CS Paper Radar

VitalFR3: Wireless Vital Sign Sensing in the Upper Mid-Band (FR3)

Gholamreza Bakhshi, Hatem Abou-Zeid

eess.SP ·submitted 2026-10-03 02:01 UTC · v1

Abstract

Frequency range 3 (FR3) is being explored for sixth-generation (6G) integrated sensing and communication (ISAC).However, experimental evidence on the feasibility of physiological sensing in this band is limited. This paper presents VitalFR3, an SDR-based frequency-modulated continuous-wave (FMCW) measurement platform that integrates a direct-sampling Ettus USRP X440 with a SignalCraft SC2470 frequency converter. To the best of our knowledge, this is the first calibrated SDRbased FMCW platform evaluated for respiration and cardiac-rate estimation from human measurements across multiple FR3center frequencies. Using a 100 MHz waveform, we operate the platform at six RF center frequencies from 10 to 22.5 GHz.We demonstrate how to characterize and calibrate the completeVitalFR3 transmit and receive path directly from loopback recordings, achieving a magnitude error below 0.061 dB at all six frequencies. We then propose a low-complexity end-to-end processing pipeline for vital sign estimation. This involves the identification of a persistent target-associated response in fast time, respiratory tracking in slow time, followed by cardiac- rate estimation. The system is evaluated across 16 human measurements, achieving a respiratory-rate mean absolute error of 0.758 breaths per minute, and the majority of the cardiac- rate estimates fall within 5 BPM of their reference rates. In a separate breath-hold measurement, the estimated cardiac rate is 84.3 BPM versus approximately 84.5 BPM from the reference. These results establish VitalFR3 as a calibrated and configurable measurement platform for experimental physiological sensing across FR3.

Comment
14 pages, 12 figures

Closest papers

Nearest neighbours by meaning across the whole index.

RT-VSS: In-House Ray Tracing for Vital Signs Sensing in FR3 Band

eess.SP ·2026-09-14 ·Rudranil Chattopadhyay, Zhuangzhuang Cui, Achiel Colpaert, Sofie Pollin
similarity 0.76
Abstract · Submitted to the IEEE conference for potential publication

Vital Signs Sensing, enabled by the evolution of wireless communications, is inherently challenging as the chest's micro-Doppler signatures can be corrupted by multipath, body movement and noise. Additionally, the prospects of the Frequency Range (FR) 3 band, spanning 7-24 GHz, are compelling due to centimeter-scale wavelength improving phase sensitivity to chest motion, while its abundant bandwidth and rich multipath enhance temporal and spatial diversity. In this paper, we validate the feasibility of using cellular communications in the FR3 band to monitor a human's breathing and heartbeat in an indoor environment. Using Blender to model physiologically accurate vital-signs signals as ground truth and Sionna Ray Tracing simulations, we find that it is feasible to extract breathing and heartbeat waveforms at FR3 frequencies. Furthermore, we perform a comparative analysis of ISAC performance against representative sub-6 GHz (FR1) and mmWave (FR2) frequencies, indicating the utility of the study across the frequency bands.

0.26

Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

cs.AI ·2026-10-02 ·Yuxuan Hu, Shilin Shan, Jianfei Yang, Feng Xu
code/data similarity 0.64
Abstract · 19 pages, 11 figures. Project page: https://yuxuanhu9.github.io/HEAR/

Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.

0.38

A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

cs.AR eess.SPeess.SY ·2026-11-05 ·Wei Ren, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang +2 more
similarity 0.60
Abstract · 11 pages, 9 figures

Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG--SCG--DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

0.24

Packet-Level Complex CIR Tracking for Communication-Native mmWave Sensing: An 802.11ad Testbed

eess.SP ·2026-09-14 ·Raquel Marina Noguera Oishi, Haoqiu Xiong, Hany Assasa, Sofie Pollin
similarity 0.60
Abstract

Commercial millimetre-wave (mmWave) Wi-Fi platforms based on IEEE 802.11ad/ay have demonstrated sensing capabilities, but they provide limited visibility into the packet-level measurements and synchronisation mechanisms that determine temporal coherence. We present a programmable 60~GHz IEEE 802.11ad testbed that exposes the complete complex 128-tap channel impulse response (CIR) for every detected packet. This access exposes packet-to-packet delay shifts and common phase drift that commercial-transceiver studies generally do not characterise. We develop a delay-profile alignment method and define a static-reference relative CIR phase that cancels common drift while preserving target-induced variation. We use 30~s respiration sensing to evaluate long-term phase stability for sub-wavelength motion tracking. Across 39 recordings, median absolute waveform correlation increases from 0.41 (timestamp regularised) to 0.52 (delay aligned) and 0.61 (relative-phase calibrated); breathing-rate mean absolute error decreases from 5.1 to 4.1 and 3.6~breaths/min. The results demonstrate controlled characterisation and stabilisation of communication-native WiGig CIR measurements on a fully programmable physical layer.

