Continuous glucose monitors (CGM) break the skin barrier and require periodic sensor replacement. We investigated whether a passive, battery-free flexible metasurface, implanted beneath tissue and read by a commercial 60 GHz radar, can track blood glucose levels. The metasurface contained no electronics or reagents. We fitted a conical helix to the in-phase and quadrature radar signals across the frequency sweep and used its mean radius (the spiral radius) as the glucose-dependent feature. We tested glucose concentrations of 25 to 400 mg/dL in saline solution with and without the metasurface, and 196 to 596 mg/dL of total glucose in porcine whole blood beneath ex vivo porcine tissue and in a murine cadaver model with pulsatile blood flow. The metasurface was essential for achieving a monotonic sensor response; in saline, the coefficient of determination ($R^2$) of a logarithmic fit increased from 0.18 without the metasurface to 0.90 with it. In a murine (rat) cadaver model, the signal's spiral radius increased monotonically with glucose concentration despite pulsatile flow ($R^2$ = 0.91), and this monotonic behavior persisted through up to 6 mm of tissue. Although sensitivity decreased at higher glucose levels, each discrete concentration step remained clearly detectable. These results demonstrate that a shallow, passive implant paired with a commercial radar can effectively track blood glucose without requiring onboard electronics or batteries.

Closest papers

Nearest neighbours by meaning across the whole index.

Pre- and Post-Exercise Monitoring of Physiological Skin States in Sportsmen Using 77 GHz FMCW Radar and Wavelet Scattering Transform

eess.SP ·2026-09-19 ·Vijith Varma Kotte, Muhammad Mahboob Ur Rahman, Sajid Ahmed, Tareq Y. Al-Naffouri
similarity 0.50
Abstract · 4 pages, 3 figures, 1 table, under review with a journal

This paper presents a contactless radar sensing framework that classifies physiologically-induced changes in the superficial skin layer following intense fixed-duration physical activity along with water intake restriction. A 77 GHz frequency-modulated continuous wave (FMCW) radar is used to capture high-resolution range profiles from the subject's chest, seated in front of the radar, before and after sports activity. Since the electromagnetic penetration into biological tissue is inherently shallow at millimeter-wave frequencies, the sensing is confined primarily to the stratum corneum and upper epidermis. We demonstrate that exercise-induced thermoregulation, perspiration residue deposition, and transient shifts in superficial tissue hydration produce measurable alterations in quasi-static radar reflectivity. We utilize single-chirp snapshots of duration 102.4 micro sec in order to suppress confounders such as slow-varying cardiopulmonary motion, followed by lightweight feature extraction via the Wavelet Scattering Transform (WST) and classification using light-weight machine learning models suitable for edge nodes. Leave-one-subject-out cross-validation on a dataset of 15 sportsmen measured pre- and post-exercise yields a mean classification accuracy of 91.55% with a 95% confidence interval of [84.27, 98.83]%. Interpretability analysis reveals that low-order scattering coefficients (capturing overall signal energy and amplitude stability) dominate discriminative power, consistent with quasi-static changes in skin surface permittivity. The results establish a proof-of-concept for radar-based, edge deployable classification of post-exercise skin states, opening new avenues for non-contact physiological monitoring in sports science.

0.26

Short-Range Microwave Interprobe Coupling in a Brain-Mimicking Phantom and Ex-Vivo Brain

eess.SP ·2026-10-12 ·Pouya Faeghi, Xiaoting Jia, Jeffrey S. Walling
similarity 0.48
Abstract · 8 pages, 10 figures, 3 tables

