CS Paper Radar

Dielectric Models of Normal and Diseased Human Trabecular Bones at Microwave Frequencies

Bilal Amin, Amra Mehboob, Eoghan Dunne, Ana González-Suárez, Finn Krewer, Aoife Lowery, Martin O'Halloran, Adnan Elahi

eess.SP physics.med-phphysics.bio-ph ·submitted 2026-11-03 01:51 UTC · v1
publishedhighly cited

Abstract

The dielectric properties of biological tissues are used to investigate the interaction of electromagnetic (EM) fields with the human body. These properties are integrated into EM numerical simulations, such as the finite difference time domain (FDTD) method, using dielectric models such as Cole-Cole and Debye models. These computational tools are employed to study the propagation of EM waves within the human body. This paper has developed the one-pole and two-pole Cole-Cole and Debye models for the dielectric properties of normal and diseased human trabecular bone tissue at microwave frequencies (0.5-8.5 GHz). The dielectric properties of normal trabecular and cortical bone were derived based on the literature, while those of diseased human trabecular bones (osteoporotic and osteoarthritis) were acquired from a previous study conducted by the authors, which characterised the properties within the 0.5-8.5 GHz frequency range. This study has employed a weighted least squares method to optimise the one-pole and two-pole dielectric models' parameters. The accuracy of the developed dielectric models is validated by comparing the simulated results with the experimental data already published by the authors. The comparative analysis of the models demonstrated that the one-pole Cole-Cole model achieved a better fit compared to the one-pole Debye model across all bone types. Additionally, the two-pole Cole-Cole model exhibited a better fit than the two-pole Debye model. The proposed models can be used in numerical simulations to investigate the interaction of EM fields with bone tissue and develop and optimise microwave bone health monitoring and treatment techniques.

Comment
12 pages, 9 figures, 8 tables. Published in IEEE Open Journal of Antennas and Propagation (open access, CC BY 4.0)
Journal ref
IEEE Open Journal of Antennas and Propagation, vol. 7, no. 5, pp. 1843-1854, Oct. 2026
DOI
10.1109/OJAP.2025.3646766

Closest papers

Nearest neighbours by meaning across the whole index.

Sensitivity and Identifiability of Tumor-Related Changes in Longitudinal Microwave Breast Imaging

eess.SP physics.med-ph ·2026-10-19 ·Somayeh B. Shafiei, Ian Jeffrey, Vahab Khoshdel, Joe LoVetri
similarity 0.60
Abstract

Microwave imaging could monitor breast tumor response to neoadjuvant chemotherapy, but between-visit changes in breast positioning and normal tissue may confound tumor-related changes. We use eight patient-specific dielectric models from longitudinal MRI of two patients at four time points. For each model, 24-port S-parameters were simulated from 1 to 3 GHz, and Jacobians computed for tumor permittivity and loss, fibroglandular tissue (FGT) permittivity, and breast rotation and translation. 1 mm positioning changes produced changes 20 to 50 times larger than a 10% tumor permittivity change above 2 GHz. Nevertheless, tumor sensitivity patterns were weakly aligned with positioning patterns, tumor-FGT similarity exceeded 0.8 at only some visits, and the Jacobians remained well conditioned. Tumor responses are thus small but separable; monitoring will require positioning correction, frequency selection, and noise-aware detectability analysis.

0.23

Short-Range Microwave Interprobe Coupling in a Brain-Mimicking Phantom and Ex-Vivo Brain

eess.SP ·2026-10-12 ·Pouya Faeghi, Xiaoting Jia, Jeffrey S. Walling
similarity 0.54
Abstract · 8 pages, 10 figures, 3 tables

Objectives: Short-range wireless links (microwave range) between closely spaced devices in brain tissue are relevant to neural interfaces and intracranial sensing, yet the change in coupling between two such devices caused by a finite volume of brain-like tissue has rarely been measured directly. Technology or Method: This work characterizes a printed, microstrip-fed, parasitic-strip-loaded tapered-slot coupling probe in which only a partially inserted 12-mm wire enters the medium, while the printed structure remains outside. Results: Two fabricated probes showed a measured free-space -10-dB reflection band of 5.78 to 6.86 GHz and a fractional bandwidth of approximately 17.1%, consistent with full-wave simulation. In a controlled two-probe experiment, a homogeneous agar-gelatin-saline brain-mimicking phantom was introduced and removed while the probe arrangement and measurement conditions were retained. Introducing the phantom increased the measured transmission coefficient near 6.3 GHz by approximately 16 dB, and this differential was reproduced across repeated trials. More than five measurements in ex vivo goat brain followed the phantom transmission response within approximately 1.5 dB across the 5.78-6.86-GHz band. Time-domain analysis of the phantom-present link gave a system root-mean-square delay spread of approximately 210 ps. Full-wave dosimetry predicted a peak 1-g-averaged specific absorption rate of 1.05 W/kg for approximately 0.49 W accepted power. Conclusions and Clinical or Biological Impact: These results provide an experimentally validated reference for short-range probe coupling in brain-like media and support phantom-based bench evaluation of minimally invasive intracranial probes before in vivo studies.