0.26

CORAL: A Modality Invariant Framework for Robust Vital Sign Rate Estimation Using Correloform Analysis

eess.SP q-bio.QM ·2026-08-15 ·Jacob Trueb, Amey Kasbe, Aniruddh Srinivasan
benchmark similarity 0.58
Abstract · main manuscript: 11 pages, 2 tables, 4 figures supplemental materials: 25 pages, 4 tabes, 31 figures

Heart rate and respiration rate are crucial vital signs. We present CORAL to address challenges in automating continuous vital sign monitoring 1) in-hospital across broader populations (age, disease states), 2) at-home in telehealth and wellbeing applications (noise, placement), and 3) across data modalities (ECG, PPG, SCG, BioZ, etc.). We re-introduce Short-Time Autocorrelation Functions (STACFs) to introduce the correloform - a highly interpretable 2D signal transformation for tracking periodicity over time - and define CORAL as a generic analytical framework for robust rate estimation of quasi-periodic signals. We rigorously benchmark CORAL to show ubiquitous application in biosignals via capabilities arising by mathematical construction rather than domain-specific engineering, including rate estimation, resilient noise handling, automatic channel selection, and signal quality indication. CORAL achieves excellent instantaneous noninvasive fetal HR agreement in FECGSYNDB (F1 = 0.999) and ADFECGDB (F1 = 1.000). With difficult NICU neonates, CORAL estimates RR from wearable BioZ at r = 0.858 against breath-interval RR from simultaneous wired Philips impedance. CORAL SCG HR on CEBS achieves r = 0.990 and in free-living activity r = 0.970 when compared against commercial ECG. Without QRS detection, CORAL's instantaneous HR agrees with Pan-Tompkins and NeuroKit2 detectors as closely as they agree with each other (MIMIC-IV ICU ECG r = 0.87 to each vs. 0.88 between them). CORAL's HR standard deviation correlates strongly with interval-based HRV SDNN, even from mechanical SCG (CEBS r = 0.733) and across an ICU ECG cohort (r = 0.768).

0.10

A Subcarrier-Aware Approach for Robust Respiratory Monitoring with Commodity Wi-Fi

eess.SP ·2026-08-26 ·Pei Tang, Yunpeng Ge, Ivan Wang-Hei Ho
similarity 0.56
Abstract · 13 pages, 24 figures

Wi-Fi sensing has emerged as a promising modality for contact-free respiratory monitoring in home healthcare due to its ubiquity. However, conventional approaches typically treat Channel State Information (CSI) subcarriers uniformly, neglecting their heterogeneous responses to breathing motions. To address this limitation, we propose a subcarrier-aware sensing framework that characterizes subcarrier-dependent respiratory sensitivities and exploits them for informative subcarrier selection. Based on the statistical properties of breathing-sensitive subcarriers, we further develop an unsupervised clustering-based breathing estimation method for robust respiratory monitoring. Experimental results show that the proposed method achieves 97% breathing rate estimation accuracy and reduces the mean absolute error (MAE) by 0.45 breaths per minute (bpm) compared with baseline methods. Furthermore, we extend the analysis to breathing-pause detection, which derives an amplitude-attenuation-based threshold mechanism. Under breathing pauses, the proposed method achieves an MAE of 1.6 bpm in breathing rate estimation. These results demonstrate the robustness and effectiveness of the proposed framework across different scenarios and its potential for contactless home healthcare monitoring.

0.36

Acoustic Respiratory Phase Detection on Mobile Devices

cs.AI cs.LG ·2026-11-12 ·Julian Szymanski, Tomasz Sankowski, Piotr Sulewski, Iwo Czartowski, Javier Medina Quero
similarity 0.54
Abstract

Breathing monitoring is important for well-being, stress regulation, and guided breathing exercises, yet existing approaches often rely on contact-based sensors or controlled environments. This paper presents a non-invasive framework for respiratory phase detection using acoustic signals recorded on commodity smartphones. The proposed hybrid CNN-Transformer architecture combines local spectral feature extraction with long-range temporal modeling to capture the cyclic structure of breathing. The model is evaluated using a Leave-One-Subject-Out (LOSO) protocol on the Foundation Dataset and on an independent unseen test set comprising over 1300 breathing cycles and 2 hours of continuous recordings. The proposed 3-class formulation achieves 72.85% frame-level accuracy and 96.6% cycle-level exhalation detection efficiency in the LOSO evaluation, while achieving 76.94% frame-level accuracy, a Cohen's Kappa score of 0.65, and 99.2% cycle-level exhalation detection efficiency on the unseen test set. Results suggest that accurate respiratory monitoring may be achievable under data-constrained conditions, indicating that appropriate temporal modeling can learn transferable respiratory representations and generalize to previously unseen participants. An end-to-end ONNX deployment pipeline enables privacy-preserving on-device inference with latency below 20 ms, supporting real-time monitoring on mobile and wearable devices.

0.18

A Universal Raw-IQ Radar Encoder for Cross-Sensor Human Sensing

cs.CV cs.LG ·2026-11-03 ·Jonas Leo Mueller, Dario Zanca, Sebastian Hoefler, Jan Petermann, Thomas Altstidl +3 more
publishedbenchmarkpositioncode/data similarity 0.51
Abstract · Accepted at the 2027 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV)

Radar-based human sensing typically relies on end-to-end task-specific models trained on hand-chosen signal projections, which generalize poorly across unseen users, tasks, and hardware. We argue that the dominant signal processing choice, the micro-Doppler spectrogram, is a poor starting point for transfer because it keeps the Doppler axis, which carrier frequency rescales, and discards the angular axis, which carrier frequency leaves unchanged. We instead pretrain a convolutional beta-VAE without labels on clutter-removed raw radar measurements from four platforms spanning 60 and 77 GHz and 4 to 12 virtual antennas, aligned by a unified spectral interpolation grid. For every downstream benchmark the encoder stays frozen, and only a small supervised temporal classifier is trained on its embeddings. We compare against supervised models trained end to end on each benchmark and a pretrained radar foundation model across ten settings covering activity, gesture, sign-language, and gait recognition. When the test users and the radar are seen during training, our encoder is best on all five benchmarks. For users never seen in training, it leads on three of four benchmarks, by 4.8 to 23.2 points. On subject-disjoint gait recognition, it is best for each of the four held-out subjects and 8.3 points above the strongest baseline on average, even though its pretraining excluded every recording of this radar. Excluding the test radar from pretraining costs at most 5.3 points on any benchmark. Code is available at https://github.com/jonasmueler/UniversalRadarEncoder_WACV.

0.50