Objectives: Short-range wireless links (microwave range) between closely spaced devices in brain tissue are relevant to neural interfaces and intracranial sensing, yet the change in coupling between two such devices caused by a finite volume of brain-like tissue has rarely been measured directly. Technology or Method: This work characterizes a printed, microstrip-fed, parasitic-strip-loaded tapered-slot coupling probe in which only a partially inserted 12-mm wire enters the medium, while the printed structure remains outside. Results: Two fabricated probes showed a measured free-space -10-dB reflection band of 5.78 to 6.86 GHz and a fractional bandwidth of approximately 17.1%, consistent with full-wave simulation. In a controlled two-probe experiment, a homogeneous agar-gelatin-saline brain-mimicking phantom was introduced and removed while the probe arrangement and measurement conditions were retained. Introducing the phantom increased the measured transmission coefficient near 6.3 GHz by approximately 16 dB, and this differential was reproduced across repeated trials. More than five measurements in ex vivo goat brain followed the phantom transmission response within approximately 1.5 dB across the 5.78-6.86-GHz band. Time-domain analysis of the phantom-present link gave a system root-mean-square delay spread of approximately 210 ps. Full-wave dosimetry predicted a peak 1-g-averaged specific absorption rate of 1.05 W/kg for approximately 0.49 W accepted power. Conclusions and Clinical or Biological Impact: These results provide an experimentally validated reference for short-range probe coupling in brain-like media and support phantom-based bench evaluation of minimally invasive intracranial probes before in vivo studies.

0.23

Sensitivity and Identifiability of Tumor-Related Changes in Longitudinal Microwave Breast Imaging

eess.SP physics.med-ph ·2026-10-19 ·Somayeh B. Shafiei, Ian Jeffrey, Vahab Khoshdel, Joe LoVetri
similarity 0.46
Abstract

Microwave imaging could monitor breast tumor response to neoadjuvant chemotherapy, but between-visit changes in breast positioning and normal tissue may confound tumor-related changes. We use eight patient-specific dielectric models from longitudinal MRI of two patients at four time points. For each model, 24-port S-parameters were simulated from 1 to 3 GHz, and Jacobians computed for tumor permittivity and loss, fibroglandular tissue (FGT) permittivity, and breast rotation and translation. 1 mm positioning changes produced changes 20 to 50 times larger than a 10% tumor permittivity change above 2 GHz. Nevertheless, tumor sensitivity patterns were weakly aligned with positioning patterns, tumor-FGT similarity exceeded 0.8 at only some visits, and the Jacobians remained well conditioned. Tumor responses are thus small but separable; monitoring will require positioning correction, frequency selection, and noise-aware detectability analysis.

0.23

Dielectric Models of Normal and Diseased Human Trabecular Bones at Microwave Frequencies

eess.SP physics.med-phphysics.bio-ph ·2026-11-03 ·Bilal Amin, Amra Mehboob, Eoghan Dunne, Ana González-Suárez, Finn Krewer +3 more
publishedhighly cited similarity 0.43
Abstract · 12 pages, 9 figures, 8 tables. Published in IEEE Open Journal of Antennas and Propagation (open access, CC BY 4.0)

The dielectric properties of biological tissues are used to investigate the interaction of electromagnetic (EM) fields with the human body. These properties are integrated into EM numerical simulations, such as the finite difference time domain (FDTD) method, using dielectric models such as Cole-Cole and Debye models. These computational tools are employed to study the propagation of EM waves within the human body. This paper has developed the one-pole and two-pole Cole-Cole and Debye models for the dielectric properties of normal and diseased human trabecular bone tissue at microwave frequencies (0.5-8.5 GHz). The dielectric properties of normal trabecular and cortical bone were derived based on the literature, while those of diseased human trabecular bones (osteoporotic and osteoarthritis) were acquired from a previous study conducted by the authors, which characterised the properties within the 0.5-8.5 GHz frequency range. This study has employed a weighted least squares method to optimise the one-pole and two-pole dielectric models' parameters. The accuracy of the developed dielectric models is validated by comparing the simulated results with the experimental data already published by the authors. The comparative analysis of the models demonstrated that the one-pole Cole-Cole model achieved a better fit compared to the one-pole Debye model across all bone types. Additionally, the two-pole Cole-Cole model exhibited a better fit than the two-pole Debye model. The proposed models can be used in numerical simulations to investigate the interaction of EM fields with bone tissue and develop and optimise microwave bone health monitoring and treatment techniques.

