Unlocking New Spatial Degrees of Freedom

cs.IT eess.SP ·2026-10-28 ·Adrian Agustin, Xavier Mestre, Carlos Suárez García, Alberto Pellon Sancho
similarity 0.52
Abstract · Submitted to IEEE Communications Magazine

Current wireless communication systems are designed based on channel models obtained under the assumption of far-field operation, where electromagnetic waves can be approximated by a planar wave. In those circumstances, dualpolarized antennas seem to be the optimal solution for maximizing the spectral efficiency. However, the recent research on XLMIMO systems represents a paradigm shift, since communication may take place in the near-field and an additional degree of freedom can be achieved. This work presents a modular, lowcost tripolarized antenna at 2.4 GHz band, that is used to experimentally validate theoretical findings about tripolarized antennas, which are commonly based on orthogonal infinitesimal dipoles. The evaluation is carried out in two indoor scenarios and one outdoor scenario, with transmitter comprising multiple tripolarized antennas and a receiver equipped with a single tripolarized antenna. We show that this type of antenna can increase the number of spatial streams up to three or extend the region where terminals are able to achieve two spatial streams

0.27

Evaluating Wi-Fi HaLow for Next-Generation Capsule Endoscopy

eess.SY ·2026-10-25 ·Ziyao Zhou, Chen Shen, Tiancheng Cao, Hen-Wei Huang
similarity 0.51
Abstract

Capsule endoscopy is limited by its wireless link: insufficient throughput restricts image resolution and frame rate, whereas high-rate radios typically use higher carrier frequencies that experience greater attenuation through tissue. This work evaluates Wi-Fi HaLow (IEEE 802.11ah), a sub-GHz Wi-Fi standard, as an image link for capsule endoscopy. Across all tested combinations of modulation and coding scheme and bandwidth, the saturation TCP throughput reached 15.55 Mbps, and the fastest configuration also achieved the lowest energy per bit. Through power optimization strategies, the combined power consumption of the HaLow module and microcontroller at 1 frame per second (FPS) was reduced from 101.70 to 14.00 mW, which is comparable to that of Bluetooth Low Energy systems. In a simulated in vivo setting, the default rate control selected the highest tested MCS and bandwidth, indicating sufficient link quality; this configuration also had the lowest measured power in both the 1 FPS mode (13.59 mW) and the 30 FPS mode (174.21 mW). The capsule-to-receiver latency was 20.68 ms for a 24 KB frame, while the receiver-to-capsule latency was 4.77 ms for a command; this low-latency bidirectional communication supports real-time detection and manipulation for next-generation capsule endoscopy.

0.08

Sensitivity and Identifiability of Tumor-Related Changes in Longitudinal Microwave Breast Imaging

eess.SP physics.med-ph ·2026-10-19 ·Somayeh B. Shafiei, Ian Jeffrey, Vahab Khoshdel, Joe LoVetri
similarity 0.50
Abstract

Microwave imaging could monitor breast tumor response to neoadjuvant chemotherapy, but between-visit changes in breast positioning and normal tissue may confound tumor-related changes. We use eight patient-specific dielectric models from longitudinal MRI of two patients at four time points. For each model, 24-port S-parameters were simulated from 1 to 3 GHz, and Jacobians computed for tumor permittivity and loss, fibroglandular tissue (FGT) permittivity, and breast rotation and translation. 1 mm positioning changes produced changes 20 to 50 times larger than a 10% tumor permittivity change above 2 GHz. Nevertheless, tumor sensitivity patterns were weakly aligned with positioning patterns, tumor-FGT similarity exceeded 0.8 at only some visits, and the Jacobians remained well conditioned. Tumor responses are thus small but separable; monitoring will require positioning correction, frequency selection, and noise-aware detectability analysis.

0.23

Short-Range Microwave Interprobe Coupling in a Brain-Mimicking Phantom and Ex-Vivo Brain

eess.SP ·2026-10-12 ·Pouya Faeghi, Xiaoting Jia, Jeffrey S. Walling
similarity 0.50
Abstract · 8 pages, 10 figures, 3 tables

