Abstract

Microwave imaging could monitor breast tumor response to neoadjuvant chemotherapy, but between-visit changes in breast positioning and normal tissue may confound tumor-related changes. We use eight patient-specific dielectric models from longitudinal MRI of two patients at four time points. For each model, 24-port S-parameters were simulated from 1 to 3 GHz, and Jacobians computed for tumor permittivity and loss, fibroglandular tissue (FGT) permittivity, and breast rotation and translation. 1 mm positioning changes produced changes 20 to 50 times larger than a 10% tumor permittivity change above 2 GHz. Nevertheless, tumor sensitivity patterns were weakly aligned with positioning patterns, tumor-FGT similarity exceeded 0.8 at only some visits, and the Jacobians remained well conditioned. Tumor responses are thus small but separable; monitoring will require positioning correction, frequency selection, and noise-aware detectability analysis.

Closest papers

Nearest neighbours by meaning across the whole index.

Dielectric Models of Normal and Diseased Human Trabecular Bones at Microwave Frequencies

eess.SP physics.med-phphysics.bio-ph ·2026-11-03 ·Bilal Amin, Amra Mehboob, Eoghan Dunne, Ana González-Suárez, Finn Krewer +3 more
publishedhighly cited similarity 0.60
Abstract · 12 pages, 9 figures, 8 tables. Published in IEEE Open Journal of Antennas and Propagation (open access, CC BY 4.0)

The dielectric properties of biological tissues are used to investigate the interaction of electromagnetic (EM) fields with the human body. These properties are integrated into EM numerical simulations, such as the finite difference time domain (FDTD) method, using dielectric models such as Cole-Cole and Debye models. These computational tools are employed to study the propagation of EM waves within the human body. This paper has developed the one-pole and two-pole Cole-Cole and Debye models for the dielectric properties of normal and diseased human trabecular bone tissue at microwave frequencies (0.5-8.5 GHz). The dielectric properties of normal trabecular and cortical bone were derived based on the literature, while those of diseased human trabecular bones (osteoporotic and osteoarthritis) were acquired from a previous study conducted by the authors, which characterised the properties within the 0.5-8.5 GHz frequency range. This study has employed a weighted least squares method to optimise the one-pole and two-pole dielectric models' parameters. The accuracy of the developed dielectric models is validated by comparing the simulated results with the experimental data already published by the authors. The comparative analysis of the models demonstrated that the one-pole Cole-Cole model achieved a better fit compared to the one-pole Debye model across all bone types. Additionally, the two-pole Cole-Cole model exhibited a better fit than the two-pole Debye model. The proposed models can be used in numerical simulations to investigate the interaction of EM fields with bone tissue and develop and optimise microwave bone health monitoring and treatment techniques.

0.65

Short-Range Microwave Interprobe Coupling in a Brain-Mimicking Phantom and Ex-Vivo Brain

eess.SP ·2026-10-12 ·Pouya Faeghi, Xiaoting Jia, Jeffrey S. Walling
similarity 0.57
Abstract · 8 pages, 10 figures, 3 tables

Objectives: Short-range wireless links (microwave range) between closely spaced devices in brain tissue are relevant to neural interfaces and intracranial sensing, yet the change in coupling between two such devices caused by a finite volume of brain-like tissue has rarely been measured directly. Technology or Method: This work characterizes a printed, microstrip-fed, parasitic-strip-loaded tapered-slot coupling probe in which only a partially inserted 12-mm wire enters the medium, while the printed structure remains outside. Results: Two fabricated probes showed a measured free-space -10-dB reflection band of 5.78 to 6.86 GHz and a fractional bandwidth of approximately 17.1%, consistent with full-wave simulation. In a controlled two-probe experiment, a homogeneous agar-gelatin-saline brain-mimicking phantom was introduced and removed while the probe arrangement and measurement conditions were retained. Introducing the phantom increased the measured transmission coefficient near 6.3 GHz by approximately 16 dB, and this differential was reproduced across repeated trials. More than five measurements in ex vivo goat brain followed the phantom transmission response within approximately 1.5 dB across the 5.78-6.86-GHz band. Time-domain analysis of the phantom-present link gave a system root-mean-square delay spread of approximately 210 ps. Full-wave dosimetry predicted a peak 1-g-averaged specific absorption rate of 1.05 W/kg for approximately 0.49 W accepted power. Conclusions and Clinical or Biological Impact: These results provide an experimentally validated reference for short-range probe coupling in brain-like media and support phantom-based bench evaluation of minimally invasive intracranial probes before in vivo studies.