0.65

GlucoPRISM: Protocol-Supervised Pretraining for Cross-Cohort Glucose Transfer

cs.LG ·2026-10-08 ·Adinath Madhavrao Dukre, Abdullah Mohammad, Yifan Lu, Eran Segal, Ahmed Metwally +1 more
similarity 0.41
Abstract

Continuous glucose monitoring (CGM) foundation models encode each day as one vector that mixes who the person is, what happened that day and how the sensor measured it, so measurement differences travel with the representation into new cohorts. We ask whether pretraining can place the measurement component that harms transfer in known coordinates, so that deployment drops them with a fixed projection and no target data. GlucoPRISM supervises a GlucoFM backbone with response contracts, rules for how each part of the representation should change when only the day or only the sensor changes: a 64-dimensional Trait band should change with neither, a 48-dimensional State band only across days, and a 16-dimensional Sensor band should track the device. Synthetic sensor views calibrated on paired Dexcom and Libre recordings, different-day pairs and glucose-summary targets supply this supervision without clinical labels. Across twelve cross-cohort directions, dropping the Sensor band from the same frozen encoder raises mean transfer AUROC from 68.75 to 73.57, against 69.3 for GlucoFM. The gain has two parts. Into CGMacros, the one target cohort recorded with two sensor types, filtering adds 11 to 19 points, and this holds when the generator is recalibrated on half of the participants and scored on the other half. On the other eight directions filtering is neutral and the encoder itself exceeds GlucoFM by 3.5 points. The device remains linearly decodable after filtering, so the filter removes a device-related component that harms transfer rather than all measurement information. The retained bands improve window AUROC on thirteen of fourteen public task--cohort cells (Holm-adjusted p=0.031) and correlation on fourteen of fifteen clinical endpoints in an external cohort of 9,303 participants.

0.16

Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

cs.AI ·2026-10-02 ·Yuxuan Hu, Shilin Shan, Jianfei Yang, Feng Xu
code/data similarity 0.41
Abstract · 19 pages, 11 figures. Project page: https://yuxuanhu9.github.io/HEAR/

Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.

0.38

An Evidence-Guided Framework for Tissue-Barrier Impedance Review: Deletion and Resistance Sensitivity

eess.SP ·2026-10-23 ·Leo Yang, Yingtong Zhou
similarity 0.40
Abstract · 5 pages, 3 figures, 3 tables

Reviewing tissue-barrier impedance requires connecting spectral anomalies with resistance estimates and experimental context. We present an evidence-guided framework that coordinates numerical checks and traceable actions for human review. In-house simulations assess the effect of removing flagged frequencies, public datasets test model adaptation, and local measurements demonstrate the review workflow. Removing flagged frequencies reduced resistance error under quadratic objectives, whereas robust fitting showed little average benefit from deletion and a mean error increase for endpoint-pair perturbations. High errors clustered around a few fitted circuit parameter sets, highlighting the value of examining parameter identifiability. Under the tested noise and perturbation conditions, these findings support robust full-spectrum estimation, flag-guided inspection, and matched sensitivity checks.

0.26

VitalFR3: Wireless Vital Sign Sensing in the Upper Mid-Band (FR3)

eess.SP ·2026-10-03 ·Gholamreza Bakhshi, Hatem Abou-Zeid
similarity 0.40
Abstract · 14 pages, 12 figures

Frequency range 3 (FR3) is being explored for sixth-generation (6G) integrated sensing and communication (ISAC).However, experimental evidence on the feasibility of physiological sensing in this band is limited. This paper presents VitalFR3, an SDR-based frequency-modulated continuous-wave (FMCW) measurement platform that integrates a direct-sampling Ettus USRP X440 with a SignalCraft SC2470 frequency converter. To the best of our knowledge, this is the first calibrated SDRbased FMCW platform evaluated for respiration and cardiac-rate estimation from human measurements across multiple FR3center frequencies. Using a 100 MHz waveform, we operate the platform at six RF center frequencies from 10 to 22.5 GHz.We demonstrate how to characterize and calibrate the completeVitalFR3 transmit and receive path directly from loopback recordings, achieving a magnitude error below 0.061 dB at all six frequencies. We then propose a low-complexity end-to-end processing pipeline for vital sign estimation. This involves the identification of a persistent target-associated response in fast time, respiratory tracking in slow time, followed by cardiac- rate estimation. The system is evaluated across 16 human measurements, achieving a respiratory-rate mean absolute error of 0.758 breaths per minute, and the majority of the cardiac- rate estimates fall within 5 BPM of their reference rates. In a separate breath-hold measurement, the estimated cardiac rate is 84.3 BPM versus approximately 84.5 BPM from the reference. These results establish VitalFR3 as a calibrated and configurable measurement platform for experimental physiological sensing across FR3.

0.18