0.23

Closed-form weak-wave propagation pressure amplitudes for arbitrary power-law attenuation

eess.SP physics.med-ph ·2026-09-16 ·Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila
publishedunusual similarity 0.50
Abstract · 7 pages, 2 figures, submitted to JASA Express Letters

Biological tissues exhibit power-law frequency dependence of the attenuation coefficient. We derive closed-form weak-wave expressions for fundamental, second-, and third-harmonic pressure amplitudes of monochromatic acoustic plane waves in homogeneous media with arbitrary power-law attenuation to extend classical expressions for quadratic attenuation. For linear frequency dependence of attenuation, one-dimensional simulations using the k-Wave k-space pseudospectral solver yielded 35-42% (classical) and 0-2% (proposed) normalized root-mean-square errors for fundamental-band depletion. This extension supports improved fundamental-band B/A estimation for quantitative ultrasound tissue characterization. A proof-of-concept through-transmission application in phantoms with nearly linear attenuation yielded experimental B/A estimation errors of 23.7-52.7% (classical) and 4.0-5.9% (proposed).

0.41

Pre- and Post-Exercise Monitoring of Physiological Skin States in Sportsmen Using 77 GHz FMCW Radar and Wavelet Scattering Transform

eess.SP ·2026-09-19 ·Vijith Varma Kotte, Muhammad Mahboob Ur Rahman, Sajid Ahmed, Tareq Y. Al-Naffouri
similarity 0.47
Abstract · 4 pages, 3 figures, 1 table, under review with a journal

This paper presents a contactless radar sensing framework that classifies physiologically-induced changes in the superficial skin layer following intense fixed-duration physical activity along with water intake restriction. A 77 GHz frequency-modulated continuous wave (FMCW) radar is used to capture high-resolution range profiles from the subject's chest, seated in front of the radar, before and after sports activity. Since the electromagnetic penetration into biological tissue is inherently shallow at millimeter-wave frequencies, the sensing is confined primarily to the stratum corneum and upper epidermis. We demonstrate that exercise-induced thermoregulation, perspiration residue deposition, and transient shifts in superficial tissue hydration produce measurable alterations in quasi-static radar reflectivity. We utilize single-chirp snapshots of duration 102.4 micro sec in order to suppress confounders such as slow-varying cardiopulmonary motion, followed by lightweight feature extraction via the Wavelet Scattering Transform (WST) and classification using light-weight machine learning models suitable for edge nodes. Leave-one-subject-out cross-validation on a dataset of 15 sportsmen measured pre- and post-exercise yields a mean classification accuracy of 91.55% with a 95% confidence interval of [84.27, 98.83]%. Interpretability analysis reveals that low-order scattering coefficients (capturing overall signal energy and amplitude stability) dominate discriminative power, consistent with quasi-static changes in skin surface permittivity. The results establish a proof-of-concept for radar-based, edge deployable classification of post-exercise skin states, opening new avenues for non-contact physiological monitoring in sports science.

0.26

A Two-Element Capsule Antenna for Near-Field Polarization MIMO in Wireless Capsule Endoscopy

eess.SP ·2026-10-02 ·Pyry Kiviharju, Lauri Vähä-Savo, Clemens Icheln, Kenichi Takizawa, Katsuyuki Haneda
unusual similarity 0.46
Abstract · 12 pages, 21 figures. Submitted to IEEE Open Journal of Antennas and Propagation

Multiple-Input-Multiple-Output (MIMO) technology is considered to be a viable method for spectral efficiency and data rate enhancement in wireless communications. This article presents a two-element capsule antenna with orthogonal current distributions for polarization multiplexing in a wireless capsule endoscopy (WCE) application at 915 MHz. The proposed antenna was evaluated in a MIMO link where it served as the transmitter and an existing on-body antenna was the receiver. The performance was assessed in two distinct environments: an anatomically accurate human body model using full-wave (FW) simulations, and a homogeneous liquid tissue phantom, using both FW simulations and measurements. The former was used to evaluate the performance in a realistic environment and to demonstrate the superiority of the proposed capsule antenna against existing two-element antennas in the literature, while the latter aimed at verifying the antenna design by comparison of simulated and measured MIMO links. We studied channel capacity and eigenvalues for the comparisons. The MIMO link with the proposed antenna provided nearly doubled median channel capacity relative to a baseline single-input-single-output link, consistently in the simulations and measurements. Our results prove the suitability of the proposed antenna for polarization multiplexing and, in terms of channel capacity, establish it as the best conformal two-element capsule antenna design at 915 MHz.