0.23

RT-VSS: In-House Ray Tracing for Vital Signs Sensing in FR3 Band

eess.SP ·2026-09-14 ·Rudranil Chattopadhyay, Zhuangzhuang Cui, Achiel Colpaert, Sofie Pollin
similarity 0.51
Abstract · Submitted to the IEEE conference for potential publication

Vital Signs Sensing, enabled by the evolution of wireless communications, is inherently challenging as the chest's micro-Doppler signatures can be corrupted by multipath, body movement and noise. Additionally, the prospects of the Frequency Range (FR) 3 band, spanning 7-24 GHz, are compelling due to centimeter-scale wavelength improving phase sensitivity to chest motion, while its abundant bandwidth and rich multipath enhance temporal and spatial diversity. In this paper, we validate the feasibility of using cellular communications in the FR3 band to monitor a human's breathing and heartbeat in an indoor environment. Using Blender to model physiologically accurate vital-signs signals as ground truth and Sionna Ray Tracing simulations, we find that it is feasible to extract breathing and heartbeat waveforms at FR3 frequencies. Furthermore, we perform a comparative analysis of ISAC performance against representative sub-6 GHz (FR1) and mmWave (FR2) frequencies, indicating the utility of the study across the frequency bands.

0.26

A Two-Element Capsule Antenna for Near-Field Polarization MIMO in Wireless Capsule Endoscopy

eess.SP ·2026-10-02 ·Pyry Kiviharju, Lauri Vähä-Savo, Clemens Icheln, Kenichi Takizawa, Katsuyuki Haneda
unusual similarity 0.50
Abstract · 12 pages, 21 figures. Submitted to IEEE Open Journal of Antennas and Propagation

Multiple-Input-Multiple-Output (MIMO) technology is considered to be a viable method for spectral efficiency and data rate enhancement in wireless communications. This article presents a two-element capsule antenna with orthogonal current distributions for polarization multiplexing in a wireless capsule endoscopy (WCE) application at 915 MHz. The proposed antenna was evaluated in a MIMO link where it served as the transmitter and an existing on-body antenna was the receiver. The performance was assessed in two distinct environments: an anatomically accurate human body model using full-wave (FW) simulations, and a homogeneous liquid tissue phantom, using both FW simulations and measurements. The former was used to evaluate the performance in a realistic environment and to demonstrate the superiority of the proposed capsule antenna against existing two-element antennas in the literature, while the latter aimed at verifying the antenna design by comparison of simulated and measured MIMO links. We studied channel capacity and eigenvalues for the comparisons. The MIMO link with the proposed antenna provided nearly doubled median channel capacity relative to a baseline single-input-single-output link, consistently in the simulations and measurements. Our results prove the suitability of the proposed antenna for polarization multiplexing and, in terms of channel capacity, establish it as the best conformal two-element capsule antenna design at 915 MHz.

0.31

Electromagnetic Channel Model and Sensing Performance for ISAC: The Case of a Single Cylindrical Scatterer

eess.SP cs.IT ·2026-11-17 ·Gabriele Gradoni, Ahmed Elzanaty, Yadong Yang, Mohsen Khalily, Mahmoud Shahabadi +4 more
top venuetheory similarity 0.50
Abstract · 16 pages; published in IEEE Transactions on Wireless Communications

We propose an electromagnetic wireless channel model for accurate target localization in radar-like sensing scenarios. The model employs a self-consistent method grounded in wave scattering theory and imposing boundary conditions, providing the (impedance) channel transfer matrix for a propagation channel with a single target modeled as a cylindrical scatterer. The model is: 1) physics-based, as it includes electromagnetic interactions between objects; 2) unified, as it is valid in both near- and far-field regions. Within the canonical two-dimensional and 2.5-dimensional configurations with line-source and dipole-source excitations, respectively, the model supports dielectric cylinders with frequency-dependent permittivity. Localization accuracy is assessed via the Cramer-Rao lower bound for a dielectric cylinder with variable position, radius, and dielectric constant. Provisions for future extensions to extended targets are discussed in the context of 3GPP channel modeling.