Objectives: Short-range wireless links (microwave range) between closely spaced devices in brain tissue are relevant to neural interfaces and intracranial sensing, yet the change in coupling between two such devices caused by a finite volume of brain-like tissue has rarely been measured directly. Technology or Method: This work characterizes a printed, microstrip-fed, parasitic-strip-loaded tapered-slot coupling probe in which only a partially inserted 12-mm wire enters the medium, while the printed structure remains outside. Results: Two fabricated probes showed a measured free-space -10-dB reflection band of 5.78 to 6.86 GHz and a fractional bandwidth of approximately 17.1%, consistent with full-wave simulation. In a controlled two-probe experiment, a homogeneous agar-gelatin-saline brain-mimicking phantom was introduced and removed while the probe arrangement and measurement conditions were retained. Introducing the phantom increased the measured transmission coefficient near 6.3 GHz by approximately 16 dB, and this differential was reproduced across repeated trials. More than five measurements in ex vivo goat brain followed the phantom transmission response within approximately 1.5 dB across the 5.78-6.86-GHz band. Time-domain analysis of the phantom-present link gave a system root-mean-square delay spread of approximately 210 ps. Full-wave dosimetry predicted a peak 1-g-averaged specific absorption rate of 1.05 W/kg for approximately 0.49 W accepted power. Conclusions and Clinical or Biological Impact: These results provide an experimentally validated reference for short-range probe coupling in brain-like media and support phantom-based bench evaluation of minimally invasive intracranial probes before in vivo studies.

0.23

Grouped Sparse Bayesian Estimation for Near-Field Massive MIMO Channels

eess.SP ·2026-10-12 ·Xingchen Fang, Lan Tang, Wei Xu
benchmark similarity 0.48
Abstract

This paper studies near-field massive MIMO channel estimation based on an electromagnetic channel model with limited pilots. Starting from Maxwell's equations, we derive the homogeneous background response and the scattering response in the spatial and wavenumber domains. It is found that a compact scattering cluster produces a localized receive--transmit transverse-wavenumber block across finite apertures, thereby yields a block-sparse NLOS channel coefficient matrix in the wavenumber domain. Considering the spatial non-stationarity of large-scale antenna arrays, we introduce visibility factors at the transmit and receive sides of the channel model. To solve the non-stationary sparse channel estimation problem in the wavenumber domain, we propose a visibility-aware block-sparse Bayesian channel estimation algorithm. Simulation results demonstrate that the proposed method achieves lower channel-estimation NMSE than benchmark schemes.

0.23

Polarforming for MIMO Covert Communications

cs.IT ·2026-10-07 ·Xin Xie, Jinpeng Xu, Yihang Huang, Li Zhou, Zhaolong Ning
benchmark similarity 0.48
Abstract · 13 pages, 8 figures, Submitted for possible publication in an IEEE journal

Covert communication conceals wireless transmission activity, but conventional multi-antenna designs rely mainly on spatial beamforming and can be constrained by limited spatial degrees of freedom. This paper investigates polarization-reconfigurable antenna (PRA)-aided multiple-input multiple-output (MIMO) covert communication, where Alice and Bob perform transmit and receive polarforming, respectively, and Willie uses a vertically polarized antenna for radiometric detection. We jointly optimize the transmit covariance matrix and the transmit and receive phase shift vectors to maximize Bob's achievable rate under the covertness and transmit power constraints. Under Gaussian signaling, perfect polarized channel state information, and known noise power at Willie, we derive his optimal radiometric threshold and exact minimum detection error probability (DEP) for a finite observation length, and convert the DEP requirement into a deterministic constraint on his received signal power. We further prove that, for a fixed transmission design, positive signal leakage becomes detectable as the observation length tends to infinity. To solve the design problem for a finite observation length, we develop an alternating optimization (AO) algorithm with a generalized water-filling covariance update and closed-form phase updates. Numerical results validate the exact DEP analysis and the rapid convergence of the proposed algorithm. Compared with the sufficient divergence-based condition, the exact covertness constraint permits a $0.99$--$1.12$~dB higher received signal-to-noise ratio (SNR) at Willie, while joint transmit and receive polarforming provides a rate gain of up to $53.8\%$ over the considered benchmark schemes.

0.25

Electromagnetic Channel Model and Sensing Performance for ISAC: The Case of a Single Cylindrical Scatterer

eess.SP cs.IT ·2026-11-17 ·Gabriele Gradoni, Ahmed Elzanaty, Yadong Yang, Mohsen Khalily, Mahmoud Shahabadi +4 more
top venuetheory similarity 0.47
Abstract · 16 pages; published in IEEE Transactions on Wireless Communications

We propose an electromagnetic wireless channel model for accurate target localization in radar-like sensing scenarios. The model employs a self-consistent method grounded in wave scattering theory and imposing boundary conditions, providing the (impedance) channel transfer matrix for a propagation channel with a single target modeled as a cylindrical scatterer. The model is: 1) physics-based, as it includes electromagnetic interactions between objects; 2) unified, as it is valid in both near- and far-field regions. Within the canonical two-dimensional and 2.5-dimensional configurations with line-source and dipole-source excitations, respectively, the model supports dielectric cylinders with frequency-dependent permittivity. Localization accuracy is assessed via the Cramer-Rao lower bound for a dielectric cylinder with variable position, radius, and dielectric constant. Provisions for future extensions to extended targets are discussed in the context of 3GPP channel modeling.

0.47