0.31

Time-Domain Data-Driven Loewner Reduced-Order Models for Electromagnetic Simulation

eess.SP physics.comp-ph ·2026-10-15 ·Pablo Biurrun, Carlos J. Ramos-Salas, Luis D. Angulo, Valentin de la Rubia
similarity 0.44
Abstract

This paper presents a data-driven Loewner framework for constructing reduced-order models (ROMs) from time-domain electromagnetic (EM) simulation data. High-fidelity simulation of microwave devices can be computationally expensive, particularly when fine spatial discretization and long observation windows are required. The proposed method uses transient input-output data to construct Loewner and shifted Loewner matrices, from which a reduced descriptor realization is obtained through singular value decomposition (SVD). The resulting models are identified from a limited training window and used to predict responses over substantially longer time intervals, with prediction windows up to 50 times the duration of the training window. The method is formalized as an explicit, reproducible algorithm and validated against full-order simulations for four microwave structures: a substrate-integrated-waveguide filter, a frequency-selective surface, an evanescent-mode coaxial comb-line filter, and a diplexer. The results demonstrate the potential of Loewner-based identification to provide compact models of electromagnetic responses while reducing the need for repeated full-order simulation.

0.23

Passive RF Sensing for People Counting with Dense IoT Networks

eess.SP ·2026-10-21 ·Federica Fieramosca, Vittorio Rampa, Michele D'Amico
similarity 0.44
Abstract

Radio Frequency (RF) convergence, the joint use of radio signals for both communication and sensing, is gaining increasing attention in research and industry, mostly for its potential in Internet of Things (IoT) applications. By using RF signals of opportunity, such as those generate by the wireless networks, RF sensing exploits the effects of human bodies on the electromagnetic waves to detect both people presence and their movements without requiring wearable devices. In this paper, we address the problem of estimating the number of people in a monitored area covered by several RF nodes of a wireless network: to this aim, we propose a composite diffraction-based model, namely C-MAM, to capture the cumulative RF attenuation induced by multiple human bodies. Building on this model, we derive the analytical resolvability bounds that quantify the maximum number of distinguishable individuals based on the layout geometry and other physical characteristics of the wireless network. These bounds allow for the pre-deployment assessment of RF sensing performance under different scenarios.

0.27

A passive, battery-free flexible metasurface for implantable millimetre-wave radar glucose sensing

eess.SP physics.bio-ph ·2026-11-13 ·Kavya Saravanan, Rohini Ramachandran, Jean Pierre Ndabakuranye, Isabelle Shearer, Gursimran Singh +6 more
unusual similarity 0.43
Abstract

Continuous glucose monitors (CGM) break the skin barrier and require periodic sensor replacement. We investigated whether a passive, battery-free flexible metasurface, implanted beneath tissue and read by a commercial 60 GHz radar, can track blood glucose levels. The metasurface contained no electronics or reagents. We fitted a conical helix to the in-phase and quadrature radar signals across the frequency sweep and used its mean radius (the spiral radius) as the glucose-dependent feature. We tested glucose concentrations of 25 to 400 mg/dL in saline solution with and without the metasurface, and 196 to 596 mg/dL of total glucose in porcine whole blood beneath ex vivo porcine tissue and in a murine cadaver model with pulsatile blood flow. The metasurface was essential for achieving a monotonic sensor response; in saline, the coefficient of determination ($R^2$) of a logarithmic fit increased from 0.18 without the metasurface to 0.90 with it. In a murine (rat) cadaver model, the signal's spiral radius increased monotonically with glucose concentration despite pulsatile flow ($R^2$ = 0.91), and this monotonic behavior persisted through up to 6 mm of tissue. Although sensitivity decreased at higher glucose levels, each discrete concentration step remained clearly detectable. These results demonstrate that a shallow, passive implant paired with a commercial radar can effectively track blood glucose without requiring onboard electronics or batteries.

0.25