0.47

Passive RF Sensing for People Counting with Dense IoT Networks

eess.SP ·2026-10-21 ·Federica Fieramosca, Vittorio Rampa, Michele D'Amico
similarity 0.48
Abstract

Radio Frequency (RF) convergence, the joint use of radio signals for both communication and sensing, is gaining increasing attention in research and industry, mostly for its potential in Internet of Things (IoT) applications. By using RF signals of opportunity, such as those generate by the wireless networks, RF sensing exploits the effects of human bodies on the electromagnetic waves to detect both people presence and their movements without requiring wearable devices. In this paper, we address the problem of estimating the number of people in a monitored area covered by several RF nodes of a wireless network: to this aim, we propose a composite diffraction-based model, namely C-MAM, to capture the cumulative RF attenuation induced by multiple human bodies. Building on this model, we derive the analytical resolvability bounds that quantify the maximum number of distinguishable individuals based on the layout geometry and other physical characteristics of the wireless network. These bounds allow for the pre-deployment assessment of RF sensing performance under different scenarios.

0.27

An Evidence-Guided Framework for Tissue-Barrier Impedance Review: Deletion and Resistance Sensitivity

eess.SP ·2026-10-23 ·Leo Yang, Yingtong Zhou
similarity 0.46
Abstract · 5 pages, 3 figures, 3 tables

Reviewing tissue-barrier impedance requires connecting spectral anomalies with resistance estimates and experimental context. We present an evidence-guided framework that coordinates numerical checks and traceable actions for human review. In-house simulations assess the effect of removing flagged frequencies, public datasets test model adaptation, and local measurements demonstrate the review workflow. Removing flagged frequencies reduced resistance error under quadratic objectives, whereas robust fitting showed little average benefit from deletion and a mean error increase for endpoint-pair perturbations. High errors clustered around a few fitted circuit parameter sets, highlighting the value of examining parameter identifiability. Under the tested noise and perturbation conditions, these findings support robust full-spectrum estimation, flag-guided inspection, and matched sensitivity checks.

0.26

A passive, battery-free flexible metasurface for implantable millimetre-wave radar glucose sensing

eess.SP physics.bio-ph ·2026-11-13 ·Kavya Saravanan, Rohini Ramachandran, Jean Pierre Ndabakuranye, Isabelle Shearer, Gursimran Singh +6 more
unusual similarity 0.46
Abstract

Continuous glucose monitors (CGM) break the skin barrier and require periodic sensor replacement. We investigated whether a passive, battery-free flexible metasurface, implanted beneath tissue and read by a commercial 60 GHz radar, can track blood glucose levels. The metasurface contained no electronics or reagents. We fitted a conical helix to the in-phase and quadrature radar signals across the frequency sweep and used its mean radius (the spiral radius) as the glucose-dependent feature. We tested glucose concentrations of 25 to 400 mg/dL in saline solution with and without the metasurface, and 196 to 596 mg/dL of total glucose in porcine whole blood beneath ex vivo porcine tissue and in a murine cadaver model with pulsatile blood flow. The metasurface was essential for achieving a monotonic sensor response; in saline, the coefficient of determination ($R^2$) of a logarithmic fit increased from 0.18 without the metasurface to 0.90 with it. In a murine (rat) cadaver model, the signal's spiral radius increased monotonically with glucose concentration despite pulsatile flow ($R^2$ = 0.91), and this monotonic behavior persisted through up to 6 mm of tissue. Although sensitivity decreased at higher glucose levels, each discrete concentration step remained clearly detectable. These results demonstrate that a shallow, passive implant paired with a commercial radar can effectively track blood glucose without requiring onboard electronics or batteries.